Evaluation copy. Total Dissolved Solids. Computer INTRODUCTION

Similar documents
Total Dissolved Solids

Evaluation copy. Chloride and Salinity. Computer INTRODUCTION

A Water Field Study. Table 1: Water Temperatures of Selected Rivers Site Season Temperature ( C)

Water Quality Temperature

Turbidity. LabQuest INTRODUCTION

Biochemical Oxygen Demand

LabQuest INTRODUCTION

Acid Rain and Its Effect on Surface Water. Evaluation copy. Figure 1: Typical rain ph in United States.

Ocean Water. Evaluation copy

Evaluation copy. Energy Content of Fuels. computer OBJECTIVES MATERIALS

Dissolved Oxygen. LabQuest INTRODUCTION

Vernier Software & Technology

An Insulated Cola Bottle

Acid Rain. Evaluation copy. Figure 1: Typical rain ph in United States.

Cell Respiration (Method 1 CO 2 and O 2 )

Forensics with TI-Nspire Technology

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

Evaluation copy. Energy Content of Fuels. computer OBJECTIVES MATERIALS

Solar Homes. Evaluation copy. empty bottle with screw-on cap

FINAL REPORT A Mini Grant for Redesigning Lab Experiments for "Chemistry in Society" (ACHM 105) - A General Education Course Kutty Pariyadath

EXPERIMENT 3 SOLIDS DETERMINATION

GRAVIMETRIC DETERMINATION OF SULFATE IN AN UNKNOWN SOLUTION

Write your own lab Spectrophotometry/Colorimetry

Standard Methods for the Examination of Water and Wastewater

Electrical Conductivity/Salinity Fact Sheet

ENGI Environmental Laboratory. Lab #2. Solids Determination. Faculty of Engineering & Applied Science

Oxygen Demand, Chemical

Archer G11 Partner: Judy Aug Gravimetric Analysis of a Metal Carbonate

Evaluation copy. Energy Content of Fuels. computer OBJECTIVES MATERIALS

Copper Odyssey. Chemical Reactions of Copper

Experiment 3: Determination of an Empirical Formula

Oxygen Demand, Chemical

Dissolved Oxygen Probe (Order Code: DO-BTA)

Total Dissolved Solids Dried at 180ºC. Total Volatile Dissolved Solids at 550 C

Gravimetric Analysis: Determination of % Sulfur in Fertilizer

seven mm screw top bottles Vernier computer interface shallow pan Vernier Dissolved Oxygen Probe scissors Logger Pro

SOP-C-130 Determination of Total Solids and Percent Solids

Module 2, Add on Lesson Conductivity Sensor. Student. 90 minutes

Module 2, Add on Lesson Conductivity Sensor. Teacher. 90 minutes

EXPERIMENT 7A. Chemical Separation by Filtration and Recrystallization INTRODUCTION

How to Collect Your Water Sample and Interpret the Results for the Livestock Analytical Package

Dry matter content and fibre content

CHM Gravimetric Chloride Experiment (r7) 1/5

Water Quality. CE 370 Lecture 1. Global Distribution of Earth s s Water

Evaluation copy. Biodiversity and Ecosystems. computer OBJECTIVES MATERIALS PROCEDURE

Advanced Water Quality Monitoring and Analysis Life Science: Grades 7-12

Module 2, Add on Lesson Turbidity Sensor. Teacher. 90 minutes

EXPERIMENT 5 Chemistry 110 COMPOSITION OF A MIXTURE

Salinity in Seawater

SOP-C-109 Determination of Filterable Residue

Chapter 8. Gravimetric Analysis

5 WATER. (iii) Temporary hard water (iv) Permanent hard water

Salinity in the Central Valley

Module 2, Add on Lesson Turbidity Sensor. Student. 90 minutes

Environmental Chemistry - Water HL

TESTING THE WATERS HOW GOOD IS THAT BOTTLED WATER AND HOW EFFECTIVE IS YOUR WATER FILTER

8/11/2015 BY KOREE POMPEY

Acidity and Alkalinity:

Santa Rosa Creek Water Quality Results 2004

Know What You re Monitoring! Since not all of us are water chemists, here is a brief understanding of what your different tools measure

University-level STEM Experiment: Recycling Cans to Alum The Ohio State University ENG Spring 2015 Taylor Ourada, Mary Scherer, Ramon

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Introduction to Water Quality Monitoring Life Science: Grades 4-8

Methods and Materials Manual Of Ion Chromatography Using DX-100 IC. Collecting Samples. LDPE bottle with cap (pre-rinsed with DI water)

There are a number of steps in the treatment of water to ensure supplies are clean and safe.

