Measuring Manganese Concentration Using Spectrophotometry

Similar documents
EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline

Experiment 18 Determination of Iron by Visible Spectrophotometry

Chem 2115 Experiment #9. Consumer Chemistry: Determining the Iron Content in Supplements

Determination of the Mass Percentage of Copper in a Penny

Rev Experiment 10

CHM111 Lab Redox Titration Grading Rubric

Experiment #8. Redox Titration

Technical Procedure for Ultraviolet Spectroscopy

CHM Gravimetric Chloride Experiment (r7) 1/5

(aq) + 5e - Mn 2+ (aq) + 4H 2

SPECTROPHOTOMETRIC DETERMINATION OF IRON

Spectrophotometry of DNA and RNA

Write your own lab Spectrophotometry/Colorimetry

The following are the completed but unbalanced equations. Each equation is numbered to match each step of the cycle:

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

LAD B3 (pg! 1 of 6! ) Analysis by Redox Titration Name Per

OXIDATION-REDUCTION TITRATIONS-Permanganometry

The determination of copper in brass

Experiment 8. Determination of Iron in an Ore by Potentiometric Titration. Iron ores are often completely decomposed in hot concentrated HCl.

Lab #7: Redox Titration Lab Exercise Chemistry II 10 points Partner: USE BLUE/BLACK INK!!!! Date: Hour:

Experiment 3: Determination of an Empirical Formula

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

Cu (s) Cu 2+ (aq) Cu(OH) 2 (s) CuO (s) Cu 2+ (aq) Cu (s)

CONSERVATION OF MATTER AND CHEMICAL PROPERTIES

EXPERIMENT 7A. Chemical Separation by Filtration and Recrystallization INTRODUCTION

MAROOCHYDORE SHS. Student booklet. Including. ame: Teacher: Name. er: Maroochydore SHS Chemistry Department

The Importance of Water Absorbance/Transmittance on the Efficiency of Ultraviolet Disinfection Reactors

GRAVIMETRIC DETERMINATION OF SULFATE IN AN UNKNOWN SOLUTION

Copper Odyssey. Chemical Reactions of Copper

EXPERIMENT III. Determination of Iron in Iron Oxide, (Fe 2 O 3 ), Using Dichromate Method. Chemical Overview

TYPES OF CHEMICAL REACTIONS PART I INTRODUCTION

Salinity in Seawater

Archer G11 Partner: Judy Aug Gravimetric Analysis of a Metal Carbonate

A Cycle of Copper Reactions

John Congleton. Multistep Synthesis of Benzilic Acid:

DETERMINATION of the EMPIRICAL FORMULA

Gravimetric Analysis: Determination of % Sulfur in Fertilizer

Analysis of Calcium Carbonate Tablets

Drexel-SDP GK-12 ACTIVITY. Subject Areas: Chemistry, Physical Science, Numbers & Operations, Problem Solving

NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA (Zhenghua Renmin Gongheguo Guojia Biaozhun)

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement

CH 149: Chemical Principles. Fall KP1019 Module TA Manual

PREPARATION & ANALYSIS OF AN IRON COORDINATION COMPOUND PART A: PREPARATION OF AN IRON COORDINATION COMPOUND

A facile and fast method for quantitating lignin in lignocellulosic biomass using acidic

Chapter 8. Gravimetric Analysis

Differences in Free Energy of Solvation in a Two-Layer System

Effects of Gamma Radiation on Iron (III) Complex with Sodium Salicylate in Aqueous Solutions

IRON (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 600 C

CHM-202 General Chemistry and Laboratory II Laboratory 2 Molar Mass by Freezing Point Depression

Spectrophotometric Determination of Phosphates in Water

Demonstration of osmosis

30th International Chemistry Olympiad

Enzymes and Enzymatic Reactions Adapted with permission from the original author, Charles Hoyt

PERCENT Y IELD: COPPER T Ra NSFORMATIONS

BBI Solutions, Blaenavon AP 24 Analytical procedures Title: Glucose Oxidase Issue date: 1 st May 2013

EXPERIMENT 5 Chemistry 110 COMPOSITION OF A MIXTURE

THE MOLECULAR WEIGHT OF A SOLUTE*

Kinetic vs. Thermodynamic Control

Determination of Aluminum by Fluorometry

Method 8017 (0.7 to 80.0 µg/l) Powder Pillows. Scope and Application: For water and wastewater; digestion is required to determine total cadmium.

