ROOFING ENVIRONMENTAL PRODUCT DECLARATION SARNAFIL S327

Similar documents
ROOFING ENVIRONMENTAL PRODUCT DECLARATION SIKAPLAN ADHERED

ROOFING ENVIRONMENTAL PRODUCT DECLARATION - CRADLE-TO-GRAVE SARNAFIL S 327

ROOFING ENVIRONMENTAL PRODUCT DECLARATION - CRADLE-TO-GRAVE SARNAFIL G 410

PRODUCT DATA SHEET SARNAFIL S 327 ENERGYSMART ROOF MEMBRANE FELTBACK

Environmental Product Declaration According to ISO and ISO 21930

ENVIRONMENTAL PRODUCT DECLARATION

Environmental Product Declaration According to ISO and ISO 21930

ENVIRONMENTAL PRODUCT DECLARATION

Roofing Décor Roof Systems

Duro-Last Single-ply PVC roof membrane

PRODUCT INFORMATION. 1/ Version #4

Sarnafil Décor Roof Systems. Image here

PRODUCT DATA SHEET SIKAPLAN FASTENED ENERGYSMART ROOF MEMBRANE FELTBACK 60 3 oz. FELTBACK

Sarnafil Adhered Single-Ply Roofing Systems

Owens Corning Asphalt Shingles According to ISO 14025

APP-MODIFIED BITUMEN ROOFING MEMBRANE

Environmental Product Declaration. Concrete Masonry Products as Manufactured by Hard Block Factory

IB PVC Single-Ply 50. Technical Data Sheet

World Class Roofing and Waterproofing

Environmental Product Declaration. Precast Concrete Products as Manufactured by Hard Precast Building Systems

ENVIRONMENTAL PRODUCT DECLARATION

Environmental Product Declaration According to ISO and ISO 21930

Performance that Pays. Sustainability that s Smart.

Environmental Product Declaration

ENVIRONMENTAL PRODUCT DECLARATION ROLL FORMED STEEL PANELS

2015 UL LLC. All Rights Reserved

Image here. Roofing Solutions for Health Care Facilities

Sarnafil World Class Roofing Systems /SAR BuyLine 0189

Belgard Pavers Interlocking Concrete Paving Units

Superlite 8x8x16 Normal Weight CMU

ASPHALT SHINGLE ROOFING SYSTEM

Interlocking Concrete Pavers and Paving Slabs

Superlite 8x8x16 Medium Weight CMU

KANGLEY ROCK & RECYCLING

TECHNICAL BULLETIN TARGET MARKET ROOFING. Subject: NSF/ANSI 347 Referenced in IgCC #15-9

Midwest Block & Brick

IPC Wall Base UNCPC Code: Builders ware of products According to ISO 14025

Environmental Product Declaration Ultra Spec HP DTM Acrylic Enamels

Environmental Product Declaration

Environmental Product Declaration According to ISO and ISO 21930

IVES PROTECTION PLATES

Environmental Product Declaration According to ISO and ISO 21930

Midwest Block & Brick I Solid Concrete Interlocking Paving Unit. Midwest Block & Brick ENVIRONMENTAL PRODUCT DECLARATION VERIFICATION

Performance that Pays. Sustainability that s Smart.

AdvanTech Flooring & Sheathing

Evaluation Listing CCMC L EverGuard TPO Roofing Products

Single-Ply Roofing Membranes

Avoiding the Landfill

FOR Hertalan Easy Cover COMPANY INFORMATION / DECLARATION OWNER. MRPI code Xxxxxxx. DATE OF ISSUE May 21 th, END OF VALIDITY May 21 th, 2020

Premium Professional

ARCHITECTURAL WOOD DOOR LEAF INTERIOR FLUSH DOOR LEAD LINED CORE, HIGH PRESSURE DECORATIVE LAMINATE (HPDL) FACING

TESTING APPLICATION STANDARD (TAS) STANDARD REQUIREMENTS FOR THERMOPLASTIC OLEFIN ELASTOMER BASED SHEET USED IN SINGLE-PLY ROOF MEMBRANE

RCP Block & Brick 8x6x16 Slump Block CMU

LCN ENVIRONMENTAL PRODUCT DECLARATION 4000 SERIES DOOR CLOSERS (INCLUDES MODELS 4010, 4110, 4020, 4030, 4040XP)

