AZURA Bio LC. 2 FPLC and Purification Solutions

Similar documents
AZURA Analytical HPLC. 2 What is your HPLC challenge today?

AZURA Bio purification

AZURA Bio purification

How do you maximize purity and yield? 2 Continuous counter-current chromatography

Flexibility with. Preparative HPLC

AZURA Bio purification

AZURA Prep LC. What do you want to purify today?

How can flexibility and process economics be combined in one LC system?

AZURA Analytical HPLC/UHPLC

AZURA Analytical HPLC/UHPLC

Agilent 218 Purification System. Purify your way

PLC Purification Systems

Agilent SD-1 Purification System. Purify your way SD-1

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Reducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies

Agilent 1260 Infinity LC & LC/MS Purification Systems. Purify your way

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

The Agilent 1260 Infinity BioInert Quaternary Pump. Scope of a low-pressure mixing UHPLC pump with Bio-Inert Capabilities

The Contichrom CUBE FPLC System. A Twin-Column Protein Purification System for Batch and Continuous Processing

Scale-up with the Agilent SD-1 Purification System analytical and preparative runs on a single system

Separation Science Built for Biopharma

Performance characteristics of the 1260 Infinity Quaternary LC system

Agilent LC and LC/MS Purification Solutions. Purify your way

Application Note. Fast online SPE purification of Stevia plant extracts. Summary. Introduction. Experimental: Sample extraction

Solutions Guide. MX Series II Modular Automation for Nano and Analytical Scale HPLC And Low Pressure Fluid Switching Applications

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Agilent 1260 Infinity Bio-inert Quaternary LC

Application Note. Authors. Abstract. Biopharmaceuticals

Agilent 1260 Infinity Bio-inert Quaternary LC System. Infinitely better for bio-molecule analysis

Seamless Method Transfer from an Agilent 1260 Infinity Bio-inert LC to an Agilent 1260 Infinity II Bio-inert LC

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

Application Note. Rapid optimisation and development of an automated two-step purification procedure for monoclonal IgG antibodies.

Size Exclusion BioHPLC Columns

Hichrom Limited 1 The Markham Centre, Station Road, Theale, Reading, Berkshire, RG7 4PE, UK Tel: +44 (0) Fax: +44 (0)

Protein Separation with ph Gradients Using Composite Buffer Systems Calculated by the Agilent Buffer Advisor Software

Personal Organic Purification

Gel filtration using ÄKTA start

ÄKTAmicro. GE Healthcare. Modular design based on the proven ÄKTA design platform. ÄKTAmicro chromatography system offers:

HPLC 940-LC ANALY TIC AL TO PREPARATIVE LIQUID CHROMATOGRAPHY SOLUTIONS.

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

The Contichrom HPLC System

Molecular Characterization of Biotherapeutics The Agilent 1260 Infi nity Multi-Detector Bio-SEC Solution with Advanced Light Scattering Detection

Agilent Prep LC Columns for Small Molecules and Biomolecules MAINTAIN RAPID, RELIABLE SEPARATIONS AS YOU SCALE-UP

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.

Preparative, Pilot & Process Columns

Agilent 1290 Infinity II 2D-LC Solution Biopharmaceutical Polymer Analysis. WCBP Jan 2017 Washington, DC

Clone Selection Using the Agilent 1290 Infinity Online 2D-LC/MS Solution

Mass Spectrometry Analysis of Liquid Chromatography Fractions using Ettan LC MS System

Gold Standard for recovery and purity

NanoLC-Ultra system. data sheet. Introducing the NanoLC-Ultra family of high pressure HPLCs for proteomics research

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

Separation of Monoclonal Antibodies Using TSKgel HPLC Columns

Analytical HPLC solutions

Size Exclusion BioHPLC columns Ion Exchange BioHPLC columns

TSK-GEL BioAssist Series Ion Exchange Columns

Understanding the Effects of Common Mobile Phase Additives on the Performance of Size Exclusion Chromatography

Column for High Performance,High-Binding Capacity Ion Exchange Chromatography:TSKgel SuperQ-5PW and Its Applications

Agilent 1260 Infinity Purification Systems. Infinitely better purity and recovery

Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

A Comprehensive Workflow to Optimize and Execute Protein Aggregate Studies

Agilent Max-Light Cartridge Cell Information for G4212A and G4212B DAD

Emulation of the Agilent 1100 Series LC Through Waters Empower Software Analysis of an Analgesic Mixture