USEPA 1 Periodate Oxidation Method 2 Method to 20.0 mg/l Mn (HR) Powder Pillows

Polyvidone Polyvinylpyrrolidone H 2 C H C N

Method 108C - Determination of Arsenic Content in Ore Samples From Nonferrous Smelters (Molybdenum Blue Photometric Procedure)

Experiment 1: DNA Isolation from Plant and Animal Tissue and Gel Electrophoresis. Amber Broadbooks, Adrienne Martinez, Quenton Sayles

Applications of Oxidation/Reduction Titrations. Lecture 6

INTERDISCIPLINARY INVESTIGATION (IDI)-LAB LABORATORY HANDOUT

Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell

Partner: Cathy 22 March Separation and Qualitative Determination of Cations and Anions

National Food Safety Standard

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS. Shane Jordan-Hill. Merck Millipore

GOOD LABORATORY PRACTICE Agilent Cary 8454 UV-Visible Spectroscopy System

Analysis of Mineral and Heavy Metal Content in Beverages Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T223.

Analysis of total carotenoids using UV-vis spectrophotometry

SUMMARY OF STANDARDS FOR WATER ANALYSIS ON COURSE WAT-E2120 SPRING 2017

Orono Spectral Solutions, Inc.

EXPERIMENT 15 FREEZING POINT: A COLLIGATIVE PROPERTY OF SOLUTIONS

Analysis of Trace Metals in Tobacco and Tobacco Ash using Atomic Emission Spectroscopy

Experiment: Measurements

Chemistry 143 Empirical Formulas Dr. Caddell. Synthesis of Zinc Iodide and Magnesium Oxide

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

SPECIFICATIONS & TEST PROCEDURES ASPIRIN USP. Molecular Weight : Reference : USP 39

Lab 4: Recrystallization

Analysis of dissolved nitrite (NO 2- )

To identify and classify various types of chemical reactions.

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA

Lab #4 Gravimetric Analysis of a Metal Carbonate (adapted from Flinn Scientific ChemFax, 2005)

DR/4000 PROCEDURE. IRON, Ferrous. Using Powder Pillows

COPPER CYCLE EXPERIMENT 3

Potentiometric titration

Final Exam. Physical Constants and Conversion Factors. Equations

Chapter-IV OPTICAL PROPERTIES

METHOD DETERMINATION OF TURBIDITY BY NEPHELOMETRY. Edited by James W. O'Dell Inorganic Chemistry Branch Chemistry Research Division

Method 8.10 Refined sugar: sulphite (SO 2 ) by the Rosaniline method

Recrystallization with a Single Solvent

Colligative Properties of Solutions: Freezing Point Depression

CH 112 Special Assignment #4 Chemistry to Dye for: Part A

Electrophoresis 101 MiniLab

Transcription:

