REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER

Similar documents
DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

ESR-1812 Reissued October 1, 2012 This report is subject to renewal November 1, 2013.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

REPORT HOLDER: GYPSUM ASSOCIATION 6525 BELCREST ROAD #480 HYATTSVILLE, MARYLAND EVALUATION SUBJECT:

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS REPORT HOLDER: WORTHINGTON ARMSTRONG VENTURE (WAVE)

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

REPORT HOLDER: GYPSUM ASSOCIATION 962 WAYNE AVENUE, SUITE 620 SILVER SPRING, MARYLAND EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

DIVISION: CONCRETE SECTION: CEMENTITIOUS WOOD FIBER DECKS DIVISION: FINISHES SECTION: ACOUSTIC ROOM COMPONENTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PRODEMA USA INC. EVALUATION SUBJECT:

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: SUZHOU HONGLY HARDWARE CO., LTD.

DIVISION: SPECIALTIES SECTION: DEMOUNTABLE PARTITIONS REPORT HOLDER: KRUEGER INTERNATIONAL, INC.

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

Trusted WOOD I JOISTS SECTION: 06 ON WEB i. Conformity! ICC-ES Evaluation. Copyright 2015

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: OLMAR SUPPLY INC RESEARCH DRIVE LIVERMORE, CALIFORNIA EVALUATION SUBJECT:

Suggested Materials and Tools:

REPORT HOLDER: ispan SYSTEMS LP 70 BRENTWOOD DRIVE PRINCETON, ONTARIO N0J 1V0 CANADA EVALUATION SUBJECT:

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

DIVISION: METALS SECTION: METAL FASTENINGS DIVISION: FINISHES SECTION: FASTENERS REPORT HOLDER: HILTI, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

Joint Evaluation Report

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: REFLECTIX INCORPORATED

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

Joint Evaluation Report

Joint Evaluation Report

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: BORAL COMPOSITES, INC.

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

Suggested Materials and Tools:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

REPORT HOLDER: STAR R FOAM MANUFACTURING, INC. EVALUATION SUBJECT: STAR R FOAM INSULATION BOARDS

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: CPG INTERNATIONAL LLC DBA THE AZEK COMPANY LLC EVALUATION SUBJECT:

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

DIVISION: METALS SECTION: COLD FORMED METAL FRAMING REPORT HOLDER: AEGIS METAL FRAMING, A MITEK COMPANY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

ESR-1061 Reissued May 1, 2011 This report is subject to renewal in two years.

Joint Evaluation Report ICC-ES (800) (562)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT:

REPORT HOLDER: CALIFORNIA EXPANDED METAL PRODUCTS COMPANY (CEMCO) CROSSROADS PARKWAY NORTH, SUITE 325 CITY OF INDUSTRY, CALIFORNIA 91746

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: ULTRALOX 2955 LONE OAK DRIVE, SUITE 180 EAGAN, MINNESOTA 55121

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: CERAMICA LA ESCANDELLA, S.A.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: ULTRAKOTE PRODUCTS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: EQUITONE

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: SPRAY FOAM POLYMERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT:

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: KINGSPAN LIGHT + AIR LLC

Transcription:

0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3207 Reissued 10/2016 This report is subject to renewal 10/2018. DIVISION: 09 00 00 FINISHES SECTION: 09 53 00 ACOUSTICAL CEILING SUSPENSION ASSEMBLIES DIVISION: 13 00 00 SPECIAL CONSTRUCTION SECTION: 13 48 13 MANUFACTURED SOUND AND VIBRATION CONTROL COMPONENTS REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO 43017 EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2016 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-3207 Reissued October 2016 This report is subject to renewal October 2018. A Subsidiary of the International Code Council DIVISION: 09 00 00 FINISHES Section: 09 53 00 Acoustical Ceiling Suspension Assemblies DIVISION: 13 00 00 SPECIAL CONSTRUCTION Section: 13 48 13 Manufactured Sound and Vibration Control Components REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO 43017 (614) 889-0480 www.kineticsnoise.com EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER 1.0 EVALUATION SCOPE Compliance with the following codes: 2012 and 2009 International Building Code (IBC) Properties evaluated: Fire-resistance-rated construction Structural 2.0 USES The WAVE Hanger is a hanger used to support gypsum board ceilings in interior floor/ceiling assemblies of wood frame construction,. WAVE Hangers may be used in fireresistance-rated horizontal assemblies in accordance with IBC Section 712 when installed as described in Section 4.2.2. 3.0 DESCRIPTION WAVE Hangers are formed,, gypsum board ceiling hangers made from heat-treated and plated spring-steel. WAVE Hangers are available in two models, WAVE 22 and WAVE 44. The WAVE 22 Hanger has a silver zinc coating and the WAVE 44 has a black phosphorous coating. These coatings are primarily used for model differentiation in the field. WAVE Hangers are formed from 1050 annealed spring-steel heat-treated to Rc 40-43 hardness specifications. The steel for the WAVE 22 is 0.030 inch (0.76 mm) thick and the steel for the WAVE 44 is 0.042 inch (1.07 mm) thick. A typical WAVE Hanger is shown in Figure 4. WAVE Hangers support standard 7 / 8 -inch-tall (22.2 mm), No. 20 gage, drywall furring channels and flex approximately 1 / 2 inch (12.7 mm) when under rated allowable design load. The hangers have a 0.22-inchdiameter (5.59 mm) hole at each end for the No. 10 by 1.5-inch-long (38.1 mm) Round Washer, Recex, Lo Root Lubricized screws that are provided by Kinetics Noise Control to attach the hangers to the underside of wood structural members of the floor/ceiling assemblies. Seismic restraint plates manufactured from No. 18 gage galvanized sheet metal, 7 / 16 inch (11.1 mm) wide and 2 1 / 4 inches (57 mm) long with a screw hole on each end, must be used to secure the drywall furring channels against lateral movement when WAVE Hangers are installed in buildings in Seismic Design Category B, C, D, E, or F locations. 4.0 DESIGN AND INSTALLATION 4.1 Design: The WAVE 22 and WAVE 44 Hangers are designed to carry 4 square feet (0.37 m 2 ) and 8 square feet (0.74 m 2 ), respectively, of ceiling consisting of two layers of 5 / 8 -inchthick (15.9 mm) gypsum board attached to No. 20 gage furring channels. The allowable tributary loads to be supported by the WAVE Hangers must not exceed 22 pounds (97.9 N) for the WAVE 22 Hanger and 44 pounds (196 N) for the WAVE 44 Hanger. The WAVE Hangers are for use in Seismic Design Category A, or for use in other seismic design categories when accompanied by the seismic restraint plates described in Section 3.0. 4.2 Installation: 4.2.1 General: Drywall furring channels must be spaced across the ceiling at a maximum of 24 inches (610 mm) on center. The furring channels must not be fastened directly to the ceiling framing. To support the channels, WAVE Hangers must be spaced at maximum 48-inch (1220 mm) intervals and must be fastened to the bottom of ceiling framing using two screws, described in Section 3.0, for each hanger. WAVE 22 and WAVE 44 Hangers must be laid out to support the ceiling in such a way as not to exceed weight limits and spacing limits established above. WAVE 22 Hangers must carry the smaller areas of the ceiling, typically at the perimeter and corners, where tributary loads are 22 pounds or less. Channels around the perimeter of the ceiling must be installed at a maximum of 6 inches (152 mm) from ceiling edges; WAVE Hangers at these locations must be centered within 6 inches (152 mm) of the edges. In Seismic Design Categories B, C, D, E, and F, restraint plates must be installed to prevent lateral movement of the channels relative to the hangers. Seismic restraint plates ReICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 4 1000

