EN DK NA:2007

Similar documents
DS/EN DK NA:2010

DS/EN DK NA:2013

DS/EN DK NA:2013

CEN/TC 250- Published standards

DS/EN DK NA:2015

Advances on structural design with timber in Uruguay: Towards a proposal for a National Annex to Eurocode 5

DS/EN DK NA:2013

Eurocode 8 Timber and Masonry structures

Introduction to Eurocode 5

FAILURES OF TIMBER STRUCTURES IN SLOVENIA

The Edge Protection Federation Containment Systems Product Specification, Test Methods

Structural Design of Pergola with Airfoil Louvers

CLT Structural Design Sylvain Gagnon, Eng. February 8, 2011 Vancouver

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

BS EN :2004 EN :2004 (E)

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

BROADSPAN. LVL Design Brochure. Design properties for LVL header and beam applications in the U.S. for residential floor and roof systems

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

SECTION PLATE CONNECTED WOOD TRUSSES

PC Beam Shoe. Corbel system to support beams. Technical Manual. Version: DK 4/2012 Design standard: DS EN Eurocodes + NA (Denmark)

IZODOM 2000 POLSKA Zduńska Wola, ul. Ceramiczna 2. tel , , tel./fax

Lintels and Beams Engineering basis

Lintels and Beams: Engineering Basis

TECHNICAL MANUAL. PETRA Slab Hanger. Hollow-Core Support for Slab Openings

CH. 9 WOOD CONSTRUCTION

Scientific Seminar Design of Steel and Timber Structures SPbU, May 21, 2015

INSTALLATION. General. Important Note. Design. Transport

LPI 56 Technical Guide

Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures

Metal Web Floor System

Eurocodes European Codes for Structural Design. H. J. Bossenmayer, Prof. Dr.-Ing., is president, Deutsches Institut für Bautechnik, Berlin, Germany

European Technical Assessment. ETA-18/0083 of Member of. General part

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

ThermaSteel Corporation ASSEMBLY MANUAL

WOOD I-JOIST AWARENESS GUIDE

FasteningSystems Rosenbergsaustraße HEERBRUGG SCHWEIZ EAD This version replaces ETA-13/0699 issued on 13 June 2013

Garage/Accessory Structures

Principles of STRUCTURAL DESIGN. Wood, Steel, and Concrete SECOND EDITION RAM S. GUPTA. CRC Press. Taylor& Francis Group

TC 250 Structure. SC/WG for Existing Eurocodes SC4.EG1.1 SC4.EG1.2 SC4.EG2

Renovation of Buildings using Steel Technologies (ROBUST)

European Technical Assessment ETA-10/0422 of 08/01/2016

Structural Calculations for standard BALCONY 1 system handrail using 55mm diameter posts (48.3mm x 5mm CHS) & 150 x 150 x 15mm base plates

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels ( )

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

SPECIFICATION FOR PRECAST/ COMPOSITE CONCRETE FLOORS/ ROOF DECKS SECTION E60

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

COLUMN SHOES HPKM, PPKM, PEC

Schöck Isokorb type K

European Technical Assessment. ETA-15/0540 of Member of. General part

Product overview:

Design of Steel-Concrete Composite Bridges

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

LIMIT STATES DESIGN INFORMATION for Specific Engineering Design for New Zealand Construction

WP6 Case studies. The object is founded on drilled piles on which foundation girders connected by transverse reinforcedconcrete

Schöck Isokorb type KS

DESIGN OF HIGH-RISE MODULAR OPEN BUILDINGS

Level 6 Graduate Diploma in Engineering Structural analysis

Eurocode 5: Design of timber structures

X-Lam Designer for Derix Cross Laminated Timber. User manual. X-Lam Designer. User manual. Version 6.0. Page 1

A-BEAM S Erection Manual 2

HOLDOWN & STRAP SCHEDULE

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

SHOT FIRED DOWEL FLITCH BEAMS

timber; structure; large span roof; failure; robustness; redundancy; indeterminacy