Measuring Manganese Concentration Using Spectrophotometry Objectives To use spectroscopy to determine the amount of Manganese is an unknown sample. Scenario Your have just joined a "Green Team" at the SMC eco-house on Pearl street and have been asked by your faculty mentor to determine the concentration of Manganese in a sample of groundwater taken from behind the old "Steel Works." This is one site being considered by the city of LA for the construction of a new elementary school. Your faculty mentor is on a committee hired by the city council to perform a preliminary investigation of the site for potential environmental hazards. Other green teams at the eco-house will be looking for lead, mercury, chromium, etc. The results of your analysis may help clear the way for the safe building of a new school; require the city council to recommend remediation (cleaning up) of the site before the school is built; or perhaps result in the selection of a new site for the construction. It is your task to determine the exact quantity of manganese in the sample you have been given. Many people's lives, jobs, and safety will depend on the answers you provide! Health Effects of Manganese: Eating a small amount of manganese each day is important in maintaining your health. The amount of manganese in a normal diet (about 2,000-9,000 g/day) seems to be enough to meet your daily need, and no cases of illness from eating too little manganese have been reported in humans. In animals, eating too little manganese can interfere with normal growth, bone formation, and reproduction. Too much manganese, however, can cause serious illness. Although there are some differences between different kinds of manganese, most manganese compounds seem to cause the same effects. Manganese miners or steel workers exposed to high levels of manganese dust in air may have mental and emotional disturbances, and their body movements may become slow and clumsy. This combination of symptoms is a disease called manganism. Workers usually do not develop symptoms of manganism unless they have been exposed for many months or years. Manganism occurs because too much manganese injures a part of the brain that helps control body movements. Some of the symptoms of manganism can be reduced by medical treatment, but the brain injury is permanent. It is not certain whether eating or drinking too much manganese can cause manganism or not. In one report, humans who drank water containing high levels of manganese developed symptoms similar to those seen in manganese miners or steel workers, but it is not certain if the effects were caused by manganese alone. In another report, people who drank water with above average levels of manganese seemed to have a slightly higher frequency of symptoms such as weakness, stiff muscles, and trembling of the hands. However, these symptoms are not specific for manganese, and might have been caused by other factors. Studies in animals have shown that very high levels of manganese in food or water can cause changes in the brain. This information suggests that high levels of manganese in food or water might cause brain injury, but it does not appear that this is of concern to people exposed to the normal amounts of manganese in food, water, or air. The chances of harm from exposure near a waste site can only be evaluated on a site-by-site basis. Information excerpted from: Toxicological Profile for Manganese July 1992, Agency for Toxic Substances and Disease Registry, United States Public Health Service. Measuring Manganese Concentration using Spectrophotometry Page 1 of 8

Background Spectroscopy is one of the most powerful analytical techniques in modern science. Before the advent of spectrophotometric techniques, a chemist interested in determining the amount of a particular substance present in a sample had to analyze the sample via a series of chemical reactions specific to that species and then weigh the products (entire tomes exist detailing such analytical reactions). This process was extremely time consuming, prone to error, and generally impractical for measuring trace amounts. Today, most routine assaying is done quickly and efficiently by means of spectroscopy. Spectroscopy works by correlating the concentration of a species in solution to the amount of light it absorbs. In this experiment we will determine the quantity of manganese using visible spectroscopy. Since the wavelengths of light we will use are in the visible portion of the electromagnetic spectrum, our solutions will all be colored. However this technique can also be used in other regions of the spectrum where the wavelength is not visible to our eyes, but can be measured using a photo-detector interfaced to a small computer. In a solution containing a colored compound, the intensity of the color can be used to measure the concentration of the compound; the more intense the color, the higher the concentration. The spectrophotometer measures how much light is absorbed at a given wavelength. The light absorption at that wavelength is expressed as a numerical value that can be related directly to the concentration of colored compound in the solution. In this experiment we will use spectroscopy to measure the amount of Manganese in an unknown solution. incident light Io transmitted light It Sample detector lamp Rotatable prism or grating Computer monochrometer A Wavelength Schematic diagram of a typical UV-Vis Spectrometer Experimental Considerations Two important questions to answer before using a spectrophotometer are: "What wavelength will I use to measure the absorption of my compounds?" and, "How will I calibrate my instrument to get accurate readings?" a) Choosing a wavelength The exact color of a solution (red, blue, etc.) is an indication of how much light is absorbed at different wavelengths by its constituent molecules when white light is passed through the Measuring Manganese Concentration using Spectrophotometry Page 2 of 8