CX-1 ph Gradient Buffer

Dynamic Axial compression Liquid Chromatography Columns. Flash MPLC HPLC UHPLC. Proven, scalable technology for classic purification techniques

Size exclusion chromatography for Biomolecule analysis: A "How to" Guide

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Analytical Instrument Qualification According to USP <1058>: Requirements and Examples for the Agilent 1290 Infinity LC System

Fast Preparative Column Liquid Chromatography (PCLC)

Flash Chromatography & Preparative HPLC The right solution for every separation problem

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

High-Throughput LC/MS Purification of Pharmaceutical Impurities

Agilent 1260 Infinity Bio-inert Quaternary LC

Bioprocess Chrom Systems

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , ,

Superdex 200 HR 10/30 INSTRUCTIONS

PATfix TM. Lead the way of your process

Columns for Biomolecules BioLC Column Lines

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

Bio-Scale Mini Affi-Prep Protein A Cartridges, 1 and 5 ml. Instruction Manual. Catalog # ,

HPLC/FLASH Purification ADVANCE THE PACE OF YOUR DISCOVERY TO ACHIEVE THE RESULTS OF TOMORROW

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

ÄKTA pcc 75. General system description. GE Healthcare. Chromatography systems

IC-D3160 Ion Chromatograph

ultra why micro-lc? product note introducing the ExpressLC -Ultra system: UHPLC with all the advantages of micro-lc

TOYOPEARL GigaCap Series

Automated Scouting of Stationary and Mobile Phases Using the Agilent 1290 Infinity II Method Development Solution

Agilent 1260 Infinity II LC ASPIRE TO NEW LEVELS OF EFFICIENCY EVERY DAY IN EVERY WAY

Developing Purification Strategies for the Agilent 1260 Infinity II Preparative LC/MSD System

BÜCHI Labortechnik AG

ÄKTA avant. System components. GE Healthcare. Chromatography systems

ProSEC 300S. Protein Characterization columns

BabyBio S BabyBio Q BabyBio DEAE

An Automated System for At-Line Process Analysis of Biopharmaceutical Fermentation Reactions

Optimizing Purified Sample Recovery on Reverse-Phase HPLC Systems

Contichrom overview. all-in-one purification equipment with a novel process principle. UCB Slough November 12 th 2012

Transcription:

AZURA Bio LC 2 FPLC and Purification Solutions

Flexible and adjustable to your biopurification tasks Fast protein liquid chromatography (FPLC) of bio molecules can be a task. KNAUER offers with AZURA an elaborate biochromatography concept, which builds on our experience and is very adaptable. AZURA Bio LC is designed for performance, flexibility and user friendliness. System solutions range from flow rates as low as 0.02 ml/min up to 1000 ml/min by choosing the appropriate pump from KNAUER. A wide range of flow cells for different detectors allows optimized detection. The unique benchtop cooling feature makes costly cooling compartments unnecessary and enables operation in any lab environment. KNAUER supports you in system configuration and application development. Oligonucleotides Antibodies Other proteins Peptides Biomolecules Enzymes Hormones Vaccines Biosimilars/ Biopharmaceuticals 2

How much product do you want to purify? Contichrom MCSGP Up to 100 ml/min 200 g/day Twin column process www.knauer.net/contichrom Purity AZURA Bio LC Up to 1000 ml/min 5 10 g/day www.knauer.net/azurabio Flexibility Productivity www.knauer.net/smb Feed Multi column process SMB Principle AZURA SMB Up to 500 ml/min 2000 g/day Raffinate Single column process Column Switching Extract Eluent AZURA Bio LC features 2 Isocratic, binary high pressure or quaternary low pressure gradient pumps 2 Pump heads allowing flow rates of up to 10, 50, 100, 250, 500 or 1000 ml/min 2 Bio-inert wetted materials 2 Optional benchtop cooling of glass column and fraction collector 2 Choice of different control software packages: volume-based or time-based 2 A variety of detectors (UV/VIS, DAD, RI) and monitors (conductivity and ph) 2 Wide range of flow cells available, including remote cells with fiber optics 2 Integrated leak management and sensors as well as software, monitoring the solvent supply and waste, provide for safety 3

AZURA Bio LC Purification Solutions Designing tailor-made FPLC purification solutions is very easy with the modular AZURA Bio LC platform. Scalable regarding the purified amount and automatable ranging from basic to sophisticated, you have the choice. Here are a few examples. AZURA Compact Bio LC Flow rate: Max. 10 ml/min or 50 ml/min 1/16 AZURA System features and options Available max. flow rates ml/min 10 50 100 250 500 1000 Low pressure gradient option High pressure gradient option Manual sample injection Automated sample injection module AZURA Compact Bio LC Autosampler with cooling option AZURA Lab Bio LC LPG AZURA Lab Bio LC HPG AZURA Pilot Bio LC 4

