Series 5500 Bellows Pump Connectors Catalog 474E

Similar documents
Series 1500 Laminated Bellows Expansion Joints. Catalog 1103

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

INSTALLATION PROCEDURE

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Lifting Lug Standard on all units, for ease of installation. Multi-Ply Bellows Laminated bellows offer maximum flexibility and endurance ONS

INSTALLATION PROCEDURE

SECTION VIBRATION ISOLATION

Style 206 Product Specification

INSTALLATION PROCEDURE

All definitions are defined according to ANSI/AWWA C

Stainless Steel Aeration Equipment Specification

C. Concrete Inertia Bases: Drawings showing required concrete steel reinforcing, construction details, and dimensions.

Installation Guidelines for Flygt Pumps Pump Anchoring Recommendations

PIPE GUIDES SLIDES AND ANCHORS

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Standard Specification for Circular Metallic Bellows Type Expansion Joint for HVAC Piping Applications 1

INSTALLATION PROCEDURE

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

Style 204 EPS Product Specification

SERIES N1 STOP GATE T AB L E O F CONTENT S. Application and Specification. Installation and Maintenance Instructions. Limited Warranty.

SERIES G1A, G1B & G1C SLIDE GATES

GREEN THREAD Piping Systems

All definitions are defined according to ANSI/AWWA C b. Flanged Joint: The flanged and bolted joint as described in ANSI/AWWA C110/A21.10.

Expansion Joints Guide Module 6 - Low Pressure Expansion Joints General - Standard Program (EFB) - Installation Instructions - Technical Data

Fluid Sealing Association

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Style 204 MAX Product Specification

SERIES W1S & W2S ACCESS COVERS. With Grating Panels

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC PIPES AND TUBES

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

DARTMOUTH COLLEGE DESIGN September 15, 2004 &CONSTRUCTION GUIDELINES

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Technical Data for. Headers. and Beams

SECTION HANGERS AND SUPPORTS FOR PLUMBING

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems

Monolithic Isolation Fittings

CTP STITCH-TIE AGAIN! Quick and easy way to re-anchor existing veneers to back-up structures.

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Your guide to selecting pipe guides, slides and anchors

Installation Instructions/Operation and Maintenance Manual. Models PLG-60 PLG-72. PS DOORS Contact Information. Website psdoors.

SPECIFICATIONS - DETAILED PROVISIONS Section Progressing Cavity Pump C O N T E N T S

SERIES G1G, G1H & G1I SLIDE GATES

RL8000HE/RL8500HE Load Cell Mounting Kit. Installation Guide

ABS and DNV Type Approved Products

Wabo Modular STM and D Series Large movement expansion joint system

SAPAG CHECK VALVES MODEL CLASAR

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Mounting Bases and Vibration Isolation. for Greenheck Centrifugal Fans GREENHECK

GC-X360S-W GC-X360S-B

WALL MOUNTED ARTICULATING JIB CRANE

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

Pallet Gate Installation Instructions and Operators Manual

SINGLE SWING DOOR PAIRED SWING DOOR

SECTION ALUMINUM GATES

ElectroStop. Monolithic Isolation Joints INNOVATIVE ENGINEERING FOR CORROSION PROTECTION

ERS2010 ERSW2010. Users Manual. Seismic Restraint System

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Baffle Wall Panel Products and Fabrications REVISED 11.

SERIES H1W ACCESS COVER. With Grating Panel

MODELS: 475 WM & 475 WMSS

A. ASTM F Standard Specification for Pressure-rated Polypropylene (PP) Piping Systems.

City of Winnipeg BASES, HANGERS AND SUPPORTS Section NEWPCC - Pump Well Isolation Page 1 of 6 Tender No June 2003

Shower Column SHCM Installation Guide

New Advanced Environmental Air Treatment System

Product Specifications MRI Trench Duct

SPECIFICATION FOR SPHERICAL VESSELS (PROJECT STANDARDS AND SPECIFICATIONS)

Global Water Instrumentation, Inc.

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SPECIFICATIONS - DETAILED PROVISIONS Section Horizontal Centrifugal Water Pumps C O N T E N T S

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

SERIES S1R & S2R ACCESS COVERS

LIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES:

CERAM CORE Abrasion Resistant Piping for Power Generation Applications

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS CONSTRUCTION PACKAGE

PEN SEAL. Pipe Penetration Seals

GLOBAL LVL HEADERS, BEAMS AND COLUMNS. 1.9E-2850Fb. 1.9E-2850Fb. User guide User guide. lvlglobal.com

Festoon Manual Heavy Duty C-Track

CR-3000 Car Rotator Capacity 3,000 lbs Installation Manual 2016 Mar

DIVISION 20 GENERAL SECTIONS FOR PLUMBING, FIRE SUPPRESSION & HVAC SECTION VIBRATION ISOLATORS

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted)

SECTION VIBRATION AND SEISMIC CONTROL FOR PLUMBING

Division 15 VIBRATION ISOLATION AND SILENCERS Section Page 1 of 6

Made in U.S.A. Wave Style Bike Rack Submittal Sheet. Materials: 1.5 Schedule 40 Steel Pipe (1.