Lab #4 Gravimetric Analysis of a Metal Carbonate (adapted from Flinn Scientific ChemFax, 2005)

INTERDISCIPLINARY INVESTIGATION (IDI)-LAB LABORATORY HANDOUT

Pennsylvania Senior Environment Corps. Table of Contents Part 2 Getting Started:. 21 Chemical Analysis... 22

Chemistry. Freezing and Melting of Water ID: By Texas Instruments TEACHER GUIDE

INTRODUCTION TO ELECTROCHEMISTRY: CURRENT, VOLTAGE, & BATTERIES. Introduction. Electrochemistry Revised 4/28/14

Sulfate. USEPA 1 SulfaVer 4 Method 2 Method to 70 mg/l SO 4. Powder Pillows. Test preparation. Before starting.

POLLUTION SECTION 7-TESTING FOR HARD WATER From Hands on Science by Linda Poore, Westminster College

Water Desalination and Its Techniques

Interpreting Irrigation Water Quality Reports

Q1. The chemical compositions of two samples of hard water, A and B, are shown in the table.

BOD/CBOD, TSS ph OPERATOR BASICS. Presented by: Marcy Bolek - Alloway

COPPER CYCLE EXPERIMENT 3

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

Hard water. Hard and Soft Water. Hard water. Hard water 4/2/2012

Laboratory Fee Schedule

Drinking Water Treatment

Total Dissolved Solids by Gravimetric Determination

Chemical Testing of Drinking Water

Nutrient Cycling in an Aquatic Ecosystem

Where Does Our Drinking Water Come From?

Water Chemistry. Water 101

Activity of metals SCIENTIFIC. Demonstration and Inquiry. Introduction. Concepts. Background. Inquiry Approach. Demonstration Questions

SCHOOL CHEMICALS FROM SCRAP COKE COLA CANS AND CALCIUM CARBIDE-WATER REACTION RESIDUE

Experiment: Measurements

Cu (s) Cu 2+ (aq) Cu(OH) 2 (s) CuO (s) Cu 2+ (aq) Cu (s)

P-006 Subsampling Water Samples in the Field. Revision 1.0

EUTROPHICATION. Student Lab Workbook

DETERMINATION of the EMPIRICAL FORMULA

Salinity Sensor PS Salinity Sensor Probe. Salinity Sensor Probe, 10 X, Conductivity/Temperature PASPORT Extension Cable

Salinity. sulphate, SO 4

3.0 DETECTION LIMIT 3.1. See Procedure ALQAP Procedure for the Determination of Uncertainty

PHYSICAL CHANGE OR CHEMICAL CHANGE?

Analysis of Calcium Carbonate Tablets

Finding the Salt Front

How to Collect Your Water Sample and Interpret the Results for the Poultry Analytical Package

Transcription:

