IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

Similar documents
STANDARD SPECIFICATION FOR SIGNAL CABLE. A. This Specification provides for single and multi-conductor insulated and jacketed cable for


Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

NEMA Standards Publication No. WC ICEA Publication No. S

ES2000 TUBING Environmental Sealing, Polyolefin, Semirigid, Adhesive-Lined

STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV. Approved by AMERICAN NATIONAL STANDARDS INSTITUTE.

NORMAS DE REFERENCIA AEIC CS 1: ASTM B

Heavy Wall Heat Shrinkable Tubing 5-7. Flame Retardant Heavy Wall Heat Shrinkable Tubing 8. Heat Shrinkable Ends Caps 9

ANSI/NEMA WC ICEA S Standard for Control, Thermocouple Extension, and Instrumentation Cables

SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS3SWU (INCLUDING VARIATION LS3SWUS)

SPECIFICATION FOR FRLS POWER CABLES

WESTERN UNDERGROUND COMMITTEE GUIDE 2.14 (2.14/01/0990)

ANSI/NEMA WC ICEA S Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy

PV Solar Wiring Solutions

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. TB/T Translated English of Chinese Standard: TB/T1484.

DETAIL SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/

*** Supercedes: BECO E and COM , , & ***

UNIFIED FACILITIES GUIDE SPECIFICATIONS

VERSAFIT V2 AND V4 TUBING Polyolefin, Flexible, Heat-Shrinkable, Flame-Retardant

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LSC5FS (INCLUDING VARIATIONS LSC5FSW, LSC5OS, AND LSC5OSW)

SPECIFICATION CONTROL DRAWING

SPECIFICATION FOR 400R WIRE AND CABLE PRODUCTS FOR RAIL AND MASS TRANSIT APPLICATIONS, TIN-COATED COPPER

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

PRODUCT SELECTION LOCATOR

Shrink-Kon Thin Wall Heat Shrinkable Tubing

TTMS MARKER SYSTEM TTMS

RAYCHEM NT-MIL TUBING Modified Chlorinated Polyolefin, Elastomeric, Flexible, Flame Retarded, Heat Shrinkable

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018

Heat-Shrinkable Tubing

WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant

Raychem S1297 and /97 Hot Melt Adhesive

Mecoline IS RDX 5241 F

PERFORMANCE SPECIFICATION SHEET

THERMOFIT RNF-150 TUBING Flexible, Heat-Shrinkable, Flame-Retarded Modified Fluoropolymer

BLACK EPR INSULATED MEDIUM VOLTAGE CABLES. Ronald F. Frank, Eng. Consultant

FP30112WHITE100 Heat Shrink TW Tubing 100' Spool

Flame-retardant, cross-linked polyolefin. Shrink temperature of 120 C. Cat. No.*

RAYCHEM TAT-125 ADHESIVE LINED TUBING Polyolefin, Flexible, Heat-Shrinkable, Dual Wall

SECTION INSULATED WIRE AND CABLE

QUALIFICATION UPDATE. Eric Rasmussen. Quality Cables Since 1854

GEMSCAB INDUSTRIES LIMITED STANDARD PLAN FOR HT XLPE CABLES AS PER IS:7098(PART-II)

Raychem brand Moulded Components Flame Retarded, Semi-Rigid, Heat Shrinkable, Elastomer (-25)

U.V resistance UL Sunlight Resistance. Flame retardant IEC

Cables ELE E L CT E C R T R IC I C A A L L

Tele-Fonika Cable Americas

Rail Wire Guide. Harnessing and Electro-Mechanical Solutions for Demanding, Harsh Environment Applications... LFH FREE

America s Wire Company

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013.

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

11-SDMS-01 REV. 03 ( )

Thermofit MIL-LT Tubing Low Shrink-Temperature Polyolefin, Flexible, Heat-Shrinkable

Glossary Of Terms M-1

Test Report No.: Page 2 of 34

Accreditation Scope by Certification Test Order

Clark Public Utilities

STANDARD FOR CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV

3 MODIFICATIONS TO EXISTING STANDARDS

Hongshang Heat Shrinkable Materials Co., Ltd Issue No.9 Qilin Rd, Nankeng Cun, Bantian, Longgang, Shenzhen Date TECHNICAL REPORT ON

Specification This Issue: Date: Replaces: RT-780_Type-I Issue 5 November 10, 2009 Issue 4. Raychem

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables)

SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA

Data Sheet Flexible Polyolefin Heatshrink Tubing 3:1

Thermofit Polyolefin Molded Components Flame-Retarded. Semi-Rigid, Heat-Shrinkable

