TEST REPORT. EVALUATION CENTER Intertek Testing Services NA Inc Murphy Drive Middleton, WI 53562

Similar documents
TEST REPORT. REPORT NUMBER: MID-001b REPORT DATE: November 10, 2016

RENDERED TO PRODUCT EVALUATED:

RENDERED TO PRODUCT EVALUATED:

RENDERED TO PRODUCT EVALUATED:

RENDERED TO PRODUCT EVALUATED:

TEST REPORT SCOPE: EMISSIONS, EFFICIENCY AND OUTPUT FUEL: EPA TEST FUEL (CRIBS) TEST STANDARD: EPA MODEL: SOLUTION 2.

TEST REPORT SCOPE: EMISSIONS, EFFICIENCY AND OUTPUT FUEL: EPA TEST FUEL (CRIBS) TEST STANDARD: EPA MODEL: S245E WOOD STOVE

Report on Testing of the Econoburn Model EBW Wood Hydronic Heater using Partial Thermal Storage

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: March 13, 2017 REVISED DATE:

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: April 30, 2013 REVISED DATE:

How to choose the best furnace?

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: December 18, 2012 REVISED DATE:

RENDERED TO SLEEPY HOLLOW CHIMNEY SUPPLY, LTD. 85 EMJAY BLVD. BRENTWOOD, NY 11717

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

REPORT NUMBER: SAT-002A ORIGINAL ISSUE DATE: August 16, 2017 REVISED DATE:

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-04 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS. We Identify and S.T.O.P. Your Noise Problem

REPORT NUMBER: SAT-004A ORIGINAL ISSUE DATE: April 13, 2017 REVISED DATE:

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: October 30, 2014 REVISED DATE:

Southwest Clean Air Agency NE 99 th St, Suite 1294, Vancouver, WA 98682

RENDERED TO. CastleRock Building Products Incorporated P.O. Box 1258 Meridian, ID USA 83680

Woodstove Retrofit Efficacy Testing OMNI Report# 0323WS001N. Prepared for:

REPORT NUMBER: SAT-001A Rev 1 ORIGINAL ISSUE DATE: November 16, 2010 REVISED DATE: June 20, 2011

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: March 13, 2013 REVISED DATE:

REPORT NUMBER: SAT-001A ORIGINAL ISSUE DATE: December 29, 2011 REVISED DATE:

REPORT NUMBER: SAT-001D ORIGINAL ISSUE DATE: February 24, 2012 REVISED DATE:

Measurement of Space-Heating Emissions. Prepared for:

ASTM E84-05 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS

Alabama Department of Environmental Management Air Division Planning Branch Emission Measurement Section

Method 28 Fuel Moisture Measurement Evaluation. prepared by:

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-04 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS. We Identify and S.T.O.P. Your Noise Problem

Guidance for Portable Electrochemical Analyzer Testing Used for Compliance Monitoring

ENGINEERING EVALUATION

Particulate emissions determined using the dilution tunnel method should be entered in cell C13 of the "Data" sheet as total grams of emissions.

EMISSION MEASUREMENT TECHNICAL INFORMATION CENTER NSPS TEST METHOD. Method 10 - Determination of Carbon Monoxide Emissions from Stationary Sources

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-03 SURFACE BURNING CHARACTERISTICS. We Identify and S.T.O.P. Your Noise Problems

TEST REPORT. Acoustical Surfaces, Inc. ASTM E84-03 SURFACE BURNING CHARACTERISTICS. We Identify and S.T.O.P. Your Noise Problem.

REPORT NUMBER: MID-005 ORIGINAL ISSUE DATE: Nov 22, 2016 REVISED DATE: na

METHOD 1A - SAMPLE AND VELOCITY TRAVERSES FOR STATIONARY SOURCES WITH SMALL STACKS OR DUCTS. NOTE: This method does not include all of the

DICKSON COATINGS FIRE TEST REPORT

SHOWER WALLS S.A. DE C.V. FIRE TEST REPORT

Sale and Installation of Wood-Burning Appliances and the Use of Certain Wood-Burning Appliances during High Pollution Days

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK Order No Date: May 24, 2008 REPORT NO CRT-001

PUSHING THE LIMITS OF WHAT IS POSSIBLE

Wood & Pellet ECONOMIZER BIOMASS PRODUCTS

State of New Hampshire Department of Environmental Services Air Resources Division. Temporary Permit