Total Dissolved Solids Computer 12 INTRODUCTION Solids are found in streams in two forms, suspended and dissolved. Suspended solids include silt, stirred-up bottom sediment, decaying plant matter, or sewage-treatment effluent. Suspended solids will not pass through a filter, whereas dissolved solids will. Dissolved solids in freshwater samples include soluble salts that yield ions such as sodium (Na + ), calcium (Ca 2+ ), magnesium (Mg 2+ ), bicarbonate (HCO 3 ), sulfate (SO 2 4 ), or chloride (Cl ). Total dissolved solids, or TDS, can be determined by evaporating a pre-filtered sample to dryness, and then finding the mass of the dry residue per liter of sample. A second method uses a Vernier Conductivity Probe to determine the ability of the dissolved salts and their resulting ions in an unfiltered sample to conduct an electrical current. The conductivity is then converted to TDS. Either of these methods Sources of Total Dissolved Solids yields a TDS value in units of mg/l. The TDS concentration in a body of water is affected by many different factors. A high concentration of dissolved ions is not, by itself, an indication that a stream is polluted or unhealthy. It is normal for streams to dissolve and accumulate fairly high concentrations of ions from the minerals in the rocks and soils over which they flow. If these deposits contain salts (sodium chloride or potassium chloride) or limestone (calcium carbonate), then significant concentrations of Na +, K +, Cl will result, as well as hard-water ions, such as Ca 2+ and HCO 3 from limestone. Hard-Water Ions - Ca 2+ - Mg 2+ - HCO 3 Fertilizer in agricultural runoff + - NH 4 - NO 3 3 - PO 4 2 - SO 4 Urban runoff - Na + - Cl Salinity from tidal mixing, minerals, or returned irrigation water - Na + TDS is sometimes used as a watchdog - K environmental test. Any change in the ionic + - Cl composition between testing sites in a stream can quickly be detected using a Conductivity Probe. Acidic rainfall TDS values will change when ions are introduced to - H + water from salts, acids, bases, hard-water minerals, - NO 3 or soluble gases that ionize in solution. However, the - SO 2 2 3, SO 4 tests described here will not tell you the specific ion responsible for the increase or decrease in TDS. They simply give a general indication of the level of dissolved solids in the stream or lake. Further tests described in this book can then help to determine the specific ion or ions that contributed to changes in the initial TDS reading. Evaluation copy There are many possible manmade sources of ions that may contribute to elevated TDS readings. Fertilizers from fields and lawns can add a variety of ions to a stream. Increases in TDS can also result from runoff from roads that have been salted in the winter. Organic matter from wastewater treatment plants may contribute higher levels of nitrate or phosphate ions. Treated wastewater may also have higher TDS readings than surrounding streams if urban drinking water has been highly chlorinated. Irrigation water that is returned to a stream will often have higher concentrations of sodium or chloride ions. Acidic rainwater, with dissolved gases like CO 2, NO 2, or SO 2, often yields elevated H + ion concentrations. Water Quality with Vernier 12-1

Computer 12 If TDS levels are high, especially due to dissolved salts, many forms of aquatic life are affected. The salts act to dehydrate the skin of animals. High concentrations of dissolved solids can add a laxative effect to water or cause the water to have an unpleasant mineral taste. It is also possible for dissolved ions to affect the ph of a body of water, which in turn may influence the health of aquatic species. If high TDS readings are due to hard-water ions, then soaps may be less effective, or significant boiler plating may occur in heating pipes. Expected Levels TDS values in lakes and streams are typically found to be in the range of 50 to 250 mg/l. In areas of especially hard water or high salinity, TDS values may be as high as 500 mg/l. Drinking water will tend to be 25 to 500 mg/l TDS. United States Drinking Water Standards 1 include a recommendation that TDS in drinking water should not exceed 500 mg/l TDS. Fresh distilled water, by comparison, will usually have a conductivity of 0.5 to 1.5 mg/l TDS. Table 1: TDS in Selected Rivers Site Season TDS Season TDS Rio Grande River, El Paso, TX Spring 510 Fall 610 Mississippi River, Memphis, TN Spring 133 Fall 220 Sacramento River, Keswick, CA Spring 71 Fall 60 Ohio River, Benwood, WV Spring 300 Fall 143 Hudson River, Poughkeepsie, NY Spring 90 Fall 119 Summary of Methods Method 1: TDS Using a Conductivity Probe A Vernier Conductivity Probe is used on site, or placed into samples collected at sites, to measure TDS concentration of the solution. It offers the advantage that it can be performed without filtration, providing instantaneous feedback about total dissolved solids concentration in a stream. Method 2: TDS By Evaporation Using this method, samples are first filtered to remove suspended solids. A precise amount of sample is added to a carefully cleaned, dried, and weighed beaker. The water is then evaporated in a drying oven. The difference in mass between the two weighings is the mass of the total dissolved solids. Calculations are then performed to convert the change in mass to mg/l of TDS. This procedure does not require a sensor, but does require an analytical balance (0.001 or 0.0001 g resolution). 1 Established by 1986 Amendments to the Safe Drinking Water Act 12-2 Water Quality with Vernier

