AKUSTIK + AMC Mecanocaucho & AKUSTIK+ AKUSTIK+ AMC Mecanocaucho SOPORTES DE TECHO. Akustik+ When 2 db at low frequencies make the difference

Similar documents
NOISE REDUCTION MOUNTS

AKUSTIK +

Akustik+ When 2 db at low frequencies make the difference AMC // AKUSTIK & AKUSTIK+

AKUSTIK + AKUSTIK +

SAHLBERG. Resilient Mountings with KSD. Technical Manual. 100 years of intelligent solutions

Test report No B0082 IN CM 26-M56-I

Test report No B0082 IN CM 26-M55-I

The insulators are available in the standard colours green (40Sh-A), red (55Sh-A), and beige (70Sh-A).

ARH-1. Hung ceilings, because of the TRANSMITTED NOISE & VIBRATION BARRIER FOR SUSPENDED CEILINGS, DUCTWORK, CONDUIT, PIPING, ETC.

ROSTA Anti-vibration Mountings

The new solution for air handling units. Resilient Mountings with KSD Compact. Viessmann Lagerartikelkatalog Stand Juli 2012 (mit Preisen)

PT Mount. Multi-purpose Application & Economical. Multi-purpose Application at Low Cost. Round Type Vibration-proof Rubber. Example for Installation

Since there is not a standard procedure to carry out this type of test, the next methodology was followed:

POWER PRESSES. Vibration Control, Mounting and Levelling of: Power Presses APPLICATIONS. Presses come in various categories including:

ELASTICALLY SEPARATED FLOOR

TVS Acoustic Treatments. for Cinemas & Bowling Alleys

SILENTFLEX FLOATING SLAB

matteco CONSTRUCTION sound insulation products

CATALOG VIBRATION ISOLATORS CIRCULAR CUSHYFOOT CUP MOUNT SANDWICH MOUNTS BOBBINS & BUFFERS

SOUND INVESTMENT How the Acoustical Properties of Building Products Are Measured and Why This Is Important

Vibration Control SCHWINGMETALL. The Original Rubber-To-Metal Bonding from ContiTech

Comparative Impact Performances of Lightweight Gym Floors

Vibration Isolation of Machine Foundations

HIGH PERFORMANCE ACOUSTIC INSULATING MATERIAL FOR A QUIETER ENVIRONMENT

Stage 3 Noise and vibration analysis NOISE

Vibratec Akustikprodukter AB Civil Engineering

On the use of scaled models in building acoustics

SOLUTIONS FOR TIMBER STRUCTURES ACOUSTIC INSULATION

SECTION VIBRATION ISOLATION

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007 A METHODOLOGY TO MEASURE THE ACOUSTIC PERFORMANCE OF ACCESS FLOORS

Experimental measurements of flanking transmission in CLT structures

BARRY-BOND MOUNTS. Features. Benefits. Load Range

Research of transmission loss properties of thin layered sound reduction systems for building partition elements

Machine / Equipment Isolation REGUPOL-ACOUSTICS.COM

RIVER PUMP ROOM ISOLATION FROM STATE LIBRARY. David Borgeaud 1 and Michael Plumb 2. Brisbane, QLD 4000, Australia 2 GP Embelton & Co.

SECTION VIBRATION AND SEISMIC CONTROL FOR PLUMBING

Specialist Study on Noise APPENDIX 4 : EXAMPLES OF GOOD OPERATING PRACTICES IN ORDER TO REDUCE NOISE EMISSIONS

Measurement series to verify the accuracy of Stora Enso Acoustic Prediction tool - SEAP

ACOUSTICAL TREATMENT OF EMERGENCY POWER GENERATOR. Dr. M.Abd El Gawad Saif

TVS Acoustic Flooring Range

Vibration Isolation of Machine Foundations. Active and Passive Isolation

SoundPro CDM-ISO-LAT. Acoustic solution for floating isolated floors

Sound Insulation for Glass and Panel

Ozone Panel 120 Acoustic Assessment and Optimization

MEFA spring hanger meet the requirements of vibration insulation and disconnection of structure-borne-sound.