STACK AND BREECHING GUIDELINE

METHOD BERYLLIUM SCREENING METHOD. Analyte CAS No. Sensitivity Beryllium (Be) Dependent upon analytical procedure used

EMISSIONS FROM OUTDOOR WOOD-BURNING RESIDENTIAL HOT WATER FURNACES

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK Order No October 15, REPORT NO CRT-002d3

DICKSON COATINGS FIRE TEST REPORT

Method For Test-Fueling Residential Wood-Fired Masonry Heaters and Bake Ovens

LISTING INFORMATION OF Metl-Span, LLC THERMALSAFE 8" Thick 3 Hour Fire Rated Panels SPEC ID: 29868

ARTICLE 13: SOLID FUEL BURNING DEVICE STANDARDS

Portable Infrared Flue Gas Analyzer Gasboard 3800P

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

27.0 SAMPLING AND TESTING METHODS

LISTING INFORMATION OF Metl-Span, LLC THERMALSAFE 4" Thick 1 Hour Fire Rated Wall Panels SPEC ID: 29555

Wood & Pellet ECONOMIZER STOVES & INSERTS

GENERAL MECHANICAL SYSTEM REQUIREMENTS

(3) Flares used to comply with provisions of this chapter shall be operated at all times when emissions may be vented to them.

MILLENNIUM METALS, INC TEST REPORT

Case Study: Pulse Jet Fabric Filter & Dry Sorbent Injection for Biomass Boiler Application

LISTING INFORMATION OF Epilay - Superior, Ultra and Platinum Roofing Underlayments SPEC ID: Epilay Inc S. Main Street, E1 unit C

Code Compliance Research Report CCRR-0225

REPORT NUMBER: SAT-001 ORIGINAL ISSUE DATE: March 23, 2010 REVISED DATE: NA

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: FIRE ROCK PRODUCTS LLC

Sample ID: Description Model Number: Sample 1 C&M Airfree air cleaner P1000

LNG Research Study. Gravity Vented Wall Furnace (Legacy) November Prepared By:

testo 350. For emission testing and combustion analysis. Portable Emission Analyzer

Property Condition Assessment

GENERAL MECHANICAL SYSTEM REQUIREMENTS

FUNDERMAX GMBH LETTER OF RESULTS

Method Implementation Document (MID 1948)

County of Yolo Development Services Building Inspection Division

METHOD 17 - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM STATIONARY SOURCES. NOTE: This method does not include all of the

Efficiency and Particulate Matter Emissions Testing of Wood Burning Heating Units

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES

Method X: Determination of Metal Concentrations in Emissions from Stationary Sources (Instrumental Analyzer Procedure)

Test Report TR1R0

Indoor Air Quality and Mechanical Ventilation (Page 1 of 5)

2015 International Mechanical Code Errata (Portions of text and tables not shown are unaffected by the errata)

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

Impact of Thermal Storage on Pellet Boiler Performance

Test Report TR1R1

ASTM E84-09 SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS

LISTING INFORMATION OF ClarkDietrich Wall Assembly Design No. CD/WA SPEC ID: 26053

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: MASONRY FIREPLACE INDUSTRIES, LLC

Code Compliance Research Report CCRR-0106

Residential Data Collection Checklist 2009 International Energy Conservation Code Climate Zone 2

Title V. Model General Permit Template SERIES 1 FLARES. Template # SJV-FL-1-1

WESTERN SPINDLE LLC TEST REPORT

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

REPORT NUMBER: SAT-001A_Rev.2 ORIGINAL ISSUE DATE: April 7, 2015 REVISED DATE: July 21, 2015

Code Compliance Research Report CCRR 0232

FIBERGRATE TEST REPORT

Code Compliance Research Report CCRR-0257

Evaluation of The Northern Sonoma County Wood-Burning Fireplace and Masonry Heater Emissions Testing Protocols

F Prepared by: Elan Frantz. Prepared for: Pacific Gas. PO Box and Electric Company

A furnace that fits your lifestyle

Food Service Technology Center

Transcription:

