AIR BARRIERS & WATER-RESISTIVE BARRIERS

Similar documents
Armourwall Stucco Systems

Parex Continuous Insulation (CI)

Master Wall Inc. continuously tests our products and systems to meet the most current building codes.

MASONRY VENEER SYSTEMS

Proof positive. The Science Behind the System.

Acrostop R. Vapor Permeable Air/Water-Resistive Barrier Membrane. Product Bulletin

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

EIFS & Associated Products Test Results. Technical Bulletin

NOVAWRAP ASPIRE Q & A

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

SECTION FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013)

LaHabra Insul-Flex WaterMaster EIFS (Exterior Insulation and Finish) 2016 Page - 2

Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS Specifications

AIR BARRIER SYSTEMS VAPOR-PERMEABLE AND NON-PERMEABLE. Sealed, Smart, and Sustainable WATERPROOFING & BUILDING PRODUCTS COMMERCIAL PRODUCT

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

8/14/2015. Course Description. Course Objectives AIR, WATER, AND MOISTURE MANAGEMENT IN LIGHT COMMERCIAL BUILDING ENVELOPES

SuperiorFlash. masterwall.com PO Box 397 Fortson GA Tech:

Parex EIFS Optimum WaterMaster Optimum WaterMaster LCR Optimum Standard WaterMaster Standard WaterMaster LCR Standard

CSI SECTION Insulation & Finish System - Class PB Water-Drainage Exterior Insulation and Finish System

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION

WRAP. Housewrap is the best practice for protecting a home from wind and water while allowing it to breathe. Norandex makes it easy!

PERM-A-BARRIER VPS. Product Description. Product Data Sheets. Self-adhering vapor permeable air and water barrier membrane

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

Spray Wrap MVP. R Guard

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT:

FastWall WaterMaster Krak-Shield FastWall WaterMaster FastWall Krak-Shield FastWall. FastWall Stucco and High Efficiency Assemblies

Sheathing is limited to glass mat gypsum sheathing, cement board, and CDX plywood. Plywood may require 2 coats of Weatherseal Spray & Roll-on.

SECTION FLUID APPLIED VAPOR PERMEABLE AIR BARRIER MEMBRANE

EXPLORE GEOMETRY AND SPACE

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

SECTION FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013)

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

Fiber WaterMaster Cement Finish Specifications

Spray Wrap MVP. fluid-applied air & water-resistive barrier

Air and Vapor Barrier 3015

2013 COMMERCIAL PRODUCTS

PlyDry is specified by builders who need a perforated housewrap that meets code requirements at a very affordable price...

Finestop RA Vapor Permeable Air/Water-Resistive Barrier Membrane. Product Bulletin

REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT: MASTERSEAL AWB 660 I VAPOR RETARDER, AIR AND WATER-RESISTIVE BARRIER AND FLEXIBLE FLASHING

Gold Bond BRAND Gypsum Sheathing

SECTION SELF-ADHERING SHEET FLASHING

Perm-A-Barrier VPS (Vapor Permeable Sheet)

Compliance for Continuous Insulation, Water Resistive Barriers & NFPA-285 What you need to Know

Enershield -HP Vapor Permeable Air/Water-Resistive Barrier Membrane. Product Bulletin

Proof positive. The Science Behind the System.

breathability to prevent the potential for moisture condensation within exterior walls...

Cat 5 Rain Screen air and water-resistive barrier

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

ZIP SYSTEM Roof & Wall SHEATHING

Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure

Cat 5 air and waterproof barrier

EIFS and Associated Products Test Results

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

Continuous Insulation and Air Barriers for High Performance Walls

Finestop RS Vapor Permeable Air/Water-Resistive Barrier Membrane. Product Bulletin

VB (Vapor Barrier) R Guard

Effective Envelope Design Mitigating Risk with High Performance Panels and Acrylic Flashing Systems

Cat 5 air and water-resistive barrier

The Right Choice for Stucco.

CSI SECTION MVS-CI Masonry Veneer on Continuous Insulation

Technicalbulletin #16

R Guard AIR & WATER BARRIER. FastFlash

How-to: Commissioning Design Reviews for the Building Envelope

1/2 in. (12.7 mm) and 5/8 in. (15.9 mm) glass mesh. It has an exceptionally hard, durable surface that can withstand prolonged exposure to moisture.

