REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

Similar documents
REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

ICC-ES Evaluation Report Reissued October 1, 2010 This report is subject to re-examination in two years.

REPORT HOLDER: GEORGIA PACIFIC GYPSUM LLC 2861 MILLER ROAD DECATUR, GEORGIA EVALUATION SUBJECT: DENSELEMENT BARRIER SYSTEM

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT: MASTERSEAL AWB 660 I VAPOR RETARDER, AIR AND WATER-RESISTIVE BARRIER AND FLEXIBLE FLASHING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLEXIBLE FLASHINGS REPORT HOLDER: HUBER ENGINEERED WOODS, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING REPORT HOLDER: SILCA SYSTEM

REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC. EVALUATION SUBJECT: GRABBER FASTENERS FOR USG STRUCTURAL PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES REPORT HOLDER: TEFUTE BUILDING MATERIALS COMPANY, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: EQUITONE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: ENVIRONMENTALLY SAFE PRODUCTS, INC.

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BARTILE ROOFS, INC. EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: METALS SECTION: COLD FORMED METAL FRAMING REPORT HOLDER: AEGIS METAL FRAMING, A DIVISION OF MITEK

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

ESR-1785* Reissued December 1, 2012 This report is subject to renewal December 1, 2014.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: TEJAS BORJA USA EVALUATION SUBJECT:

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FASTENINGS DIVISION: FINISHES SECTION: FASTENERS REPORT HOLDER: HILTI, INC.

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD FLAPS, LLC EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHEATHING REPORT HOLDER: HUBER ENGINEERED WOODS, LLC

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD FLAPS, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-FABRICATED WOOD TRUSSES REPORT HOLDER: EAGLE METAL PRODUCTS

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: GRABBER NAILS FOR GYPSUM WALLBOARD INSTALLATION

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS 9050 CENTRE POINTE DRIVE, SUITE 400 WEST CHESTER, OHIO EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: APPLIED FIREPROOFING REPORT HOLDER: FLAMEOFF COATINGS, INC. EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: HB&G BUILDING PRODUCTS, INC.

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: KINGSPAN LIGHT + AIR LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: CPG INTERNATIONAL LLC DBA THE AZEK COMPANY LLC EVALUATION SUBJECT:

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: SKYCO SKYLIGHTS 2995 AIRWAY AVENUE, SUITE B COSTA MESA, CALIFORNIA 92626

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: BORAL COMPOSITES, INC.

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: ULTRALOX 2955 LONE OAK DRIVE, SUITE 180 EAGAN, MINNESOTA 55121

Trusted ICC ES HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

Trusted ICC ES DIVISION: 07 SECTION: 07 (VFS) Evaluation. report, or as to any. ICC-ES Evaluation

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHEATHING REPORT HOLDER: HUBER ENGINEERED WOODS, LLC EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: ULTRALOX EVALUATION SUBJECT:

Joint Evaluation Report

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: DERBY BUILDING PRODUCTS INCORPORATED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THERMOSEAL LLC EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

Joint Evaluation Report ICC-ES (800) (562)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

Joint Evaluation Report

Joint Evaluation Report

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

Joint Evaluation Report

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

DIVISION: METALS SECTION: COLD FORMED METAL FRAMING REPORT HOLDER: AEGIS METAL FRAMING, A DIVISION OF MITEK

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ELASTOCHEM SPECIALTY CHEMICALS, INC.

ICC-ES Evaluation Report. ESR-3102 Reissued July 1, 2013 This report is subject to renewal August 1, 2015.

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.