SURFACE VEHICLE STANDARD

Halogen Free Environmentally Friendly Heat Shrinkable Wire Identification Sleeves

SECTION MEDIUM-VOLTAGE CABLES PART 1 GENERAL

Test Report No.: Page 2 of 35

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

SPECIFICATION FOR 600 VOLT CONTROL AND POWER CABLE SPECIFICATION NO. 557

Protection of A/C connection using a heat shrinkable jacket

RB 107 Specification DuraSeal Splices

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

PILC Replacement: Getting the Lead Out

Separator, suitable tape between the braid and outer sheath

FEDERAL STANDARD TEST METHODS FOR CABLES AND WIRE, INSULATED

FEDERAL STANDARD TEST METHODS FOR CABLES AND WIRE, INSULATED

project 36 MW 1.0 INTRODUCTION AND PROJECT INFORMATION

POLYMERIC ARMOR DESIGN OF AN IMPROVED PROTECTION TO MECHANICAL STRESSES AND FLUIDS FOR OIL GAS AND PETROCHEM (OGP) APPLICATIONS

Low Smoke Halogen Free cables

THERMOFIT RT-218 TUBING Modified Polyvinylidene Fluoride, Low Outgassing, Heat-Shrinkable

RBK-ILS-125 SCOPE. This Quality Assurance Specification establishes the quality standard for RBK-ILS-125.

26/35kV Copper XLPE Insulation Electric Cable

UL RATED HEAT SHRINK TUBING

3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series

SPEIFICATION RW-2530 Document No TMS 90 SCE Marker

WSD 2038 Issue 4. Specification for ZHSCG-35, Halogen-free, Power Cables for use in Photovoltaic Applications

15 kv EPR Insulated, Jacketed, URD Cable

SECTION GROUNDING AND BONDING

PERFORMANCE SPECIFICATION SHEET

3M Medium-Wall Heat Shrink Tubing IMCSN

3M Medium-Wall Heat Shrink Tubing IMCSN

THERMOFIT AP2000 TUBING HEAT-SHRINKABLE CROSSLINKED MODIFIED POLYOLEFIN, ADHESIVE LINER

THERMOFIT SCL TUBING Polyolefin, Selectively Crosslinked, Semirigid, Heat Shrinkable

PO Box 1081 Monticello, MN Ph Fax

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

Transcription:

TABLE OF CONTENTS SECTION SUBJECT PAGE I. SCOPE...1 II. APPLICABLE DOCUMENTS...1 III. CONDUCTOR...2 IV. SEPARATOR...2 V. INSULATION...2 A. Physical Properties...2 B. Electrical Properties...3 C. Qualification Testing...3 1. Tension Set...3 2. Ozone Resistance...3 3. Flammability Requirements...3 4. Corrosion Tests...3 a) Copper Mirror...3 b) Acid Gas Detection...3 5. Oil Resistance...4 6. Smoke Emission...4 7. Abrasion Resistance...4 8. Crush Resistance...4 9. MC-HL Crush and Impact...4 VI. CONDUCTOR IDENTIFICATION...5 VII. CABLING...5 VIII. OVERALL JACKET/OVERALL SHEATH...5 IX. FINISHED CABLE TEST...6 X. ARMOR...6 XI. CABLE IDENTIFICATION...6 XII. REEL MARKINGS...6 Revision 17 Date: 04/04/13

I. Scope This specification covers cables manufactured in accordance with IEEE Std 45/ IEEE Std 1580-2010. These Power and Distribution, Signal, and Control cables are rated at 600/1000 volts AC or DC. They are manufactured with General Cable s MOR Polyrad XT-125 Type P Marine insulation, and a thermosetting irradiated cross-linked Polyolefin and Arctic-Grade, Enhanced Mud Oil resistant, Chlorosulfonated Polyethylene jacket which have been designed for use on oil rigs, shipboard and associated apparatus. An armor of aluminum or bronze and an overall sheath are also available at the option of the purchaser. cables should be designed, engineered and produced by cable manufacturers that have manufactured these specific cables for a minimum of 15 years. These manufacturers should be actively involved in the standards organizations that support the continued development, safety and quality of cables. II. Applicable Documents The wire and cable manufactured under this specification shall be tested and inspected in accordance with the latest issues of the following standards, as applicable or as modified herein: ASTM B33 Tinned Soft or Annealed Copper Wire ASTM D149 Test for Dielectric Breakdown Voltage and Dielectric Strength of Electrical Insulation Materials at Commercial Power Frequencies CSA C22.2 No. 245/ UL 1309 Cable CSA C22.2 No. 38 Standard for Thermoset Insulated Wires and RW 75 XLPE 600V CSA C22.2 No. 230 TC Standard for Tray Cable IEEE Std 45 IEEE Recommended Practice for Electrical Installation on Shipboard IEEE Std 1580 IEEE Recommended Practice for use on Shipboard and Marine Fixed or Floating Platforms IEEE Std 383 Type Test of Class 1E Electrical Cable, Field Splices & Connectors for Nuclear Power Generating Stations IEEE Std 1202 Standard for Flame Testing of for use in Cable Tray in Industrial and Commercial Occupancies IEC-92-3 Electrical Installations in Ships, Part 3; (Construction, Testing and Installation) IEC 60332-3 A Tests on Electric Under Fire Conditions ICEA S-95-658 ICEA/NEMA Standard for Non-shielded Power Rated 2000 Volt or Less for Distribution of Electrical Energy (NEMA WC 70) NEK 606 for offshore installations halogen-free and/or mud resistant UL 44 XHHW Standard for Rubber Insulated Wire & Cable 1 UL (UBVZ) Shipboard Cable, Marine