XTREME-BOND INSTALLATION SYSTEM

VB fluid-applied air & water-resistive barrier and water vapor barrier

BENJAMIN OBDYKE INCORPORATED

Perm-A-Barrier NPS (Non Permeable Sheet)

SECTION FLASHING AND SEALING FRAMING WITH NON-CHEMICAL TERMITE BARRIERS

Smart Vapor Retarders

SECTION SPRAY FOAM INSULATION

SECTION THERMAL INSULATION

SECTION CEMENTITIOUS SHEATHING

Joint & Seam Filler. R Guard. REGULATORY COMPLIANCE VOC Compliance

SECTION VAPOR PERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE

Commercial Air Barrier Systems

Advanced technologies for enhancing the building envelope. 3M Building and Construction Market

DUPONT TYVEK COMMERCIAL SOLUTIONS

SECTION SPRAY FOAM INSULATION

Guide Specification for the OSI QUAD Window and Door Flashing System

VaproFlashing PRODUCT DATA SHEET

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

VB fluid-applied air & water-resistive barrier and water vapor barrier

StoGuard Air Barrier Installation Manual

B. ICC AC 11 Acceptance Criteria for Cementitious Exterior Wall Coating

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

PERM-FLEX (JC) ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

Impact of NFPA 285 on Air Barrier Specification and Design

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

A. Section includes fluid applied, vapor permeable membrane air barriers.

PART 1 - GENERAL PROJECT NAME SECTION VAPOR PERMEABLE AIR BARRIER

80230 StoColor Coat Sand Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

SECTION VAPOR PERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE

WEIGHT PER PIECE (LBS.)

SPECIFICATION GUIDELINE

The Right Balance of Breathability.

Transcription:

AIR BARRIERS & WATER-RESISTIVE BARRIERS

WeatherTech is a family of high performance waterresistive barriers, air barriers, vapor retarders and waterproofing products. When used in conjunction with properly installed substrates, WeatherTech products provide a superior level of moisture protection for any structure. Available with various levels of permeance and installation options. WeatherTech offers a full line of water-resistive barriers and air barriers to seal the building envelope, protect structural components, and promote healthier indoor air quality. Waterresistive barriers have one primary function: to keep incidental moisture from penetrating into structural components and the wall assembly interior. Preventing moisture intrusion is extremely important, as moisture-sensitive building materials often consisting of gypsum, wood or light gage metal can become severely compromised when exposed to moisture. Durable Moisture Protection WeatherTech products provide continuous protection from incidental moisture. They address many of the concerns associated with sheet based building papers and wraps. Concerns related to lapping errors, tears or seam gaps are eliminated. Terminology Water-Resistive Barrier: A material behind an exterior wall covering that is intended to resist liquid water that has penetrated behind the exterior covering from further intruding into the exterior wall assembly. Designed to provide protection of a structure s substrate from incidental liquid water infiltration. Vapor Retarder: A material or system that adequately impedes the transmission of water vapor under specified conditions. Vapor retarder has replaced the term vapor barrier for all but the very lowest permeance materials. Vapor retarder acknowledges that slowing vapor flow, while not totally blocking it, can also be beneficial. Generally vapor retarders will not exceed 1 perm. Air Barriers: Air barriers resist the flow of air. They prevent energy loss by controlling air infiltration and ex-filtration through the wall. They reduce climate control system loads, thus decreasing energy consumption and lowering utility bills They restrict humid air flow into wall cavities They reduce condensation potential, which can reduce R-value and thus contribute to decrease the risk of corrosion, rot, and mold. Water-Resistive Barrier Air Barrier Vapor Permeable Vapor Retarder Liquid applied barriers outperform sheets goods because they are: Seamless: which eliminates water infiltration risk from horizontal and vertical seams. Continuous: which eliminates the risk of water infiltration from rips and tears. Direct Bonded: no need for screws, nails, staples, or other forms of mechanical attachment. Superior Weatherability: exposure to UV light and moisture during the construction cycle will not compromise their effectiveness. Are not dislodged by air pressures. 2 www.parexusa.com I 866.516.0061

