Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description

Similar documents
Roofing. Polymeric sheet for roof waterproofing. Product Description. Tests. Product Data Sheet Edition _1

Construction. Sarnafil TS 77-18E Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil TS 77-20E Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil G Felt. Polymeric membrane for roof waterproofing. Product Description

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

PRODUCT DATA SHEET Sarnafil TS 77-18

PRODUCT DATA SHEET Sarnafil TS 77-20

PRODUCT DATA SHEET Sarnafil TS 77-15

Construction. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Roofing. Sarnafil G EL Felt. Polymeric membrane for roof waterproofing. Product Description

PRODUCT DATA SHEET Sarnafil TS 77-20

Construction. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Construction. Polymeric membrane for roof waterproofing. Product Description. Tests

Polymeric membrane for roof waterproofing

PRODUCT DATA SHEET Sarnafil G EL

PRODUCT DATA SHEET Sarnafil G EL

Roofing. Sika-Trocal SG 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

PRODUCT DATA SHEET Sarnafil TG Felt

Construction. Sika-Trocal SGmA 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

Sarnavap 1000E is an unsupported vapour control layer based on PE-LD (Low Density Polyethylen).

Construction. SikaProof A. Fully bonded FPO sheet waterproofing membrane system for basement and other below ground structures. Product Description

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

Roofing. Sarnavap 500E. Vapour control layer. Product Description. Tests. Product Data. Form. Storage

PRODUCT DATA SHEET SikaProof A

Sarnavap 5000E SA Vapour Control Layer

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description.

SikaProof A. Fully bonded FPO sheet membrane waterproofing system for basements and other below ground structures. Product Description

PRODUCT DATA SHEET. SikaProof A

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

Sikatherm PIR GT. PIR Thermal Insulation Board. Product Description. Product Data

Roofing and waterproofing synthetic membrane

Part of the Sikaplan WT Membrane System

Roofing and waterproofing synthetic membrane

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description

INOFIN FPO roofing membrane

Roofing. Sarnacol Adhesive for Insulation Boards. Product Description. Product Data. Polyurethane-based humidity-hardening one-pack adhesive

Construction. Tricosal Waterstops - Tricomer. Waterstops for joint sealing in watertight concrete construction according to DIN and DIN

According German Standard DIN part 1. Standard range of PVC-P based flexible waterstops for movement (expansion) and construction joint sealing

Waterproofing membrane FATRAFOL 810

Construction. Adhesive for Sarnafil G Felt roof waterproofing membranes. Product Description. Tests. Product Data. Form

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description

Firestone UltraPly TPO The light colored roofing choice

Installation Instructions ALUTRIX 600 ALUTRIX FR

METHOD STATEMENT Sika Drain-850 Geo

European Technical Assessment. ETA 12/0153 of 01/06/2018. General Part. Technical Assessment Body issuing the ETA: FM Approvals Limited

Sika Tricomer Compression Seals

Part of the Sikaplan WT Membrane System

Agrément Certificate 08/4532 website: Product Sheet 1

NBI Technical Approval

Sika Elastomer Compression Seals

Sika-Trocal C200 Adhesive. Sika-Trocal C200 is an adhesive to bond certain insulation boards on approved substrates.

PRODUCT INFORMATION. 1/ Version #4

SIKAPROOF A WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 852 [2014] Appraisal No. 852 (2014) Amended 24 April 2018

SARNAWELD - INDUCTION WELDING FASTENING

PRODUCT DATA SHEET Sikalastic -501 Roofseal Plus

MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE

Sika KAB combination joint waterbars waterstopping systems

SECTION TPO WATERPROOFING MEMBRANE FOR FLAT ROOFS INSTALATION

ELASTOFLEX SA P ELASTOFLEX SA P mineral

REOXTHENE TECHNOLOGY FLEXO-LIGHT SBS PROFESSIONAL LINE RANGE OF PRODUCTS FORMULATED AND DEVELOPED EXPRESSLY FOR ROOFING PROFESSIONALS -20 C

REOXTHENE TECHNOLOGY BITULIGHT LINE -5 C WATERPROOFING MEMBRANE WITH REVOLUTIONARY TECHNOLOGY

SINTEF Building and Infrastructure confirms that. Protan G, GG og GT roofing and waterproofing membranes

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES

Sika Hydrotite CJ K

PRODUCT DATA SHEET SARNAFIL S 327 ENERGYSMART ROOF MEMBRANE FELTBACK

SECTION THERMOPLASTIC MEMBRANE ROOFING. C. Flashings. D. Roofing cant strips, stack boots, roofing expansion joints, and walkway pads.