III. Conductor Conductors shall be of soft annealed tinned copper per ASTM B33 and shall conform to requirements as listed in the Dimensional Data section of the Type P data sheets. IV. Separator A suitable separator may be used if deemed necessary by the manufacturer. V. Insulation The insulation shall be Polyrad XT-125 Type P Marine, an irradiated cross-linked polyolefin, with a minimum average thickness as listed in the Dimensional Data section of the Type P data sheets. The insulated conductor shall meet the following requirements: A. Physical Properties Unaged Requirement Tensile Strength, Min. PSI Elongation at rupture, Min. % Aged Requirements After air oven 7 days @ 158 C ± 2 C After air oven 7 days @ 121 C ± 2 C Oxygen Bomb 7 days @ 80 C @ 300 PSI Air Bomb 42 hours @ 127 C 80 PSI Heat Distortion, 1 hour @ 200 C Clause 4.3.6.1 CSA Std. C22.2 No. 0.3 Cold Bend, 120 hours @ -55 C 2000 Min. 250 Min. 55 Min. 20% Max. 6 kv - 5 Min. 2

B. Electrical Properties Dielectric Strength per ASTM D-149 3 > 700 V/Mil Insulation Resistance > 5000 Megohms/m = 20,000 Insulation Resistance K Accelerated Water Absorption Gravimetric 7 days @ 70 C 5 MG/in 2 Electrical SIC 24 hours @ 75 C 6.0 Increase in Capacitance 1-14 Days 4.0 7-14 Days 1.5 Stability Factor after 14 Days.5 C. Qualification Testing 1. Tension Set Gauge marks are 4 apart. 10% Maximum 2. Ozone Resistance After 24 hours exposure to an ozone concentration of 0.03% by volume at 90 C ± 2 C, there shall be no insulation cracks. 3. Flammability Requirements Insulated conductors shall pass the flame test described in ICEA S-19-81 and the VW-1 vertical flame test described in UL Subject 44. The maximum afterburn after each flame application shall be no greater than 3 seconds. All multi conductor cables insulated with Polyrad XT-125 Type P Marine insulation and jacketed with thermosetting Chlorosulfonated Polyethylene shall meet the requirements of IEEE Standard 45, IEEE Standard 1580, IEEE Standard 1202 and IEC 60332-2A for flame tests. 4. Corrosion Tests a) Copper Mirror: (Ref. ASTM 2671) A 0.4 gram sample of insulation is placed in the bottom of a 2 inch x 12 inch test tube. A copper coated glass mirror shall be suspended 6 inches over the sample by a thin copper wire. The lower two inches of the test tube shall be heated to 175 C for 16 hours. Requirement: Remove less than 5% of the copper film. b) Acid Gas Detection: A 1.0 mg sample shall be heated to combustion in a closed quartz tube. The resulting gases are drawn through a detector tube (MSA #91636) using a special air sampling pump manufactured by Mine Safety Apparatus Company. The amount of acid gas is determined by measuring the length of the color change in the detector tube. Requirement: 220 PPM/MG typical.