Proven Air Barrier Air barriers isolate interior and exterior environments and limit the amount of air that can infiltrate a structure or leak out of it. According to the USGBC, structures consume 70% of the worlds energy with the majority lost from infiltration and exfiltration of air. The unregulated air flow can disrupt the efficient operation of a building s HVAC system, creating strain on the equipment, thus leading to higher overall energy consumption, and an inconsistent environment for occupants. Heating and cooling costs can be impacted by 30% or more according to the Department of Energy. Because air contains water vapor, there is potential for unregulated air flow to create mold related issues within the wall components that can negatively impact air quality. Historically, many building products such as sheet wraps and papers, wallboards, etc. were considered air barriers. Today, with increasing energy consumption and air quality concerns, their level of performance is no longer adequate. Parex USA s WeatherTech line offers products that combine the water-resistive and air barrier features into one unbeatable offering. Air Infiltration WeatherSeal Performance vs ASTM Required Standards Property Test Method ABAA Criteria WeatherSeal Air Leakage of Air Barrier Assembly ASTM E2178 ASTM E2357 After 4000 pressure cycles Pressure: 75 Pa (1.57 lb/ft 2 ; 0.3 in H2O) Flow rate: < 0.02 L/m 2 *s (< 0.004 cfm/ft 2 ) < 0.04 cfm / ft 2 at 1.57 psf (< 0.2 L / s m2 at 75 Pa) Air Leakage ASTM E283 No Criteria < 0.004 cfm/ft 2 <.00001 L/m 2 *s (<0.00001 cfm/ft 2 ) 400 times greater than required by ABAA 0.0004 cfm / ft 2 at 1.57 psf (0.002 L / s m 2 at 75 Pa) 100 times greater than required by ABAA 3

Vapor Permeability A key factor in moisture management of a building is understanding the atmospheric conditions impacting it. Moisture vapor is always present, with different temperatures and concentrations of moisture (relative humidity) in the air, creating a difference in vapor pressure from interior to exterior environments. Nature always tries to equalize this imbalance, which means that the water vapor will try to migrate from a location of higher concentration to one of lower concentration. This vapor drive flows from high pressure to low pressure across the wall assembly. WARM INSIDE AIR COOL OUTSIDE AIR DEW POINT DEW POINT PLANE: PLANE: POTENTIAL CONDENSATION IN WALL The amount of vapor permeance, or breathablity required for a wall assembly varies depending upon climatic conditions and internal environmental requirements. The vapor drive from higher temperatures and pressures to lower plays a key role in determining the most appropriate type of membrane, permeance requirements, and proper placement within the wall assembly. The most significant determining factor in proper selection of membrane type and position within the wall assembly design will be the geographic location of a structure, which determines temperature and humidity exposures and seasonal conditions. For most wall constructions in most climate zones, vapor permeable products like WeatherSeal should be considered. Low permeance barriers: for some advanced wall designs, such as those for cold climate zones with metal studs, continuous external insulation only and no batt insulation between studs, a low permeance barrier coating like Weather Block on the exterior sheathing may be appropriate as an alternative to a vapor retarder on the indoor side of the framing. That is because in such designs, materials to the interior of the continuous insulation are all warm in winter. Some special hot-humid climate zone wall designs may also benefit from a low vapor permeance barrier. NOTE: WeatherBlock is not to be used when another vapor retarder is on the indoor side of the framing; a double vapor retarder can trap moisture in the wall. In cold climate zones, a vapor retarder, like Parex USA s WeatherBlock, stops water vapor leakage of conditioned air to the exterior. For hot, humid climate zones, it stops infiltration of hot humid air to the interior. For mixed climate zones, vapor permeable products, like WeatherSeal, should be considered. The Weather Tech line offers products that accommodate the need for water-resistive barriers and air barriers with a variety of permeance ranges. CLASS PERMS WEATHERTECH PRODUCTS I - Vapor Barrier 0.1 perm or less WeatherSeal BG II - Vapor Retarder 1.0 perm or less and greater than 0.1 perm WeatherBlock III - Semi Permeable 10 perm or less and greater than 1.0 perm WeatherSeal Trowel-On greater than 10 perm WeatherSeal Spray & Roll-On 4 www.parexusa.com I 866.516.0061