Maximum Flowrate AZURA Lab Bio LC Flow rate: Max. 10 ml/min or 50 ml/min 1/16 AZURA Pilot Bio LC Flow rate: Max. 100, 250, 500, or 1000 ml/min 1/8 or 1/4 Automated buffer selection module Column switching module Peak parking module Air sensor option Variable single wavelength detection Variable multiple wavelength detection option DAD detection option Conductivity and ph option Automated fraction collection option www.knauer.net/azurabio 5

What is your idea of straightforward FPLC? The AZURA Compact Bio LC systems were designed for routine separation tasks in research and develop ment. Thanks to the compact design and easy to use PurityChrom Bio software, the systems offer reliable performance and ease-of-use. The AZURA Compact Bio LC systems are resistant to all commonly used buffer solutions since all wetted materials are composed of biocompatible parts. The systems can also be operated with organic solvents typically used in HPLC. 2 AZURA Compact Bio LC Pump with a flow rate of up to 10 ml/min or 50 ml/min UV detector with variable wavelength (190 500 nm) Manual injection valve Isocratic buffer supply 6 www.knauer.net/compactbio

AZURA Compact Bio LC Application Separation of a protein standard by size exclusion chromatography (SEC) Manual injection valve Material and column dimension BioFox 17/1200 SEC, Pre-packed column 300 x 8 mm ID, 15 ml Buffer: 20 mm sodium phosphate buffer ph 7.0, 300 mm NaCl isocratic 0.125 ml/min ambient 10 µl size exclusion chromatography standard (BioRad 151-190) Gradient: Flow rate: Temperature: Injection volume: Sample: 60 5 50 6 40 mau mau 30 3 20 4 2 10 1 0-10 Variable wavelength UV/VIS detector -20 20 40 60 80 100 Minutes Minutes 120 140 \\PC-SPA-BIOLAB1\OL_Projects\AP_Bio_05_2013\Result\151013 BioRad 1200 300mM Nacl 0125mlBioLine_3.rslt\151013 BioRad 1200 300mM Nacl 0125ml.d 1 2 3 4 5 6 Aggregate Thyroglobulin 670 kda gamma-globulin 158 kda Ovalbumin 44 kd Myoglobulin 17 kda Vitamin B12 1.35 kda www.knauer.net/applications 7

How customizable is your LC purification system? 2 AZURA Lab Bio LC AZURA Lab Bio LC is available as isocratic, low pressure gradient (LPG), or high pressure gradient (HPG) system for the purification of biomolecules on a laboratory scale. All modules can be freely combined so that for any task the desired device configuration can be compiled. With AZURA Lab Bio LC you can choose your method: 2 Affinity chromatography 2 Size exclusion chromatography 2 Ion exchange chromatography 2 Hydrophobic interaction chromatography 2 Mixed mode chromatography The AZURA Bio LC pump can be combined with different assistant modules for sample injection, column switching, peak parking and additional buffer and sample selection as well as fractionation. Detectors, monitors and a wide flow cell range enable you to perform accurate detection accompanied by ph and conductivity monitoring regardless of your flow rate. An optional fraction collector is available with or without benchtop cooling. Quaternary LPG Pump P 6.1L with online degasser and buffer blending valve ( page 10) 8 www.knauer.net/lab-bio

