Product Classification. Standards And Qualifications. Representative Image. General Specifications. Construction Materials

Similar documents
Representative Image. General Specifications. Construction Materials. Dimensions. Physical Specifications

Z-002-IC-5L-F29BK

Product Classification. Standards And Qualifications. Representative Image. General Specifications. Construction Materials.

Z-006-DN-5L-F06BK/D

LazrSPEED 150 MPO (male) to MTRJ, ReadyPATCH Ruggedized Fanout, 36-Fiber, Plenum

P-012-DZ-8W-FSUYL

LazrSPEED 150 LC Uniboot to MTRJ, ReadyPATCH Ruggedized Fanout, 36-Fiber, Plenum

Product Classification. Standards And Qualifications. Representative Image. General Specifications. Construction Materials.

PFC-304L12F. Product Classification. Standards And Qualifications. General Specifications. Construction Materials. Dimensions. Physical Specifications

Product Classification. Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications

/DB O-002-DF-HY-F02NS/8W002/1X24AWG

Construction Materials. Dimensions. Environmental Specifications. General Specifications. Regulatory Compliance/Certifications.

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

Detailed Specifications & Technical Data

Fiber Optic Cables. General cable specification

Detailed Specifications & Technical Data

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable

Datasheet. EFB Elektronik GmbH. O Breakoutcable ST/ST 2G 62,5/125µ, 1 M. Nettogewicht 1,00. 52,60 Länge. Katalogseite

CLEERLINE OPTICAL FIBER

CenturyLink Quick Reference Guide

Detailed Specifications & Technical Data

Broadband Communications

Amphenol Spectra-Strip

SE-8** PureAccess Single-Mode Fiber

Product overview. Product characteristics. Article number Cables - Universal Print Date

Outdoor. Broadband Communications standard. 1. Cable Construction

OPTICAL FIBRES. MULTIMODE Multimode Optical Fibres 50/125 Multimode Optical Fibres 62,5/125. SINGLEMODE Singlemode Optical Fibre

Specifications of. Single Armored Optical Fiber Cable

3M Optical Fiber Cable Specification

TECHNICAL SPECIFICATION ALANTEK OPTICAL FIBER FTTH DROP CABLE

TECHNICAL SPECIFICATION ALANTEK OPTICAL FIBER FIG8 SERIES FTTH DROP CABLE

PERFORMANCE SPECIFICATION SHEET FIBER, OPTICAL, TYPE I, CLASS I, COMPOSITION A, SIZE III, WAVELENGTH B, RADIATION RESISTANT (METRIC)

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

Generic Requirements for Optical Fiber and Optical Fiber Cable

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET CABLE, FIBER OPTIC, SINGLE (ONE) FIBER, CABLE CONFIGURATION TYPE 2 (OFCC), TIGHT BUFFER, CABLE CLASS SM AND MM

MIL-PRF-49291/6C 10 January 2003 SUPERSEDING MIL-F-49291/6B 29 November 1994

PERFORMANCE SPECIFICATION SHEET

Specialty Multimode Graded-Index Fiber

Corning RC Specialty Fibers Reduced Cladding Fibers Enable Miniaturization and Device Integration

PERFORMANCE SPECIFICATION SHEET FIBER, OPTICAL, TYPE II, CLASS 5, SIZE II, COMPOSITION A, WAVELENGTH D, RADIATION RESISTANT

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

OPTICAL FIBER SOLUTIONS

SOFC-DA-180KN-192 G652D

Downloaded from

PERFORMANCE SPECIFICATION SHEET

GMRT. Mini-Breakout Cables (Distribution) Mobile, Tactical Indoor/ Outdoor, Heavy Duty A/I-VQ(ZN)11Y(ZN)11Y Improved Rodent Protection

TECHNICAL SPECIFICATION FOR AND 72 CORE CONDUIT OPTICAL FIBER CABLES

PERFORMANCE SPECIFICATION SHEET

FTTH Fiber Optical Cable

Industrial Harsh Environment Fiber Cables

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

Reliability test report for SR15-9/125-ACL (SM Fiber with high temperature resistant acrylate coating)

Producing Oil and Gas

InstaPATCH Plus Fiber System

PERFORMANCE SPECIFICATION SHEET

Mode Field Diameter R37003 R37003X R37003X R R37004 R HP980X

Fiber Cable Construction

OPTICAL FIBRE CABLE PERFORMANCE

105 Micron Core Power Delivery Fibers

SPECIAL SPECIFICATION 1663 Fiber Optic Cable

AS... UV FIBERS AS... IR FIBERS GRADED INDEX FIBERS PCS - FIBERS HPCS - FIBERS SINGLE-MODE FIBERS CAPILLARIES

ARINC 801 Fiber Optic Connectors

PERFORMANCE SPECIFICATION SHEET

SPECIFYING FIBER OPTIC CABLE

Technical Specifications for 24fiber/48fiber armoured Underground Optical Fiber Cable