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT:

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

Stone and Masonry Veneer

European Technical Assessment ETA-10/0067 of

Installing DELTABEAM. Installation of DELTABEAM. Deliveries. Storage on-site

OUR COMPANY OUR WARRANTY OUR GUARANTEE

DEUTSCHES INSTITUT FÜR BAUTECHNIK Anstalt des öffentlichen Rechts

EVERLAST KWILA/MERBAU GL17S ENGINEERED MAGNA BEAMS & KWILA/MERBAU GL13 ENGINEERED MAGNA POSTS

Design Methods of Elements from Cross-Laminated Timber Subjected to Flexure

Acknowledgments. Abstract

3.4.2 DESIGN CONSIDERATIONS

Minimum required percentage of length of braced wall band on each storey 4

ELEMENTS OF EUROPEAN NORMATIVE IN THE DESIGN OF STRUCTURES AND THEIR APPLICATION IN ALBANIA

SECTION METAL PLATE CONNECTED WOOD TRUSSES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

DESIGN OF WALLS FOR SHEAR

Inverse reliability applications and performance-based design in timber engineering

European Technical Assessment ETA-14/0354 of

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

European Technical ETA 06/0238 Assessment of 31/08/2017

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

SINTEF Building and Infrastructure confirms that. Hunton Undertak / Hunton Sarket

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Acknowledgments. Abstract

one structural behavior, systems, and design ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2015 lecture

MANDATE TO CEN/CENELEC CONCERNING THE EXECUTION OF STANDARDISATION WORK FOR HARMONIZED STANDARDS ON. STRUCTURAL TIMBER PRODUCTS and ancillaries

Structural safety and rehabilitation of connections in wide-span timber structures - two exemplary truss systems

Fundamentals of Structural Design Part of Steel Structures

ADVANCED NONLINEAR INVESTIGATIONS OF A 50 M SPAN FRAME CASE STUDY: THE STEEL STRUCTURE OF THE ICE RINK, CITY OF TARGU-MURES, ROMANIA

Conergy SolarFamulus II

Transcription:

EN 1995-1-1 DK NA:2007 National Annex to Eurocode 5: Design of timber structures - Part 1-1: General - Common rules and rules for buildings Foreword In connection with the incorporation of Eurocodes into Danish building legislation to replace the Danish structural codes of practice, this National Annex was prepared in 2006-2007 to implement Eurocode 5 in Denmark. Scope This National Annex lays down the conditions for the implementation of the Eurocode. Contents This National Annex specifies the national choices prescribed in Denmark. The national choices may be in the form of nationally applicable values, an option between methods given in the Eurocode, or the addition of supplementary guidance. This National Annex addresses: Clauses where national choices have been made; All clauses where national choices have been possible; Bibliography: Overview of all National Annexes prepared. Page 1 of 10

Clauses where national choices have been made 2.3.1.2(2)P Assignment of loads to load-duration classes Examples of assignment of loads to load-duration classes in Denmark appear from Table 2.2. Table 2.2 Examples of determination of load-duration classes Load-duration class Permanent Long-term Medium-term Short-term Instantaneous Examples of loads self-weight silo action storage areas, Category E, see DS/EN 1990 - other variable actions - snow loads - variable loads on concrete forms - variable loads on scaffolding and transient structures - short-term forces due to temperature and moisture actions - accidental load - wind actions - impact forces, including impact allowance - random person load (concentrated load) on roofs and similar loads - mooring forces from ships - short-term action on quays - braking and acceleration forces - wave and ice pressures. Page 2 of 10

