AN EXAMPLE OF LOW-COST DEVICE FOR INDICATIVE INDOOR PM, CO2 AND METEOROLOGICAL PARAMETERS MONITORING

Similar documents
European Network on New Sensing Technologies for Air Pollution Control and Environmental Sustainability - EuNetAir COST Action TD1105

WIRELESS SENSOR NETWORKS FOR AIR- POLLUTION MONITORING IN CITIES

USING LOW-COST SENSORS AND SYSTEMS FOR AIR POLLUTION MONITORING. Viša Tasić

Low-cost air pollution sensors for environmental and occupational health

AIRBORNE PARTICULATE MATTER WITHIN 100 RANDOMLY SELECTED OFFICE BUILDINGS IN THE UNITED STATES (BASE)

Ambient Air Monitoring Systems

IMPACT OF CO 2 CONCENTRATION ON INDOOR AIR QUALITY AND CORRELATION WITH RELATIVE HUMIDITY AND INDOOR AIR TEMPERATURE IN SCHOOL BUILDINGS IN SERBIA

BREATHE A LITTLE EASIER WITH TSI

NEW TRENDS AND CHALLENGES OF AIR POLLUTION MONITORING USING LOW-COST SENSORS: WHAT IDAD LEARNED?

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Summary of air quality sensors and recommendations for application

Good (4 points each) > mg/m Bq m Bq m Bq m -3 < ,000 1,000-10,000 10, ,000

AIR FILTRATION SYSTEM IN AN OFFICE BUILDING: FROM DESIGN TO VALIDATION

What is the status of sensor technology today? The hard truth, experience from laboratory and field

Near reference sensors and their application. February 13 th, 2017 Hannamari Jaakkola, Vaisala Oyj

GRIMM Aerosol Technik Grimm Instrumentation The future of particle measurement Ing. Wolfgang Brunnhuber Environmental Division Manager

Ambient Air Monitoring. Only those who understand particles can take the right measures to protect people and the environment.

AIRBORNE PARTICULATE MATTER AT A BUS STATION: CONCENTRATION LEVELS AND GOVERNING PARAMETERS

Indoor Air Quality Assessments during Renovations at Waverly Elementary School Project #J (January 4, 12, 15, 25 and 29, 2018)

Particulate Monitors and Samplers

Challenges for a New Air Quality Directive: The Role of Monitoring and Modelling Techniques

Indoor Air Quality (IAQ) Measurements and Modeling of Homes during Periods of Intensive Wildfire Smoke

Field and Laboratory Evaluation of an Ozone Sensor

White paper: Indoor air quality and carbon dioxide sensors

Alternative filtration for management of indoor air quality in Seoul metro-subway

Visible emissions were not observed in the school in the vicinity of the construction containment.

Low Cost Monitors: Empowerment, Limitations & Potential. Don Fugler and Michael Taylor

Using Low-Cost PM Sensors for Industrial, Government, and Educational Applications

Particulate Samplers. World Leading Environmental Monitoring Systems

Results and Lessons Learned from Using Low-Cost PM Sensors to Detect Ambient PM 2.5 and PM 10

Visible emissions were not observed in the school in the vicinity of the construction containment.

MEASURED SIZE DISTRIBUTION OF DUST PARTICLES IN A HOUSE FOR FATTENING PIGS summary of measurements

ROCIS: Particle Data Exploration & Insights

3SP_CO_1000 Package

FIDAS FINE DUST MONITORING SYSTEMS. Fidas the world s only certified optical fine dust measurement system with single particle analysis for PM 2.

