Cryoplunge 3 with GentleBlot for cryo-em

Similar documents
Phase Contrast Cryo Electron Tomography of Ice embedded Biological Specimens. 1. Introduction.

New Approaches to Specimen Preparation for Molecular TEM

TED PELLA, INC. Microscopy Products for Science and Industry

Monday: Y42 G53 Tuesday: Y42 G53 Wednesday: Y42 J11

Preparing 3D protein nano-crystals for electron diffraction studies

Supporting Online Material for

Introduction to Electron Microscopy Andres Kaech

Molecular Surveillance of Viral Processes Using Silicon Nitride Membranes

Electron Microscopy (EM) Grid

Highly Concentrated Aqueous Dispersions of Carbon Nanotubes for Flexible and Conductive Fibers

Real-time observation of protein aggregates in pharmaceutical formulations using liquid cell electron microscopy

Microscopy AND Microanalysis MICROSCOPY SOCIETY OF AMERICA 2008

Correlative Microscopy - From living cells to 3D electron microscopy A comprehensive workflow approach

Supporting Information

Supplemental Information. Site-Specific Cryo-focused Ion Beam Sample Preparation Guided by 3D. Correlative Microscopy

Workflow of Cryo-Electron Microscopy and Status of Domestic Infrastructure

MODEL NanoMill TEM Specimen Preparation System. Ultra-low-energy, inert-gas ion source. Concentrated ion beam with scanning capabilities

PP3010T Cryo preparation system for SEM, FE-SEM and FIB/SEM

Plunge-Freezing (Holey Carbon Method)

Electron Microscopy Sciences Industry Road. P.O. Box 550. Hatfield, PA Introduction. DuraSiNTM

EM Sample Preparation High Pressure Freezing. May 2013

Collection of continuous rotation MicroED Data from Ion Beam Milled Crystals of Any Size

Visualizing Cells Molecular Biology of the Cell - Chapter 9

MATERIALS. Sample Preparation & Grids for SEM & TEM... L 17 L 01. MATERIALS / Inorganics & thin films guide

ECE 541/ME 541 Microelectronic Fabrication Techniques

From Eye to Insight. Leica EM ACE. Coater Family

MiniTEM. Designed for nanoparticle characterization

Electronic supplementary information

Grids for Applications in High-Temperature High- Resolution Transmission Electron Microscopy

Grids for Applications in High-Temperature High- Resolution Transmission Electron Microscopy

Human Myoglobin ELISA Kit

3-DIMENSIONAL ELECTRON MICROSCOPY OF BIOLOGICAL SPECIMENS. Korrinn M. Strunk. BS, Carnegie Mellon University, 2009

BIOLOGICAL SAMPLE PREPARATION FOR TEM OBSERVATION. TEM Seminar Nov 16, 2017 Astari Dwiranti, Ph.D

MODEL 1051 TEM Mill ION MILLING. Ion milling is used on physical science. specimens to reduce thickness to electron

METHOD FOR IMPROVING FIB PREPARED TEM SAMPLES BY VERY LOW ENERGY Ar + ION MILL POLISHING

Human Beta 2-Microglobulin ELISA Kit

Supporting Information

Q150R Series Rotary Pumped Coaters

Simple method for formation of nanometer scale holes in membranes. E. O. Lawrence Berkeley National Laboratory, Berkeley, CA 94720

Immersion Freezing of Suspended Particles and Cells for Cryo-Electron Microscopy

Supplementary Information. for

Canine Transferrin ELISA KIT

JSM-7800F Field Emission Scanning Electron Microscope

Isolation of Protein

FUSION IN SITU HEATING AND ELECTRICAL. Protochips Quantifiably Better

Application Note. Sample Protection prior to FIB Processing. related instruments: Leica EM ACE600. Material Research. Life Science Research

Fibrinogen ELISA. For the quantitative determination of fibrinogen in biological fluids, serum, and plasma.