2.3.1.3(1)P Assignment of structures to service classes Examples of structures assigned to the service classes indicated in (2)P, (3)P and (4)P: Service class 1 - structures in heated buildings where moisture is not added to the air, e.g. dwellings, offices and shops. Service class 2 - structures in ventilated, not permanently heated buildings, e.g. weekend cottages, unheated garages and storehouses; - ventilated structures protected against precipitation, e.g. ventilated roof structures. Service class 3 - structures in moist rooms; - structures exposed to precipitation or water, including concrete forms and outdoor scaffolding; - timber frames for felted roofs if these are not designed in such a way that they may be assigned to Service class 2. 2.4.1(1)P Partial factors for material properties γ M Instead of Table 2.3 in EN 1995-1-1, the following shall be used: Ultimate limit states (1)P The following partial factors for shall be used for ultimate limit states for persistent and transient design situations. Structures (IN SITU) Glued laminated timber, LVL and panels γ M = 1,30γ 3 Solid timber γ M = 1,35γ 3 Connections, e.g. with dowel type fasteners γ M = 1,35γ 3 Connections, e.g. with glued bolts and splice connections γ M = 1,50γ 3 Connections made with punched metal plate fasteners γ M = 1,35γ 3 The partial factors are determined in accordance with the DK National Annex to EN 1990, Annex F, where γ M = γ 1 γ 2 γ 3 γ 4. γ 1 γ 2 γ 3 γ 4 takes into account the type of failure takes into account the uncertainty related to the design model takes into account the extent of inspection takes into account the variation of the strength parameter or resistance. When determining γ 1 the following type of failure should be applied: Page 3 of 10

Assumed types of failure for the determination of γ 1 Structures Glued laminated timber, LVL and panels Solid timber Connections, e.g. with dowel type fasteners Connections, e.g. with glued bolts and splice connections Connections made with punched metal plate fasteners Warning of failure without spare resistance Warning of failure without spare resistance Warning of failure without spare resistance No warning Warning of failure without spare resistance (2) The following values of γ 3, depending on the level of inspection, should be used. Sub-partial factor γ 3 depending on the level of inspection Inspection Tightened Normal Relaxed level γ 3 0,95 1,0 1,10 Factory-made elements such as structural timber elements and prefabricated timber members made with punched metal plate fasteners may be assigned to the tightened inspection level. Other elements should be assigned to the normal inspection level. (3)P The following partial factors shall be used in Denmark for ultimate limit states for accidental design situations γ M = 1,0. 6.4.3(8) Double tapered, curved and pitched cambered beams Expression (6.55) should be applied, using the following definition: p d is the uniformly distributed load acting on the top of the beam at the ridge in the direction of the beam axis. If the uniformly distributed load acts away from the beam axis??, the last term of expression (6.55) changes its sign. 7.2(2) Limiting values for deflections Instead of Table 7.2 of EN 1995-1-1, the limiting values for deflections specified in the table below should be used. Page 4 of 10

Table 7.2 - Limitation of deflections Structure Load w inst w net,fin Where limitation of the deflection of structures is necessary, the following frequently used deflections may be used as a basis. Structures in roofs or over small buildings Roof trusses Large glued laminated timber structures in roofs and their supports With camber Large glued laminated timber structures in roofs and their supports Without camber Snow loads 0,72 kn/m 2 l/400 - Self weight l/400 - Characteristic snow loads l/500 - Wind l/250 - Self weight l/400 - Self weight and imposed l/200 0 load Self weight and imposed load l/300 - The deflection of the structures mentioned below should not exceed the values stated. Floor structures in multistorey buildings Floor joints of residential buildings, e.g. single family hourse Concentrated load 1,0 kn 1,7 mm - 1,5 kn/m 2 l/600-7.3.3(2) Limiting values for vibrations The maximum ratio between w and F, where w is the instantaneous vertical deflection due to a vertical concentrated static force F applied anywhere on the floor should fulfil w a mm/kn F (0.1) and the unit impulse velocity v should fulfil ( f -1) 1 v b ζ m/(ns²) (0.2) where: a = 4 mm/kn b= 50 m/(ns 2 ) Page 5 of 10