This document is a preview generated by EVS

The Leader in Performance Indoor Air Quality Measurements

The Leader in Performance Indoor Air Quality Measurements

Evaluating Environmental Monitoring Applications of Low-Cost Sensors for

Results and Lessons Learned from Using Low-Cost PM Sensors to Detect Ambient PM 2.5 and PM 10

PERFORMANCE INDICATORS FOR MONITORING SAFETY MANAGEMENT SYSTEMS IN CHEMICAL INDUSTRY

Supporting Information for: Generation of Nanoparticles from Friction between Railway Brake Disks and Pads

YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM

CO2 transmitters. Introduction 44. CO 2 transmitters 45. CO 2 and temperature transmitters 46. CO 2 transmitters for special applications 47-48

Characteristics of the particulate matter in Riyadh city, Saudi Arabia

Ambient Air Quality and noise Measurements Report Gas pressure reduction station in Marsa Matrouh Governorate

CONCENTRATIONS OF PARTICULATE MATTERS(TSP, PM 10, PM 2.5, AND PM 1 ) AND BIOAEROSOL IN THE ABOVE- AND UNDER-GROUND SUBWAY OFFICES IN SEOUL

OBS-TRPM On Board System Transient PM Mass Measurement

Particle Counters Could Leave Your Business in the Dust 2019 IAQA Annual Meeting

Indoor Air Quality Assessment Report

Particle Size Distribution in the Ambient Air during a Period of High PM10 Immissions

2 nd International Workshop EuNetAir on

SMART SYSTEMS FOR CONTROL AND MITIGATION OF RESIDENTIAL RADON LINKED WITH ENERGY EFFICIENCY IN ROMANIA

Field Comparison of Real-Time PM 2.5 Readings from a Beta Gauge Monitor and a Light Scattering Method

Fine Dust Sensor FDS 15. OUT ma

4 th International Workshop EuNetAir on Innovations and Challenges for Air Quality Control Sensors

FIDAS FINE DUST MONITORING SYSTEMS

Aeroqual AQY 1. micro air quality monitoring system

Ambient Air Quality and noise Measurements Report Gas pipeline network at Farshout- Naqada, Waqf, and Qeft - Qena governorate

SENSORS APPLICABILITY FOR PM 2.5. Nina Ilieva, Yana Nikolova, Ivaylo Predyov, Nikolay Kozarev

Sensor Technologies: Lessons Learned

Proceedings Urban Air Quality Monitoring with Networked Low-Cost Sensor-Systems

Indoor and Outdoor Comparisons of Particle Sizes and Concentrations

Indoor Air Quality in Naturally Ventilated Italian Classrooms

Experience with a low cost NO 2 /O 3 sensor network in Zurich, Switzerland

Environmental Air Quality Exposure Assessment in a Rural Nigerian Village

MEP Engineer's Letter of Assurance

Sensors for indoor air-pollution monitoring

THE IMPACTS OF HUMAN ACTIVITIES ON INDOOR AIR QUALITY IN PASSIVE HOUSES. Ryan Militello-Hourigan, PE Shelly Miller, PhD

MEP's Letter of Assurance

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

Indoor Air Quality Solutions

Wierzbicka, Aneta; Gudmundsson, Anders; Pagels, Joakim; Dahl, Andreas; Löndahl, Jakob; Bohgard, Mats

Environmental Measurements

A Study of Indoor Environmental Quality Parameters in a South Central Kentucky Daycare Facility

INDOOR AND OUTDOOR PARTICLE MEASUREMENTS IN A STREET CANYON IN COPENHAGEN

Overview on Grimm Aerosol Spectrometer for IAQ

Morawska, Lidia and He, Congrong and Hitchins, Jane and Gilbert, Dale. and Parappukkaran, Sandhya (2001) The relationship between indoor and

UPSTATE NY WEATHERIZATION AND EFFECTS ON INDOOR AIR QUALITY

Application of a High Density Low Cost Sensor Network for Air Quality (SNAQ) at London Heathrow Airport

Wireless Distributed Environmental Sensor Networks for Air Pollution Measurement: The Promise and the Current Reality

COUNTING THE WAY TO CLEANER AIR

SCOEH. Particulate Matter: Identification, mitigation and assessment. Michael Riediker Prof., Dr.sc.nat. Founding Director, SCOEH

Assessing Ambient Levels and Personal Exposures in Baltimore: The SEARCH Project

Steven L. Alderman, Michael S. Parsons, and Charles A. Waggoner. Institute for Clean Energy Technology, Mississippi State University