Construction. Adhesive for bonding reinforcement. Product Description. Tests. Product Data Sheet Edition 16 December 2014

SealArm Tape TPE. Building & Joint Sealants T E C H N I C A L D A T A S H E E T. Uses. Features and Benefits

SUREPLAN FPO MEMBRANES SUREPLAN FPO MECHANICALLY FASTENED ROOF WATERPROOFING MEMBRANES

WaterproofingSystems. Roof Waterproofing with Thermoplastic Polyolefin Membranes

Installation Guide Roofing. Sarnafil Membranes

J41 Reinforced bitumen membrane roof coverings

PRODUCT DATA SHEET Sikalastic Rapid-721

Construction. 2-part epoxy impregnation resin. Product Description. Product Data. Tests. Form. Product Data Sheet Edition 4 March 2015

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Conforms to the requirements of ETAG Certificate: European Technical Approval No. ETA-05/0265

REOXTHENE TECHNOLOGY EASY LIFT PROFESSIONAL LINE -10 C WATERPROOFING MEMBRANE WITH REVOLUTIONARY TECHNOLOGY WALL-FLOOR JUNCTION MEMBRANE

1-part elastic joint sealant and multipurpose adhesive

VINITEX INSTALLATION PROCEDURES

SUSTAINABLE ROOFS FOR THE FUTURE

Construction. High performance joint sealing system. Product Description 1 1/9. Product Data Sheet Edition 29th October 2015

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

WOLFIN SINGLE-PLY ROOF WATERPROOFING SYSTEMS COSMOFIN FM SINGLE-PLY PVC ROOF WATERPROOFING MEMBRANES

SARNAFIL WATERPROOFING MEMBRANES SARNAFIL ADHERED ROOF WATERPROOFING MEMBRANES

University of New Hampshire Scholars' Repository

1-part elastic joint sealant and multipurpose adhesive

1-part elastic joint sealant and multipurpose adhesive

The Freudenberg Politex Group

BAUDER SINGLE PLY PVC ROOF WATERPROOFING MEMBRANES THERMOFOL U

Installation Specification. Preface

COSMOFIN FG Welding Guidelines

Monarfin Durable TPO waterproofing systems

Agrément Certificate 17/5466 website: Product Sheet 1 LEADAX FLASHINGS LEADAX

Firestone Polyiso Boards

1-part polyurethane pourable self levelling floor joint sealant

Sealing profiles which swell in contact with water.

PRODUCT DATA SHEET SikaProof Bentonite

Sika Waterbars - Tricomer Clamped Type

Construction. High performance joint sealing system. Product Description. System Data Sheet Edition _1. 1 Sikadur Combiflex SG system 1/8

Sikadur -330 is a two part, thixotropic epoxy based impregnating resin / adhesive.

Transcription:

January, 2009 Sarnafil TS 77-15 Polymeric membrane for roof waterproofing Construction Product Description Uses Characteristics / Advantages Approval / Standards Sarnafil TS 77-15 (thickness 1.5 mm) is a Polyester reinforced, multi-layer, synthetic roof waterproofing sheet based on premium-quality flexible polyolefins (FPO) containing ultraviolet light stabilizers, flame retardant and an inlay of glass non-woven according to EN 13956. Sarnafil TS 77-15 is a hot air weldable roof membrane formulated for direct exposure and designed to use in all global climatic conditions. Sarnafil TS 77-15 is produced with an inlay of glass non-woven for dimensional stability and a polyester reinforcement for high strength. Sarnafil TS 77-15 is provided for mechanically attached roof systems. Sarnafil TS 77-15 has no built-in stress at the time of production and has a fully encapsulated carrier with no risk to delamination or water-wicking. The dimensional stability of Sarnafil TS 77-15 is excellent. Waterproofing membrane for: Mechanically fastened roofs Outstanding resistance to weathering, including permanent UV irradiation Excellent flexibility in cold temperatures No built-in stress at the time of production High dimensional stability High resistance against impact load Excellent weldability No risk of delamination or water-wicking Compatible to old bitumen Recyclable Sarnafil TS 77-15 is designed and manufactured to meet the most international recognised standards. Polymeric sheets for roof waterproofing according to EN 13956, certified by notified body 1213-CPD-3915 and provided with the CE-mark. Reaction to fire according to EN 13501-1, class E. External fire performance tested according to ENV 1187 and classified according to EN 13501-5: B ROOF (t1). Official Quality Approvals and Agrement Certificates and approvals. Monitoring and assessment by approved laboratories. Quality Management system in accordance with EN ISO 9001/14001. Sarnafil TS 77-15 1/6

