Copyrighted Home Plan 2011 Natural Element Homes, LLC

Similar documents
Copyright 2002-present, Natural Element Homes CABIN (2224)

Copyrighted Home Plan 2011 Natural Element Homes, LLC

RESPONSIBILITY OF THE BUILDER/OWNER

Copyrighted Home Plan 2011 Natural Element Homes, LLC

Copyright 2002-present, Natural Element Homes CABIN (2224)

RESPONSIBILITY OF THE BUILDER/OWNER

Copyrighted Home Plan 2011 Natural Element Homes, LLC

Copyright 2002-present, Natural Element Homes naturalelementhomes.com CABIN (2224)

Main Floor Plan Scale: 1/8"=1'-0"

B and H Cedar Log Homes, L.L.C. 65 Nottingham Dr.

CRM Homes BUILDER Mangan Drafting Jim Mangan

DATE: 4/1/2014 SCALE: 3/16"=1'- 0" SHEET:

Customer A101. Front Elevation. Roof Peak 24' /32" Roof 17' - 6" Main Floor 9' - 6" Floor Joist 8' - 6" Basement 0' - 6" Grade 0' - 0"

Equine Barn LLC 213 Crescent Moon Way Canton, Ga Proposal

Left Elevation. Front Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,842. Scale : 1/4" = 1'

Homestead B FRONT ELEVATION SECOND FLOOR FIRST FLOOR SQUARE FOOTAGE HEATED FIRST FLOOR 1678 SQ.FT. SECOND FLOOR 1086 SQ.FT.

Values That Matter PLAN CERTIFICATION WORKSHEET

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

Dining Room. 13'-0" x 14'-6" Kitchen. 2x6 Plumbing Wall 5'-1" Bench & Hooks 8'-2 1/2" 5'-4" Rear Entry. Laundry Room. 5'-3" x 9'-2" 7'-0" x 9'-0"

Staff Review Date: July 12, 2017 HDC PID#

Up Hill House. Cambridge, New York. Title: Cover. Scale: NA. Date: 19-Apr-2010 A-0

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

206 Basic Construction Management

30 YR. ASPHALT ROOF SHINGLES HARDIE PLANK LAP SIDING SEE FIRST FLOOR PLAN FOR PORCH ROOF FRAMING DETAILS 3'-0" 2-2 X 8 HEADER COVERED PORCH 9'-4"

9'-2 1/2" 72" Whirlpool Tub Unit 6'-0" 9'-2" x 11'-6" Bathroom. 66" Vanity. 60" Shower 5'-0" 5'-8" Laundry Room 9'-2" x 5'-7" 5'-7 1/2"

6" TRIM AT GARAGE DOORS (TYP) 6" TRIM (TYP) OPTIONAL PATIO DOOR

Habitat for Humanity FRONT ELEVATION RIGHT ELEVATION LEFT ELEVATION REAR ELEVATION. Vandenburg Lot #9. 1 of 7 JCOOK NOTED ELEVATIONS 3/10/15

ARCHITECTURE DARK HORSE GOLF CLUB CLUBHOUSE A4 EXTERIOR ELEVATIONS FRONT PERSPECTIVE / EAST ELEVATION REAR DECK PERSPECTIVE / WEST ELEVATION

ADDITIONS TO EXISTING RES. & DUPLEX

Rossetti Development LLC RS Builders and Developers LLC Standard Specifications For Tinty Farms, Farmington

QUINN COMMONS. Quinn Ln. SOLD

Great Southern Log Homes

One and Two Family Additions

EXW3 EXISTING DOWEL NEW FOOTING TO EXISTING WALL WITH 3-15M DOWELS, DOWEL THE NEW

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

Applying for Permits to build a new house in Linn County

EADO SQUARE STARTING AT $294,900. Contact: Maggie Houston at

EADO SQUARE. Contact: Maggie Houston at

PORCH PLAN. Existing House. New Porch. Page A.1. Boxed Beams. 5/4x6 Cedar Decking. Roof Overhang. Wood Columns. Hip Roof. Step

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

800 Payson Drive. Oleg Derkach. Single Family Residence A00 STREETSCAPE ELEVATION. 3D View 2 PCDC SUBMISSION

Price, plans, and specifications are subject to change without notice. MAPLE 2,081 SQ.FT. 3 BEDROOMS 3.5 BATHROOMS 2 STORIES

T T LEGAL DESCRIPTION: LEGEND X FOUND MONUMENT AS NOTED A.M. ~ AS MEASURED IN FIELD REC. ~ DEED OR PLAT DISTANCE PL ~ PROPERTY LINE FF ~ FINISHE

A.ENVELOPE AIR SEALING

COOPERSMITH COURT. For more information, contact: Maggie Houston

COOPERSMITH COURT. For more information, contact: Maggie Houston

Price, plans and specifications are subject to change without notice. Revised 01/2018

Carpentry. The following describes the scope and sequence of instruction for Carpentry.