Total Dissolved Solids Method 1: TDS USING A CONDUCTIVITY PROBE Materials Checklist computer Vernier computer interface Logger Pro Vernier Conductivity Probe 500 mg/l TDS standard solution wash bottle with distilled water tissues or paper towels small paper or plastic cup (optional) 50 mg/l TDS standard solution (optional) Collection and Storage of Samples 1. This test can be conducted on site or in the lab. A 100 ml water sample is required. 2. It is important to obtain the water sample from below the surface of the water as far away from shore as is safe. If suitable areas of the stream appear to be unreachable, samplers consisting of a rod and container can be constructed for collection. Refer to page Intro-4 of the Introduction of this book for more details. 3. If the testing cannot be conducted within a few hours, place the samples in an ice chest or a refrigerator. Testing Procedure 1. Position the computer safely away from the water. Keep water away from the computer at all times. 2. Prepare the Conductivity Probe for data collection. a. Plug the Conductivity Probe into Channel 1 of the Vernier interface. b. Set the switch on the probe box to the 0-2000 µs/cm range (2000 µs/cm = 1000 mg/l TDS). 3. Prepare the computer for data collection by opening the file 12 Tot Dissolved Solid from the Water Quality with Vernier folder of Logger Pro. 4. You are now ready to calibrate the Conductivity Probe. If your instructor directs you to use the calibration stored in the experiment file, then proceed to Step 5. If your instructor directs you to perform a new calibration for the Conductivity Probe, follow this procedure: First Calibration Point a. Choose Calibrate CH1: Conductivity from the Experiment menu and then click. Water Quality with Vernier 12-3

Computer 12 b. Perform the first calibration point with the probe in the air (e.g., out of any solution). c. Type 0 in the edit box. d. When the displayed voltage reading for Reading 1 stabilizes, click. Second Calibration Point e. Place the Conductivity Probe into the 500 mg/l TDS standard solution. The hole near the tip of the probe should be covered completely. f. Type 500 (the concentration in mg/l TDS) in the edit box. g. When the displayed voltage reading for Reading 2 stabilizes, click, then click. 5. You are now ready to collect TDS concentration data. a. Rinse the probe tip with distilled water. b. Place the tip of the probe into the stream, or into a cup with sample water from the stream. The hole near the tip of the probe should be completely covered. a. Click to begin data collection. c. Click to begin a 10 s sampling run. Important: Leave the probe tip submerged for the 10 seconds that data is being collected. d. When the sampling run is complete, stop data collection and record the mean TDS value on the Data & Calculations sheet. 6. Return to Step 5 to obtain a second reading. 12-4 Water Quality with Vernier

Total Dissolved Solids DATA & CALCULATIONS Method 1: TDS Using a Conductivity Probe Stream or lake: Time of day: Site name: Site number: Date: Column Reading A TDS 1 2 Average Column Procedure: A. Record the TDS value (in mg/l) from the computer. Field Observations (e.g., weather, geography, vegetation along stream) Test Completed: Date: Water Quality with Vernier 12-5