Vapor Retarder Location The vapor retarder membrane - when desired - will be placed on the warm in winter side of the assembly (see illustration below). A misplaced vapor retarder promotes condensation. If a vapor retarder is placed in the wall in a cold-inwinter location, vapor will flow toward it from the interior, be prevented from continuing out of the wall, and condense in the wall. WeatherSeal Spray and Roll-On and WeatherSeal Trowel-On are made to be vapor permeable for this reason. Cold winter climates: Indoor air substantially contains more water vapor than the outdoor air as warm air can hold more water vapor than cold air. As the water vapor migrates towards the exterior, it can get concentrated and cold enough to condense and thus wetting materials in the wall. A material that retards the flow of vapor from the warm indoor air into the wall can prevent that condensation; that is why the vapor retarder is placed to the interior side of stud cavity insulation. COLD OUTSIDE AIR WARM INTERIOR AIR Hot Climates: Some wall designs in the hot-humid climate zone can benefit from lower permeance barriers on the hotin-summer side of wall. The idea is that this is the reverse of the cold climate situation. The vapor drive is from the outside toward the inside, sometimes called reverse vapor drive. However, the potential for trapping moisture must be examined by a dewpoint analysis. VAPOR RETARDER INCORRECTLY PLACED ON THE COLD AIR SIDE OF THE ASSEMBLY. Mixed Climates: Walls in mixed climates are exposed to vapor drives from the inside in winter and from the outside in summer. In a mixed climate, the vapor retarder placement that could be right for summer may be wrong for winter and vice versa and that is why mixed climates generally should not have vapor retarders. Dew Point Analysis Parex USA offers dew point analysis services at no charge for architects, engineers and designers who need guidance in determining the location of potential condensation (where the dew point occurs) within a wall assembly. The wall analysis is based on a variety of factors, including environmental conditions and building materials used. MARINE VERY COLD COLD HOT DRY MIXED HUMID MIXED DRY HOT HUMID 5

Weather Tech Products: WeatherSeal Spray & Roll-On This flagship water-resistive & air barrier is a vapor permeable membrane that offers ease of use, rapid installation, and exceptional flexibility. WeatherSeal Spray & Roll-on is an ABAA certified air barrier designed to maximize the energy efficiency of a structure. Water-Resistive, vapor permeable membrane ABAA evaluated and listed air barrier Code approved for use under EIFS and stucco or any code approved cladding (ESR 2045) One product needed to treat wall joints, rough opening flashings, and the sheathing field Above grade use Ready to use Spray and roll-on application High perm rating WeatherSeal Trowel-On This water-resistive & air barrier membrane is a vapor permeable, trowel applied membrane designed for use over a wide variety of substrates. It is available with or without gauging aggregate for maximum workability. Water-Resistive vapor permeable membrane ABAA evaluated and listed air barrier Code approved for use under EIFS and stucco or any code approved cladding (ESR 2045) One product needed to treat wall joints, rough opening flashings, and the sheathing field Above grade use Ready to use Trowel-On application Available with and without gauging aggregate WeatherBlock Spray & Roll-On This easy to use membrane offers high-performance vapor retarder functionality for use in extreme climate conditions, where prevention of vapor transmission will not trap moisture and is appropriate for the wall design. The product can be easily applied by sprayer or roller, and is available in ready to use 5 gallon Pails. It is used to treat wall joints, rough opening flashing, and the sheathing field to create a continuous, seamless protective membrane. Water-Resistive vapor retarder membrane One product needed to treat wall joints, rough opening flashings, and the sheathing field Above grade use Ready to use Spray and roll-on application 6 www.parexusa.com I 866.516.0061