AZURA Lab Bio LC Application Automated purification of human antibodies (IgG) by affinity chromatography (AC) and successive size exclusion chromatography (SEC) Eluent Tray with tubing guides Assistant ASM 2.1L for switching tasks Assistant ASM 2.1L with sample pump and valves for injection and switching ( page 14) UV/VIS Detector UVD 2.1L with variable wavelength ( page 12) Material and column dimension Hi Trap Protein G, Protein G Sepharose High Performance, 34 µm, 5 ml BioFox 17/1200 SEC, 300 x 8 mm ID, 15 ml Buffer: A 20 mm Sodium phosphate buffer ph 7.5 B 100 mm Glycin HCL, ph 2.7 C 20 mm Sodium phosphate buffer ph 7.0 Method: Gradient Flow rate Affinity 0 26 min 100 % A 0.5 ml/min chromatography Injection and Washing Gel filtration 26 46 min 100 % B 2 ml/min Elution and Peak- Parking 46 86 min 100 % C 1 ml/min Re-injection Temperature: ambient Injection volume: 500 µl Sample: human serum linear Gradient 1 ml/min Tailor your system to make your work easier 2400 2 AZURA Assistant devices may be configured for column switching, peak parking, fraction collection, or as a cost effective isocratic FPLC module: AZURA Compact Bio LC 2 Choose a specific detector depending on your target molecule (UV, conductivity/ph, fluorescence) 2 Choice of AZURA pumps depending on your method and desired flow rate 2 Optional benchtop cooling of glass column and fraction collector 2 Combinable with all common FPLC columns 1600 1 2200 AC SEC 2000 1800 mau mau 1400 1200 1000 3 800 2 600 400 200 0 0 5 10 15 20 25 30 35 40 Minutes Minutes 45 50 55 60 65 70 \\KNET-OL-LIZ4\Enterprise\Projects\AP_BIO_14_2014\Result\BIOLINE_3.91 2014-07-29 14-23-30 (GMT +02-00).rslt\290714500ulserumshortrunpH2.dat, UVD2.1L [2 1 Injection peak affinity chromatography 2 Elution peak human IgG affinity chromatography 3 Elution peak human IgG gel filtration www.knauer.net/applications 9

Choose the gradient and flow rate capabilities you need Pressure Sensor with Inline Filter system protection Buffer Selection Valve two channels for higher flexibility AZURA Mixer highest mixing efficiency 2-Channel Online Degasser reduces baseline noise 2 AZURA Pump P 6.1L Binary FPLC Pump (high pressure gradient) Flow rate range: 0.001 50 ml/min Up to 400 bar Pump heads: 10 or 50 ml/min Automatic recognition of pump heads via RFID Biocompatible, metal-free wetted parts Binary gradient with solvent selection valve (2 x 2 buffers) www.knauer.net/biopumps 10

2 AZURA Pump P 6.1L Quaternary FPLC Pump (low pressure gradient) Flow rate range: 0.001 10 ml/min Up to 400 bar Biocompatible, metal-free wetted parts Quaternary gradients (4 x 1 buffers) Multi-Proportioning Valve precise blending of buffers Pressure Sensor with Inline Filter system protection AZURA Mixer highest mixing efficiency 4-Channel Online Degasser reduces baseline noise 2 AZURA Pump P 2.1L Isocratic FPLC Pump Flow rate range: 0.1 1000 ml/min Pump heads with titanium wetted parts Gradient options: binary high pressure blending (2 x 1 buffers) with an additional P 2.1L or cost-effective binary low pressure blending (2 x 1 buffers) or ternary low pressure blending (3 x 1 buffers, up to 220 ml/min) Exchangeable Pump Heads 11

Which detector do you need for your target molecules? 2 AZURA Detector DAD 6.1L Diode Array Detector User friendly and easy maintenance LightGuide technology Extended wavelength range 190 1000 nm Impressive sensitivity/price ratio Fiber optics version available Versatility through a wide flow cell range 2 BlueShadow Detector 50D Multiple Wavelength Detector Robust multi-channel UV/VIS detector Simultaneous measurement of up to 4 wavelengths Wavelength range from 190 750 nm (extended wavelength range version 190 900 nm also available) Wide linear range 2 AZURA Detector UVD 2.1L Variable Wavelength Detector Wavelength range from 190 750 nm Large choice of flow cells Fiber optics version available Reliable UV/VIS detector for a wide spectrum of applications www.knauer.net/biodetect 12

2 AZURA Detector UVD 2.1S Small Variable Wavelength Detector Very small and compact design Price attractive Can be used in an AZURA Assistant Wavelength range from 190 500 nm Fiber optics version available Flow cells for UV/VIS and DAD detectors Compact and versatile UV detector 2 Flow cells are available for analytical, semi-preparative and preparative applications 2 Exchanging flow cells is easy due to frontal access 2 Fiber optic versions offer the possibility to separate the flow cell spatially from the device providing enhanced security for hazardous, explosive or toxic work processes Type Capillary connection Path length Volume Max. flow rate Max. pressure Analytical 1/16 10 mm 2 µl 5 ml/min 100 bar High sensitivity analytical Semipreparative Wetted materials PEEK, synthetic quartz glass, Teflon Available only for DAD 6.1L PEEK, synthetic Available only quartz glass, Teflon for DAD 6.1L PEEK, synthetic Fiber optics version quartz glass, Teflon also available PEEK, synthetic Fiber optics version quartz glass, Teflon also available PEEK, synthetic Fiber optics version quartz glass, Teflon also available 7 mm 10 bar PTFE, fused silica Available only as fiber optics version 10 mm 10 bar PTFE, fused silica Available only as fiber optics version 1/16 50 mm 6 µl 5 ml/min 100 bar 1/16 3 mm 2 µl 50 ml/min 30 bar Preparative 1/16 0.5 mm 3 µl 250 ml/min 100 bar Preparative 1/8 Variable Variable 1000 ml/min 100 bar Preparative Preparative 3/8 with TRI-Clamp connection 3/8 with TRI-Clamp connection 2 AZURA CM 2.1S Conductivity Monitor For the monitoring of conductivity and ph Flow rates up to 100 ml/min 1 µs/cm 999 ms/cm ph range 2 12 Basic and versatile monitor for biopurification applications Flow cells for CM 2.1S Capillary connection Max. flow rate Max. pressure Analytical 1/16 10 ml/min 160 bar Preparative 1/16 100 ml/min 100 bar 13