Appearance / Colours Surface: matt Colours: Top surface: beige grey (nearest RAL 7040) Bottom surface: black Packaging Storage Conditions / Shelf-Life Sarnafil TS 77-15 standard rolls are wrapped individually in a blue PE-foil. Packing unit: up to 27 rolls per pallet Roll length: 20.00 m Roll width: 2.00 m Roll weight: 66.00 kg Rolls must be stored in a horizontal position on pallet and protected from direct sunlight, rain and snow. Product does not expire if correctly stored. Sarnafil TS 77-15 2/6

Technical Data Product Declaration EN 13956 Visible defects Pass EN 1850-2 Length 20 (-0 / +5 %) m EN 1848-2 Width 2 (-0.5 / +1 %) m EN 1848-2 Straightness 30 mm EN 1848-2 Flatness 10 mm EN 1848-2 Effective thickness 1.5 (-5 / +10 %) mm EN 1849-2 Mass per unit area 1.65 (-5 / +10 %) kg/m² EN 1849-2 Water tightness Pass EN 1928 Effects of liquid EN 1847 chemicals, including water On request External fire performance ENV 1187 Part 1-4 B ROOF (t1) < 20 EN 13501-5 Reaction to fire E EN ISO 11925-2, classification after EN 13501-1 Hail resistance EN 13583 rigid substrate flexible substrate 22 m/s 30 m/s Joint peel resistance 300 N/50 mm EN 12316-2 Joint shear resistance 500 N/50 mm EN 12317-2 Water vapour transmission properties μ = 150'000 EN 1931 Tensile strength EN 12311-2 longitudinal (md) 1) 1000 N/50 mm transversal (cmd) 2) 900 N/50 mm Elongation EN 12311-2 longitudinal (md) 1) 13 % transversal (cmd) 2) 13 % Resistance to impact EN 12691 hard substrate 700 mm soft substrate 900 mm Resistance to static load EN 12730 soft substrate 20 kg rigid substrate 20 kg Tear strength EN 12310-2 longitudinal (md) 1) 300 N transversal (cmd) 2) 300 N Dimension stability EN 1107-2 longitudinal (md) 1) 0.2 % transversal (cmd) 2) 0.1 % Foldability at low temperature -30 C EN 495-5 UV exposure Pass (> 5000 h) EN 1297 Exposure to bitumen 1) Pass pren 1548 1) Sarnafil T is *compatible to old bitumen 1) md = machine direction 2) cmd = cross machine direction Sarnafil TS 77-15 3/6

System Information System Structure Wide range of accessories is available e.g. prefabricated parts, roof drains, scuppers and walkway pads. The following materials are strongly recommended: Sarnafil T 66-15 D Sheet for detailing Sarnafil TS 77 strips Sarnafil T Metal Sheet Sarnabar Sarnafil T Welding Cord Sarnafil T Prep / Sarnafil Wet Task Set Sarnacol T 660 Solvent T 660 Sarnafil T Clean Application Details Substrate Quality The substrate surface must be uniform, smooth and free of any sharp protrusions or burrs, etc. The supporting layer must be compatible to the membrane, solvent resistant, clean, dry and free of grease and dust. Metal sheets must be degreased with Solvent T 660 before adhesive is applied. Application Conditions / Limits Temperature Compatibility The use of Sarnafil TS 77-15 membrane is limited to geographical locations with average monthly minimum temperatures of -50 C. Permanent ambient temperature during use is limited to +50 C. Sarnafil TS 77-15 may be installed on all thermal insulations and levelling layers suitable for roofing. No additional separation layer is required. Probably a fire protection layer is necessary. Sarnafil TS 77-15 is suitable for installation directly on top of existing, carefully cleaned, levelled bituminous roofing, e.g. re-roofing over old flat roofs. Colour changes in membrane surface may occur in case of direct contact with bitumen. In case of existing roof build up needs to be removed, Sarnafil TS 77-15 can be adhered directly on to the bituminous control layer for partitioning and protection of the day work. Sarnafil TS 77-15 4/6