STEELCRAFT F SERIES FRAMES

Environmental Product Declaration

LEED V4 FACT SHEET FOR STEEL PRODUCTS USED IN CONSTRUCTION APPLICATIONS

FOR Hertalan Easy Weld MF COMPANY INFORMATION / DECLARATION OWNER. MRPI code Xxxxxxx. DATE OF ISSUE May 21 th, END OF VALIDITY May 21 th, 2020

SCHLAGE SCHLAGE PROXIMITY MINI-MULLION READER

EFFISUS ECORK INSULATION

YEARS SINCE Firestone UltraPly TM TPO Membranes EXPERIENCE THE ULTIMATE IN COOL ROOFING TECHNOLOGY.

POLYISO ROOF INSULATION BOARD

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA USA TEL (610) FAX (610) GII GAI GCI. GRI Test Method GM21

PVC INNOVATION ENERGY EFFICIENT LONG-TERM PERFORMANCE

General information. Manufacturer

EPD. 3 rd P A R T Y V E R I F I E D. ECO EPD Ref. No.: Owner: ISOKLINKER ApS No.: MD EN Issued: Valid to:

THE SIKA SARNAFIL SUSTAINABILITY PR MISE PERFORMANCE THAT PAYS. SUSTAINABILITY THAT S SMART SUSTAINABLE ROOFING SYSTEMS

Environmental Product Declaration Standard and Noble Blocks with Glass Powder - Montreal Plant (Quebec)

CASSARA SLABS AND BOULEVARD PAVERS

NW STD 20CM GLPW CONCRETE BLOCK

/DUR BuyLine 2998

STAINLESS STEEL HANDRAILS INPRO

Natura Interior Waterborne paint

LCN 4050 SERIES DOOR CLOSERS

ENVIRONMENTAL PRODUCT DECLARATION

UltraPly TPO SA. Product Information. Description: Membrane Preparation: Method of Application: Item Description

Thermoplastic Single Ply & Multi-Ply Roofing Systems

Environmental Product Declaration Ultra Spec 500

LIGHT STRUCTURAL SHAPES

Canvas Office Landscape Wood Storage Pedestal

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

ArcelorMittal Construction Mineral wool sandwich panels

Plate waterproofing; Reservoirs; Support walls and areas subject to infiltration; Landscape projects; Tunnel waterproofing

Firestone UltraPly TPO PREMIUM PROTECTION. PROVEN PERFORMANCE.

ROOFING Sarnamatic 681 THE SMART HOT-AIR THERMOPLASTIC MEMBRANE WELDER

Polyglass SBS Roof Membranes. Performance You Can Count On

EPDM ROOF RESTORATION

Section 7 Waterproofing Roofing Standards

LAMINATED VENEER LUMBER ROSEBURG FOREST PRODUCTS COMPANY

ZIP System Sheathing and Tape

Environmental Product Declaration. NU Green SOYA Particleboard. Product Description. Issued March, 2016 Valid until March, 2021

VON DUPRIN 98/99 SERIES EXIT DEVICES

PANDUIT 4-PAIR COPPER DATA CABLE RISER RATED

OVERHEAD GLAZING ALUMINUM SLOPED CURTAIN WALL

COOL ROOF MARKETS AND PRACTICAL EXPERIENCES. HEINZ MEIER, SIKA SERVICES AG MARCH 10, 2016 QUALICHeCK WORKSHOP, ATHENS

ISO & EN 15804: A1:2013

FABRICATED HOT-ROLLED STRUCTURAL SECTIONS

Environmental Product Declaration Lightweight Blocks with Glass Powder - Milton Plant (Ontario)

TPO-c MEMBRANE (Standard, FR and CLEAN Film)

Transcription:

ROOFING ENVIRONMENTAL PRODUCT DECLARATION SARNAFIL S327

GENERAL INFORMATION COMPANY Sika Corporation Roofing PRODUCT TYPE Single Ply Roofing Membrane PRODUCT Sarnafil S327 roofing membrane, with a finished thickness of 48 mils, 60 mils, 72 mils or 80 mils. MANUFACTURING SITE Canton, MA 02021. EPD SCOPE Cradle-to-gate EPD LIMITATIONS EPDs from different programs (using different PCR) may not be comparable Declarations based on the ASTM SPRM PCR [1] are not comparative assertions; that is, no claim of environmental superiority may be inferred or implied for cradle to gate declarations. DECLARED UNIT 1m2 manufactured, Sarnafil S327 STANDARDS The four declared Sarnafil S327 roofing membrane thicknesses (48, 60, 72 and 80 mils) meet the following standards and requirements ASTM D4434 ENERGY STAR Listed* Title 24 Compliant* Cool Roof Rating Council Listed* FM Approval Miami-Dade County Approval Underwriters Laboratory Inc. Underwrites Laboratories of Canada ANSI NSF 347 Sustainability Assessment for Single Ply Roof Membranes ORGANIZATION Sika Corporation, based in Lyndhurst, NJ, is a leading manufacturer of products and systems for the construction and motor vehicle markets. Sika Corporation s roofing division has more than 50 years of experience manufacturing high quality, thermoplastic (PVC), singleply roofing and waterproofing systems for the non-residential market. Sika is also the only roofing manufacturer to be rated Platinum according to NSF/ANSI 347, the leading consensus sustainability standard. PRODUCT DESCRIPTION AND USE With a track record of performance of over 50 years, Sarnafil roofing membranes are the products of choice for architects, specifiers and building owners who want the peace of mind that comes with buying from the performance leader. Sarnafil S327 roof membrane is a thermoplastic PVC membrane used in mechanically attached systems. Sarnafil S327 is polyester reinforced, which provides the high breaking and tearing strength needed to prevent excessive elongation and sheet deformation under the stresses produced by the wind up-lift of the membrane in this type of system. A unique lacquer coating is applied to the top surface of the membrane which helps to reduce soiling. Sika s Thickness Guarantee Program for all Sarnafil branded membranes guarantees they meet or exceed the labeled thickness, rather than following industry standards, which allows for membranes to be manufactured up to 10% below advertised thickness. MEMBRANE THICKNESS GUARANTEE 5 4 3 2 1 1 Structural Deck 2 Vapor Retarder (if required) 3 Insulation 4 Insulation Fastener 5 Sarnafil S Membrane *white, tan, light gray only

PRODUCT SPECIFICATIONS TECHNICAL DATA UNITS ASTM TEST METHOD ASTM D4434 TYPE III REQUIREMENT VALUE/TEST RESULTS 48 MILS 60 MILS 72 MILS 80 MILS Weight [kg/m2 ] 1.7 2.0 2.4 2.6 Total Recycled Content (both pre and post consumer) 3 [%] 10 3 Reinforcing Material Polyester Overall Thickness [mil] D751 45 48 60 72 80 Reflectivity [%] ASTM C1549 0.83 4-0.63 5 Emissivity [%] ASTM C1371 0.90 4-0.86 5 Solar reflective index (white) 104 4-75 5 Breaking Strength (M.D.), min. [lbf/in]. (KN/m) Elongation at Break, min D751 D751 200 (35) 295 305 315 325 Machine Direction [%] 15 27.5 28.5 29 29.5 Cross Direction [%] 15 28.5 29.5 30 30.5 Seam Strength, min., (% of original) 6 [%] D751 75 Pass Retention of Properties After Heat Aging [%] D3045 Tensile Strength, min., (% of original) [%] D751 90 Pass Elongation, min., (% of original) [%] D751 90 Pass Tearing Strength (C.D.), min [lbf] (N) D1004 45 (200) 47 48 48.5 49 Low Temperature Bend, 40 F ( 40 C) D2136 Pass Pass Accelerated Weathering Test (Fluorescent Light, UV exposure) G154 5,000 hours 10 000 hours Cracking (7x magnification) None None None Discoloration (by observation) Negligible Negligible Negligible Crazing (7x magnification) None None None Linear Dimensional Change (C.D.), % D1204 0.5% max. 0.10 0.12-0.13 0.14 Weight Change After Immersion in Water, % D570 ±3.0% max. 2.2 2 1.8 1.8 Static Puncture Resistance, 33lbf (15 kg) D5602 Pass Pass Pass Dynamic Puncture Resistance, 14.7 ft lbf (20 J) D5635 Pass Pass Pass 3 Pre-consumer material: roofing membrane trimmings from Sika s manufacturing process and market supplied post-industrial PVC scrap material. Post-consumer material: post-consumer Sika Sarnafil scrap material and old roofs (10% minimum content) 4 New Membrane 5 3 year aged membrane 6 Failure occurs through membrane rupture not seam failure