Pig Fibrinogen ELISA

SUPPORTING INFORMATION

For the quantitative determination of Complement Factor 3 in guinea pig serum and plasma

Light Sensitization of DNA Nanostructures via Incorporation of Photo-Cleavable Spacers

Transferrin ELISA. For the quantitative determination of transferrin in human biological samples

Differentially pumped quadrupole SIMS probe on FIBbased and two-beam microscopes

Lecture Day 2 Deposition

MODEL TEM Mill. Two independently adjustable TrueFocus ion sources

Model TEM Mill. Tabletop precision preparation for producing high-quality TEM specimens from a wide variety of materials EXCELLENCE MAGNIFIED

Dog Fibrinogen ELISA

Model Plasma Cleaner. Effectively cleans specimens for electron microscopy EXCELLENCE MAGNIFIED

The Evolution of Size, Shape, and Surface Morphology. of Gold Nanorods

Immuno-Labelling Cryosections

Using Monolithic Chromatographic Columns to Improve the Efficiency and Robustness of Biopharmaceutical Manufacturing

Transmission Electron Microscopy (TEM) Prof.Dr.Figen KAYA

Supplementary Information

IgY (Chicken) ELISA Kit

TF (Bovine) ELISA Kit

NANOMETER AND HIGH ASPECT RATIO PATTERNING BY ELECTRON BEAM LITHOGRAPHY USING A SIMPLE DUV NEGATIVE TONE RESIST

Monkey Albumin ELISA

Chicken IgY ELISA. Cat. No. KT-456 K-ASSAY. For the quantitative determination of IgY in chicken serum or plasma. For Research Use Only. 1 Rev.

Mouse Clusterin ELISA

Supplementary Figure 1 Two distinct conformational states of the HNH domain in crystal structures. a

Surface Micromachining

The principles and practice of electron microscopy

Supporting Information

Linear Broad Beam Ion Sources ACC-30x150 IS, ACC-40x300 IS and ACC-40 x 600 IS

Supporting Information. Octopods vs. Concave Nanocrystals: Control of Morphology by Manipulating the. Kinetics of Seeded Growth via Co-reduction

HUMAN IgG. Immunoperoxidase Assay for Determination of IgG in Human Samples

Sheep IgG ELISA Kit. Innovative Research, Inc. Catalog No: ISHIGGKT. Lot No: SAMPLE

RAT KIM-1 ELISA. For the quantitative determination of Kidney Injury Molecule-1 in rat serum, plasma, and urine.

1 The role of scanning electron microscopy in cell and molecular biology: SEM basics, past accomplishments, and new frontiers

Roman Chistyakov and Bassam Abraham Zond Inc/Zpulser LLC, Mansfield, MA

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

Cleaning samples. Options available. » Do not use organic. » Never, never, use squeeze. » Use detergents instead e.g. » Carbon Dioxide snow

Advanced SEM: ESEM and Cryo-SEM

Scanning Electron Microscope & Surface Analysis. Wageningen EM Centre Marcel Giesbers

E! 6143 MiniTEM Development of benchtop equipment for automated characterization of viruses and other biological nanoparticles

Specimen configuration

Journal of Structural Biology

Mouse Fibrinogen ELISA

Bending Gold Nanorods with Light

SunMaxxTM Information Guide: Evacuated Tube Solar Collectors

MODEL 1061 SEM Mill ION MILLING. Ion milling is used in the physical. sciences to enhance the sample s surface. characteristics. Inert gas, typically

CANINE HAPTOGLOBIN ELISA KIT

Vitrification after multiple rounds of sample application and blotting improves particle density on cryo-electron microscopy grids.

Sodium dodecyl sulphate polyacrylamide gel electrophoresis (SDS-PAGE)

Probing Battery Chemistry with Liquid Cell Electron Energy Loss Spectroscopy

Heteroepitaxy of Monolayer MoS 2 and WS 2

MODEL Plasma Cleaner. Simultaneously cleans specimen and specimen holder. Cleans highly contaminated specimens in 2 minutes or less

HUMAN APOLIPOPROTEIN H (APO-H) ELISA Assay Kit

A STUDY OF THE EFFECTIVENESS OF THE REMOVAL OF HYDROCARBON CONTAMINATION BY OXIDATIVE CLEANING INSIDE THE SEM.

Biomimetic synthesis of gold nanocrystals using a reducing amphiphile. Ferdinand Gonzaga, Sherdeep Singh and Michael A. Brook. Department of Chemistry

Transcription:

Cryoplunge 3 with GentleBlot for cryo-em

Cryoplunge 3 with GentleBlot system GentleBlot technology provides very gentle 1- and 2-side blotting for preparing frozen hydrated specimens for cryo-em Ethane temperature controller maintains temperature of the ethane just above its melting point Quick disconnect tweezers facilitate handling the frozen hydrated grid Protected environment for transferring the frozen hydrated grid within the cryo workstation Easy-to-use Versatile design Consistent, high quality results