TEST REPORT REPORT NUMBER: 102741836MID-001bR2 REPORT DATE: October 24, 2016 REVISED REPORT DATE: August 7, 2017 REVISED REPORT DATE: August 11, 2017 REVISED REPORT DATE: September 6, 2017 EVALUATION CENTER Intertek Testing Services NA Inc. 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Lamppa Manufacturing 512 S. 3rd Street PO Box 422 Tower, MN 55790 PRODUCT EVALUATED: MODEL VAPOR FIRE 100 WOOD FORCED-AIR FURNACE Report of Testing Model Vapor Fire Wood Forced-Air Furnace for compliance as an Affected Wood Heater with the applicable requirements of the following criteria: CAN/CSA B415.1-2010 Performance Testing of Solid-Fuel-Burning Heating Appliances, ASTM E2515-11 Determination of Particulate Matter Emissions Collected by a Dilution Tunnel, EPA 40 CFR Part 60 Standards of Performance for New Residential Wood Heaters, New Residential Hydronic Heaters and Forced- Air Furnaces, March 16, 2015, and U.S EPA Alternate Test Method for the model Vapor Fire 100. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. 1

Project No. G102741836 Page 2 of 16 Contents I. INTRODUCTION... 4 I.A PURPOSE OF TEST... 4 I.B LABORATORY... 4 I.C DESCRIPTION OF UNIT... 4 I.D REPORT ORGANIZATION... 5 II. SUMMARY... 5 II.A PRETEST INFORMATION... 5 II.B INFORMATION LOG... 6 II.B(1) TEST STANDARD... 6 II.B(2) Deviation from Standard Method... 6 II.C SUMMARY OF TEST RESULTS... 7 II.D DESCRIPTION OF TEST RUNS... 7 II.D SUMMARY OF OTHER DATA... 8 TABLE 1. DATA SUMMARY PART A... 8 TABLE 2. DATA SUMMARY PART B... 8 TABLE 3. WEIGHTED AVERAGE... 9 TABLE 4. - GENERAL SUMMARY OF RESULTS... 9 TABLE 5. CSA B415.1 RESULTS... 9 III. PROCESS DESCRIPTION... 9 III.A TEST SET-UP DESCRIPTON... 9 III.B AIR SUPPLY SYSTEM... 9 III.C TEST FUEL PROPERTIES... 10 IV. SAMPLING SYSTEMS...10

Project No. G102741836 Page 3 of 16 IV.A. SAMPLING LOCATIONS... 10 IV.A.(1) DILUTION TUNNEL... 11 IV.B. OPERATIONAL DRAWINGS... 12 IV.B.(1) STACK GAS SAMPLE TRAIN... 12 IV.B.(2). DILUTION TUNNEL SAMPLE SYSTEMS... 13 V. SAMPLING METHODS...13 V.A. PARTICULATE SAMPLING... 14 VI. QUALITY ASSURANCE...14 VI.A. INSTRUMENT CALIBRATION... 14 VI.A. (1). DRY GAS METERS... 14 VI.A.(2). STACK SAMPLE ROTAMETER... 15 VI.A.(3). GAS ANALYZERS... 15 VI.B. TEST METHOD PROCEDURES... 15 VI.B.(1). LEAK CHECK PROCEDURES... 15 VI.B.(2). TUNNEL VELOCITY/FLOW MEASUREMENT... 16 VI.B.(3). PM SAMPLING PROPORTIONALITY... 16 VII. CONCLUSION...16 REVISION SUMMARY DATE August 7, 2017 August 11, 2017 September 6, 2017 SUMMARY Revised Table 1 Data Summary Part A, Actual Load. The percentage of maximum output was corrected to indicate what the actual output percentage was for each category based on the maximum output. Revised Section II.C Summary of Test Results, CO Emissions. Changed CO emission result from a weighted average of 101.59 g/hr to a weighted average of 0.82 g/min per the 2015 NSPS. Revised Table 3 Weighted Average, CO Emissions. Changed the column for CO emissions from g/hr to g/min and added the corrected results in g/min. Revised Section VII Conclusion. Conclusion was changed from compliance with Step 1 limits to compliance with Step 2 limits and added rational based on the EPA alternate test method. Revised cover page to include reference to the EPA Alternate Test Method. Updated Section I.A to include reference to the EPA Alternate Test Method. Updated Section II.B(2) to explain the use of the EPA Alternate Test Method.