Life Cycle Stages 1 2 PRODUCT STAGE Included in System Boundary A1: Raw Material Supply A2: Transport A3: Manufacturing CONSTRUCTION STAGE Module not declared,exclude from the System Boundary A4: Transport A5: Construction/Installation Process STAGES INCLUDED IN THIS LIFE CYCLE ASSESSMENT (LCA) STAGES EXCLUDED FROM LCA 4 END OF LIFE STAGE Module not declared,exclude from the System Boundary C1: De-construction/Demolition C2: Transport C3: Waste Processing C4: Disposal 3 USE STAGE Module not declared,exclude from the System Boundary B1: Use B2: Maintenance B3: Repair B4: Replacement B5: Refurbishment B6: Operational Energy Use B7: Operational Water Use SYSTEM BOUNDARY INCLUDED EXCLUDED A1-A3 Extraction and processing of raw materials, including fuels used in product manufacturing; Transportation of raw materials including empty backhauls; Manufacturing of the product; Packaging of product ready for shipment; Transportation from manufacturing site to recycling/reuse for pre-consumer wastes and unutilized by-products from manufacturing, including empty backhauls; and Recycling/reuse of pre-consumer wastes and by-products of production. Capital goods & infrastructure, production equipment, delivery vehicles, lab equipment personnelrelated activities and energy and water use related to company management and sales have been excluded in the scope of the study MATERIAL CONTENT DECLARATION The material average percentage by weight for 1m2 for the Sarnafil S327 48, 60, 72 and 80 mils is provided. MATERIAL AVERAGE PERCENTAGE BY WEIGHT FOR 1M2: SARNAFIL S327 48, 60, 72 AND 80 [MILS] Raw Material Input Total Weight by [%] Lacquer 0.1 PVC Resin new material 41.6 PVC Resin recycled content 13.2 Plasticizer 26.9 Processing aid 0.2 Stabilizer 2.1 Fire retardants 9.2 Pigment 2.8 Polyester fabric (scrim reinforcement) 4.3 Total weight (Input) 100 PACKAGING MATERIAL DECLARED PRODUCT [MILS] 48 60 72 80 Cardboard Core [kg] 0.05 0.05 0.05 0.05 Wooden Pellet [kg] 0.13 0.13 0.22 0.22 PE Film [kg] 0.005 0.005 0.006 0.006 Total [kg/m2] 0.18 0.18 0.27 0.27

PRODUCT SPECIFICATIONS RESULTS SARNAFIL S327 [48 MILS] DECLARED PRODUCT CATEGORY INDICATOR 48 MILS 60 MILS 72 MILS 80 MILS Global Warming Air, incl. biogenic carbon [kg CO2-eq.] 4.70 5.81 6.97 7.73 Acidification potential [kg SO2-Equiv.] 4.15E-02 5.24E-02 6.36E-02 7.09E-02 Eutrophication potential [kg N-Equiv.] 8.08E-04 9.95E-04 1.20E-03 1.33E-03 Smog creation potential [kg O3-Equiv.] 0.275 0.343 0.413 0.458 Ozone Depletion Potential [kg ethene-eq.] 5.394E-08 6.861E-08 8.364E-08 9.338E-08 TOTAL PRIMARY ENERGY CONSUMPTION Nonrenewable fossil [MJ] 114.72 142.02 170.26 188.62 Nonrenewable nuclear [MJ] 6.43 7.76 9.17 10.08 Renewable (solar, wind, hydropower, geothermal) [MJ] 2.19 2.53 2.91 3.16 Renewable (biomass) [MJ] 0.02 0.02 0.02 0.02 MATERIAL RESOURCES CONSUMPTION Nonrenewable materials [kg] 1.33 1.66 2.04 2.22 Renewable materials [kg] 0.18 0.18 0.27 0.27 Fresh water [l] 18.13 21.48 25.09 27.40 WASTE GENERATED Total [kg] 0.25 0.30 0.37 0.42 Additional Environmental Information Sarnafil roofing membranes were the first, and at the time of printing the only, products to achieve platinum certification to the NSF/ANSI 347 Sustainability Assessment for Single Ply Roofing Membranes. The Sarnafil EnergySmart membrane has a highly reflective, lacquercoated surface that can reduce cooling and overall energy consumption in conditioned buildings. Sarnafil roof membranes exceed the cool roof requirements of ENERGYSTAR, California s Building Energy Code (Title 24), LEED and Green Globes. Sika Roofing s Roof Recycling Program has diverted more than 45 million pounds of pre-consumer and post-consumer vinyl membrane from landfill, recycling it back into roofing and waterproofing membrane products. Sarnafil 5 and 10 membranes have been validated by UL Environment to contain an average of 10% recycled content. Sika roofing has been certified as compliant with strict environment, health and safety, and security standards established by the Responsible Care and ISO 14001: 2004. Sarnafil roof membranes help building owners achieve LEED and Green Globes certification