How often have you wished for an assistant? 2 AZURA ASM 2.1L Injection Module Assistant Sample pump and automatic injection valve included Injection via a syringe and sample loop or directly via the sample pump Injection of different sample amounts from small to large Sample pump up to 50 ml/min Pump also usable for column filling Optional: 6 port valve for bufferor sample selection or fraction collection Equipped with combinations of valves, pump(s), or detector 2 AZURA ASM 2.1L Column Switching Assistant Two column switching valves included For up to 6 different columns or up to 5 different columns and bypass Optional: 6 port valve for buffer- or sample selection or fraction collection 2 AZURA ASM 2.1L Peak Parking Assistant Two automatic injection valves included Makes peak parking possible Enables back flushing of columns Optional: 6 port valve for buffer selection or fraction collection Collecting your products www.knauer.net/asmbio Depending on the number of fractions and volumes to be collected, you can pick either a fraction collector or a fractionation valve to save your precious products. Fractionation Valves 2 For collecting large quantities 2 Up to 5 fractions and waste 2 Available as a single device or integrated into an ASM 2.1L Fraction Collectors available 2 For up to 288 fractions 2 Choice of rack capacities from two 96-well microplates up to nine 480 ml bottles 2 Cooling optional www.knauer.net/fractionation 14

Do you like to measure based on volume or time? 2 PurityChrom Bio User Friendly Bio LC Software Flexible Method development based on volume, column volume or time Safety features with hold function during running method, display of solvent supply and waste management Approved: 21 CFR part 11 Other supported chromatography data systems with purification function: ClarityChrom, a cost-effective and time-based CDS OpenLAB EZChrom Edition, a time-based client/ server CDS for large networked laboratories www.knauer.net/softwarebio Your FPLC at your finger tips! AZURA Mobile Control enables the control of AZURA Bio liquid chromatography devices. AZURA Mobile Control displays all important parameters of AZURA devices on one screen and works conjointly with the chromato graphy data system OpenLAB and ClarityChrom. The integrated user management ensures that parameters can only be changed by authorized operators. Device settings can be easily changed with sliders or by entering numeric values, for each device and your complete AZURA LC system. A graphical overview of method parameters makes the programming very convenient. Download your demo version here: www.knauer.net/mobilecontrol 15

Pre-packed glass columns for SEC and IEC Ready-to-use glass columns for FPLC are available with different BioFox agarose media. BioFox separation media Separation media for AC, IEC, IMAC or SEC with a pressure stability up to 40 bar (580 psi) for fast and high resolution biochromatography. go to pre-packed FPLC columns go to BioFox separation media Bioline glass columns Bioline glass columns for protein chromatography offer axial compression, high pressure stability, and a thermostatic jacket for easy cooling and heating. www.knauer.net/packedglass Column rack Designed specifically for Bioline high resolution glass columns, the Bioline column rack can also accomodate any conventional LC or MPLC columns. www.knauer.net/biofox go to high-resolution glass columns go to Bioline column rack www.knauer.net/glasscolumns Application support www.knauer.net/fplc-rack Distributed by: Benefit from our long experience in analytical and preparative chromatography and contact us for application support or method development Technical data are subject to change without notice. www.knauer.net/appsupp www.knauer.net HPLC SMB Osmometry KNAUER Wissenschaftliche Geräte GmbH Hegauer Weg 38 14163 Berlin, Germany Phone: +49 30 809727-0 Telefax: +49 30 8015010 E-Mail: info@knauer.net Internet: www.knauer.net KNAUER 2015 V7855US/2.0/01.15/4t