Project No. G102741836 Page 4 of 16 I. INTRODUCTION Intertek Testing Services NA (Intertek) has conducted testing for Lamppa Manufacturing, on model Vapor Fire 100 Wood Air Furnace to evaluate all applicable performance requirements included in Determination of particulate matter emissions from wood forced-air furnaces. I.A PURPOSE OF TEST The test was conducted to determine if the unit is in accordance with U.S EPA requirements under EPA 40 CFR Part 60 Standards of Performance for New Residential Wood Heaters, New Residential Hydronic Heaters and Forced-Air Furnaces. This evaluation began on 9/19/16 and was completed on 10/04/16. The following test methods were applicable: ASTM E2515-11- Standard Test Method for Determination of Particulate Matter Emissions Collected by a Dilution Tunnel CSA B415.1-10 - Performance Testing of Solid-Fuel-Burning Heating Appliances U.S. EPA Alternate Test Method issued to Lamppa Manufacturing for the Vapor Fire 100. I.B LABORATORY The tests on the model Vapor Fire 100 Wood Forced-Air Furnace were conducted at the Intertek testing Services Laboratory located at 8431 Murphy Drive, Middleton, WI, 53562. The laboratory is accredited by the U.S. EPA, Certificate Number 3. The test was conducted by Ken Slater and observed by Daryl Lamppa of Lamppa Manufacturing. I.C DESCRIPTION OF UNIT The model Vapor Fire 100 Wood Forced-Air Furnace is constructed of sheet steel. The outer dimensions are 53-inches deep, 52-inches high, and 27-inches wide. The unit has a door located on the front of the unit. (See product drawings.) Proprietary drawings and manufacturing methods are on file at Intertek in (Intertek location)

Project No. G102741836 Page 5 of 16 I.D REPORT ORGANIZATION This report includes summaries of all data necessary to determine compliance with the regulations. Raw data, calibration records, intermediate calculations, drawings, specifications and other supporting information are contained in appendices to this report. II. II.A SUMMARY PRETEST INFORMATION A sample was submitted to Intertek directly from the client. The sample was not independently selected for testing. The test unit was received at Intertek in Middleton, WI on July 28, 2016 and was shipped via the client. The unit was inspected upon receipt and found to be in good condition. The unit was set up following the manufacturer's instructions without difficulty. Following assembly, the unit was placed on the test stand. Prior to beginning the emissions tests, the manufacturer operated the unit for a minimum of 50 hours at highto-medium burn rates to break in the heater. This break-in period was witnessed by Lamppa Manufacturing s staff and a signed document is included in the final report. The unit was found to be operating satisfactory during this break-in. The 50 plus hours of pre-burning were conducted from July 22, 2016 to July 24, 2016. The fuel used for the break-in process was wood. Following the pre-burn break-in process the unit was allowed to cool and ash and residue was removed from the firebox. The unit's chimney system and laboratory dilution tunnels were cleaned using standard wire brush chimney cleaning equipment. On September 19, 2016 the unit was set-up for testing.

Project No. G102741836 Page 6 of 16 II.B INFORMATION LOG II.B(1) TEST STANDARD From 9/19/16 to 10/04/16, the unit was tested for EPA emissions. For Wood Forced-Air Furnaces, the test was conducted in accordance with CSA B415.1-2010. The fuel used for the test run was Oak cordwood. The applicable EPA regulatory limits are: Step 1 2016 0.93 lbs/mmbtu Output (0.4 g/mj) For furnaces rated less than 65,000 Btu/hr Step 1 2017 0.93 lbs/mmbtu Output (0.4 g/mj) For furnaces rated more than 65,000 Btu/hr Step 2 2020 0.15 lbs/mmbtu Output (0.026 g/mj) II.B(2) Deviation from Standard Method The Step 2 requirements for EPA 40 CFR Part 60 Standards of Performance for New Residential Wood Heaters, New Residential Hydronic Heaters and Forced-Air Furnaces specifies that a wood forced-air furnace must be operated at the output rates as noted for wood burning hydronic heaters. The Step 2 output rates indicate <15% of maximum output for Category 1, 16-24% of maximum output for Category 2, 25-50% of maximum output for Category 3, and 100% of output for Category 4. Lamppa Manufacturing submitted a request to the U.S. EPA to allow the Vapor Fire 100 to operate at the output rates specified in CSA B415.1-2010 and still comply with the Step 2 requirements of EPA 40 CFR Part 60. The U.S. EPA issued an Alternate Test Method, written by Steffan Johnson, to Lamppa Manufacturing permitting the use of the output rates as outlined in CSA B415.1-2010. The approved output rates are <35% of maximum output for Category 1, 35-53% of maximum output for Category 2, 53-76% of maximum output for Category 3, and 100% of output for Category 4. The set-up, operation procedures, and the output rates for the model Vapor Fire 100 was performed in accordance with applicable clauses from CSA B415.1-2010.