LEWIS Dovetailed sheeting. Dovetailed Sheeting

Chapter 5 Airborne sound insulation

ACOUSTIC INSULATION UNDER SCREED made from recycled rubber granules

Building Isolation Design for Noise Critical Applications

VIBRATION TRANSMISSIBILITY CURVE FOR AN ISOLATED SYSTEM

K-FLEX. Acoustic Insulation. solutions for acoustic comfort

2 FIGURE -1

O c t o b e r K-FLEX. Acoustic Insulation

The effect of additional thermal lining on the acoustic performance of a wall

KEY FACTORS OF A SHIP INTERNAL NOISE PREDICTION PROCEDURE

LABORATORY MEASUREMENT OF AIRBORNE SOUND INSULATION OF PIR ROOF PANELS (According to ISO )

Introduction to Acoustics

ADDENDUM #2. Questions Asked and Answers Provided: Question #2: Please provide the expected turnaround time of the one engine being overhauled.

Hush Uk - Roofing. Tel: Fax:

LABORATORY MEASUREMENT OF AIRBORNE SOUND INSULATION OF STEEL CLAD PIR WALL PANELS (According to ISO )

ISO INTERNATIONAL STANDARD

DIVISION 20 GENERAL SECTIONS FOR PLUMBING, FIRE SUPPRESSION & HVAC SECTION VIBRATION ISOLATORS

CATALOG VIBRATION ISOLATORS CIRCULAR CUSHYFOOT CUP MOUNT SANDWICH MOUNTS BOBBINS & BUFFERS

Control of variable frequency vibration in large span composite construction floor in a high rise building

Soundproofing of Wood-frame buildings

Sound Insulation with Hilti Firestop products

Vibration Isolation of Buildings. Resilient Bedding of Buildings

ARCHITECTURAL CEILING HANGERS

SAINT-GOBAIN Soundproofing Systems for Hotels, Offices and Cinema Halls. Design Solutions Book

A joint reliance VIBRATION ISOLATOR NOISE & VIBRATION CONTROL PRODUCT VI-0107

Elastomeric Bearings for Protection against Vibration and Structure-borne Noise

Rubber-metal elements General description of rubber-metal elements

GenieMat FIT. For Weight Drop Impact Insulation. It s not magic, it s engineering. UK EDITION. Impact and Airborne Sound Control

SILENT. Rating of impact sound to standard DIN 7396:2016

Robust Acoustics Improvements for Dwellings Next to Airports

Report Number BTC 16234A

Measurement of room-to-room airborne sound insulation with an access floor in a dwelling unit of condominium

For further information about our products and installation services please call to arrange a personal consultation.

vibration and structural isolation

CONSIDERATIONS REGARDING IMPACT SOUND INSULATION PERFORMANCES OF DIFFERENT FLOOR MATERIALS

Measurement of room-to-room airborne sound insulation with an access floor in a dwelling unit of condominium

GUMMY SYSTEM RUBBER SOUNDPROOFING ACCESSORIES

High-Resilient Bearings Efficient vibration insulation in minimal space

Walraven Rooftop Solutions

Walraven Rooftop Solutions

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

This page was. intentionally. left blank

ALS 25 db(a) 30 db(a) 35 db(a) Size

SOUND INSULATION DESIGN OF MODULAR CONSTRUCTION HOUSING

The specimen B W was identified by the client as a Skyfold Classic operable partition, with panels, seals, and clearances in configuration 4E.

Air Transfer Silencer

C. Concrete Inertia Bases: Drawings showing required concrete steel reinforcing, construction details, and dimensions.

Adjustable Suspension Hanger Technical Datasheet

EIV. Circular single deflection grille for walls. Quick facts. Quick guide EIV A I R F L O W - S O U N D L E V E L

STRUCTURE-BORNE SOUND CONTRIBUTION INTO EARTH-MOVING MACHINE CABS.