WeatherDry This multi-function material is a specialized water-resistive, air barrier membrane designed for specialized uses with Parex USA branded EIFS projects and for stucco assemblies over CMU that require moisture protection. Engineered for use on low slope EIFS applications and when extra moisture protection is required for stucco assemblies over CMU. WeatherDry is a trowel applied base coat and adhesive material that can serve a dual-function as a water-resistive leveling coat to enhance surface barrier waterresistance properties while providing a smooth surface for specialty finish applications. Water-resistive, vapor permeable membrane Above grade use Concentrate, add cement Trowel-on application EIFS Base coat and adhesive WeatherSeal BG (Below Grade) This single-component waterproof membrane is designed to provide highperformance below grade protection from positive side water pressure. It allows low levels of moisture vapor to escape to prevent blistering and delamination while prohibiting infiltration of moisture through foundation walls, footings, retaining walls, planter boxes and between slab. Water-resistive vapor retarder Below grade use Seamless waterproofing membrane system Rapid installation and excellent adhesion to damp surfaces Ready for installation without heating or thinning Does not become brittle with age Maintains elastomeric properties at low temperatures Solvent free Anti-microbial additive prevents growth of mold and mildew Ready to use Sprayer, roller, trowel or brush application 7

WeatherTech WRBs Product Guide Product Type WeatherSeal Spray & Roll-On WeatherSeal Trowel-On WeatherBlock Spray & Roll-On WeatherDry WeatherSeal BG Air Barrier X X X X X Vapor Permeable X X X Vapor Retarder / Barrier X X Substrate Glass Mat Gypsum Sheathing X X X Gypsum sheathing X X X OSB X X X Plywood X X X Concrete / Masonry X X X X X Cement Board X X X Used Under Siding X X X X EIFS X X X X Brick X X X Stone X X X Stucco X X X X Panelized Systems X X X Protection / Below Grade Grade Below Grade Use Above Grade Use X X X X Use on EIFS Adhesive for EIFS X X Base Coat for EIFS Application Spray & Roll-On X X X Trowel-On X X X ABAA Evaluated X X X X X Can Be Used Under Can Be Used Over SIDING EIFS BRICK STONE STUCCO Panelized systems Glass mat gypsum sheathing gypsum sheathing OSB Plywood Concrete/ masonry CEMENT BOARD 8 www.parexusa.com I 866.516.0061

WeatherSeal Spray and Roll-On and WeatherSeal Trowel-On Test Results Test Method ICC and ASTM E2570 or ABAA Criteria Results Accelerated Weathering AC 212 Air Infiltration ASTM E2178 25 Cycles followed by Hydrostatic Pressure Test: No water penetration on the plane of the exterior facing side of the substrate. Calculated flow Rate at 75 Pa (1.57 lb/ft 2, 0.3 in H 2 O) = < 0.02 L/m 2 *s (< 0.004 cfm/ft 2 ) Pass: no water penetration <.00001 L/m 2 *s (0.00001 cfm/ft 2 ) at 75 Pa (1.57 lb/ft 2, 0.3 in H 2 O) Air Leakage of Air Barrier Assemblies ASTM E2357 Pass < 0.2 L / s m 2 at 75 Pa) (< 0.04 cfm / ft 2 at 1.57 psf) Pass Air Leakage ASTM E283 No Criteria < 0.004 cfm/ft 2 Freeze Thaw Resistance ASTM E 2485 10 Cycles Pass: No Deleterious Effects Hydrostatic Pressure Test AATCC 127 (Water Column) Resist 21.6 in (55 cm) water for 5 hours before and after aging Pass: No water penetration Elongation ASTM D412 No Criteria 360% Flexibility ASTM D522 No Criteria No Cracking at 1/8 (3 mm) Nail Seal ability, Head of Water ASTM D1970 Pass 5 inches of Water Pass 5 inches of water Pull Adhesion ASTM D4541 110KPa Pass Racking ASTM E72 Deflection at 1/8 in (3.2 mm) Pass: No cracking at field, joints or flashing connection Restrained Environmental Structural Loading Surface Burning Characteristics ICC ES AC 212 / ASTM E2570 ASTM E1233 Procedure A ASTM E84 5 Cycles of wetting and drying 10 Cycles @ 80% design load ICC and ASTM E2568 Flame Spread <25 Smoke Developed <450 Pass: No cracking at field, joints or flashing connection Pass: No cracking at field, joints or flashing connection Flame Spread =0 Smoke Developed =0 Tensile Bond Strength ASTM E2134/ ASTM C297 Minimum 15 psi (104 kpa) Pass: all listed substrates Stainless Steel, Color Coated Aluminum, Galvanized Metal, Copper, Aluminum, Rigid PVC, Parex USA Flashing Membrane Water Resistance ASTM D2247 14 Days Pass: No Deleterious Effects. Water Penetration ASTM E331 2.86 psf (137 Pa) for 15 minutes Pass: 25.4 psf (1216 Pa) for 165 minutes Water Penetration ASTM E331 Tested after Structural Loading, Racking and Restrained Environmental Cycling at 2.86 psf (137 Pa) for 15 minutes No Water Penetration Water vapor transmission ASTM E96 Procedure B Vapor Permeable 7 perms, 12 Perms Weathering ICC ES AC 212 / ASTM E2570 210 hours of UV Exposure, 25 cycles of accelerated weathering, 21.6 in (549 mm) water column for 5 hours Wind Driven Rain F.S. TT-C-555B No Criteria Pass VOC EPA Reference Test Method 24 US EPA, South Coast AQMD and Greenseal Standard 10 g/l Regional Harvest LEED MRc 5.1 100% at all facilities Evaluation of Fire Propagation NFPA 285 In Accordance with IBC Chapter 26 Meet requirements for use on all Types of construction Radiant heat exposure NFPA 268 In Accordance with IBC Chapter 26 No ignition upon 20 minute radiant heat exposure at 1.25 w/cm2. Pass Coverage Wet Mil THICKNESS ParexUSA WeatherSeal Spray & Roll-On 400-500 ft 2 - depending on substrate 10-12 Parex USA WeatherSeal Trowel-On with Gauging 150-190 ft 2 - depending on substrate 35 Parex USA WeatherSeal Trowel-On without Gauging 140-160 ft 2 - depending on substrate 63 Parex USA WeatherBlock 350-400 ft 2 - depending on substrate 10-12 Parex USA WeatherSeal BG 145 ft 2 - depending on substrate 15 Parex USA WeatherDry 90-110 ft 2 as a waterproofing membrane - depending on substrate 80-100 ft 2 as an adhesive - depending on substrate 62.5 9