ESR-3207 Most Widely Accepted and Trusted Page 2 of 4 must be installed across the adjacent WAVE hanger and fastened directly to the channel on each side using No. 10 by 3 / 4 -inch (19.1 mm), hex head, self-drilling screws as shown in Figure 5. See the manufacturer s published installation instructions for plate spacing. The gypsum board must be fastened to the furring channels in accordance with the requirements for the assemblies described in Section 4.2.2. The perimeter of the ceiling must be caulked with a nonhardening, resilient caulking in accordance with the manufacturer s published installation instructions. 4.2.2 One-hour Fire-resistance-rated Floor Construction: The assemblies shown in Figures 1, 2, and 3, qualify as one-hour fire-resistance-rated floor/ceiling construction, provided the structural members are installed and loaded in accordance with the manufacturer s recommendations. Nominally 3 / 4 -inch-thick tongue-and-groove structural panel subfloor must be installed perpendicular to framing, with ends staggered. The subfloor is glued with adhesive meeting APA Standard AFG-01, and is screwed to framing using No. 10 by 2 1 / 2 -inch-long (64 mm) wood screws installed at 6 inches (152 mm) on center at edges and 12 inches (305 mm) on center in the field. The subfloor may be fastened using 8d nails as an alternative to the screws. The insulation used in the fire assemblies must be 0.5 pcf (8 kg/m 3 ) minimum density fiberglass, with a thickness between 3 1 / 4 inches (83 mm) and 6 1 / 4 inches (159 mm), stapled to the underside of the subfloor or laid across the top of the drywall furring channels. The gypsum board used in the fire-resistance-rated assemblies must be National Gypsum Company s 5 / 8 -inchthick (15.9 mm) Fire-Shield Type C gypsum board installed in two layers. The base layer must be installed staggered with the long dimension perpendicular to and fastened along the furring channels with No. 6 by 1 1 / 4 -inch-long (31.8 mm), Type S, high and low thread, bugle-head drywall screws at 12 inches (305 mm) on center in the field and 8 inches (203 mm) on center at butted ends. The face layer must be installed with the long dimension perpendicular to the channels, and must be staggered and off-set from the base layer by 12 inches (305 mm) in both directions. The face layer must be fastened through the base layer to the furring channels with No. 7 by 2-inch-long (51 mm), Type S, fine thread bugle-head drywall screws at 12 inches (305 mm) on center in the field. The butted ends of the face layer must be fastened using No.10 by 1 1 / 2 -inch-long (38.1 mm), Type G, bugle-head drywall laminator steel screws set back 1 1 / 2 inches (38.1 mm) from the ends, and installed at 8 inches (203 mm) on center. Joint compound must be applied to the face layer in two coats at joints, using drywall tape, and at screw heads in accordance with ASTM C840 or GA-216. 5.0 CONDITIONS OF USE The WAVE Hangers described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with this report, the manufacturer s published instructions and the applicable code. In the event of a conflict between the manufacturer s published installation instructions and this report, the more restrictive governs. 5.2 The WAVE hangers must be manufactured, identified and installed in accordance with this report and the manufacturer s published installation instructions. A copy of the instructions must be available at the jobsite at all times during installation. 5.3 Fire-stopping and draft-stopping must be provided in accordance with the applicable code. 5.4 The gypsum board must not be fastened directly to the ceiling framing. 6.0 EVIDENCE SUBMITTED 6.1 Reports of fire resistance testing in accordance with ASTM E119. 6.2 Reports of load capacity testing based on ASTM D1761. 6.3 Engineering calculations. 6.4 Quality control documentation. 7.0 IDENTIFICATION The products described in this report are identified with the Kinetics name die-stamped on each piece along with the model number and lot number. The boxes of WAVE Hangers are identified with the evaluation report number (ESR-3207), the name of the report holder (Kinetics Noise Control) and the model number.

ESR-3207 Most Widely Accepted and Trusted Page 3 of 4 FIGURE 1 FIRE RESISTANCE ASSEMBLY NO. 1 FIGURE 2 FIRE-RESISTANCE ASSEMBLY NO. 2 FIGURE 3 FIRE-RESISTANCE ASSEMBLY NO. 3

ESR-3207 Most Widely Accepted and Trusted Page 4 of 4 FIGURE 4 KINETICS NOISE CONTROL WAVE HANGER FIGURE 5 SEISMIC RESTRAINT PLATE