Project No. G102741836 Page 7 of 16 II.C SUMMARY OF TEST RESULTS The appliance tests resulted in the following performance: Particulate Emissions: 0.093 lbs/mmbtu Output (0.040 g/mj) Carbon Monoxide Emissions: 0.82 g/min Heating Efficiency: 54.3% (Higher Heating Value Basis) II.D DESCRIPTION OF TEST RUNS RUN #1 (9/19/16) Air control set at full open position. Due to an unexpected power failure the test was discontinued. RUN #2 (9/20/16) Air control set at full open position, burn time was 356 minutes with a category 4 burn rate of 2.558 kg/hr. The test was loaded and the door closed. Final Btu rate was 34,567 with a 0.0429 lb/mmbtu. RUN #3 (9/21/16) Air control set to level 2 position with the thermostat set at 125 F, burn time was 550 minutes with a category 2 burn rate of 1.748 kg/hr. The door was closed. Final Btu reading was 13,517 with a 0.244 lb/mmbtu. RUN #4 (9/22/16) Air control set to level 2 position with the thermostat set at 125 F, burn time was 490 minutes with a category 2 burn rate of 1.918 kg/hr. The door was closed. Final Btu reading was 14,414 with a 0.145 lb/mmbtu. RUN #5 (9/23/16) Air Control set to level 2 position with the thermostat set at 125 F, burn time was 549 minutes with a category 2 burn rate of 1.635 kg/hr, The door was closed. Final Btu reading was 17,372 with a 0.033 lb/mmbtu. RUN # 6 (9/29/16) Air control set to low setting with the thermostat set at 135 F, burn time was 421 minutes with a category 1 burn rate of 2.114 kg/hr, The door was closed, Final Btu reading was 18,906 with a 0.172 lb/mmbtu. Btu is higher than category 1 burn rate therefore this test is a category 2. RUN # 7 (9/30/16) Air Control set to level 2 setting with the thermostat set at 145 F, client removed hi-limit switch, burn time was 611 minutes with a category 1 burn rate of 1.463 kg/hr, The door was closed, Final Btu reading was 9,332 with a 0.147 lb/mmbtu. RUN #8 (10/03/16) Air control set at medium position with the thermostat set at 105 F. Due to an unexpected power failure the test was discontinued.

Project No. G102741836 Page 8 of 16 RUN #9 (10/04/16) Air control set at medium position with the thermostat set at 105 F. Burn time was 465 minutes with a category 3 burn rate of 1.999 kg/hr. The door was closed. Final Btu reading was 25,236 with a 0.092 lb/mmbtu. Standard specifies that tests can be averaged, therefore test run #3 and #6 will not be used, Test runs 4 and 5 will be averaged for a category 2 burn. II.D SUMMARY OF OTHER DATA TABLE 1. DATA SUMMARY PART A Category Run No. I 7 II 4,5 III 9 IV 2 Load % Capacity Θ W fuel MC ave Q in Q out Target Load Actual Load Actual Load Test Duration Wood Weight as-fired Wood Moisture Heat Input Heat Output Btu/hr Btu/hr % of Max hrs lb % DB Btu Btu <35% of max 12,622 9,332 26% 10.18 40.96 24.72 279,146 95,032 35-53% of max 15,867 15,521 43% 8.66 41.85 23.97 286,931 135,300 53-76% of max 27,407 25,236 70% 7.75 42.49 24.42 290,273 195,581 Max capacity 36063 36063 100% 5.93 41.59 24.48 284,455 194,522 TABLE 2. DATA SUMMARY PART B E T E E E g/hr η del ηslm Category Run No. I 7 II 4,5 III 9 IV 2 Load % Capacity Total PM Emissions PM Output Based Stack Loss Efficiency PM Output Based PM Rate Delivered Efficiency lb/mmbtu Out g/mj g/hr % % g <35% of max 6.35 0.147 0.06 0.62 34.0% 77.7% 35-53% of max 4.87 0.089 0.04 0.58 47.4% 79.9% 53-76% of max 8.21 0.093 0.04 1.06 67.4% 79.1% Max capacity 3.79 0.043 0.02 0.64 68.4% 79.0%