Transcription:

0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1474 Reissued 10/2016 This report is subject to renewal 10/2018. DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION: 06 16 00 SHEATHING DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 25 00 WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: 07 27 00 AIR BARRIERS REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 EVALUATION SUBJECT: ZIP SYSTEM WALL SHEATHING Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1474 Reissued October 2016 Revised November 2017 This report is subject to renewal October 2018. A Subsidiary of the International Code Council DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 16 00 Sheathing DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 25 00 Water-resistive Barriers/Weather Barriers Section: 07 27 00 Air Barriers REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 (800) 933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM WALL SHEATHING 1.0 EVALUATION SCOPE Compliance with the following codes: 2015, 2012 and 2009 International Building Code (IBC) 2015, 2012 and 2009 International Residential Code (IRC) 2015, 2012 and 2009 International Energy Conservation Code (IECC) For evaluation of compliance with codes adopted by the Los Angeles Department of Building and Safety (LADBS), see ESR-1474 LABC and LARC Supplement. Properties evaluated: Weather resistance Air leakage 2.0 USES ZIP System Wall Sheathing panels are used as combination wall sheathing, air barrier, and water-resistive barrier. This report recognizes the use of ZIP System Sheathing, when installed with ZIP System flexible flashing seam tape, in walls of Type V construction (IBC) and dwellings under the IRC, and as an alternate to the water-resistive barrier required in Chapter 14 of the IBC and Chapter 7 of the IRC, and to the air barrier required by Sections R402.4 and C402.5.1 of the 2015 IECC (Sections R402.4 and C402.4.1 of the 2012 IECC; Sections 402.4.1 and 502.4.3 of the 2009 IECC). 3.0 DESCRIPTION 3.1 Sheathing Panel: The ZIP System Wall Sheathing panel is an OSB wood structural panel having a laminated exterior facer. The Exposure 1 OSB complies with US DOC PS 2 for wood structural panels. The exterior facer is a medium-density, phenolic-impregnated, polymer-modified sheet material qualifying as a Grade D water-resistive barrier (required by Section 2510.6 of the 2015, 2012 and 2009 IBC). The panels are nominally 4 feet wide by 8, 9, 10, 11 or 12 feet long and have a square-finished-edge or machined-edge profile. When tested in accordance with ASTM E96 (water method), the polymer-modified sheet overlay has a minimum vapor permeance of 12 perms [68.6 X 10-11 kg/(pa-s-m 2 )]. Equivalent Water Vapor Transmission rate (WVT) of the polymer-modified sheet overlay is 83.4 g/(24h-m 2 ) when tested at 73.4 F (23 C). The water-resistive barrier and air barrier properties of the ZIP System Wall Sheathing Panels are not affected when the panels are manufactured to comply as facing materials for SIPs in accordance with Section R610.3.2 and Table R610.3.2 of the 2015 IRC (Section R613.3.2 and Table R613.3.2 of the 2012 and 2009 IRC). 3.2 Seam Tape: The ZIP System seam tape is a self-adhering membrane tape consisting of acrylic adhesive laminated to a polyolefin backing. The tape is 0.012 inch (0.30 mm) thick with a minimum width of 3 3 / 4 inches (95.2 mm), and comes in rolls of various lengths. 4.0 INSTALLATION 4.1 General: Installation of ZIP System Wall Sheathing panels must comply with the applicable code, this report and the manufacturer s published installation instructions. The manufacturer s published installation instructions must be available at the jobsite during installation. 4.2 Application: 4.2.1 General: The ZIP System Wall Sheathing panels must be attached to wall framing in accordance with the applicable code for wood structural panels, and in ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 9

