MODULAR BUILDING SPECIFICATIONS

Similar documents
Page 1 of 6

Whitley Shower Locker Toilet Facilities

G Garza+McLain NOT FOR CONSTRUCTION SITE PLAN - EXISTING SCALE: 1" = 50'-0" SHEET NOTES GENERAL NOTES KIPP JOURNEY MODULAR CAMPUS

Proposed Alisal Campus Childcare Expansion and Move - Comparison Chart

6'-0" G-4 ADJUSTABLE SHELVING 2'-0" 4'-5" MOP SINK STORAGE '-0" 2'-0" 26'-6" G-4 6' X 4' OPENING WITH SHUTTER BASE CABINETS 34" FOR ADA 20'-0"

Ontario Standard Building Spec for A277 Mini Homes- March 2018 Specifications based on Mini Home with insulated floor

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

Waikoloa Homesites. Kohala Coast, HI. Outline Specifications. Prepared By: 16 December 15

Mountainview Estates.

SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM)

Ontario Standard A277 Modular Building Spec - March 2018 Specs are based on Modular homes installed on full basements

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

Delta Gamma Sorority Renovation Budget Scope 3/7/2018

COLONIAL PLANS. 708 North Street US Highway Route 1 Houlton, Maine (207)532,2444

Mountain West SERIES

SPACE TYPE: ENHANCED OFFICE

Z & C Construction, Inc. Subdivision:

G703 Continuation Sheet Minimum Schedule of Values Please use the breakdown listed below when submitting your billing for the project

STANDARD CONSTRUCTION PACKAGE Addendum A REV SITE & EXCAVATION Layout of the foundation and septic system as approved by local and state author

The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits

TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS

Property: Operator Info: Operator: Estimator: Sales/Estimator. Labor Efficiency:

INVITATION FOR BIDS. Office Trailer (CIP# ABD1903)

Price, plans and specifications are subject to change without notice. Revised 01/2018

TABLE OF CONTENTS Public Safety Building

Cheshire, CT. By: A.M. Napolitano, LLC. Project Manager: Carolyne Sakonchick Ext. 323

PHASE I ACADEMIC BUILDING CORE RENOVATIONS RCNJ Project No C

OFFICE Space STANDARD SPECS Page 1

Building Systems and Design Elements included in SliDeRulE

Welcome to Smithfield Crossing Condominiums

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

Priced from $1,525,000

Cheshire, CT. Project Managers: Pat O Neill & Marilyn Rock Ext. 309 & 307

ADDENDUM 2 - JULY 14, 2015

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

OFERTE BISERICA TEMPORARA Technical Analyses

Schedule D. RTM Finished Home Specifications

Karl Tarango (970)

UNIFIED FACILITIES GUIDE SPECIFICATIONS ************************************************************************** SECTION TABLE OF CONTENTS

Carter's Oshkosh (SIS) # The Center at Pearland Parkway - Pearland, TX Scope Of Work / Bid Qualifications

Gerald Desmond Bridge Replacement

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

Existing Site Aerial Frederick High School Feasibility Study September 5, 2012

FRANKLIN VILLAGE APARTMENTS Building I Franklin Street Morristown, NJ Block: 3901 Lots: 4,5,6

TABLE OF CONTENTS Updated 1/2014 SECTION TITLE DATE

4.1.3 Project Manual

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

Minneapolis Community and Technical College T-Building Floor 2 Student Affairs Cost Estimating Form Templates - Exhibit C

Budget Estimate Basic Tenant Improvement

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

FOUR CORNERS CUSTOM BUILDERS, LLC

Schedule C STANDARD Specifications

keystone FLOOR PLANS 1536 SQUARE FEET 3 Bedroom - 2 Bath MODEL KEY32483A 1792 SQUARE FEET 3 Bedroom - 2 Bath MODEL KEY32653B

CENTRAL GREAT PLAINS SERIES


Lexington. ~Built in Lancaster, Wisconsin~ 28/32 Series. Lexington. Your Local. Dealer is: Some Items Shown May Be Optional

What this Family Room Specification Package can be used for:

SANDTOWN CROSSING PROFESSIONAL OFFICE PARK Atlanta, GA

CM ASSIGNMENT OF TEMPORARY FACILITIES see included IU Project Site Requirements

Price, plans, and specifications are subject to change without notice. MAPLE 2,081 SQ.FT. 3 BEDROOMS 3.5 BATHROOMS 2 STORIES

pershing+ desperes uichomes.com 6005 and 6007 Pershing Avenue pershing+desperes call or

Edouard AVANT GROVE U I C U I C. Modern Living Made Easy uichomes.com

Boyle. contemporary new homes with great curb appeal. boyle call or 3br/2.5bth, 1905sf

Timberglen Recreation Center Summary

HC Homes at Tehaleh. Framing

COOPERSMITH COURT. For more information, contact: Maggie Houston

COOPERSMITH COURT. For more information, contact: Maggie Houston

FIREMASTER 60 SERIES. Fire Resistant, Affordable, Innovative

$59,90 sf. installed! Shipped & Installed in less than 30 days!