Propagation of Structure-borne Sound in Lightweight Gypsum Board Walls

Division 15 VIBRATION ISOLATION AND SILENCERS Section Page 1 of 6

ACOUSTIC EFFICIENCY OF FALSE CEILINGS: STUDY ON THE INFLUENCE OF DISTANCE FROM THE CEILING SLAB

Sound insulation. Electrical installation in sound insulation walls.

Polycarbonate solid sheets with U.V. protection on both sides

Transcription:

AKUSTIK + AMC Mecanocaucho & AKUSTIK+ AKUSTIK+ AMC Mecanocaucho SOPORTES DE TECHO Akustik+ When 2 db at low frequencies make the difference

COMPARATIVE TESTS AT THE LABEIN TECHNOLOGY CENTRE Akustik+Sylomer is de trademark of a new solution for the anti-vibration mountings of false ceilings or vibrating elements that have to be suspended. They are used for the attenuation of vibrations, reducing structure-borne noise. The Akustik+Sylomer ceiling mounts are made of Sylomer, a microcelular polyurethane material specially conceived for vibration isolation. This material produces a higher degree of damping than the elastomers traditionally used for this purpose. The Labein technology centre performed a series of comparative tests to confirm the good acoustic results of Akustik+Sylomer. This centre is officially ENAC-certified and complies with the requirements of the ISO 1-1:1997 standard. PURPOSE OF THE TEST The purpose of the test is to compare, in equal conditions, the acoustic isolation to air-borne noise of a false ceiling without anti-vibration suspensions (direct transmission) to a false ceiling with the new Akustik+Sylomer suspensions. The secondary endpoint is to compare the Akustik+Sylomer to another suspension with the same size-specific characteristics using high-resilience natural rubber from our Akustik 4 4 shore A standard series. Specimen used for the test IMPORTANT NOTE: The composition of the false ceiling is not meant to be used for teaching purposes in acoustics. It is a standard implementation whose objective is to compare the anti-vibration elements. The specimen used in the tests is a standard ceramic hollow block with an approximate isolation of 4 db. TEST METHODOLOGY The reports contain the results of the noise isolation test to airborne noise conducted according to the UNE-EN ISO 1-3 standard for a false ceiling with the following ceiling mounts: Direct transmission (without antivibration suspensions). Akustik 4 4 shore A. Akustik 3 + Sylomer Type B. Besides the isolation curves, two RW and RA indexes have been calculated and used to compare the performance of the different suspensions. The Rw noise reduction index of the sample tested and the terms of adaptation of the C and Ctr spectrum were obtained according to the ISO 717-1 standard, based on the isolation curve. The pink noise isolation index RA between Hz and KHz is that which is specified by the Basic Spanish Building Standard: NBE-CA 88 Acoustic Conditions. The results and the descriptive reports can be downloaded free of charge from www.akustik.com 26

AKUSTIK + AMC Mecanocaucho & AKUSTIK+ AKUSTIK+ COMPARATIVE TESTS AT THE LABEIN TECHNOLOGY CENTRE COMPARATIVE RESULTS OF THE TEST BETWEEN A SUSPENDED CEILING WITH AND WITHOUT AKUSTIK+SYLOMER. Graphic 1 shows the isolation provided by a single plasterboard suspended with Akustik + Sylomer suspensions and the same ceiling fitted with M6 rod. The blue line represents the isolation achieved with Akustik + Sylomer mounts. As can be seen, there are major differences at low and high frequencies, offering a difference of: Akustik isolation curves Graphic 1 db 8 80 70 6 3 db at 1 Hz 6 db at 0 Hz db at 00 Hz db at 0Hz At the same time, comparative tests were conducted with ceilings with a greater number of plasterboards. Table 1 shows the results of the RW reduction index: 0 4 1 1 0 0 3 0 00 6 800 0 10 00 00 30 00 000 Frecuencia Hz 1 Board without elastic mounts 1 Board with Akustik+ Sylomer suspensions It is clear that the use of Akustik+Sylomer suspensions provides far greater airborne isolations, which in some cases are equivalent to or greater than the use of 2 or 3 plasterboards with anti-vibration ceiling mounts. Table 1 The results and descriptive reports can be downloaded free from www.akustik.com RW sound isolation index Without suspensions(m6 rod) With suspensions Akustik + 1 plasterboard 71 db db 2 plasterboard 73 db db 3 plasterboard 74 db 77 db Gain in db thanks to the use of the Akustik+Sylomer suspensions as opposed to a ceiling without elastic suspensions. 6 6,00 4 3 4,00 4,00 3,00 db 2 1 0 0 2,00 1 plasterboards 2 plasterboards 3 plasterboards Ceiling without elastic suspensions Ceiling with Akustik+Sylomer elastic suspensions 27