solution. For example, a solution that appears red in color to the eye looks red because it absorbs most colors except for red. This may sound backwards, but if white light (containing all colors) illuminates a "red" solution, then blue, green, yellow, etc. are absorbed by the solution; leaving only red light to reach our eyes. Thus, we perceive the solution as being red since all the other colors were removed. Similarly a blue solution absorbs most colors except blue. Some solutions have colors that are mixtures of more than one color transmitted, for example a "turquoise" colored solution may result from a mixture of blue and green light coming through the sample, etc. 10 20 10 19 10 18 10 17 10 16 10 15 10 14 10 13 10 12 10 11 10 10 frequency, s -1 gamma rays X-rays ultraviolet visible infrared microwaves radar TV & FM radio 10-12 10-11 10-10 10-9 10-8 10-6 10-5 10-4 10-3 10-2 10-1 10-7 wavelength, m violet blue green yellow orange red Wavelength: = 390 455 490 600 770 nm 580 620 nm The Electromagnetic Spectrum Thus to answer the question, "What wavelength will I use to measure the absorption of my compounds?" It is important to choose a wavelength where the solution strongly absorbs light. For example if one is studying a red solution one would be far better off using green light (red's complement) which is strongly absorbed by the solution; rather than orange or red light that would be less strongly absorbed. The stronger the absorption at a particular wavelength the more sensitive the instrument will be at that wavelength and the more accurate your results. Thus for a red sample a wavelength in the green would probably be best; conversely if the sample was blue in color a wavelength in the red would probably be chosen. In practice one first determines the best range of wavelengths at which to test a solution and then selects one "best" wavelength for the experiment by measuring the absorption of the solution in question across this range and choosing the wavelength that gives the greatest absorption. For example, for the red solution described above, the experimenter might choose to measure the absorption of the sample at a range of wavelengths between 480nm and 560nm, and then narrow-in on the wavelength that gives the greatest numeric value of absorbance. Measuring Manganese Concentration using Spectrophotometry Page 3 of 8

Please note that while some spectrometers (so-called scanning spectrometers) can do this automatically; others (such as the ones in our labs) require changing the wavelength manually and each time the wavelength is adjusted these instruments need to be re-zeroed or they will not work properly. The Color Wheel is a guide to choosing complementary colors. A solution that is red is best analyzed using a wavelength in the green; a solution that is blue absorbs most strongly in the orange. b) Calibrating the instrument Once the specific wavelength that will be used for the experiment is chosen the experimenter needs to calibrate his or her spectrometer so that the absorbance readings can be converted into useful data such as molarity (M) of the sample. The absorbance of light (A) is directly proportional to the concentration of the species in solution (C). This relationship is known as the Beer-Lambert law (or sometimes just "Beer's law") and may be expressed as: A = ELC where E is the molar absorptivity (or the molar extinction coefficient), L is the path length or distance the light travels through the sample, and C is the concentration of the solution in units of molarity (M). In most instruments L is a constant (1.0 cm in our experiment) and can therefore be factored into E. Measuring Manganese Concentration using Spectrophotometry Page 4 of 8