PLANNING FOUNDATION FRAMING

City of Oviedo Residential Permit Application Guidelines

Bonadio Residence. Renovations to Existing Dwelling: new kitchen. 23 Albert Street Waltham, MA. Addition to existing structure.

Why do we grade dwellings or what is the goal when setting the grade of the dwelling?

Schedule C STANDARD Specifications

DRAFT REPORT STRUCTURAL EVALUATION SINGLE FAMILY RESIDENCE 1 SILVERTHORNE LANE BELLE MEAD, NEW JERSEY PREPARED FOR: MS.

Appalachian Log Structures Construction Cost Estimating Guide

Call for more information

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

MAIN FLOOR PLAN. #G x 14 x 8 Shed - Chicken Coop By SDS-CAD Specialized Design Systems 10'-0" 3'-0" 1'-0" 14'-0" 14'-0" 1'-0" 6'-0" 3'-0"

BUILDING YOUR HOME the right way

standard features Power Exhaust Fans w/light - Both Baths GFCI Receptacles Upgrade Light Fixture - Bath 1 Vanity - Per Lav GFCI Receptacles

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

Chapter 14 - Air Sealing

One & Two Family Residential ADDITIONS


Construction Table of Contents

The Woods at Spring Ridge from the mid $500 s Frederick, Maryland

Cheshire, CT. By: A.M. Napolitano, LLC. Project Manager: Carolyne Sakonchick Ext. 323

APPLICATION FOR FINISHED BASEMENT PERMIT

HOMES FOR SALE. Under Construction. Quality Stick Built Starting at $278,000. Watford City North Dakota WATFORDCITYREALESTATE.

Lot 5. 7 Liam s Lane, Methuen, MA Price: $579,500 Lot: 22,651 SQ FT Home: 2,797 SQ FT

Lot 2. 1 Liam s Lane, Methuen, MA Pre-Construction Price: $579,500 Lot: 17,613 SQ FT Home: 2,797 SQ FT

#G445 Plans, 48'x28' x 10' detached garage with bonus room By SDS-CAD Specialized Design Systems

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

Quality Insulation Installation (QII) Insulation Installation (Page 1 of 4)

REAR ELEVATION FRONT ELEVATION

Décor Design Construction llc

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

One & Two Family Residential NEW CONSTRUCTION Plan Review Checklist

STEEL FRAMING INDUSTRY ASSOCIATION OBSERVATION REPORT PROTOCOL STRUCTURAL FRAMING GUIDELINES FOR THE INSPECTOR

INFORMATION SHEET. Dealer name: Complete mailing address: Complete courier address: (courier will not deliver to P.O. box)

KENSINGTON GREEN THE ELLIE - 2,038 SQ.FT.

The CornerStone Cottage Series

PROPOSED PLAN DEVELOPMENT 2501 WEST HOMER STREET. Guardian Properties, LLC. September 9, 2015

Chapter 13 - Finish Framing

Table of Contents. Page Title

INTERIOR PACKAGED FEATURES: EXTERIOR PACKAGED FEATURES: (4) 2BR/2 Bath Apartments - 1,005 Sq. Ft. Per Apt. Built to Benchmark Specifications.

STANDARD CONSTRUCTION PACKAGE Addendum A REV SITE & EXCAVATION Layout of the foundation and septic system as approved by local and state author

Helms Builders, Inc.

SFR SUBMITTAL REQUIREMENTS

GETTING STARTED... 2 YOUR LIST OF PRODUCTS... 2 WHAT THAT LIST BECOMES... 2 PRODUCTS CREATED AS ENVISIONEER ELEMENTS... 3

Incl. Ft. In. SF Qty. Calcs Item Directions

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

RESIDENTIAL PLAN CHECK LIST

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

RESIDENTIAL ATTACHED CARPORTS BUILDING PERMIT REQUIREMENTS

A 16' x 28' Cottage with two lofts and a bedroom addition. Plans can be modified for simple or expanded layouts.