HC Homes at Tehaleh Standard Features

SPECIFICATIONS AND BID FORM FOR THE PURCHASE OF NEW MODULAR CLASSROOM BUILDINGS GENERAL SPECIFICATIONS

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

Pembridge The Country Club Collection TOWNHOMES AT CRYSTAL SPRINGS

General Construction Specifications For

Décor Design Construction llc

Helms Builders, Inc.

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up

RIVERSIDE TERRACE. For more information, contact: Maggie Houston, ,

Division 00 Procurement and Contracting Requirements

Electrical & designer allowance

Carpentry. The following describes the scope and sequence of instruction for Carpentry.

PROCUREMENT AND CONTRACTING DOCUMENTS GROUP

RB Homes, Inc. 152 Witherspoon St. Princeton, NJ P: (609) / F: (609)

Wellington Manor Series

standard features Power Exhaust Fans w/light - Both Baths GFCI Receptacles Upgrade Light Fixture - Bath 1 Vanity - Per Lav GFCI Receptacles

RB Homes, Inc. 152 Witherspoon St. Princeton, NJ P: (609) / F: (609)

RECAPP Facility Evaluation Report

ELEMENTS COLLECTION 1

TULANE PLAN ,486 SQ.FT.

RESIDENTIAL GRADE FACTORS

K and V HOMES. Client Questionnaire. Location. (Skip to page 3) Tree Removal Required. Yes No. Entrance

Smokey Ridge, Christiansburg, Virginia

SPECIFICATION: CLASSIC PROGRESSIVE MOVABLE WALL SYSTEM DEMOUNTABLE STEEL STUD AND GYPSUM BOARD PARTITIONS

PAULDING COLLEGE & CAREER ACADEMY

SANDTOWN CROSSING PROFESSIONAL OFFICE PARK Atlanta, GA

Burlington Model at Country Hills Estates

Seal Harbor Development 1 Nagog Park Acton, MA 01720

Columbia County Health Care Center Added Amenities

General Conditions 39,522 5, ,292 26,050 75,921 1, Labor hours

Transcription:

Use Group A - Assembly B Business E Education I - Institutional Construction Type Type II Non Combustible Type V - Wood Floor 12 Outrigger Frame with Cross members Frame: 12 Perimeter Steel Main Beams 12 Perimeter Steel with Steel Cross Members Bottom: 1 Mil Cross-woven polypropylene fabric Insulation: Un-faced Fiberglass Joists: 2 x 6 @ 16 O.C. Longitudinal 8 Steel Cross members 16 O.C. Single Layer ¾ T&G OSB Underlayment Double Layer ¾ T&G OSB Underlayment Decking: ¾ Concrete Composite Panels with 1/4 Hardie Backer Second Layer 1/8 Vinyl Composition Floor Tile (12 x 12 ) Finish: 26 Ounce Grade Carpet (unitary back) 30 x 30 Carpet Squares with Rubber Backing Ceramic Tile Exterior and Interior Walls 2 x 4 #2 SPF @ 16 O.C., Single Bottom Plate and Studs: Double Top Plate 6 x 16 Gauge Steel 16 O.C. Interior: ½ Vinyl Clad Gypsum 5/8 Type Gypsum Vinyl Covered Wall Paper Applied to Gypsum Covering: Fiberglass Reinforced Paneling Mud, Tape, Texture and Paint Insulation: Ext R-13 Kraft Faced F/G Int R-11 Unfaced F/G Structural 7/16 OSB Sheathing: Moisture Sheathing 5/8 Dens-glass Building wrap (DuPont Wrap Tyvek or equal)

Exterior Siding: Base: Corners: Ceiling / Wall: Mate line: Rafters: Insulation: Sheathing: Roofing: Gutters: Ceiling: Exterior and Interior Walls Continued.019 Aluminum Siding Hardie Panel Vertical Panels (stucco or sierra) 29 Gauge Hi-ribb Steel Siding and Trim Synthetic Stucco over Hardie Panel Masonry Stucco Applied on Site Hardie Reveal Panel Interior Trim Vinyl Covered Batten Strip 4 Vinyl Cove Base Throughout with 6 Vinyl Cove Base in Restrooms Vinyl Covered Battens Mud Tape and Paint Vinyl Covered Battens White Suspended Ceiling Wall Angle for T-grid Ceiling 6 Crown Molding Roof (1) Layer 1-1/2, 2.0 LVL (Max span 30-0 typical) Steel Truss Clear Span (Max span 60-0 typical) 2x8 or 2x10 Roof Rafters @16 OC w/ledge to LVL 18 Gauge x 8 Steel Rafters 16 OC bolted to truss R-30 Un-faced F/G Batts R-30 Un-faced F/G Batts with 2 Rigid Foam 7/16 OSB w/ FR Deck 5/8 Fire Treated Plywood Sheathing with ¼ Dens Deck.045 EPDM Rubber Roof (Black).060 EPDM Rubber Roof (White) TPO Roof (White) Shingles Steel 26 Gauge Hi-ribb Steel Aluminum J-rail along length with site installed aluminum gutters ½ Textured Pre-finished Gypsum Ceiling Board 5/8 Gypsum with Popcorn Finish 5/8 Gypsum with Knockdown Finish 2 x 2 Acoustic Ceiling Armstrong Cortega