Thus the Beer-Lambert equation can be simplified as: A = EC y = mx Which is the equation of a line where the intercept is through the origin (i.e. zero). The molar absorptivity, E, can therefore be determined by finding the slope of a plot of the absorbance as a function of concentration for a series of standard solutions of known concentrations. This is known as a calibration curve. Once E has been determined from the calibration curve, the Beer-Lambert equation can be used to determine the concentration of an unknown solution by measuring its absorbance under the same conditions. A new calibration curve is required if a different instrument, wavelength, type of solution, or procedure is used. It is also a good idea to check an instrument's calibration on a periodic basis. c) Preparing your known standards and unknown solution for analysis The solutions you will be given contain manganese ions, Mn 2+ (aq), and is an almost colorless solution. The manganese ions are easily oxidized in acidic solution to form permanganate ions, MnO 4 - (aq), an intensely purple species. The very intense color means that the analysis can be very sensitive because the light absorption will be relatively large, even with small amounts of manganese in the sample. Potassium periodate (KIO 4 ) will be used to oxidize Mn 2+ (aq) to the purple MnO 4 - (aq) ion, according to the following balanced reaction (all species aqueous): 2 Mn 2+ - + 5 KIO 4 + 3 H 2 O 2 MnO 4 (colorless) (purple) + 5KIO 3 + 6 H + Procedure Materials and Equipment Obtain the following equipment from the stockroom: 1 100.0-mL volumetric flask 3 25.00-mL volumetric flasks (one or two per group will be OK if supplies are short) 2 cuvettes for the spectrophotometer 1 1.00 ml volumetric pipette 1 5.00 ml volumetric pipette 1 10.00 ml volumetric pipette 1 rubber pipette bulb 1 beaker tongs (not the same as the crucible tongs in your locker) Your instructor will provide you with the spectrophotometer, stock solution, and unknowns. All other equipment is in your lab drawer. Measuring Manganese Concentration using Spectrophotometry Page 5 of 8

Instructions 1. Be sure to rinse your pipette with water followed by the stock solution before using. Pipette 5.00 ml of Mn 2+ (aq) stock solution into a clean 400-mL beaker. 2. Using a graduated cylinder to measure volumes, add 30 ml of deionized water to the 5.00-mL stock solution. Then add 10 ml of 9 M phosphoric acid (H 3 PO 4 ). (It is important to add the acid before adding the KIO 4 (s) in step 5 below). 3. Based on the concentration and volume of the known solution and the balanced reaction between Mn 2+ and KIO 4, calculate the minimum mass of KIO 4 required to oxidize all of the Mn 2+ in solution to MnO 4 -. Note: you will use double this amount to be certain that all of the Mn 2+ is actually oxidized. Show the results of this calculation to your instructor before actually proceeding. 4. Using a watch glass, weigh out double the amount of solid potassium periodate (KIO 4 ) you just calculated. Do not use paper for weighing as KIO 4 reacts with paper. 5. Add the KIO 4 to your solution in the hood and stir to dissolve using a glass stirring rod. Rinse any KIO 4 that sticks to the watch glass into the beaker using deionized water and your squirt bottle. Leave the stirring rod in the beaker to help control bubble formation when boiling. 6. Boil the solution gently. A purple color should appear. If it does not add more KIO 4 (add an additional 25% of your calculated value) and continue heating. Avoid splattering and boiling over! If you lose any material due to splattering you must start over repeating steps 1-4. Continue boiling gently for one to two minutes after the color changes to deep purple to be certain that the color change is complete. 7. Cool the solution and transfer the entire contents of the beaker to a 100.0-mL volumetric flask using a clean funnel. Rinse the inside of the beaker and the funnel with deionized water from your wash bottle and then transfer the rinse water to the volumetric flask as well to be sure you have transferred all of the manganese solution. 8. Dilute the solution in the volumetric flask with deionized water exactly to the index mark and mix thoroughly. 9. Calculate the concentration of MnO 4 (aq) in this standard solution. Label this solution "standard." You may want to transfer some of this solution to a separate container in case of "accidents." 10. Label three clean, dry, 25.00-mL volumetric flasks: 1, 2, and 3. Pipette accurately 1.00, 5.00, and 10.00 ml portions of your standard solution into these flasks. Be sure to rinse the pipettes with deionized water and standard solution first. Fill each flask with deionized water exactly to the index mark and mix well. Calculate the concentration (molarity, M) of MnO 4 (aq) ions in each of these flasks based on the molarity of your standard solution, volume of this you pipetted, and the total volume of your new diluted solution (25.00 ml). 11. Your group will only be given two cuvettes. Rinse these using deionized water and dry them completely using a Kim Wipe. 12. Use one cuvette for the blank and fill it ¾ full with deionized water and the other for each of the three solutions in the 25.00-mL volumetric flasks and the pure standard solution in the 100.0-mL volumetric flask. Measuring Manganese Concentration using Spectrophotometry Page 6 of 8