Cryoplunge 3 with GentleBlot system

Cryoplunge 3 with GentleBlot system GentleBlot technology has two components Specialized blot assemblies to manually adjust the pressure applied to the specimen grid during the blotting process Factory preset pneumatic force that provides optimal speed for the blotters to contact the specimen grid

Cryoplunge 3 with GentleBlot system The solution for blotting fragile specimen substrates Cryo-SiN (silicon nitride TEM windows) Continuous carbon foils Large mesh grids/substrates used for tomographic data collection C-flat or Quantifoil holey carbon films Any fenestrated grid with a very thin (~5 nm) carbon coat overlay EM affinity grids (affinity capture technology)

Affinity capture technology Affinity capture technology is an innovative platform that features EM affinity grids and affinity capture devices Affinity biofilm (lipid monolayer that is less than ~15 Å) coats the surface of the entire fenestrated carbon film and does not impair imaging Specialized molecular tools are designed to specifically isolate macromolecular assemblies or specific cells of interest Allows rapid purification of biological machinery for TEM imaging within minutes Provides superior partitioning of the specimen

GentleBlot Solution for blotting fragile substrates Cryo-SiN Affinity capture Cryoplunge 3 with GentleBlot C-flat holey carbon grid Cryo-SiN (silicon nitride microchip) Vitrified inactive rotavirus DLPs on Affinity Capture Substrate. Scale bar is 100 nm. Images courtesy of Dr. Debbie Kelly, VTCRI, Roanoke, VA. USA. Tanner, J. R.; Demmert, A. C.; Dukes, M. J.; Melanson, L. A.; McDonald, S. M.; et al. Cryo-SiN An alternative substrate to visualize active viral assemblies. J Analyt Molecul Tech 2013;1(1): 6.

Solarus 950 system for uniformly hydrophilic substrates Plasma cleaning of the EM substrate is a key step in the preparation process when a uniformly hydrophilic surface is required Solarus 950 system is designed to ionize a hydrogen/oxygen gas mixture (in addition to the standard argon or argon/oxygen mixtures) 50% cooler than cleaning with traditional Ar/O 2 (75%:25%) mixture Gentle cleaning with less sputter damage Uniformly hydrophilic charge Viewing port Specimen holder ports Specimen chamber Touch screen Solarus 950 advanced plasma cleaning system

Cryo-EM Preparing the frozen hydrated specimen Optimize the support substrate surface Hydrophilic, hydrophobic, Affinity Capture Apply a small aliquot of specimen to surface of substrate 2-5 µl depending on the concentration of the specimen Affinity Capture optimizes partitioning of the specimen within the holes of the fenestrated support at low concentration (0.01 mg/ml) and low volume (2 µl) Apply the specimen

Cryo-EM Preparing the frozen hydrated specimen Blot with filter paper until only a thin fluid layer (~100 nm) is left on the support substrate

Cryo-EM Preparing the frozen hydrated specimen Plunge the thin fluid layer into a suitable cryogen of high heat capacity (liquid ethane), which results in instantaneous freezing of the specimen in a layer of non-crystalline (vitreous) ice Plunge freeze the specimen grid into liquid ethane

Cryo-EM Preparing the frozen hydrated specimen Cryo-transfer the frozen hydrated grid for high-resolution data collection in the TEM Transfer frozen hydrated grid from the workstation of Cryoplunge 3 system Load the frozen hydrated specimen grid into the cryo-transfer holder

Results

140x Map of frozen hydrated grid 2-side blot Image courtesy of Dr. Chen Xu, Rosenstiel Basic Medical Sciences Research Center, Brandeis University, Waltham, MA, USA.

Cryoplunge 3 and Solarus 950 systems 1 2 3 The three images above are an example of the high quality frozen hydrated preparations produced with Cryoplunge 3 system. (1) Image of a single grid square; TEM magnification ~900x, electron dose 0.01 e - /Å 2. (2) Higher magnification image of a portion of the grid square; 4700x, 0.1 e - /Å 2. (3) Image of part of one hole; 59kx, 20 e - /Å 2. The frozen-hydrated microtubule specimen was prepared on Quantifoil R1.2/1.3 macro machined holey carbon grids which were plasma cleaned using the Solarus 950 advanced plasma cleaning system for 15 s at 50 W using hydrogen and oxygen plasma. All images were recorded on an FEI Tecnai F30 TEM with a 626 70 Single tilt liquid nitrogen cryo-transfer holder and an UltraScan 4000 camera. Images courtesy of Dr. Chen Xu, Rosenstiel Basic Medical Sciences Research Center, Brandeis University, Waltham, MA, USA.