Windows: Type: 24 x 54 Bronze Aluminum S/H V/S 3/0 x 4/0 White Vinyl Framed S/H V/S Glazing: Low E Double Insulated Glass Vinyl Covered Wood Return & Casing Wood Painted Return & Casing Blinds: 1 Vinyl Mini Blinds 1 Aluminum Mini Blinds Interior Doors: 3/0 x 6/8 Hollow Core Pre-finished Wood grain 3/0 x 6/8 Solid Core Pre-finished Imperial Oak Size / Type: 3/0 x 6/8 Solid Core Six Panel White 3/0 x 6/8 Solid Core Paint Grade - Painted 3/0 x 6/8 Solid Core Stain Grade - Stained Frame: Wood Prefinished Jamb Steel Redi-frame painted Hinges & Door Upgrade Levers: Lever Set Grade 2 Lever Set Grade 1 Exterior Doors: Size / Type: 3/0 x 6/8 Pre-hung 20 Gauge Steel Door with 18 Gauge Steel Frame 6 x 30 VB 6/0 x 6/8 Bronze Aluminum Frame Storefront Hinges & Door Upgraded Closer: Door Closer, Tell #12641 (Grade 2) or Equal Panic Bar: Panic Hardware, Tell #8300BE (Grade 2) or equal Levers: Lever Set Grade 2 Lever Set Grade 1 HVAC: Wall Mount Air Conditioner (60 Hz) Green Equipment / Refrigerant R-410A 9.0 EER Wall Mount Wall Mount Air Conditioner Step Capacity Green Refrigerant R-410A up to 15.3 IPLV Equipment / Roof Mount Electric 3.0-5.0 Ton with 10 KW Heat Strip Supply / Return F/G in Ceiling with adjustable diffusers Thermostat 7-Day Programmable Heat / Cool

Plumbing: PVC & CPVC Pipe and Fittings Supply: Type L Copper Pipe and Fittings PE Pipe and Fittings Waste: Schedule 40 PVC Pipe and Fittings Lavatory: ADA Accessible Wall Hung China with Lever Faucets Toilet: Low Consumption Elongated Bowl ADA Compliant Low Consumption Child Height Bowl Daycare Urinal: Low Consumption Vitreous China Urinal: Zero Water Zero Flush Bar Sink: 15 x 15 SS Sink with Gooseneck Faucet Kitchen Sink: 22 x 33 SS Double Bowl with Single Lever Faucet Water Cooler: Wall Mounted Bi-level Water Cooler Water Heater: Single Point On Demand Electric Water Heater Tank Type with Plastic Water Pan Compact Tank Type with Plastic Water Pan Restroom Accessories: TP Holder: Single Roll Toilet Paper Holder Soap Dispenser: Surface Mounted Soap Dispenser Paper Towel: Surface Mounted Paper Towel Dispenser Mirror: 18 x 30 Framed Mirror Grab Bars: SS Grab Bar Urinal Screen: Wall Mounted Enameled Steel Partitions: Enameled Steel Modesty Partitions Electrical: 120/240V Single Phase 3 Wire Service: 120/208V Three Phase / 4 Wire Panel: Cutler Hammer or Equal Surface Mount Diffused Fluorescent T-8 with Lights: Electronic Ballast 2 x 4 Four Tube Grid Mounted Fluorescent T-8 Raceway: Romex / MC Cable, Per NEC Code (#12A AWG Minimum) Receptacles: 120V/15A Duplex White and GFCI near HVAC per code Switch: 120V/15A White Toggle switch Exit Light: Vandal Resistant Wall Light

Emergency: Voice / Data / Security: Fire Alarm: Countertop: Cabinetry: Electrical cont.: Dual Head Emergency / Exit Light with 90 Minute Battery Back-up Locations w/single Gang Boxes and ½ Empty Conduit above Ceiling or Below Floor Locations w/single Gang Metal Boxes and ½ EMT Conduit to Above Ceiling for Equipment Millwork: HPL over MDF Board HPL over Plywood HPL over MDF Board (34 Base Cabinets and 30 Wall Cabinets) HPL over Plywood (34 Base Cabinets and 36 Wall Cabinets) Miscellaneous: The specific geographic region and occupancy of the building may require a variance of these specifications. These specifications or equal are use by Affordable Structures and are used for the basis of our preliminary proposal. Actual specifications and material take-offs will be generated with firm proposal.