COMPARATIVE TESTS AT THE LABEIN TECHNOLOGY CENTRE COMPARATIVE RESULTS OF THE TEST BETWEEN A SUSPENDED CEILING WITH AKUSTIK+SYLOMER VS RUBBER SUSPENSIONS. Table 2 compares the RA sound isolation index according to the number of plasterboards. The improvement is self-evident, the akustik+sylomer mounts offer a superior isolation to the rubber mounts. This difference is so great that it may be said that a ceiling with a plasterboard withakustik+sylomer offers the same isolation as a ceiling with two plasterboard rubber suspensions. This therefore means savings in time and material. The savings in plasterboard and labour costs make these mounts particularly interesting. both technically and economically. In order to provide a better analysis of the differences between the rubber mounts and the akustik+sylomer mounts. table 3 shows the isolation data at different frequencies. The results of these tables show that the isolation differences are in the low frequency range. which is particularly interesting for the isolation of premises without soundproofing. since they are particularly difficult to isolate. Table 2 RW sound isolation index Table 3 Akustik + RUBBER 1 plasterboard db 74 db 2 plasterboard db db 3 plasterboard 77 db 76 db Suspended ceiling with 1 plasterboard FREQUENCY Akustik + RUBBER 1 Hz. 8,3 db 7, db 0 Hz. 68,4 db 66 db 00 Hz. 80,3 db 79,1 db False ceiling with 2 plasterboards FREQUENCY Akustik + RUBBER 1 Hz. 7 db 6,9 db 0 Hz. 70 db 68 db 00 Hz. 81, db 81,1 db False ceiling with 3 plasterboards FREQUENCY Akustik + RUBBER 1 Hz.,4 db 8, db 0 Hz. 69,4 db 67 db 00 Hz. 82,4 db 81,1 db 28