ESR-1474 Most Widely Accepted and Trusted Page 2 of 9 compliance with their panel span rating. The panels must be installed with the polymer-modified sheet overlay facing the exterior. In accordance with the manufacturer's published installation instructions, it is recommended that the square edges of the panels be installed with a gap between adjacent panels and between panels and dissimilar materials. All ZIP System Wall Sheathing panel seams must be sufficiently sealed with ZIP System seam tape. All overlay surfaces must be dry and free of sawdust and dirt prior to application of the ZIP System seam tape. The ZIP System seam tape must extend a minimum of 1 inch (25.4 mm) past the panel edge T-joint intersections and must be centered within 1 / 2 inch (12.7 mm) over the middle of panel seams. The tape must be pressed firmly to adhere to the surfaces and seal the seams. Wrinkles in the ZIP System seam tape are acceptable unless they create a leak path to the panel seam. 4.2.2 Flashing: Flashing complying with the applicable code must be installed at the perimeter of door and window assemblies, penetrations and terminations of exterior wall assemblies, exterior wall intersections with roofs, chimneys, porches, decks, balconies, and similar projections, and at built-in gutters and similar locations where moisture could enter the wall. An adhesive-backed flashing tape recognized in a current ICC-ES evaluation report must be installed to seal all ZIP System Wall Sheathing flashing joints. Penetration items must be sealed to the panels. The adhesive-backed flashing tape must comply with the ICC-ES Acceptance Criteria for Flexible Flashing Materials (AC148) and must be installed in accordance with the manufacturer s published installation instructions. See Figures 1 through 7 of this report for typical flashing, water-resistive barrier and air barrier assembly installation details. 4.2.3 Air Barrier Assembly: ZIP System Wall Sheathing fastened to maximum 24-inch-on-center (610 mm) wood wall framing, using minimum 6d nails spaced at 6 inches (152 mm) around panel edges and at 12 inches (305 mm) in the field, leaving a 1 / 8 -inch (3.18 mm) gap between panels, forms an air barrier assembly when the gaps between panels and the perimeter of penetrations are sealed with ZIP System seam tape as required by Section 4.2.1. The assembly has demonstrated a maximum air leakage of 0.0072 cfm/ft 2 [0.037 L/(s m 2 )] infiltration and 0.0023 cfm/ft 2 [0.012 L/(s m 2 )] exfiltration at a pressure differential of 1.57 psf (75 Pa) when tested in accordance with ASTM E2357. 5.0 CONDITIONS OF USE The ZIP System Wall Sheathing panel and tape system described in this report complies with, or is a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 This evaluation report and the manufacturer s published installation instructions, when required by the code official, must be submitted at the time of permit application. 5.2 The ZIP System Wall Sheathing panels must be manufactured, identified and installed in accordance with this report and the manufacturer s published installation instructions. In the event of a conflict between the instructions and this report, this report must govern. 5.3 The ZIP System Wall Sheathing panels must be covered with a code-complying exterior wall covering, or one that is recognized in a current ICC-ES evaluation report. 5.4 The OSB sheathing must comply with US DOC PS-2. 5.5 Fire-resistance-rated construction is outside the scope of this report. 5.6 The Zip System Wall Sheathing panels are manufactured by Huber Engineered Woods, LLC, in Crystal Hill, Virginia; Easton, Maine; Commerce, Georgia; Broken Bow, Oklahoma; and Shawinigan, Quebec Canada, under a quality-control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Water-resistive Membranes Factorybonded to Wood-based Structural Sheathing, Used as Water-resistive Barriers (AC310), dated May 2008 (editorially revised August 2015). 6.2 Air leakage data in accordance with ASTM E2357. 7.0 IDENTIFICATION Each ZIP System Wall Sheathing panel described in this report must bear a label that includes the manufacturer s name (Huber Engineered Woods LLC), the product name, nominal panel thickness, the evaluation report number (ESR-1474), and the words Mill 229, Crystal Hill, Virginia ; Mill 228, Easton, Maine ; Mill 227, Commerce, Georgia ; Mill 290, Broken Bow, Oklahoma, or Mill 390, Shawinigan, Quebec Canada. The OSB sheathing must also bear a label demonstrating compliance with US DOC PS 2 from an approved inspection agency. The ZIP System seam tape roll must be labeled with the ZIP System logo and the evaluation report number ESR-1474 (see Figure 8).

ESR-1474 Most Widely Accepted and Trusted Page 3 of 9 SILL SECTION HEADER SECTION JAMB SECTION FIGURE 1 TYPICAL CROSS SECTIONS OF FLANGED WINDOW

ESR-1474 Most Widely Accepted and Trusted Page 4 of 9 SILL SECTION HEADER SECTION JAMB SECTION FIGURE 2 TYPICAL CROSS SECTIONS OF INSTALLED BRICK MOLD WINDOW

ESR-1474 Most Widely Accepted and Trusted Page 5 of 9 FIGURE 3 ROOF-WALL INTERSECTION (OPTION 1) FIGURE 4 ROOF-WALL INTERSECTION (OPTION 2) FIGURE 5 TYPICAL WALL-SILL INTERSECTION AND FLASHING DETAILS FOR BRICK SIDING FIGURE 6 TYPICAL WALL-SILL INTERSECTION AND FLASHING DETAILS FOR LAPPED SIDING