5. Oil Resistance Hot Oil Swell Tests - Insulated wires are premeasured and immersed in a hot oil bath. After the required exposure time, they are removed and measured for the amount of swell. Requirement: A. IRM 902 Oil 100 hours @ 150 C Max. Max. % Swell 60 B. Diesel Oil 100 hours @ 60 C Max. Max. % Swell 60 Note: When tested in accordance with AAR 589 (ASTM #2 Oil at 121 C for 18 hours), the retention of tensile and elongation shall be: Tensile - 70% Minimum Elongation - 90% Minimum 6. Smoke Emission The tests shall be performed in an N.B.S. Smoke Chamber using #12 AWG wire insulated with 45 mils of Polyrad XT Marine. The procedures are per NFPA Standard 258 in the flaming (F) and non-flaming (N) modes. Dm T16 T.9Dm (F) Flaming plus Radiant Furnace 485 1.20 7.15 (N) Non-flaming Radiant Furnace 203 10.3 25.7 Dm = Max. Specified Optical Density T16 = Time to reach critical Ds (Specified Optical Density) T.9 Dm = Time to reach 90% of Dm 7. Abrasion Resistance Rotating Scrap abrader (Ref. MIL-C-915) - A 24 inch specimen is draped over an 8 inch rotating drum with two (2) 90 vee edge abrading tools 180 apart. Failure is detected by electrical contact between abrading tool and conductor. The cable is weighted with a 450 gram weight. Requirement: 2500 cycles minimum 8. Crush Resistance A wire sample is placed between two (2) parallel flat plates and compressed until electrical contact is detected across conductor to the plate. Requirement: 7500 lbs. minimum 9. MC-HL Crush and Impact Meets UL 2225 crush and impact requirements 4

VI. Conductor Identification Conductor identification shall be obtained by Method 1 of ICEA S-95-658, solid colors with tracer stripes when necessary. VII. Cabling Individual conductors shall be cabled together with a lay of 8 to 16 times the overall diameter of the cable layer. When required, non-hygroscopic cable binder tape or cable fillers shall be used to maintain a concentric cross-section. VIII. Arctic-Grade Overall Jacket/Overall Sheath The arctic-grade overall jacket, and when required the arctic-grade overall sheath, will meet NEK 606 ester-based mud oil resistant requirements and be black irradiated cross-linked Chlorosulfonated Polyethylene meeting the following requirements when tested in accordance with IEEE Standard 1580-2010. Jacket & Overall Sheath Requirements Per General Cable Physical Properties IEEE 1580-2010 Table 16 Type CP Jacket Material Thermosetting Thermosetting Chlorosulfonated Polyethylene Chlorosulfonated Polyethylene Physical Requirements Unaged: Tensile Strength, min. psi 1800 2200 Elongation at rupture, min. percent 300 350 Set, max. percent 30 12 Aging Requirements After air oven at C 121 ± 1 121 ± 1 Hours 168 168 Tensile Strength percent of unaged, min. 85 100 Elongation at rupture, percent of unaged, min. 65 90 After oil immersion at C 121 ± 1 121 ± 1 Hours 18 18 Tensile Strength percent of unaged, min. 60 90 Elongation at rupture, percent of unaged, min. 60 90 Cold Bend, no cracks, C (Note 1) -40-55 Cold Impact, C (Note 1) -40-40 Mechanical water absorption, mg/in 2 100 87 ICEA Test Procedure reference S-95-658 S-95-658 NOTE: (1) For test procedures refer to CSA Standard C22.2, No. 38, Clause 6.4.7. The insulation system used for this test shall be representative of the final product. Cable intended for arctic or severe cold application should be capable of passing both cold bend at -40 C and cold impact at -40 C. 5

IX. Finished Cable Test Each completed cable length shall be tested without immersion in water and successfully withstand a 5 minute AC potential in accordance with Table 3-2 of ICEA S-95-658. In addition to the voltage withstand test described above, randomly selected samples shall be tested in accordance with Part 6, ICEA S-95-658 and meet the requirements as stated in this specification. X. Armor When specified, shall be in accordance with IEEE Standard 1580. XI. Cable Identification The surface of the cable shall be printed with the following minimum information at intervals not greater than two feet. Where appropriate, additional print legend markings pertaining to (UL) Type TC, (UL) Type TC-ER, and/or (CSA) Type TC will be included. MOR POLYRAD XT-125 (UL) E85994 BR782 110C XX/C XXAWG OR TC-ER 1 XHHW OR (CSA) 245/1309 FT4 40C 600/1000V OR 600V RW75 XLPE TC 2 OR IEC 60332.3A or (ETL) 109229 YEAR OF MFG SEQUENTIAL FOOTAGE MARK 1 - ER for 3 conductors or more, unarmored 2 CSA Listing - 600V RW75 XLPE TC for 14 AWG and larger, unarmored XII. Reel Markings Each reel to be shipped shall be marked to include the following information in addition to any other information specified by the purchaser: General Cable MOR Polyrad XT-125 Type P Marine Voltage Rating Conductor Size & No. of Conductors Footage on Reel Month/Year of Manufacture 6