8.3.1.2(4) Nailed timber-to-timber connections: Rules for nails in end grain The paragraph should be replaced by: Smooth nails in end grain should not be assumed to have any lateral load-bearing capacity. For annular ringed nails according to EN 14592 in end grain, the lateral load-bearing capacity should be taken as 1/3 of the capacity specified for annular ringed nails driven in perpendicular to the grain, provided that: the nailed connection is subject to lateral action only; at least 3 annular ringed nails are used; the applicable requirements for minimum thicknesses, edge distances and minimum distances of nailed connections are fulfilled; the nail point penetration in the end grain is at least 10d; the connection can be assigned to service class 1 or service class 2. 8.3.1.2(7) Nailed timber-to-timber connections: Species sensitive to splitting Addition: For timber with a moisture content less than 10% at the time of erection, the recommendation in EN 1995-1-1 should be observed. Predrilling may be omitted in timber with a moisture content exceeding 10% and for nails with a diameter smaller than 5 mm or a side length smaller than 3,5 mm. 9.2.5.3(1) Bracing modification factors for beam or truss The following Danish modification factor values in Table 9.2 for the determination of stiffness and resistance of stabilising structures are recommended: Table 9.2 Factor Value s ky 3,0 k f,1 80 k f,2 100 k f,3 60 The following should furthermore be added: Where at least 8 equal, closely spaced solid timber members in compression are supported by closely spaced transverse bracings, e.g. braced by battens, half of the bending stiffness and the bending strength of the timber members may be used to resist and transfer a d. For less than 8 members, n/16 of the bending stiffness and the bending strength should be used. Page 6 of 10

The accumulated force in the transverse bracing member supporting n members in compression should at least be taken as: F akku = nf d - but no more than 3F d. where F ad. is the design stabilising force according to 9.2.5.2(3). 10.9.2(3) Erection of trusses with punched metal plate fasteners: maximum bow Maximum bow = +/- l /500, but no more than +/- 45 mm from the symmetry plane. See Figure 10.9.2 where l is the span of the truss. 10.9.2(4) Erection of trusses with punched metal plate fasteners: maximum vertical deviation Maximum deviation from the vertical symmetry plane +/- 45 mm, but no more than +/- h/100 measured locally on the truss. See Figure 10.9.2 where h is the truss height. Max. bow length l Max. deviation from vertical plane height h Figure 10.9.2 - Maximum bow and deviation from vertical alignment Page 7 of 10

Overview of possible national choices The list below identifies the clauses where national choices are possible and the applicable/not applicable informative annexes. Furthermore, this National Annex refers to additional (non-conflicting) information that may be of assistance to the user of the Eurocode. National choice Clause 2.3.1.2(2)P 2.3.1.2(1)P 2.4.1(1)P Comment National assignment National assignment National partial factors 6.4.3(8) Guidance 7.2(2) Guidance 7.3.3(2) Guidance 8.3.1.2(4) Danish rules for nails in end grain 8.3.1.2(7) Addition 9.2.4.1(7) No changes 9.2.5.3(1) National values 10.9.2(3) Recommended Danish practice 10.9.2(4) Recommended Danish practice Annex A Annex B Annex C Annex D Applicable Applicable Applicable Applicable Page 8 of 10

Additional (non-conflicting) information 9.2.2 (4) Minimum overlap of punched metal plate fasteners Where a punched metal plate fastener utilises no more than 80% of its load-bearing capacity, the requirement for minimum overlap of one third of the height of the timber member may be disregarded. It should be verified that the timber is not subject to splitting. NOTE - This guidance is based on the Danish requirements for increased insulation thicknesses and the associated increased timber dimensions. Page 9 of 10