Dekati. ELPI Electrical Low Pressure Impactor. Real-time particle size distribution Wide particle size range Wide range of applications

Title: Standard Operating Procedure for the Continuous Measurement of Ambient PM using a Beta Attenuation Monitor

WGs & MC Meeting at SOFIA (BG), December 2015

AIR FILTERS: REAL WORLD PERFORMANCE

Web Seminar. Indoor Air Quality. Indoor Air Quality and Air Cleaning 19 November Peter DYMENT Camfil Ltd

Project Information. Measure Description

Version Certificate: /

Testing of a Tracer Gas Based Measurement Procedure to Assess Air Change Rates in Buildings

SMART LABS. Reduce Energy Consumption, Improve Lab Safety, and Lower Deferred Maintenance

PERFORMANCE EVALUATION OF SENSORS FOR GASEOUS POLLUTANTS AND PARTICULATE MATTER MONITORING IN AMBIENT AIR CEN TC 264 WG 42 protocol for sensors

INDOOR AIR QUALITY AND ENERGY EFFICIENCY IN THE DESIGN OF BUILDING SERVICES SYSTEMS FOR SCHOOL CLASSROOMS

Body of Knowledge. Indoor Air Quality Practitioner

OUR BRANDS. RENT TO BUY: a smarter solution.

FORUM-AE Workshop 1 Heathrow Airport Particulate Measurements 10th January 2014

Transcription:

European Network on New Sensing Technologies for Air Pollution Control and Environmental Sustainability - EuNetAir COST Action TD1105 WGs and MC Meeting at ISTANBUL, 3-5 December 2014 Action Start date: 01/07/2012 - Action End date: 30/06/2016 Year 3: 1 July 2014-30 June 2015 (Ongoing Action) AN EXAMPLE OF LOW-COST DEVICE FOR INDICATIVE INDOOR PM, CO2 AND METEOROLOGICAL PARAMETERS MONITORING M.Jovašević-Stojanović, D.Topalović, B.Pokrić, T. Popović, M. Živković, I.Lazović, Z.Ristovski COST is supported by the EU Framework Programme Dr Milena Jovašević-Stojanović WG3/WG4 Member Vinča Institute of Nuclear Sciences, University of Belgrade, Serbia mjovst@vinca.rs ESF provides the COST Office through a European Commission contract

DESCRIPTION OF THE UNIT(S) USED IN CITI- SENSE IAQ IN SCHOOLS PILOT STUDY Integration of all parts, electronic design, data transmission and data visualization has been done by Dunavnet (Serbia)-DNET static unit Low cost sensors for selected meteorological parameters (t, RH, p) and gases (NO, NO 2, CO, CO 2, O 3 ) has been produced by Alphasense (UK) Particulate matter monitor (PM 0.5-2.5 and PM 2.5-10 mm) has been produced by DYLOS (USA)

DESCRIPTION OF THE UNIT(S) USED IN CITI- SENSE IAQ IN SCHOOLS PILOT STUDY Calibration in the field, was done by Institute Vinča (Serbia) in cooperation with Serbian Environmental Protection Agency (SEPA) Activities of device validation and data presentation and analysing, performed in cooperation of Institute Vinča (Serbia), DunavNET (Serbia), QUT (Australia)

THE MAIN GOALS OF VALIDATION LOW-COST UNIT WITH GAS AND PM SENSORS IN THE FIELD To adjust for inter-sensor node differences in sensitivity that need to be applied across the range of these concentrations and other conditions without significant bias being introduced To validate consistency after repeated use in conditions with low and high levels of pollutants and meteorological data To compare the sensitivity with reference devices and other widely used commercial instruments

UNIT CALIBRATION WITH REFERENCE INSTRUMENTS Calibration of the DYLOS 1700 monitor for PM10 and PM2.5, was based on colocating it with a reference instrument, the GRIM monitor, at an automatic monitor station that is part of the network run by the Serbian Environmental Protection Agency (SEPA). The data were recorded with same frequency for the DYLOS 1700 platforms and for the reference instruments. Therefore prior to preforming the calibration procedure it was necessary to perform time adjustment, interpolation, the DYLOS data and GRIM monitor data.