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal May 1, 2015

DIVISION 15- MECHANICAL Section Fire Pumps

Pre-Fabricated Roof Curbs

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Summit tm Modular Railing System

NOTICE: To the prices and terms quoted, there will be added any manufacturers or sales tax payable on the transaction under any effective statute.

NOTICE: To the prices and terms quoted, there will be added any manufacturers or sales tax payable on the transaction under any effective statute.

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

Diffused Aeration Piping Equipment

Houston First Corporation Package 1

WALL CANTILEVER WORK STATION JIB CRANE

SECTION STRUCTURAL METAL FRAMING

Transcription:

Series 5500 Bellows Pump Connectors Catalog 474E

Series 5500 Bellows Pump Connectors Sizes 1-1 /2 through 24 Design Conditions: full vacuum to 150 and 300 psig at 500 F Compact design with maximum flexibility and extended life Designed specifically to isolate and protect mechanical equipment Series 5500 Bellows Pump Connectors are designed for installation adjacent to mechanical equipment to isolate vibration, absorb small pipe movements and to provide flexibility during installation. The bellows element is laminated (3 ply minimum) for maximum flexibility and fatigue resistance. Standard configurations include integral full thrust limit rods to react the full pressure thrust or compression for vacuum conditions. This rugged product is designed for the most demanding industrial applications, or the maximum reliability for HVAC installations. Standard configurations are available from inventory. Consult the factory for non-standard designs involving special materials or design conditions. Type 5501R Bellows Pump Connectors installed on nitric acid pump. Applications Bellows pump connectors are designed to connect rigid piping to mechanical equipment that has thermal growth or mechanical movement. Although limit rods are an integral part of the design to prevent over extension or compression, these rods should be installed loose for full benefit. The rigid anchor shown in the illustration must be capable of reacting the pressure thrust and the spring force of the bellows. Series 5500 Bellows Pump Connectors installed on the suction and discharge of a pump. Rigid Anchor Pressure Thrust* Spring Rate (lbs./in.) Axial Travel = + X Force (lbs) Force (lbs.) Table 2 Column 4 Table 2 or 3 (inches) *Use maximum pressure including test pressure. 2 Copyright 2005 Hyspan Precision Products, Inc. Printed in the USA

Design Features Flow Liners Flow liners or internal sleeves are optional features on standard Series 5500 Bellows Pump Connectors. Their purpose is to: minimize pressure loss, prevent bellows resonance in turbulent flow, prevent erosion of the bellows if the media contain abrasive material or to prevent direct impingement of high temperature flow on the bellows. The guidelines published by the Standards of the Expansion Joint Manufacturers Association, Inc. are: flow liners are recommended for gas flow with velocities exceeding 4 ft./sec. per inch of diameter through 6 NPS, and 25 ft./sec. for sizes larger than 6 NPS. For liquid flow, liners are recommended for velocities exceeding 2 ft./sec. per inch of diameter through 6 NPS, and over 10 ft./sec. for sizes over 6 NPS. If extremely turbulent flow conditions exist, the actual flow velocity should be multiplied by 4 to use these criteria. Series 5500 flow liners are designed for unidirectional flow, and flow conditions normally experienced in industrial and HVAC applications. For conditions involving bi-directional flow, high velocities, abrasive materials or extreme turbulence, consult the factory. Table 1 Allowable Movements Bellows Pump Connectors, Types 5501R & 5502R 150 & 300 psig Allowable Movements - inches Nominal Sizes (NPS) 1 1 /2"-8" 10"-16" 18"-24" Axial Compression 0.50 0.75 1.00 Axial Extension 0.25 0.25 0.25 Installation Offset 0.13 0.13 0.13 Offset is measured from the centerline Series 5500 3