ESR-1474 Most Widely Accepted and Trusted Page 6 of 9 FIGURE 7 INSTALLATION AT PENETRATION OPENING (NON-FIRE-RESISTANCE RATED) FIGURE 8 LABELING FOR THE ZIP SYSTEM SEAM TAPE ROLL

ICC-ES Evaluation Report ESR-1474 LABC and LARC Supplement Issued November 2017 This report is subject to renewal October 2018. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 16 00 Sheathing DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 25 00 Water-resistive Barriers/Weather Barriers Section: 07 27 00 Air Barriers REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 (800) 933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM WALL SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the ZIP System Wall Sheathing, described in ICC-ES master evaluation report ESR-1474, has also been evaluated for compliance with the codes noted below as adopted by the Los Angeles Department of Building and Safety (LADBS). Applicable code editions: 2017 City of Los Angeles Building Code (LABC) 2017 City of Los Angeles Residential Code (LARC) 2.0 CONCLUSIONS The ZIP System Wall Sheathing, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474, complies with the LABC Chapter 14, and the LARC Section R703, and is subject to the conditions of use described in this supplement. 3.0 CONDITIONS OF USE The ZIP System Wall Sheathing, described in this evaluation report must comply with all of the following conditions: All applicable sections in the master evaluation report ESR-1474. The design, installation, conditions of use and identification are in accordance with the 2015 International Building Code (2015 IBC) provisions noted in the master evaluation report ESR-1474. The design, installation and inspection are in accordance with additional requirements of LABC Chapters 16 and 17, as applicable. This supplement expires concurrently with the master report, reissued October 2016 and revised November 2017. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 7 of 9

ICC-ES Evaluation Report ESR-1474 CBC AND CRC Supplement Issued November 2017 This report is subject to renewal October 2018. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 16 00 Sheathing DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 25 00 Water-resistive Barriers/Weather Barriers Section: 07 27 00 Air Barriers REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 (800) 933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM WALL SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that ZIP System Wall Sheathing, recognized in ICC-ES master evaluation report ESR-1474, has also been evaluated for compliance with the codes noted below. Applicable code editions: 2016 California Building Code (CBC) 2016 California Residential Code (CRC) 2.0 CONCLUSIONS 2.1 CBC The ZIP System Wall Sheathing, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474, complies with CBC Chapter 14, provided the design and installation are in accordance with the 2015 International Building Code (2015 IBC) provisions noted in the master report and the additional requirements of the CBC Chapters 14, 16, 16A, 17, 17A and 23, as applicable. 2.2 CRC The ZIP System Wall Sheathing, as described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474, complies with the CRC, provided the design and installation are in accordance with the 2015 International Residential Code (2015 IRC) provisions noted in the master report. The ZIP System Wall Sheathing recognized in this supplement has not been evaluated for compliance with the International Wildland-Urban Interface Code. This supplement expires concurrently with the master report, reissued October 2016 and revised November 2017. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 8 of 9

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1474 FBC Supplement Reissued October 2016 Revised November 2017 This report is subject to renewal October 2018. A Subsidiary of the International Code Council DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 16 00 Sheathing DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 25 00 Water-Resistive Barriers/Weather Barriers Section: 07 27 00 Air Barriers REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 (800) 933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM WALL SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that ZIP System Wall Sheathing panels, recognized in ICC-ES master evaluation report ESR-1474, have also been evaluated for compliance with the codes noted below. Applicable code editions: 2017 Florida Building Code Building 2017 Florida Building Code Residential 2.0 CONCLUSIONS The ZIP System Wall Sheathing panels, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474, comply with the Florida Building Code Building and the Florida Building Code Residential, provided the design and installation are in accordance with the 2015 International Building Code provisions noted in the master report. Use of the ZIP System Wall Sheathing panels for compliance with the High-Velocity Hurricane Zone provisions of the Florida Building Code Building and the Florida Building Code Residential has not been evaluated, and is outside the scope of this evaluation report. For products falling under Florida Rule 9N-3, verification that the report holder s quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued October 2016 and revised November 2017. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 9 of 9