Product Guide. The smart way to Meet Regulations. Be Safe. Be Secure. SoundSecure - Secured by Design FD30 & FD60 Internal Apartment Entrance Doorsets

Similar documents
Product Guide Meet Regulations. Be Safe. Be Secure.

Contents Introducing SoundSecure product features technical specifications range summary important information

Exterior folding doors

General Product & Quality Specification

General Product & Quality Specification

DOORS COLLECTION Leading the way in quality

General Product & Quality Specification

subtle form perfect function Quadra & Una Riser door systems Detailed product guide BIM L D11/1 [31.59] X Uniclass EPIC CI/SfB

General Product & Quality Specification

General Product & Quality Specification

DURBAN Pelican Systems (Pty) Ltd 765/793 North Coast Rd PO Box 4060 Redhill 4071 Tel: (+27)

WELCOME TO FIREDOORS VALUE ADDED SERVICES. Fresh new designs and finishes to highlight your project.

Operating & Maintainence Orca doors: Intego

Installation & Maintenance Guidelines. Contents

Fire/Smoke & Acoustic Letterplate System

High Performance Joinery Products for Scotland

DESIGN DOORS TEL:

DESIGN DOORS TEL:

Cl/SfB (31.5) Uniclass L411 April Sentinel. making hands safe. making hands safe. Sentinel THE HAND AND FINGER PROTECTION SOLUTION FOR DOORSETS

Quality manufacturer of Doors / Pre-hung doorsets / Screens and Cubicle washroom systems

Innova: Inward-opening concealed frame doorsets

ANTIK DOORS. The Antik series combines a traditional look with modern design. Beautiful, stylish doors that will add character to your home.

CERTIFICATE OF APPROVAL No CF 302 PREMDOR CROSBY LIMITED

OPEN UP. The DUO Contemporary Composite Door. a world of new possibilities

CERTIFICATE OF APPROVAL No CF 535 HALSPAN LIMITED

CERTIFICATE OF APPROVAL No CF 302 PREMDOR CROSBY LIMITED

CERTIFICATE OF APPROVAL No CF 385 HOLLWAYS DOORS & FRAMES LIMITED

CERTIFICATE OF APPROVAL No CF 395 EUROPEAN WOOD PRODUCTS LIMITED

Save space enhance style. Enigma. Pocket sliding door systems. Detailed product guide BIM L D11/1 [31.59] X. Uniclass EPIC.

Timber Veneer & Laminate Doors, Panels and Doorframes

Save space enhance style. Enigma. Pocket sliding door systems. Detailed product guide BIM. Patent pending L D11/1 [31.59] X.

COST EFFECTIVE DOOR SOLUTIONS

The Royale Collection Aluminium windows and doors

INNA-DOR. Stylish, contemporary and durable internal doorsets FIRE DOORS ACOUSTIC REDUCTION. Available with 60, 120 and 240 mins fire protection

CERTIFICATE OF APPROVAL No CF 5158 WHITE ALUMINIUM ENTERPRISES L.L.C.

Colourline, Silverline & Timberline

CERTIFICATE OF APPROVAL No CF 820 ZMR LTD TRADING AS MILLENNIUM DOOR SYSTEMS

CERTIFICATE OF APPROVAL CERTIFICATE No CF 633 PUERTAS NORMA S.A.

CERTIFICATE OF APPROVAL No CF 538 G E DOOR MANUFACTURING LTD

CERTIFICATE OF APPROVAL No CF454 VICAIMA LIMITED

Experts in Mental Health

Fire Door Installation

CERTIFICATE OF APPROVAL No CF 5372 CORINTHIAN INDUSTRIES (ASIA) SDN BHD

CERTIFICATE OF APPROVAL No CF 535 HALSPAN LIMITED

CERTIFICATE OF APPROVAL No CF 154 J B KIND LIMITED & IRMADE- INDÚSTRIAS DE REVESTIMENTO DE MADEIRAS, S.A.