Transcription:

29'-0" SQUARE FOOTAGE 6'-0" PORCH 3'-0" 6'-0" 2'-0" 3'-6" 8'-0" 2'-4" 3'-8" 6'-7" 3'-11" BCD3756-2 BCA2420T 3-0 9LITE BATH WOOD STOVE 10'-0" 2-4 15'-10 1/2" 3'-11" 6'-0" 11'-9 1/2" 15 R. @ 7 5/8" 14 T. @ 10" BCC3648SA3624T 11'-5 1/2" 2'-4" 2'-4" 11'-5 1/2" BEDROOM 4-2X4 POST WITH SCREW JACK ASSEMBLY TYP @ 3 LOCATIONS CABINET ABOVE GREAT ROOM 5-0 PANTRY 6-0 CLOSET CRAWL SPACE ACCESS 6X12 BEAM DECK 3'-11" 6'-0" 4'-0" 7'-9 1/2" 27'-7" CLOSET 6-0 6X12 BEAM 6-0 SLIDER 6-0 SLIDER MAIN FLOOR PLAN 6'-7 1/2" 2'-11 1/2" 4'-1 1/2" 4'-9" 34'-10" BEDROOM 8'-6" 9'-1 1/2" BATH 18'-3 1/2" 9'-3 1/2" LINE OF LOFT KITCHEN LINE OF LOFT DINING 5'-0" 10'-3 1/2" 9'-3" 6'-3" 11'-10" DW BCC3648SA3624T 3'-8" 21'-8" 3'-8" 0" BCD3756 BCA2430T BCA3630 BCD3756-2 2'-6" 6'-7" 4'-9" 3'-4" 3'-10" 2'-4" 7'-3" 3'-5" 5'-0" 39'-0" HEATED AREAS: FIRST FLOOR... 1108 SECOND FLOOR... 636 HEATED TOTAL... 1744 UNHEATED AREAS: DECK/PORCH AREA... 583 CRAWL SPACE... 1108 NOTE: 1) ALL REPRESENTATIONS OF FIXTURES, EQUIPMENT, MATERIALS, ELECTRICAL, PLUMBING, FASTENERS, ETC. ON CLIENTS DESIGN ARE NOT INCLUDED WITH CLIENT'S PACKAGE PURCHASED FROM TENNESSEE LOG HOMES. ONLY ITEMS SPECIFICALLY NOTED IN TENNESSEE LOG HOMES PURCHASE AGREEMENT WILL BE INCLUDED IN THE MATERIALS LIST AND SUPPLIED TO THE CLIENT. 2) CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE BEGINNING CONSTRUCTION. 3) ALL INTERIOR STUD WALLS ARE NON-LOAD BEARING. 4) ALL DOOR AND WINDOW ROUGH OPENINGS TO BE VERIFIED AS LOGS ARE BEING STACKED. OPENINGS MAY NEED TO BE ADJUSTED BY ADDING OR DELETING DOOR AND WINDOW BUCKS OR BY CUTTING LOGS. 5) EXTREME CARE IN PRE-CUTTING LOG OPENINGS HAS BEEN TAKEN. THE OWNER/CONTRACTOR IS RESPONSIBLE FOR CHECKING AND ADJUSTING OPENINGS WHEN STACKING LOGS. RESPONSIBILITY OF THE BUILDER/OWNER THESE DRAWINGS ARE IN PART DIAGRAMMATIC AND DO NOT SHOW IN DETAIL HOW WORKMANSHIP, MATERIALS AND INSTALLATION OF THE MATERIALS INCLUDING THE FIXTURES AND EQUIPMENT ARE TO BE BROUGHT TOGETHER TO COMPLETE THE "WHOLE" STRUCTURE. IT IS THE RESPONSIBILITY OF THE BUILDER/OWNER TO BUILD THE STRUCTURE TO COMPLY WITH ALL APPLICABLE NATIONAL, STATE, COUNTY AND CITY CODES AS THEY APPLY TO EACH COMPONENT BUILDING GREEN: 1) WHERE POSSIBLE, USE COMPACT FLUORESCENT LIGHTING. 2) USE DURABLE ROOF COVERINGS SUCH AS STEEL OR FIBER CEMENT TO REDUCE THE NECESSITY FOR FUTURE ROOF COVERING REPLACEMENTS. 3) THE USE OF FACTORY BUILT COMPONENTS REDUCES THE AMOUNT OF JOB SITE CUTTING FURTHER REDUCING WASTE. 4) CHOOSE ENERGY STAR RATED APPLIANCES WHENEVER POSSIBLE. 5) USE NATIVE PLANTS DURING LANDSCAPING TO REDUCE THE NEED FOR WATERING AND FERTILIZING. 6) IN ROOF SYSTEMS AND EXTERIOR STUD WALLS, USE THE HIGHEST R-VALUE POSSIBLE. 7) USE LOW-E WINDOWS TO REDUCE HEAT TRANSFER BOB NEAL 14C 8x8 V-V LOG DOVETAIL CORNERS 06/11/10-MESB 08/26/10-MESB 08/30/10-MESB 08/31/10-MESB