EPD VERIFICATION This EPD was independently verified by ASTM in accordance with ISO 14025: Internal External X Jamie Meil, Research Principal Athena Sustainable Materials Institute 100-119 Ross Avenue Ottawa, Ontario, Canada K1Y0N6 Signed: Program Operator Timothy Brooke ASTM International 100 Bar Harbor Drive West Conshohocken, PA 19428 tbrooke@astm.org Signed: Declaration Holder Sika Corporation Product group Date of Issue Period of Validity Declaration Number 03/01/2016 5 years EPD029 DECLARATION TYPE A Cradle-to-Gate EPD for four selected thicknesses of the Sarnafil S327 roofing membrane (48, 60, 72 and 80 mils). The modules included are A1 to A3. The declaration is intended for use in Business to Business (B-B) communication. PRODUCT APPLICABILITY AND CHARACTERISTICS The declared Sarnafil S327 roofing membrane thicknesses (48, 60, 72 and 80 mils) are designed for low-slope and steep slope roofing applications. The membranes include an internal polyester reinforcement to provide the tear resistance required for mechanicallyfastened roof systems. CONTENT OF THE DECLARATION This declaration follows Section 11, Content of the EPD, ASTM International Product Category Rules for Preparing an Environmental Product Declaration for Single-Ply Roofing Membranes, November 2013. EPD PROJECT REPORT INFORMATION EPD PROJECT REPORT A Cradle-to-Gate Life Cycle Assessment for four thicknesses of Sarnafil S327 (48, 60, 72 and 80 mils), 06/16/2015 LCA AND EPD PREPARED BY: Corporate Poduct Sustainability Sika Services AG Tüffenwies 16 8050 Zurich Switzerland product.sustainability@ch.sika.com PCR INFORMATION PROGRAM OPERATOR REFERENCE PCR ASTM International ASTM International, Product Category Rules for Preparing an Environmental Product Declaration for Single Ply Roofing Membranes DATE OF ISSUE November 2013 PCR REVIEW WAS CONDUCTED BY: Francois Charron-Doucet Quantis International Email : francois.charron@quantis-intl.com

GLOBAL BUT LOCAL PARTNERSHIP WHO WE ARE Sika AG, located in Baar, Switzerland, is a specialty chemicals company with a leading position in the development and production of systems and products for bonding, sealing, damping, reinforcing and protecting in the building sector and the motor vehicle industry. The corporation has subsidiaries in 84 countries, employs 16,000 people worldwide, and has more than 160 manufacturing facilities around the globe. Our most current General Sales Conditions shall apply. Please consult the Product Data Sheet prior to any use and processing. ISO 14001: 2004-Compliant ENERGY STAR for roofing products is only valid in the United States. ENERGY STAR is a trademark of the U.S. EPA. LEED is a trademark of the U.S. Green Building Council. Green Globes is a trademark of the Green Building Initiative. SIKA CORPORATION ROOFING 100 Dan Road Canton, MA 02021 Tel: 800-451-2504 Fax: 781-828-5365 usa.sarnafil.sika.com webmaster.sarnafil@us.sika.com