Contents. About us. Bespoke. Windows. Flush casement windows. Tilt & turn windows. Pivot windows. Passivhaus windows. Doors. Contemporary doors

CERTIFICATE OF APPROVAL No CF 5174 BUILDING LIFE (FIRE DOORS) LTD

CERTIFICATE OF APPROVAL No CF 5003 BUILDING LIFE (FIRE DOORS) LTD

The sleek AOV solution. Fuma. Automatic Opening Vent. Detailed product guide L D11/1 [31.59] X. Uniclass EPIC. CI/SfB. Sustainably sourced

CERTIFICATE OF APPROVAL No CF 572 JELD-WEN UK LIMITED

CERTIFICATE OF APPROVAL No CF 242 GEZE UK LIMITED

why choose anything less

50948-RHN Putney. 16 Jan This document includes: Windows/ Rooflights/ Screens/ Louvres. Code Section Revision Dated

external joinery collection bringing homes to life

Proposed Specification Section FLUSH WOOD VENEER DOORS

CERTIFICATE OF APPROVAL No CF 380 PREMDOR CROSBY LIMITED

CERTIFICATE OF APPROVAL No CF 242 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 218 VICAIMA LIMITED

The sleek AOV solution. Fuma. Automatic opening vent. Detailed product guide L D11/1 [31.59] X. Patent pending. Uniclass EPIC.

Core. Thickness. Karrier Panel Thickness (mm) Weight (Kg/m²)*

CERTIFICATE OF APPROVAL No CF 5320 ZOO HARDWARE LTD

Tailored solutions in timber

SECTION / STC 52 METAL SOUND CONTROL DOORS

Door Systems. Window and Door Systems INNOVATIVE BUILDING SYSTEMS

Retro-fit Solutions for Upgrading Non-compliant Fire Doors

Operating & Maintainence Orca doors: Fortis

Refurbishment site guidance for solid-walled houses windows and doors

ENGINEERED COMPONENT SYSTEM FOR HIGH PERFORMANCE FIRE DOOR ASSEMBLIES

CERTIFICATE OF APPROVAL No CF 198 PREMDOR CROSBY LIMITED

SUPERIOR DOORS. Product. Scope. Building Regulations. Appraisal No. 787 [2012] Appraisal No. 787 (2012) Amended 13 September 2016.

Safe and Secure Solution PRODUCT CATALOGUE

Page 1 1 Bounce chair 1 Bounce chair Bounce chair design by naughtone. Sizes

HOMERIT PREMIUM SERIES PVC-U WINDOWS AND DOORS. Product. Scope. Appraisal No. 543 [2007] Appraisal No. 543 (2007) Amended 21 October 2013

EVOLUTION. Product Data Sheet. Design Wall Series

CERTIFICATE OF APPROVAL No CF 5497 AL HUDA INTERIORS FACTORY LLC

CERTIFICATE OF APPROVAL No CF 242 GEZE UK LIMITED

INTERIOR DOOR SELECTOR 2017/2018

Aluminium SLIDING & BI-FOLD DOOR SYSTEMS

ENGINEERED COMPONENT SYSTEM FOR HIGH PERFORMANCE FIRE DOOR ASSEMBLIES

1 Bounce chair Ped table Bounce chair design by naughtone. Sizes

Joinery Granitehill Road Northfield Aberdeen Scotland AB16 7AW

Sustainable. Glazing. Solutions.

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

CERTIFICATE OF APPROVAL No CF 292 NORMA DOORS TECHNOLOGIES, S.A.

QUIET, WARMTH & STYLE

CERTIFICATE OF APPROVAL No CF 5525 TALLERES DE ESCORIAZA S.A.U

Securefold & Securefold Ultra The ultimate folding door hardware system. Design in motion

Fire/Smoke & Acoustic Letterplate System

CERTIFICATE OF APPROVAL No CF 735 UNITY HARDWARE LTD

SECTION FLUSH WOOD VENEER DOORS

CERTIFICATE OF APPROVAL No CF 5539 HAEFELE GMBH & CO KG

Residential solutions. Steel, aluminium and fire doors

DOORS. hallmark timber veneer doors DOORS CAVITY SLIDERS FIRE DOORS

Core. Thickness. Biological

Northgate s glazed partitioning system has been designed to be virtually frameless with the minimum possible aluminium head and base track

CERTIFICATE OF APPROVAL No CF 5389 FINANCIERA MADERERA SA

September Saddle Flooring Systems

TECHNICAL SPECIFICATION FOR MATERIAL

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

BOURNEMOUTH planter. Street Design Limited Unit 35 Hayhill Industrial Estate Barrow upon Soar Leicestershire LE12 8LD

Transcription:

SoundSecure - Secured by Design FD30 & FD60 Internal Apartment Entrance Doorsets Product Guide The smart way to Meet Regulations. Be Safe. Be Secure. FD30 & FD60 SECURED BY DESIGN INTERNAL APARTMENT ENTRANCE DOORSETS