13. Before measuring the absorbance of your solutions you will need to zero your spectrometer and choose a wavelength. Your instructor will show you how to zero the spectrometer. It is up to your team to determine the best wavelength to use for this experiment a poor choice of wavelengths will result in poor data. See the introduction to this experiment for help in choosing a wavelength. If time is limited, your instructor may provide you with a specific wavelength to use. 14. Once you have zeroed the instrument and selected a wavelength, measure the absorbance of each of the three solutions in the 25.00-mL volumetric flasks and the pure standard solution in the 100.0-mL volumetric flask at this wavelength. You will have five measured data points including the blank (which should have a zero absorbance). 15. Make a calibration curve plotting the concentration (M) of the five solutions on the x-axis and the absorbance of each on the y-axis. Use a full sheet of graph paper to make your curve the bigger the plot the more accurate your estimate of the slope will be. Draw a best-fit-line through your points and determine the molar absorptivity, ε, the slope of your line. (Be sure to measure the slope of the best-fit-line; not specific data points see your instructor if this is unclear). Your intercept should be at the origin, since your blank solution counts as one of the points. Analyzing your unknown sample: 16. Prepare your unknown sample in exactly the same way you prepared your standard solution following steps 1-8 above using 5.00 ml of your unknown solution instead of the known stock solution in step 1. You do not need to repeat steps 9-15 with the unknown. 17. Measure the absorbance of the 100.0-mL purple solution prepared from your unknown at the same wavelength that you used to construct your standard curve. You can now use the equation of your best-fit-line to determine the concentration of MnO 4 (aq) ions in this solution. 18. Since this is a diluted solution, you will now need to calculate backwards from this concentration to determine the actual concentration of manganese in your original unknown sample. ALL WASTE MUST GO INTO THE CONTAINER IN THE HOOD! Measuring Manganese Concentration using Spectrophotometry Page 7 of 8

Procedure for making the known solutions and calibration curve 5.00 ml of Mn 2+ Pipette 5.00 ml of Mn 2+ (aq) Stock Solution (~0.3 mg Mn 2+ /ml) into a clean 400 ml beaker. Record the exact concentration. 400 ml beaker Add 30 ml deionized water + 10 ml 9M H 3 PO 4 + KIO 4 (s) Add the acid IN THE FUME HOOD before you add the KIO 4 (s). (you will need to determine how many grams of KIO 4 (s) to add using the balanced equation given) Use a glass stirring rod to mix. Place IN THE FUME HOOD and Boil gently for 1-2 minutes after a the solution turns purple. Do not splatter! After heating, Remove from hood and allow to cool. (If the solution does not turn purple add some additional KIO 4 ) Transfer the cool solution + rinse to a 100.0-mL volumetric flask using a funnel. Add deionized water to the mark and mix so the solution volume is 100.0 ml. Calculate the molarity (M) of MnO 4 (aq) in this new solution. This will be your "standard" solution. 100.0-mL vol. flask "standard" pipette: 1.00 ml standard 5.00 ml standard 10.00 ml standard + H 2 O to mark + H 2 O to mark + H 2 O to mark Pure Deionized water only 25.00 ml 25.00 ml 25.00 ml Blank (0) Cuvette (1) Cuvette (2) Cuvette (3) Cuvette (4) Finally: calculate the molarity of each dilution, choose λ, measure absorbances, and make a calibration curve. Measuring Manganese Concentration using Spectrophotometry Page 8 of 8