UNIT CALIBRATION WITH REFERENCE INSTRUMENTS We have first performed a filtering of the signals from the platforms by using a smooth function precisely described by Gracia* that provide examples of simplified Matlab codes. This allows fast, automatic and robust smoothing of signals with arbitrary dimensions followed by conversion of the count to mass concentration on the basis of aproximative, literature data. Smooth function provides an option to set the input parameter of smoothness which it is possible to control the filtering process. By increasing the smoothness, the correlation coefficient between the signals from the low-cost sensors and reference monitors has improved. *D.Gracia, Computational Statistics and Data Analysis, 54(2010)1167-1178

Conversion count to mass concentration, an conservative approach Conversion to mass concentration was perform under strong assumption: All particles are spherical, with a density of 1.65E12 μg/m 3 [*,**] The radius of a particle in the channel <2.5 μm is 0.44 μm [**,***] The radius of a particle in the channel > 2.5 is 2.60 μm [**,***] *A. Tittarelli, A. Borgini, M. Bertoldi, E. De Saeger, A. Ruprecht, R. Stefanoni, G. Tagliabue, P. Contiero, P. Crosignani Estimation of particle mass concentration in ambient air using a particle counter, Atmospheric Environment, 42 (2008) 8543-8548 **M. Uva, R. Falcone, A. McClellan, E. Ostapowicz, Preliminary Screening System for Ambient Air Quality in Southeast Philadelphia -Data Validation,, Electrical and Computer Engineering Department of Drexel University May 13, 2009 May 13, 2009 (accessed October 2014) ***Lee, J. et al., Seasonal variations of particle size distributions of PAHs at Seoul, South Korea, Air Quality Atmospheric Health, 1 (2008) 57-68 III41028 project III42008 project MESTD, Serbia

UNIT CALIBRATION WITH REFERENCE INSTRUMENTS Dnet static units for were collocated at AMS Novi Beograd March 17 th -April 10 th. platform no CO 2 Ref/pl PM 2.5 Ref/pl PM 10 Ref/pl T Ref/pl H Ref/pl p Ref/pl 7-0,857 0,824 0.924 0,957 0,971 0,997 9-0,838 0,824 0.802 0,971 0,980 0,997 13-0,819 0,853 0.765 0,960 0,973 0,997

PILOT SCHOOL IN BELGRADE:ELEMETARY SCHOOL 20. OKTOBAR, NEW BELGRADE We started with monitoring indoor and outdoor school environment with Dnet unit in spring 2014

SCHOOL ENVIRONMENT INDOOR AIR QUALITY Teachers room

SCHOOL ENVIRONMENT OUTDOOR AIR QUALITY Teachers room

SCHOOL ENVIRONMENT INDOOR AIR QUALITY Teachers room

CO2 AND PM VARIATON DURING SCHOOL OCCUPANCY An example of PM and CO2 variation during weekday PM collected with Osiris monitor, CO2 measured with Testo devce III41028 project III42008 project MESTD, Serbia

AN EXAMPLE OF PM10 AND PM2.5 DAILY VARIATION : SCHOOL INDOOR/OUTDOOR AND SEPA DATA April 29th 2014, school 20 oktobar

AN EXAMPLE OF HUMIDITY DAILY VARIATION: SCHOOL INDOOR/OUTDOOR AND SEPA DATA

PRESSURE INDOOR/OUTDOOR MASUREMETS AT SCHOOL Green outdoor, Blue and red Classrooms

CO2 INDOOR/OUTDOOR MASUREMETS AT SCHOOL Green outdoor, Blue and red Classrooms

AN EXAMPLE OF C02 DAILY VARIATION : SCHOOL INDOOR/OUTDOOR WEEKAY AND WEEKEND April 25 th -30 th 2014, nonoccupied school 20 oktobar May 1 st -5 th 2014, occupied school 20 oktobar