Introducing FD30 & FD60 SECURED BY DESIGN INTERNAL APARTMENT ENTRANCE DOORSETS SoundSecure - specifically designed to meet the complex demands of internal apartment entrance locations Introducing SoundSecure Available with Certifire approved FD30 and FD60 inward opening fire doors. Fireshield FD30 and Firemaster FD60 doors and intumescent seals ensure that the doorset meets the fire resistance and escape requirements specified by Building Regulations Part B and related National Standards. Traditional timber frame Sound reducing specification that meets the acoustic targets of the Building Regulations Part E and related National Standards (29dB). Secured by Design accredited assembly with durable construction and performance tested ironmongery providing protection against intrusion. Doorset widths suitable for mobility access and low level thresholds assist in meeting the demands of Building Regulations Part M and related National Standards. Where a Secured by Design specification is not required, please ask for a quotation for our non-secured By Design option. Premdor UK is a division of Masonite, one of the world s leading manufacturers of interior doors and entry door systems. For over 80 years, Masonite has maintained its focus on pioneering innovation, manufacturing excellence and unrivalled customer service. Masonite operates from 55 sites located around the world, serving clients in 70 countries. Secured by Design scan here SoundSecure door and frame assembly meets the Secured by Design scheme requirements and is independently certified and tested within the TRADA Q. Mark Scheme. Premdor holds a SBD licence for this product. Watch our installation videos on YouTube www.youtube.com/premdor BS EN ISO 9001: 2015 Premdor manufacture doors and doorsets that are produced under the disciplined quality management controls of BS EN ISO 9001: 2015. BS EN ISO 14001: 2015 Premdor has achieved BS EN ISO 14001: 2015 accreditation at its manufacturing site in Barnsley. This underlines our environmental credibility and commitment to the continuous improvement of our environmental management system. Premdor is a member of General Specifications FD30 & FD60 SECURED BY DESIGN INTERNAL APARTMENT ENTRANCE DOORSETS 2 Premdor SoundSecure Product Guide

Contents 2 4 5 6 7 Introducing SoundSecure Door Designs & Finishes Additional Product Features Technical Specifications Important Information SoundSecure Benefits Manufactured from timber - a renewable resource, purchased under legal controls and logging disciplines. Engineered components used to improve material stability and reduce waste. Timber can be reprocessed at the end of the product s life. SoundSecure moulded panel door facings are FSC certified. SoundSecure flush door facings are PEFC certified. All SoundSecure doorsets are manufactured within a facility that is BS EN ISO 14001 accredited. Premdor SoundSecure Product Guide 3

SoundSecure Options Door Designs and Finishes SoundSecure doorsets are available with any standard flush door or moulded panel design. Both flush and moulded designs feature a three layer high density partical board core, with concealed hardwood lippings on the long edges of the doors. 2 panel smooth 2 panel arch top textured 4 panel arch top textured 4 panel smooth & textured 6 panel smooth & textured 1 panel smooth Ladder moulded Horizontal 4 line smooth Vertical 5 panel moulded Ash veneer Koto veneer North American Maple veneer Sapele veneer Beech veneer Walnut veneer Anegre White oak veneer Innova Popular paint grade Paint grade plus Oak vertical Ash vertical Walnut vertical Durador vertical Oak two stile Walnut two stile Charcoal grey vertical Charcoal grey Charcoal grey four line Light grey Light grey two stile Light grey four line Light grey vertical four line Black & Light grey two stile Mocha Scandanavian Scandanavian two stile Ebony vertical Wenge vertical Moulded Panel Doors Moulded panel doors incorporate FSC TM certified quality facings to offer excellent appearance and performance. All door faces have a white base coat ready for prompt on site finishing. Please note that base coat and priming do not seal the door fully against moisture penetration on site. Flush Doors Flush doors incorporate PEFC certified veneered faces to offer top quality appearance and performance.veneered door faces are fully finished (excluding Popular Paint Grade and Paint Grade Plus) with lacquer to give a beautifully smooth hard wearing and wipe clean surface. Door thickness is 44mm Door thickness is 54mm 4 Premdor SoundSecure Product Guide