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

fiberguide Hard Clad Silica (Low OH) Fiberguide Industries Technical Data Anhydroguide APCH

OPTICAL FIBER, CABLE, ASSEMBLIES. ISO 9001 and Certified. FDA Good Manufacturing Practices. USP Class VI and ISO10993 for Biocompatibility

Hard Coated Silica/Silica (Low OH) Radius

UniCam Multimode Standard-Performance Connectors: SC and ST Compatible

Fujikura PANDA fiber products and Basics of PM fibers

Downloaded from PERFORMANCE SPECIFICATION FIBER, OPTICAL, (METRIC) GENERAL SPECIFICATION FOR

Standard fiber offering.

Coating geometry parameters of silica optical fiber - An Appraisal

Optical Gateway Interface (OGI) Connector System Qualification Test Result Summary Telcordia GR 1435 CORE

ADC Structured Cabling Solutions TracerLight Connector Identification System

fiber optic cables fibrain

13-SDMS-04 REV. 00 SPECIFICATIONS FOR NON-METALLIC, LOOSE TUBE, DUCT & BLOWN TYPE FIBER OPTIC CABLE

SECTION BACKBONE CABLING SPECIAL NOTE: (REMOVE FROM FINAL DOCUMENTATION)

Zipcord 2.2mm Plastic Optical Fiber Cable Specifications. Fiber types Core Polymethyl Methacryate(PMMA) Pluorinated Polymer

Plastic Coated Silica/Silica (Low OH) FIBER CROSS SECTION Polyimide and Acrylate Coated. Nylon and Tefzel Coated

Article number: Sheath marking ACE - TKF LTC-S RP 24x SM G.657.A1 6x4 A-DQ(ZN)B2Y {Batch} {Year} {Length}

CLEERLINE TECHNOLOGY GROUP

Material will comply with those standards as established by UL or NEMA and shall be commercial grade. All materials will be new and free from defects.

Plastic Coated Silica/Silica (Standard OH) Nylon and Tefzel Coated

Best Construction Practices and Splicing for Fiber Networks

Electric cables. CRANES APPENDIX

ADSS FIBER OPTIC CABLE

Fiber Optic Cables. The Quality Connection

Fiber Optic Cables. The Quality Connection

SCOPE OF WORK OF SINGLE MODE OPTICAL FIBER CABLES (12 FIBERS)

Introduction. Quality Management Approach

Kenya Power and Lighting Company VI Contract A31

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

Fiber Bragg Gratings. Research, Design, Fabrication, and Volume Production. All capabilities within one company

Technical Specification for Single Core 19/33kV Copper / TR-XLPE Underground Cable

Single-Mode Fiber. Supersedes: --/-- 05/08. ColorLock-XS. Draka Fiber Coating. Application Note

Transcription:

LazrSPEED Plenum Distribution Cable, 6 fiber single-unit Product Classification Portfolio CommScope Product Type Fiber indoor cable Regional Availability Asia Australia/New Zealand EMEA Latin America North America Standards And Qualifications Cable Qualification Standards ANSI/ICEA S-83-596 Telcordia GR-409 Representative Image General Specifications Cable Type Construction Type Subunit Type Distribution Non-armored Gel-free Construction Materials Fiber Type Solution LazrSPEED 300, 50 µm multimode fiber (OM3) Total Fiber Count 6 Fiber Type LazrSPEED 300, 50 µm multimode fiber (OM3) Fiber Type, quantity 6 Jacket Color Aqua page 1 of 5