Bibliography List of all National Annexes EN 1990 DK NA:2007 National Annex to Eurocode 0 Basis of structural design EN 1991-1-1 DK NA:2007 National Annex to Eurocode 1: Actions on structures Part 1-1: General actions Densities, selfweight, imposed loads for buildings EN 1991-1-2 DK NA:2007 National Annex to Eurocode 1: Actions on structures Part 1-2: General actions Actions on structures exposed to fire EN 1991-1-3 DK NA:2007 National Annex to Eurocode 1: Actions on structures Part 1-3: General actions Snow loads EN 1991-1-4 DK NA:2007 National Annex to Eurocode 1: Actions on structures Part 1-4: General actions Wind actions EN 1991-1-5 DK NA:2007 National Annex to Eurocode 1: Actions on structures Part 1-5: General actions Thermal actions EN 1991-1-6 DK NA:2007 National Annex to Eurocode 1: Actions on structures Part 1-6: General actions Actions during execution EN 1991-1-7 DK NA:2007 National Annex to Eurocode 1: Actions on structures Part 1-7: General actions Accidental actions EN 1992-1-1 DK NA:2007 National Annex to Eurocode 2: Design of concrete structures - Part 1-1: General rules and rules for buildings EN 1992-1-2 DK NA:2007 National Annex to Eurocode 2: Design of concrete structures - Part 1-2: General rules Structural fire design EN 1993-1-1 DK NA:2007 National Annex to Eurocode 3: Design of steel structures - Part 1-1: General rules and rules for buildings EN 1993-1-2 DK NA:2007 National Annex to Eurocode 3: Design of steel structures - Part 1-2: General rules Structural fire design EN 1993-1-3 DK NA:2007 National Annex to Eurocode 3: Design of steel structures - Part 1-3: General rules - Supplementary rules for cold-formed members and sheeting EN 1993-1-4 DK NA:2007 National Annex to Eurocode 3: Design of steel structures - Part 1-4: General rules - Supplementary rules for stainless steels EN 1993-1-5 DK NA:2007 National Annex to Eurocode 3: Design of steel structures - Part 1-5: Plated structural elements EN 1993-1-6 DK NA:2007 National Annex to Eurocode 3: Design of steel structures - Part 1-6: Strength and stability of shell structures EN 1993-1-7 DK NA:2007 National Annex to Eurocode 3: Design of steel structures - Part 1-7: Plated structures subject to out of plane loading EN 1993-1-8 DK NA:2007 National Annex to Eurocode 3: Design of steel structures - Part 1-8: Joints EN 1993-1-9 DK NA:2007 National Annex to Eurocode 3: Design of steel structures Part 1-9: Fatigue EN 1993-1-10 DK NA:2007 National Annex to Eurocode 3: Design of steel structures - Part 1-10: Material toughness and throughthickness properties EN 1994-1-1 DK NA:2007 National Annex to Eurocode 4: Design of composite steel and concrete structures - Part 1-1: General rules and rules for buildings EN 1994-1-2 DK NA:2007 National Annex to Eurocode 4: Design of composite steel and concrete structures - Part 1-2: General rules Structural fire design EN 1995-1-1 DK NA:2007 National Annex to Eurocode 5: Design of timber structures - Part 1-1: General - Common rules and rules for buildings EN 1995-1-2 DK NA:2007 National Annex to Eurocode 5: Design of timber structures - Part 1-2: General Structural fire design EN 1996-1-1 DK NA:2007 National Annex to Eurocode 6: Design of masonry structures - Part 1-1: General rules for reinforced and unreinforced masonry structures EN 1996-1-2 DK NA:2007 National Annex to Eurocode 6: Design of masonry structures - Part 1-2: General rules Structural fire design EN 1996-2 DK NA:2007 National Annex to Eurocode 6: Design of masonry structures - Part 2: Design considerations, selection of materials and execution of masonry EN 1997-1 DK NA:2007 National Annex to Eurocode 7: Geotechnical design - Part 1: General rules EN 1999-1-1 DK NA:2007 National Annex to Eurocode 9: Design of aluminium structures - Part 1-1: General rules EN 1999-1-2 DK NA:2007 National Annex to Eurocode 9: Design of aluminium structures Part 1-2: Structural fire design EN 1999-1-3 DK NA:2007 National Annex to Eurocode 9: Design of aluminium structures Part 1-3: Fatigue Page 10 of 10