Additional Product Features Door Frames FD30 doors are factory hung in an engineered softwood door frame. FD60 doors are hung in a paintgrade hardwood frame only. Locking System High quality, Secured by Design, police approved, modern three point espagnolette locking system, complete with chrome lever handles. The standard lock and handles provided can be used in both solid or split spindle modes. The locks are fitted with a fire escape (thumb turn) key cylinder as standard. Seals Smoke and intumescent seals incorporated at the frame head and jambs as standard. Acoustic seals fitted to all four edges. All doorsets acoustically rated at 29dB. Hinges Doors are hung on three brushed chrome CE marked steel security hinges. Threshold An under door drop seal is fitted as standard in conjunction with a floor level threshold plate. Optional Extras FD30 / FD60 fire resistant chrome effect letterplate and silver security cowl. 15mm hardwood threshold strip. Mobility height eye viewer. Silver handles, letterplate and security chain instead of chrome. Standard Ironmongery All doorsets are supplied with a Secured by Design, police approved, 3 point espagnolette lock with an anti bump EuroProfile lock cylinder incorporating an internal thumb turn. All cylinders are fully protected from attack by a high specification cylinder guard. Lever handles are available in chrome (or optional silver) and can be fitted for use in either solid or split spindle modes. A chrome 180 vision frog eye security eye viewer is supplied as standard. In addition, a chrome (or optional silver) security door chain is included to complement the system, compliant to TS003. Chrome Handles & Thumb Turn Key Cylinder (Silver option available) Chrome Security Eye Viewer (mobility or standard location option) * Images are for illustration purposes only. Actual product may vary. Chrome Security Chain TS003 Compliant (Silver option available) Optional* Silver or Chrome Effect Fire Rated Letterplate and silver security cowl. (Cowl must be fitted with the letterplate). TS008 Security version available upon request. Premdor SoundSecure Product Guide 5

Technical Specifications Hinges Three CE marked brushed chrome security hinges. Smoke / Acoustic Seal Norsound Large 710 seal in timber frames. Threshold Plate Intumescent Seal FD30 25mm x 4mm strip FD60 15mm x 4mm strip (x2no) Under Door Threshold Plate / Automatic Dropseal Extruded aluminium threshold and variable height dropseal has a new, higher efficiency mechanism which lifts the seal clear of the floor as soon as the door is opened by a few millimetres. The seal is self-levelling when fitted with the under door threshold will accommodate an under door gap of up to 12mm. This threshold seal has passed a 100,000 cycle test with ease. Door Widths Building Regulations Part M demand specific dimensions for doors and corridors, which have been calculated to assist the mobility of wheelchairs and prams into, and within, the dwelling. These details are shown in the diagram and table below. Automatic Dropseal Clear opening dimensions for doors are determind by a number of components, the table below summarises this information by door size: Door Width Clear Opening FD30 Overall Frame Size Bickwork Opening Clear Opening Overall Frame Size Bickwork Opening FD30 FD30 FD30 FD60 FD30 FD30 914mm x 1981mm 44mm 851mm 998mm x 2036mm 1008mm x 2046mm 54mm 838mm 986mm x 2030mm 996mm x 2040mm 864mm x 1981mm 44mm 801mm 948mm x 2036mm 958mm x 2046mm 54mm 788mm 936mm x 2030mm 946mm x 2040mm 838mm x 1981mm 44mm 775mm 922mm x 2036mm 932mm x 2046mm 54mm 762mm 910mm x 2030mm 920mm x 2040mm 926mm x 2040mm 44mm 863mm 1010mm x 2095mm 1020mm x 2105mm 54mm 850mm 998mm x 2089mm 1008mm x 2099mm (Based on a 18mm stop, 7mm hinge throw and a 3mm edge gap.) Clear Opening Door Handing Clear Opening Inside Property Left Hand Hinged (LHH) Right Hand Hinged (RHH) Outside Property SoundSecure Doorsets are handed viewed from outside the property and are inward opening. 6 Premdor SoundSecure Product Guide

Building Regulations The below is offered as guidance based on Building Regulations requirements at the time of going to press. Always check specific project requirements against Building Regulations specifications prior to ordering. If in doubt, please contact Premdor. Conservation of Fuel and Power Building Regulations Part L / Scotland Technical Standards Part J / Northern Ireland Building Regulations Part F. Mobility Access and Facilities for the Disabled - Building Regulations Part M / Northern Ireland Building Regulations Part R SoundSecure doorsets are available in a variety of door widths to meet the regulations and specific project requirements. Please note that these regulations include specific requirements such as unobstructed space on the opening side of the door, and the location of glazing panels, For full details, please see the regulations. Door Core Specifications PremCor FD30 / FD60 All SoundSecure doorsets are made using PremCor, a high density core material, which requires no timber framing. When correctly installed with suitable intumescent strips, this proven construction will provide certified fire resistant, acoustic and security performance. Moulded Resistance to the Passage of Sound Building Regulations Part E / Scotland Technical Standards Part H / Northern Ireland Building Regulations Part C - SoundSecure doorsets solid core construction exceeds the required weight of 25kg/ m 2 needed to meet these acoustic requirements, providing a minimum sound reduction index of 29dBRw for apartment entrances. Fire Safety Building Regulations Part B / Scottish Technical Standards Part D & E / Northern Ireland Building Regulations Part E - fire door performance and fire escape ironmongery assist compliance with these regulations. SoundSecure doorsets are either FD30 or FD60 and are Certifire approved and tested to BS476 Part 22. Please ensure that you order the correct fire rating. Veneered Secured by Design SoundSecure door and frame assembly meets the Secured by Design scheme requirements PAS24 and is independently certified and tested within the TRADA Q. Mark Scheme. Premdor holds a SBD licence for this product. Where a Secured by Design specification is not required, please ask for a quotation for our non- Secured by Design option. * Images are for illustration purposes only. Actual product may vary. Premdor SoundSecure Product Guide 7