Computer 12 Method 2: TDS BY EVAPORATION Materials Checklist sampling bottles drying oven one 600 ml beaker for filtration container 100 ml graduated cylinder large funnel (>10 cm diameter) two 250 ml beakers filter paper to fit large funnel milligram balance (0.001 g) tongs or gloves to hold beaker Collection and Storage of Samples 1. This test can be conducted on site or in the lab. Collect a 500 ml water sample per site so that you can run two 200 ml trials. Note: If your stream or lake could have low levels of TDS, then collect a larger sample volume (see Step 6 of the Testing Procedure). 2. It is important to obtain the water sample from below the surface of the water as far away from shore as is safe. If suitable areas of the stream appear to be unreachable, samplers consisting of a rod and container can be constructed for collection. Refer to page Intro-4 of the Introduction of this book for more details. 3. If samples cannot be tested immediately upon returning to the lab, they should be refrigerated until the time of analysis to avoid microbiological decomposition of solids. Samples should not be tested after seven days. Testing Procedure Day 1 1. Filter any solid particles or suspended solids from your sample. a. Set up a funnel and funnel support on a ring stand. Place a 600 ml beaker or other large container below the funnel. b. Place a folded piece of filter paper in the funnel and moisten it with distilled water so that it adheres to the funnel sides. c. Slowly add your 500 ml sample to the funnel, being sure not to let the level of liquid in the funnel go above the top of the filter paper. Continue adding your sample to the funnel until you have more than 400 ml of filtrate in the beaker below the funnel. 2. Prepare two 250 ml beakers for drying and sample evaporation. a. Carefully clean two 250 ml beakers and place them in a 100105 C drying oven for one hour to dry. b. Remove the beakers from the oven. Allow them to cool. c. Using a pencil, number your beakers 1 and 2. Do not use tape. d. From this point on, always handle the beakers with tongs or gloves to prevent the oils on your hands from affecting their mass. Weigh each beaker on a milligram balance to the nearest 0.001 g. Record the data on the Data & Calculations sheet. e. If you complete Step 2 before collecting samples, leave the beakers in a clean, dry, dust-free space until you return to the lab. 12-6 Water Quality with Vernier

Total Dissolved Solids 3. Transfer the samples to the beakers. a. Using a 100 ml graduated cylinder, carefully measure 200.0 ml of filtered sample water into each beaker. b. Place the remaining sample water into a refrigerator for possible future use. 4. Using tongs or gloves, place the beakers into the oven and allow the water to evaporate overnight at 104 C. Day 2 5. Measure the mass of the beakers and solids. a. Using tongs or gloves, remove the beakers from the oven and place them in a dessicator, if available, to cool. A dessicator will keep the samples from absorbing any water from the air that would increase their mass. If no dessicator is available, the beakers can be cooled on a table top. Proceed to the next step as soon as possible to minimize any absorption of water. b. Use an analytical balance to measure the mass of each beaker with the solids now left behind. Record the values on the Data & Calculations sheet (round to the nearest 0.001 g). c. Obtain the mass of the solids by subtracting the mass of the empty beaker from the mass of the beaker with Cool sample in a the solids. If the mass of the solids is at dessicator, if available. least 0.025 g, proceed to Step 7. If the mass of the solids is less than 0.025 g, proceed to Step 6. 6. If the mass of the solids is less than 0.025 g, add another 200.0 ml of sample to each beaker and repeat Steps 4 and 5. Make a note on the Data & Calculations sheet that your total volume is now 400.0 ml instead of 200.0 ml. 7. Record the mass of each beaker plus the solids on the Data & Calculations sheet. 8. Soak the beakers in hot soapy water. Water Quality with Vernier 12-7

Computer 12 DATA & CALCULATIONS Method 2: TDS by Evaporation Stream or lake: Site name: Site number: Date: Time of day: Column A B C D E F Beaker Number Mass of empty beaker (g) Mass of beaker plus solids (g) Mass of solids (g) Mass of solids (mg) Total volume (L) TDS Example 95.245 g 95.277 g 0.032 g 32 mg 0.200 L 160 mg/l 1 2 Average TDS Column Procedure: A. Mass of empty beaker B. Mass of beaker with dried solids C. Mass of solids (g) = B A D. Mass of solids (mg) = C 1000 E. Total volume (L) = ml water / 1000 F. TDS = D / E Field Observations (e.g., weather, geography, vegetation along stream) Test Completed: Date: 12-8 Water Quality with Vernier

Vernier Lab Safety Instructions Disclaimer THIS IS AN EVALUATION COPY OF THE VERNIER STUDENT LAB. This copy does not include: Safety information Essential instructor background information Directions for preparing solutions Important tips for successfully doing these labs The complete Water Quality with Vernier lab manual includes 16 water quality tests and essential teacher information. The full lab book is available for purchase at: http://www.vernier.com/cmat/wqv.html Vernier Software & Technology 13979 S.W. Millikan Way Beaverton, OR 97005-2886 Toll Free (888) 837-6437 (503) 277-2299 FAX (503) 277-2440 info@vernier.com www.vernier.com