Project No. G102741836 Page 9 of 16 TABLE 3. WEIGHTED AVERAGE Run Weighting Input Output Category No. Factor η x F i E g/mj,i x F i CO g/min x F i E lb/mmbtu,i x F i E lb/mmbtu,i x F i E g/hr,i x F i I 7 0.250 0.085 0.016 0.295 0.013 0.037 0.156 II 4,5 0.250 0.118 0.010 0.214 0.009 0.022 0.145 III 9 0.250 0.168 0.010 0.016 0.016 0.023 0.265 IV 2 0.250 0.171 0.005 0.007 0.007 0.011 0.160 Totals 1.000 54.3% 0.040 0.822 0.045 0.093 0.726 TABLE 4. - GENERAL SUMMARY OF RESULTS 1 Burn Rate st Hour Run No. Emissions (kg/hr)(dry) (g/hr) Run Time (min) 7 1.463 1.9 611 4,5 1.776 1.05 519 9 1.999 2.6 465 2 2.558 1.3 356 TABLE 5. CSA B415.1 RESULTS Run No. CO Emissions Heating Efficiency Heat Output (g/hr) (% HHV) (Btu/hr) 7 70.75 77.7% 21,281 4,5 51.38 79.9% 26,557 9 74.70 79.1% 29,659 2 0.47 79.0% 37,914 III. PROCESS DESCRIPTION III.A TEST SET-UP DESCRIPTON A standard 6 diameter vertical single wall pipe and insulated chimney system was installed to 15 above floor level. The singe wall pipe extended to 8 feet above the floor and insulated chimney extended the remaining height. III.B AIR SUPPLY SYSTEM Combustion air enters a 2 x 6 inlet located on the side of the heater, which is directed to the firebox. All gases exit through the 6 flue also located at the top of the heater. The heater is natural draft.

Project No. G102741836 Page 10 of 16 III.C TEST FUEL PROPERTIES Wood used for the testing is split and seasoned oak cordwood. Oak has a default heating value of 8550 Btu/hr (19887 kj/kg) and a moisture content between 19% and 25% on a dry basis. IV. SAMPLING SYSTEMS IV.A. SAMPLING LOCATIONS Particulate samples are collected from the dilution tunnel at a point 20 feet from the tunnel entrance. The tunnel has two elbows and two mixing baffles in the system ahead of the sampling section. (See Figure 3.) The sampling section is a continuous 13 foot section of 6 inch diameter pipe straight over its entire length. Tunnel velocity pressure is determined by a standard Pitot tube located 60 inches from the beginning of the sampling section. The dry bulb thermocouple is located six inches downstream from the Pitot tube. Tunnel samplers are located 60 inches downstream of the Pitot tube and 36 inches upstream from the end of this section. (See Figure 1.) Stack gas samples are collected from the steel chimney section 8 feet ± 6 inches above the scale platform. (See Figure 2.)

Project No. G102741836 Page 11 of 16 IV.A.(1) DILUTION TUNNEL

Project No. G102741836 Page 12 of 16 IV.B. OPERATIONAL DRAWINGS IV.B.(1) STACK GAS SAMPLE TRAIN IV.B. OPERATIONAL DRAWINGS IV.B.(1). STACK GAS SAMPLE TRAI

Project No. G102741836 Page 13 of 16 IV.B.(2). DILUTION TUNNEL SAMPLE SYSTEMS Figure 3