Cryoplunge 3 with GentleBlot technology Image of frozen-hydrated rotavirus double-layered particles (0.01 mg/ml concentration, 2 µl volume) prepared on affinity grids decorated with His-tagged protein A and antibodies against the outer capsid protein, VP6. Specimen was prepared using Cryoplunge 3 with GentleBlot system on Quantifoil 2/1 support film. Specimens were examined under low dose conditions at 120 kv. The image was recorded at 6000x using a dose of ~5 e - /Å 2. Superior partitioning of the specimen as they attached to the affinity capture biofilm in the holes on the support film Image courtesy of Dr. Debbie Kelly, Virginia Tech Carilion Research Institute, Roanoke, VA, USA.

Cryoplunge 3 with GentleBlot technology Image of frozen-hydrated rotavirus double-layered particles (0.01 mg/ml) prepared on affinity grids decorated with His-tagged protein A and antibodies against the outer capsid protein, VP6. Specimen was prepared using Cryoplunge 3 with GentleBlot system on C-flat 2/1 grids, Protochips, Inc. Specimens were examined under low dose conditions at 120 kv. Image was recorded at 50,000x using a dose of ~5 e-/å 2. Image courtesy of Dr. Debbie Kelly, Virginia Tech Carilion Research Institute, Roanoke, VA, USA.

Cryoplunge 3 and Solarus 950 systems Frozen hydrated tobacco mosaic (TMV) sample prepared using Cryoplunge 3 system. Image was recorded at TEM magnification of 59kx at 300 kev and an electron dose of 20 e - /Å 2 using a model 626 Liquid nitrogen cryo-transfer holder and UltraScan 4000 camera. Sample was prepared on Quantifoil 1.2/1 specimen support, using Solarus 950 advanced plasma cleaning system prior to freezing. Image courtesy of Dr. Chen Xu Rosenstiel Basic Medical Sciences Research Center, Brandeis University, Waltham, MA, USA.

Cryoplunge 3 and Solarus 950 systems Frozen hydrated microtubule sample prepared using Cryoplunge 3 system. Image was recorded at 300 kev using a model 626 Liquid nitrogen cryo-transfer holder and UltraScan 4000 camera. Sample was prepared on Quantifoil 1.2/1 specimen support, using Solarus 950 advanced plasma cleaning system prior to freezing. Image courtesy of Dr. Chen Xu, Rosenstiel Basic Medical Sciences Research Center, Brandeis University, Waltham, MA, USA.

Cryoplunge 3 and Solarus 950 systems Frozen hydrated lipid vesicles prepared using Cryoplunge 3 system. Image was recorded at TEM magnification of 25kx at 200 kev and electron dose of ~20 e - /Å 2 using model 910 Multi-specimen single tilt cryo transfer holder and UltraScan 4000 camera. Sample was prepared on Quantifoil specimen support, using Solarus 950 advanced plasma cleaner prior to freezing. Image courtesy of Jessica Goodwin and Htet Khant, National Center for Macromolecular Imaging, Baylor College of Medicine, Houston, TX, USA.

Cryoplunge 3 and Solarus 950 systems Frozen hydrated influenza virus prepared using Cryoplunge 3 system. Gold particles were added as fiducial markers for cryoelectron tomography. Zero loss image was recorded at TEM magnification of 50kx and electron dose of ~20 e - /Å 2 at 300 kev using UltraScan 4000 camera. Sample was prepared on Quantifoil (2/2) specimen support, using Solarus 950 advanced plasma cleaning system prior to freezing. Image courtesy of Dr. Ruben Diaz-Avalos, New York Structural Biology Center, NY, USA.

Cryoplunge 3 and Solarus 950 Systems Frozen-hydrated image of the Ndc80 complex decorated microtubules: magnification 30kx, electron dose 40 e - /Å 2. Specimens were prepared on CFlat Protochips, Inc. CF-2/1-4C-50 holey carbon grids which were plasma cleaned using the Solarus 950 advanced plasma cleaning. Frozen hydrated preparations produced using Cryoplunge 3 system. Image recorded at 100 kv on a TEM equipped with a model 626 70 Single tilt liquid nitrogen cryotransfer holder. Image courtesy of Dr. Elizabeth Wilson-Kubalek, Cell Biology, The Scripps Research Institute, La Jolla, CA, USA.