Additional Benefits: LOW VOC ENVIRONMENT & COMFORT GRADE Premier Warranty WeatherTech products come with a stand-alone 5 year product warranty for moisture protection. The warranty level can be increased when used in conjunction with Parex USA brands of EIFS and Stucco assemblies. Low VOC WeatherTech membranes are low VOC and solvent free, ensuring minimal impact on outdoor and indoor air quality. Below and Above Grade WeatherTech offers products for use above grade as well as below grade. Easy to Apply WeatherTech products can be spray, roller, or trowel applied, allowing the applicators flexibility. Factory tinted material provides easy visual recognition for coverage rates, mil thickness, cure times, etc. Ready To Go All WeatherTech products are ready to use right out of the pail. Except for concentrated formulations, like WeatherDry, which require the addition of cement. ABAA Since August 2011, the WeatherSeal line has been listed by the Air Barrier Association of America (ABAA).Parex USA WeatherSeal Spray & Roll-On and Parex USA WeatherSeal Trowel-On have successfully met or exceeded the multiple tests required to be evaluated and listed with the ABAA. This demonstrates Parex USA s strong commitment to providing high-performance material solutions that meet the most stringent industry requirements. The ABAA represents credibility to the industry, as air and water barrier solutions become an increasingly popular option for energy efficiency. This association also provides the opportunity to work with leaders in building envelope design to ensure the development of sound standards and best practices for quality application. 10 www.parexusa.com I 866.516.0061

Accessories Parex USA 396 Sheathing Tape Non-woven fabric used to tape joints and to flash terminations and rough openings Comes in rolls of 4, 6 or 9 inch widths. Parex USA 365 Flashing Membrane It is a self-sealing, rubberized asphalt membrane that functions as a moisture and air barrier. It functions as a seal and flashing at sills of rough openings, deck framing, etc., interfacing with the building substrate and other weather resistive barriers. Comes in rolls of 3, 6 or 12 inch widths. Parex USA 369 DrainEdge (For use with EIFS) It is a perforated, embossed polyolefin material that allows drainage at the EIFS system termination. Comes in rolls of 7 inch widths. 11

Corporate Office Parex USA, Inc. 4125 E. La Palma Ave., Suite 250 Anaheim, CA 92807 (866) 516-0061 Tech Support: (800) 226-2424 Parex USA, Inc. October 2011 PUSAWTWRBB