5501R Fixed Flange 5502R Van Stone Flange Typical End View Flanges: Flat face carbon steel made from ASME A-36 plate with integral limit rod lugs. Outside diameter and drilling per ASME/ANSI B16.5. Table 3 designs 150 lb. drilling, Table 4 designs 300 lb. drilling. See Column 5 of Tables 3 & 4 for maximum outside dimension including limit rod lugs. Bellows: Laminated (multiply) ASTM A240 type 321 3 diameter and under, type 304 over 3 diameter. Van Stone: ASTM A240 type 304, The primary purpose of van stoned ends on Series 5500 Bellows Pump Connectors is to provide an all wetted stainless steel surface in contact with the flow media. The van stone is material that is flared and flattened against the flange face. Although it is not dimensionally equivalent to a raised face, it creates a condition that is comparable. Since the flanges are not attached to the bellows or van stone, they can rotate relative to each end approximately one half hole diameter as limited by the limit rods. Flow Liner (optional): ASTM A240 type 304, Material thickness follows the recommendations of the Standards of the Expansion Manufacturers Association, Inc. for flow velocities less than 100 ft./sec. Limit Rods: ASTM A307 Bolts, A563 Nuts Table 2 Pressure and Force Data Bellows Pump Connectors Types 5501R, 5502R & 5506R 150 & 300 psig Nominal Effective Size Area 50 75 100 150 225 300 450 NPS (in. 2) PSI PSI PSI PSI PSI PSI PSI 1 1 /2 3.6 180 270 360 540 810 1080 1620 2 5.6 280 420 560 840 1260 1680 2520 2 1 /2 7.8 390 585 780 1170 1755 2340 3510 3 11.6 580 870 1160 1740 2610 3480 5220 4 19 950 1425 1900 2850 4275 5700 8550 5 28 1400 2100 2800 4200 6300 8400 12600 6 40 2000 3000 4000 6000 9000 12000 18000 8 66 3300 4950 6600 9900 14850 19800 29700 10 101 5050 7575 10100 15150 22725 30300 45450 12 147 7350 11025 14700 22050 33075 44100 66150 14 177 8850 13275 17700 26550 39825 53100 79650 16 229 11450 17175 22900 34350 51525 68700 103050 18 287 14350 21525 28700 43050 64575 86100 129150 20 355 17750 26625 35500 53250 79875 106500 159750 24 501 25050 37575 50100 75150 112725 150300 225450 1 2 3 4 5 6 7 8 9 4 Copyright 2005 Hyspan Precision Products, Inc. Printed in the USA

Table 3 Type 5501R, 5502R & 5506R (3) Design Pressure: Full Vacuum to 150 psig. Test Pressure: 225 psig. Design Temperature: 500 F Nominal Part Number Overall Axial Spring Outside Size 5501R Length (1) Rate Diameter (2) Number of Weight NPS 5502R (inches) (lb./in.) (inches) Rods (lbs.) 1 1 /2-127 3.5 360 7.5 3 13 2-131 3.5 435 8.5 3 16 2 1 /2-135 3.5 643 9.5 3 22 3-140 4.0 860 10.0 3 24 4-148 4.5 968 11.5 3 26 5-155 4.5 1168 12.5 3 29 6-160 5.0 1274 14.0 3 40 8-167 5.0 1440 17.0 3 51 10-174 6.0 1619 19.5 3 65 12-180 6.0 1725 23.0 3 91 14-181 8.0 2004 25.5 3 163 16-182 8.0 2220 28.0 3 204 18-183 9.0 2397 30.0 3 245 20-184 9.0 2492 33.0 3 260 24-186 9.0 2819 37.5 4 290 1 2 3 4 5 6 7 Table 4 Type 5501R & 5502R Design Pressure: Full Vacuum to 300 psig. Test Pressure: 450 psig. Design Temperature: 500 F Nominal Part Number Overall Axial Spring Outside Size 5501R Length(1) Rate Diameter(2) Number of Weight NPS 5502R (inches) (lb./in.) (inches) Rods (lbs.) 1 1 /2-327 3.5 360 8.63 3 16 2-331 3.5 433 9.00 3 16 2 1 /2-335 3.5 1268 10.00 3 25 3-340 4.0 1491 10.75 3 28 4-348 4.5 1544 13.00 3 35 5-355 4.5 1871 14.00 3 42 6-360 5.0 2927 16.00 3 57 8-367 5.0 3687 19.00 3 79 10-374 6.0 3922 21.75 3 113 12-380 6.0 5520 25.50 3 179 14-381 8.0 6311 28.50 3 212 16-382 8.0 7831 31.00 4 293 18-383 9.0 8613 33.75 4 363 20-384 9.0 10,126 36.50 4 433 24-386 9.0 11,005 43.50 4 490 1 2 3 4 5 6 7 Note: (1) Overall length is measured from flange face to flange to flange face including the van stone for Type 5502R. (2) Maximum outside diameter includes limit rod lug attachments. (3) Type 5506R is available rated for full vacuum to 150 psig at 500 F as a replacement for rubber expansion joints, nominal sizes 2 through 14. Sizes 2 through 8 are 6.0 overall length and sizes 10 through 14 are 8 overall length. All other dimensions and performance data are the same as Type 5502R. Series 5500 5