Project No. G102741836 Page 14 of 16 V. SAMPLING METHODS V.A. PARTICULATE SAMPLING Particulates were sampled in strict accordance with ASTM E2515-2011. This method uses two identical sampling systems with Gelman A/E 61631 binder free, 47-mm diameter filters. The dryers used in the sample systems are filled with Drierite before each test run. In order to measure first-hour emissions rates the a third filter set is prepared at one hour into the test run, the filter sets are changed in one of the two sample trains. The two filter sets used for this train are analyzed individually to determine the first hour and total emissions rate. VI. QUALITY ASSURANCE VI.A. INSTRUMENT CALIBRATION VI.A. (1). DRY GAS METERS At the conclusion of each test program the dry gas meters are checked against our standard dry gas meter. Three runs are made on each dry gas meter used during the test program. The average calibration factors obtained are then compared with the six-month calibration factor and, if within 5%, the six-month factor is used to calculate standard volumes. Results of this calibration are contained in Appendix D. An integral part of the post test calibration procedure is a leak check of the pressure side by plugging the system exhaust and pressurizing the system to 10 W.C. The system is judged to be leak free if it retains the pressure for at least 10 minutes. The standard dry gas meter is calibrated every 6 months using a Spirometer designed by the EPA Emissions Measurement Branch. The process involves sampling the train operation for 1 cubic foot of volume. With readings made to.001 ft 3, the resolution is.1%, giving an accuracy higher than the ±2% required by the standard.

Project No. G102741836 Page 15 of 16 VI.A.(2). STACK SAMPLE ROTAMETER The stack sample rotometer is checked by running three tests at each flow rate used during the test program. The flow rate is checked by running the rotometer in series with one of the dry gas meters for 10 minutes with the rotometer at a constant setting. The dry gas meter volume measured is then corrected to standard temperature and pressure conditions. The flow rate determined is then used to calculate actual sampled volumes. VI.A.(3). GAS ANALYZERS The continuous analyzers are zeroed and spanned before each test with appropriate gases. A mid-scale multi-component calibration gas is then analyzed (values are recorded). At the conclusion of a test, the instruments are checked again with zero, span and calibration gases (values are recorded only). The drift in each meter is then calculated and must not exceed 5% of the scale used for the test. At the conclusion of each unit test program, a three-point calibration check is made. This calibration check must meet accuracy requirements of the applicable standards. Consistent deviations between analyzer readings and calibration gas concentrations are used to correct data before computer processing. Data is also corrected for interferences as prescribed by the instrument manufacturer s instructions. VI.B. TEST METHOD PROCEDURES VI.B.(1). LEAK CHECK PROCEDURES Before and after each test, each sample train is tested for leaks. Leakage rates are measured and must not exceed 0.02 CFM or 4% of the sampling rate. Leak checks are performed checking the entire sampling train, not just the dry gas meters. Pretest and post-test leak checks are conducted with a vacuum of 10 inches of mercury. Vacuum is monitored during each test and the highest vacuum reached is then used for the post test vacuum value. If leakage limits are not met, the test run is rejected. During, these tests the vacuum was typically less than 2 inches of mercury. Thus, leakage rates reported are expected to be much higher than actual leakage during the tests.

Project No. G102741836 Page 16 of 16 VI.B.(2). TUNNEL VELOCITY/FLOW MEASUREMENT The tunnel velocity is calculated from a center point Pitot tube signal multiplied by an adjustment factor. This factor is determined by a traverse of the tunnel as prescribed in EPA Method 1. Final tunnel velocities and flow rates are calculated from EPA Method 2, Equation 6.9 and 6.10. (Tunnel cross sectional area is the average from both lines of traverse.) Pitot tubes are cleaned before each test and leak checks are conducted after each test. VI.B.(3). PM SAMPLING PROPORTIONALITY Proportionality was calculated in accordance with ASTM E2515-11. The data and results are included in Appendix C. VII. CONCLUSION This test demonstrates that this unit is an affected facility under the definition given in the regulation. The emission rate of 0.093 lb/mmbtu meets the EPA requirements for the Step 2 limits based on the alternate test method created and approved by the U.S. EPA. The alternate test method allows the Lamppa Manufacturing model VF100 to be operated at output rates as specified in Clause 7.2 of CSA B415.1-2010 in order to comply with the Step 2 requirements of EPA 40 CFR Part 60 Standards of Performance for New Residential Wood Heaters, New Residential Hydronic Heaters and Forced-Air Furnaces, March 16, 2015. INTERTEK TESTING SERVICES NA Evaluated by: Ken Slater Associate Engineer - Hearth Reviewed by: Brian Ziegler Lead Engineer - Hearth