Installation Instructions Installation Method / Tools Notes on Installation / Limits Installation procedure: According to the valid installation instructions of manufacturer for Sarnafil TS 77- types system for mechanically fastened roofs. Fixing Method, linear fastening (Sarnabar): Unroll the Sarnafil TS 77-15 membrane, overlap by 80 mm, weld immediately and fix to the substructure by means of Sarnabars. The type of fastening will be advised by Sika. The spacing of the fasteners is in accordance with the project specific calculations made by Sika. The perimeter piece ends must be secured with the Sarnafil Load Distribution Plate. For protection fasten a piece of Sarnafil TS 77-15 under bar end and plate. Leave a 10 mm clearance between bar ends. Do not fasten in hole nearest bar end. Cover the bar ends with a piece of Sarnafil TS 77-15 and weld. After installation the Sarnabars must immediately be made watertight with a Sarnafil cover strip. At upstands and at all penetrations, the Sarnafil TS 77-15 membrane must be secured with a Sarnabar. The Sarnafil T Welding Cord protects the Sarnafil TS 77-15 roof covering against tearing and peeling of by wind uplift. Fixing Method, spot fastening (Sarnafast): Sarnafil TS 77-15 must always be installed at right angles to the deck direction. Sarnafil TS 77-15 is fixed by means of the Sarnafast fasteners and barbed washers along the marked line, 30 mm from the edge of the membrane. Sarnafil TS 77-15 is overlapped by 120 mm. Welding Method: Before welding the seams are prepared with Sarnafil T Prep. Overlap seams are welded by electric hot air welding equipment, such as manual hot air welding machines and pressure rollers or automatic hot air welding machines with controlled hot air temperature. Recommended type of equipment: Manual: Leister Triac PID; Automatic: Sarnamatic 661 plus. Welding parameters including temperature, machine speed, air flow, pressure and machine settings must be evaluated, adapted and checked on site according to the type of equipment and the climatic situation prior to welding. The effective width of welded overlaps by hot air should be minimum 20 mm. The seams must be mechanically tested with screw driver to ensure the integrity / completion of the weld. Any imperfections must be rectified by hot air welding. Installation works to be carried out only by Sika instructed contractors for roofing. Temperature limits for the installation of the membrane: Substrate temperature: -30 C min. / +60 C max. Ambient temperature: -20 C min. / +60 C max. Installation of some ancillary products, e.g. contact adhesives / cleaners is limited to temperatures above +5 C. Please observe information given by Product Data Sheets. Special measures may be compulsory for installation below +5 C ambient temperature due to safety requirements in accordance with national regulations. Sarnafil TS 77-15 5/6

January, 2009 Value Base All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Construction Ecology, Health and Safety Information Protective Measures Transportation Class Disposal Important Notification Product is non hazardous and not classified as dangerous goods for transportation. Fresh air ventilation must be ensured, when working (welding) in closed rooms. Use protective equipment when welding. The product is not classified as hazardous good for transport. The material is recyclable. Disposal must be according to local regulations. Please contact your local Sika sales organisation for more information. The information, and, in particular, the recommendations relating to the application and enduse of Sika s products, are given in good faith based on Sika s current knowledge and experience of the products when properly stored, handled and applied under normal conditions. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The proprietary rights of third parties must be observed. All orders are accepted subject of our terms and conditions of sale. Users should always refer to the most recent issue of the Australian version of the Technical Data Sheet for the product concerned, copies of which will be supplied on request. PLEASE CONSULT OUR TECHNICAL DEPARTMENT FOR FURTHER INFORMATION. Sika Australia Pty Limited Tel : 1300 22 33 48 www.sika.com.au Sarnafil TS 77-15 6/6