Dimensions Cable Weight 14.8 lb/kft 22.0 kg/km Diameter Over Jacket 4.74 mm 0.19 in Physical Specifications Minimum Bend Radius, loaded 7.1 cm 2.8 in Minimum Bend Radius, unloaded 4.7 cm 1.9 in Tensile Load, long term, maximum 45 lbf 200 N Tensile Load, short term, maximum 150 lbf 667 N Vertical Rise, maximum 500.0 m 1640.4 ft Flame Test Specifications Flame Test Listing NEC OFNP (ETL) and c(etl) Flame Test Method NFPA 262 Environmental Specifications Environmental Space Installation Temperature Operating Temperature Storage Temperature Plenum 0 C to +70 C (+32 F to +158 F) -40 C to +70 C (-40 F to +158 F) Mechanical Test Specifications Compression 10 N/mm 57 lb/in Compression Test Method FOTP-41 IEC 60794-1 E3 Flex 100 cycles Flex Test Method FOTP-104 IEC 60794-1 E6 Impact 4.34 ft lb 5.88 N-m Impact Test Method FOTP-25 IEC 60794-1 E4 Strain See long and short term tensile loads Strain Test Method FOTP-33 IEC 60794-1 E1 Twist 10 cycles Twist Test Method FOTP-85 IEC 60794-1 E7 Environmental Test Specifications Heat Age -20 C to +85 C (-4 F to +185 F) Heat Age Test Method IEC 60794-1 F9 Low High Bend Low High Bend Test Method FOTP-37 IEC 60794-1 E11 Temperature Cycle Temperature Cycle Test Method FOTP-3 IEC 60794-1 F1 Regulatory Compliance/Certifications Agency Classification RoHS 2011/65/EU Compliant ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system page 2 of 5

Included Products CS-5L-TB (Product Component not orderable) LazrSPEED 300 OM3 Bend-Insensitive Multimode Fiber * Footnotes Operating Temperature Specification applicable to non-terminated bulk fiber cable page 3 of 5

CS-5L-TB LazrSPEED 300 OM3 Bend-Insensitive Multimode Fiber Product Classification Portfolio Product Type CommScope Optical fiber Regional Availability Asia Australia/New Zealand EMEA Latin America North America Optical Specifications, Wavelength Specific Standards Compliance Attenuation, maximum Differential Mode Delay Note Index of Refraction TIA-492AAAC (OM3) 1.00 db/km @ 1300 nm 3.00 db/km @ 850 nm Superior to TIA-492AAAC and IEC 60793-2-10 at 850 nm 1.479 @ 1300 nm 1.483 @ 850 nm 1 Gbps Ethernet Distance 600 m @ 1300 nm 1020 m @ 850 nm 10 Gbps Ethernet Distance 300 m @ 850 nm 984 ft @ 850 nm Bandwidth, Laser, minimum Bandwidth, OFL, minimum Differential Mode Delay Backscatter Coefficient 500 MHz-km @ 1300 nm 2000 MHz-km @ 850 nm 500 MHz-km @ 1300 nm 1500 MHz-km @ 850 nm 0.70 ps/m @ 850 nm 0.88 ps/m @ 1300 nm -75.7 db @ 1300 nm -68.0 db @ 850 nm Physical Specifications Cladding Diameter 125.0 µm Cladding Diameter Tolerance ±1.0 µm Cladding Non-Circularity, maximum 1.0 % Coating Diameter (Colored) 254 µm Coating Diameter (Uncolored) 245 µm Coating Diameter Tolerance (Colored) ±7 µm Coating Diameter Tolerance (Uncolored) ±10 µm Tight Buffer Diameter 900 µm Tight Buffer Diameter Tolerance ±40 µm Coating/Cladding Concentricity Error, maximum 12 µm Core Diameter 50.0 µm Core Diameter Tolerance ±2.5 µm Core/Clad Offset, maximum 1.5 µm Optical Specifications, General Numerical Aperture 0.200 page 4 of 5

CS-5L-TB CS-5L-TB Numerical Aperture Tolerance ±0.015 Point Defects, maximum 0.15 db Zero Dispersion Slope, maximum 0.105 ps/[km-nm-nm] Zero Dispersion Wavelength, maximum 1316 nm Zero Dispersion Wavelength, minimum 1297 nm Mechanical Specifications Coating Strip Force, maximum 8.9 N 2.0 lbf Coating Strip Force, minimum 1.3 N 0.3 lbf Dynamic Fatigue Parameter, minimum 18 Macrobending, 15 mm mandrel, 2 turns Macrobending, 30 mm mandrel, 2 turns Macrobending, 75 mm mandrel, 100 turns 0.20 db @ 850 nm 0.50 db @ 1300 nm 0.10 db @ 850 nm 0.30 db @ 1300 nm 0.50 db @ 850 nm 0.50 db @ 1300 nm Proof Test 689.48 N/mm² 100000.00 psi Environmental Specifications Heat Aging, maximum 0.20 db/km @ 85 C Temperature Dependence, maximum 0.10 db/km Temperature Humidity Cycling, maximum 0.20 db/km Water Immersion, maximum 0.20 db/km @ 23 C Regulatory Compliance/Certifications Agency Classification ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system * Footnotes Temperature Dependence, maximum Temperature dependence is conducted at -60 C to +85 C (-76 F to +185 F) Temperature Humidity Cycling, maximum Temperature humidity cycling is conducted at -10 C to +85 C (+14 F to +185 F) up to 95% relative humidity page 5 of 5