12'-6" 16'-5" BCC3756 BCC3756 6'-6" 14'-8" 6'-6" APP. 5' HEAD CLEARANCE LOW CLOSET & STORAGE H/W 3046 3046 13'-6 3/4" 8'-4 3/4" 5'-8" 15 R. @ 7 5/8" 14 T. @ 10" 17'-10" SUPPORT POST TO RIDGE MASTER BEDROOM VAULTED CEILING DN WALK-IN CLOSET BATH 6'-6" 14'-8" 6'-6" HVAC LOFT AREA 8'-5 3/4" 12'-0" 6'-1" 4'-0 3/4"X 4'-0 3/4" 2-BCA4824T 3'-0" 15'-7" 18'-7" SHED DORMER TABLE R1001.17 CRICKET DIMENSIONS ROOF SLOPE 12/12 8/12 6/12 4/12 3/12 NOTE: H 1/2 OF W 1/3 OF W 1/4 OF W 1/6 OF W 1/8 OF W 1) ALL REPRESENTATIONS OF FIXTURES, EQUIPMENT, MATERIALS, ELECTRICAL, PLUMBING, FASTENERS, ETC. ON CLIENTS DESIGN ARE NOT INCLUDED WITH CLIENT'S PACKAGE PURCHASED FROM TENNESSEE LOG HOMES. ONLY ITEMS SPECIFICALLY NOTED IN TENNESSEE LOG HOMES PURCHASE AGREEMENT WILL BE INCLUDED IN THE MATERIALS LIST AND SUPPLIED TO THE CLIENT. 2) ALL SECOND FLOOR STUD WALLS CONSTRUCTED TO CEILING HEIGHT. (TYP) 3) BOX IN FLOOR JOISTS WHERE PLUMBING LINES ARE LOCATED AFTER PLUMBING IS INSTALLED. 4) CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE BEGINNING CONSTRUCTION. CANTILEVER SECOND FLOOR JOISTS FOR LOFT 5) ALL DOOR AND WINDOW ROUGH OPENINGS TO BE VERIFIED DURING FRAMING OF GABLES AND DORMERS. CHIMNEY CRICKET SUPPLIED BY OTHERS OPEN TO AREA BELOW RAILING INSTALLED AS PER LOCAL CODES SECOND FLOOR JOISTS SIT ON TOP COURSE OF LOGS PREMIER PORCH ROOF 4X8 DF @ 32" O.C. HOUSE ROOF 2PLY 11 7/8" TJI 210 @ 16" O.C. 5/8" ROOF SHEATHING PREMIER SECOND FLOOR SYSTEM 4X8 DF @ 24" O.C. 5 1/8"X24" GLU-LAM RIDGE BEAM RECOMMENDED FIXED GLASS FIXED GLASS FIXED GLASS SECOND FLOOR PLAN

CONTINUOUS RIDGE VENT () 4X8 DF TRUSS TO BE CUT ON THE JOBSITE 12 12 12 4.625 FRAMING WITH LOG SIDING CRICKET SUPPLIED BY OTHERS CORNER CAPS 5 12 6X10 PORCH PLATE 6X6 PORCH POST RAILING NOTE: GRADE CONDITIONS TO BE VERIFIED ON SITE FRONT ELEVATION

FINISHED ROOFING () CONTINUOUS RIDGE VENT () RAILING LEFT ELEVATION NOTE: GRADE CONDITIONS TO BE VERIFIED ON SITE STEPS TO GRADE PER SITE CONDITIONS

REAR ELEVATION

CONTINUOUS RIDGE VENT () CORNER CAPS RAILING LOG SIDING AT SUBFLOOR NOTE: GRADE CONDITIONS TO BE VERIFIED ON SITE RIGHT ELEVATION