AN EXAMPLE OF PM10 AND PM2.5 DAILY VARIATION : SCHOOL INDOOR/OUTDOOR AN SERIA 2 INDOOR, SERIA 3 OUTDOOR, SERIA 4 -INDOOR

AN EXAMPLE OF PM10 DAILY VARIATION : SCHOOL INDOOR/OUTDOOR AN SERIA 2 INDOOR, SERIA 3 OUTDOOR, SERIA 4 -INDOOR

DATA VISUALISATION FOR SCHOOL PILOT STUDY IN BELGRADE

MOBILE DESIGN SIZERS THAT COVER RESPIRABLE PM RANGE OPS TSI MODEL 3330 Price >10000 EUR Particle range 0.3-10 mm Sized channels up to 16 Gravimetric sampling removable 37 mm cartridge Operational temperature 0 to 45 C Weight ~ 2 kg Nanoparticle sizer TSI SMPS MODEL 3910 Price > 25000 EUR Particle range 0.01-0.42 mm Sized channels 13 Operational temperature 0 to 30 C Weight < 8 kg III41028 project III42008 project MESTD, Serbia

LOW COST PM DEVICE DYLOS DC1700 PRO DC1700 Price 200-300 EUR On screen display Real time monitoring of two sized channels 0.5-2.5 mm and > 2.5 mm Weight 2.5 lb Dimensions 177.9x11.3x76.2 mm Power 4.5 W III41028 project III42008 project MESTD, Serbia

LOW COST PM DEVICE ALPHASENSE OPC-N1 Price ~ 400 EUR Particle range 0.38-17 mm Size category 16 Temperature range -10 to 50 C Weight < 70 g III41028 project III42008 project MESTD, Serbia

DYLOS 1700 PRO: PMS AND PML CHANEL COUINT Real time monitoring of small fraction: 0.5-2.5 mm Real time monitoring of large fraction: > 2.5 mm III41028 project III42008 project MESTD, Serbia

ALPHASENSE OPC-N1: PM FRACTONS <2.5 AND >2.5 mm Real time monitoring of small fraction: 0.4-2.5 mm Real time monitoring of large fraction: > 2.5 mm III41028 project III42008 project MESTD, Serbia

COMPARISION OF ALPHASENSE OPC-N1: AND DYLOS 1700 PRO Real time monitoring of small fraction: < 2.5 mm Real time monitoring of large fraction: > 2.5 mm III41028 project III42008 project MESTD, Serbia

COMPARISION OF ALPHASENSE OPC-N1: AND DYLOS 1700 PRO CALIBRATED DATA Real time monitoring of small fraction: < 2.5 mm Real time monitoring of large fraction: > 2.5 mm III41028 project III42008 project MESTD, Serbia

CORRELATION BETWEEN ALPHASENSE OPC-N1, TSI 3330 AND TSI 3910 Office microenvironment in Institute Vinča III41028 project III42008 project MESTD, Serbia

CORRELATION BETWEEN ALPHASENSE OPC-N1 AND TSI 3330 OPC-N1 PERFOERMANCE DATA, www.apollounion.com/upload/.../upload_downfiles_opc-n1.pdf Office microenvironment in Institute Vinča III41028 project III42008 project MESTD, Serbia

FURTHER ACTIVITIES FOR IAQ IN SCHOOLS For full deployment indoor case study in school we are going to use an new unit where it will be sensors produced by Alphasense for both, gases and PM Beside gases and PM in full deployment we are going to monitor important stressors such there are noise and radon in near real time To update methodology of calibration in the field To compare results from different available unit in the aim of finding optimal solution for analyzing and presenting indicative levels of pollutant and other stressors To create tools for exposure assessment to selecting pollutants in school microenvironment To create data presentation to be useful for education of wide population of schoolchildren about importance of IAQ III41028 project III42008 project MESTD, Serbia