Important Information Storage and Handling SoundSecure doorsets should be stored and handled as prescribed in our storage and handling documentation. Do not store or install in an area which may be subject to extremes of temperature or humidity. Always store in a well-ventilated building. Do not store or install in areas that have been recently plastered. The doorsets should be laid flat and kept dry and clean inside the polythene packaging until immediately before installation. The testing and rapid switching on and off of heating during the construction is detrimental to joinery and should be avoided after the doorset is installed. When stacking doors or frames it is essential that at least three equal thickness bearers are located across the width to evenly distribute weight and avoid damage. Veneered doors should not be exposed to direct sunlight because natural shading or fading may occur. It is important that any packaging material (shrink wrap etc.) is left on the doorset for as long as is practically possible to avoid damage to door surfaces. This is particularly important with fully finished products. Installation Doors should be fitted as prescribed in our installation guide. Do not install in buildings that are damp or which have been recently plastered. It is essential that unfinished doors be fully sealed with paint, immediately after delivery. Timber door frames and unfinished doors should be sealed, knotted and primed immediately, and should then be fully finished, preferably before installation. Edges of flush doors with lacquer finish should be sealed after installation and if any surface is subsequently cut, it should be primed or lacquered before the door is fixed into position. Full fixing installation details are available on request or as a download via the Premdor website. Decorative Finished Products Coated surfaces require regular maintenance and cleaning at least annually to remove surface pollution. Some chalking of the finish may occur over time due to natural erosion of the microporous paint film. This does not detract from the systems protective performance. On occasion timber products may naturally exude resin after installation. Typically, if resin is present this bleeding cannot be prevented, and Premdor are unable to accept liability in this matter. Discolouration can occur which will require attention and maintenance to retain the aesthetics and integrity of the coating. Resin exudation is excluded from our performance guarantee. Exposure conditions can vary significantly according to location. South facing elevations and coastal sites will reduce to some extent the finish life to first maintenance. Our guarantees are intended to cover reasonable average UK conditions. Finishing Interior door decoration should be carried out in accordance with BS 6150: 2006 and BS 8000 Part 5: 1990. Products must be clean and dry prior to finishing, having moisture content that is no greater than the average for the intended location. Always follow the instructions provided with the stain or paint that is to be applied. Where necessary, Shellac knotting may be applied to honey primed door frames to aid resistance to resin staining subsequent to paint finishing. It is important that the finishing system is balanced by equal application to both sides at the same time to ensure that an imbalance of moisture does not occur, particularly in the decoration of doors. The complete surface area should be fully treated with topcoat paint or stain prior to installation. To ensure adequate coverage at least three coats of topcoat paint/stain needs to be applied. All edges, rebates for glazing and any areas which have been cut, drilled, etc. must be fully painted/stained to the same standard as the rest of the door. After Care SoundSecure doorsets can be cleaned using a damp cloth or mild soapy water. Abrasive or industrial cleaning products should not be used. Ironmongery Maintenance At annual intervals or more frequently if necessary, inspect and lubricate all ironmongery, hinges, pivoting and sliding parts. Inspect the condition of the decorative and glazing systems on all joinery at maximum intervals of one year and carry out remedial work as required. Warranties SoundSecure doors and frames are guaranteed for ten years against manufacturing defect. Factory applied decorative finishing carries a five year warranty against manufacturing defects. For the full terms, conditions and exclusions of all Premdor product warranties, please refer to our main Range Guide, or request details. Illustrations Products may be shown with additional, non standard, ironmongery fitted. This is for illustrative purposes only. Specifications may vary from those indicated or illustrated, at our option. Premdor reserve the right to change specifications at any time without notice. To confirm details of particular products please check before ordering. For installation support or further information tel: 0844 209 0008 fax: 0844 371 5333 www.premdor.co.uk Calls cost 1.15ppm, plus your phone companies access charge.