Installation Procedure Application: Series 5500 Bellows Pump Connectors are designed for applications requiring isolation of mechanical equipment such as pumps that produce vibration or motion. The pump connector is design to connect directly to the equipment to reduce forces and moments on the equipment flanges. Refer to page 2 for a typical installation. Operating Conditions: Series 5500 pump connectors are supplied with a tag attached stating the Part Number and Design Pressure. Standard designs are 150 psig and 300 psig, and the test pressures are 225 psig and 450 psig respectively. The design temperature for all standard joints is 500 F. Be certain that the system conditions and test conditions do not exceed the design values. All 5500 pump connectors are designed for a full vacuum. Movement: Bellows pump connectors are designed to absorb vibration and should be installed in the neutral or manufactured position whenever possible. If necessary, they can be used for installation misalignment. Refer to Table 1 for the allowable displacements. Flow Direction and Orientation: The flow direction can be either direction for Series 5500 expansion joints that do not include flow liners, and they can be mounted in the horizontal or vertical plane. Flow liners are offered as an option be certain the flow is from the fixed end to the free end of the liner. The direction will be marked on the exterior. Limit Rods: All standard Series 5500 Bellows Pump Connectors include rods which are intended to prevent over-travel of the bellows. They are designed to react the full pressure thrust but they are intended to be installed loose to take full advantage of the movement capability of the bellows. Sizes 1-1 /2 through 14 have three rods 16 and over have four. One rod is removable if required for installation. This rod should be replaced and adjusted as illustrated. Shipping Restraints: External restraints are installed at the factory to insure installation at the correct length and alignment. For sizes 1-1 /2 through 6 wood spacers are installed between the flanges. Sizes 8 and over include steel bars that are painted yellow and labeled Shipping Bars, Remove after Installation. Leave the restraints installed until after the installation of the pump connector is complete - but they must be removed prior to pressure testing. CAUTION: Shipping Bars are not designed to react the pressure thrust they must be removed prior to testing. Shipping restraints that are installed by welding should be removed by cutting and grinding welds flush. Post Installation Inspection 1. Inspect the pump connector for damage. 2. Is the pump connector installed at the correct location? 3. Are the Shipping Restraints removed? 4. Is the pump connector free to move and is the anchor/equipment rigidly secured? 5. If the pump connector includes a flow liner, is the flow direction correct? 6 Copyright 2005 Hyspan Precision Products, Inc. Printed in the USA

Ordering Instructions Refer to Tables 2 and 3 to select the configuration and service conditions required for your application. Example 6 Bellows Pump Connector at 500 F maximum, 5502R-160 van stone 150 lb. flange both ends, limit rods 5502R-160 Size & pressure designation, 6 NPS, 150 psig Type specification, van stoned flange limit rods To add an optional flow liner, add an L to the type specification i.e. 5501RL or 5502RL LIMITED WARRANTY This warranty is given by Hyspan Precision Products, Inc. (Hyspan), located at 1685 Brandywine Avenue, Chula Vista, California 91911, (619) 421-1355, for the benefit of the first purchaser of the product to which the warranty applies. This warranty applies to those parts which are manufactured and delivered by Hyspan. The warranty is that the parts manufactured and delivered by Hyspan will be free from defects in material or workmanship under normal use and service for the time specified below. In the event of failure of a part due to such a covered defect, Hyspan will repair or replace, at its option, the defective part at its factory located at 1685 Brandywine Avenue, Chula Vista, California 91911. The part must be returned to the factory by and at the expense of the person claiming the benefit of the warranty. The warranty shall be for a period of twenty-four (24) months after the date of delivery of the product, twelve (12) months after commencement of use of the product, whichever period is the shortest. All products for which warranty claims are made must be returned as provided above to the factory within thirty (30) days from the date of claimed malfunction in order for this warranty to be effective. The only entity authorized to do any warranty repairs is the manufacturer. The repairs or replacement by Hyspan will be accomplished within forty-five (45) days from receipt of the defective parts at the factory. This warranty is expressed in lieu of all other warranties, expressed or implied, including the warranty of merchantability, the implied warranty of fitness for a particular purpose, and of all other obligations or liabilities on the part of Hyspan, and it neither assumes nor authorizes any other persons to assume for Hyspan any other liabilities in connection with the sale of the products. This warranty does not cover parts of products made by others or products or any part thereof which have been repaired or altered, except by Hyspan, or which shall have been subjected to misuse, negligence, or accident. Hyspan shall not be liable for damage or delay suffered by the purchaser regardless of whether such damages are general, special, or consequential in nature, whether caused by defective material or workmanship or otherwise, or whether caused by Hyspan s negligence regardless of the degree. Series 5500 7

Hyspan Precision Products, Inc. Tel: (619) 421-1355 1685 Brandywine Avenue Fax: (619) 421-1702 Chula Vista, CA 91911 www.hyspan.com