AKUSTIK + AMC Mecanocaucho & AKUSTIK+ AKUSTIK+ BEHAVIOUR AT HIGH AND LOW FREQUENCIES Structure-borne noise is that which is transmitted through the structures of a building, machine, installation... This radiation noise becomes airborne noise. Low noise frequencies are those that are usually less damped in the air and are therefore better transmitted through structures. The range of low frequencies is between and 00 Hz. NATURAL FREQUENCY OF THE AKUSTIK+ SYLOMER MOUNTS The akustik+sylomer ceiling mounts can obtain very low natural frequencies of up to 7 Hz at the optimal loading point. At this loading point the decoupling frequency of the akustik+sylomer mounts is 9,9Hz. Such a low natural frequency is optimal for the false ceilings of soundproofed premises. This type of suspensions are also particularly interesting for the isolation of machines or vibrating elements that work at more than 0 rpm. Examples are: Ducts / pipelines: - Of cooling liquids from refrigerating compressors, and are ideal for use in supermarkets, the frozen food section. - Air conditioning. - Pumping of water - From fume exhausts. Suspension of air conditioning machinery. Suspension of vibrating elements in general. BEHAVIOUR OF THE AKUSTIK+SYLOMER MOUNTS AT LOW FREQUENCIES IN SOUNDPROOFED PREMISES. The range of audible frequencies in the human being may vary according to age and to other factors although in general it is between Hz and.000hz. By way of example the notes produced by a guitar have a frequency range from 82 to 698 Hz. Considering that the most unfavourable excitation frequency, i.e. Hz, the isolation degree of structureborne noise produced by an akustik+sylomer suspension would be close to 90%. (*) (*) Installation of the optimal loading point of the akustik + sylomer for a theoretical single mass spring system. BEHAVIOUR OF THE AKUSTIK+SYLOMER MOUNTS AT MEDIUM AND HIGH FREQUENCIES. Sound waves are not comprised of just one frequency, but rather of a set of frequencies superimposed without any order, which is the main reason why noise is unpleasant. Thus, the ideal suspender must be able to isolate the broadest possible range of frequencies. Behaviour of a metal spring These suspenders are often recommended for the elastic suspension of false ceilings. It is important to know that this CREEPING AND LONG-TERM BEHAVIOUR type of mount is suitable for the damping of low frequencies, whereas the high frequencies are propagated through the coils of the spring. To filter this type of frequencies the springs must be combined with a stage of viscoelastic material under the spring to stop the propagation of this type of vibration. Behaviour of the akustik+ Sylomer Thanks to the viscoelastic properties of the Sylomer, the akustik+sylomer has a behaviour similar to the spring at low frequencies and at the same time not only prevents the high frequencies as occurs in the spring via its coils, but also considerably improves the behaviour of the rubber at high frequencies. These results are shown in the comparative section of Akustik + Sylomer with regard to rubber suspenders. Static loads produce a certain degree of creeping. This phenomenon can be observed in all elastomers. Creeping is the increase in deformation under consistent loading Figs. 1 and 3 show the creeping for the two types of Sylomer used for our ceiling mounts. Within the field recommended for the application of continuous loads, the additional deflection remains under 0% of the initial deflection even after an extended period of years. The dynamic stiffness of the ceiling mounts must increase as little as possible over time. Figs. 2 and 4 show the variation of the dynamic module over time of the two types of Sylomer used in our ceiling mounts. Sylomer Low Loads Relative Deflection (% of thickness) Relative Deflection (% of thickness) Sylomer High Loads 4 3 0 Fig.1 Creeping Behaviour 0 0,001 0, N/mm 2 0, N/mm 2 0,11 0 Load period (h) Fig.3 Creeping Behaviour 1d 0,3 N/mm 2 0,0 N/mm 2 0 000 0,11 1,000,000,000 1,000,000 Load period (h) 0,0 N/mm 2 1m 1a a Dynamic modulus of elasticity (N/mm 2 ) Dynamic modulus of elasticity (N/mm 2 ) 3.0 2. 2.0 1. 1.0 0. 0.0 Fig. 2 Dynamic modulus of elasticity at long term loading 6 4 1,000 h,000 h 0,1 h h 0,00,2 0,,3 0,4 Consistent loading(n/mm 2 ) Fig. 4 Dynamic modulus of elasticity at long term loading 3 2 1 0 0,0 1,000 h,000 h 0,1 h h 0,4 0,8 Consistent loading(n/mm 2 ) 29

3 Place Java, Local 1 Akustik + Sylomer : Models and dimensions PRODUCT DESCRIPTION These antivibration mounts have been conceived for suspension from false ceilings, vibrating pipelines and machinery that has to be suspended. The excellent properties of the Sylomer microcelular polyurethane achieve elevated isolation values as opposed to other mounts using rubber or cork, or a combination of both. These antivibration mounts are manufactured in two special mixes of Sylomer to adapt better to the load of each application. A great variety of fixing metal armors and elements facilitate installation and adapt better to each type of job. Their rugged metal parts withstand can tensile stresses from kg to 0 kg. They are supplied with an anticorrosive treatment that can withstand the toughest environments. FIXING METAL ARMOR SYLOMER Akustik 1 It is secured directly to the ceiling by means of two holes. O 7 46, 66 39 Akustik 3 It is secured directly to the ceiling with a screw and locking nut. 2 O7 44 O 18 39 M6 Akustik 4 It is secured with a screw via a nut welded to the metal armor. 2 44 O 18 42 ø,4 Akustik Rapid Designed to be secured to most profiles on the market. Its design makes for easy and safe installations. Akustik Safety Its gravitational system guarantees correct installation and offers greater safety, preventing elements from becoming detached. Thanks to its design, the mount will not attach to the profile if it is not installed properly. It prevents possible slip-ups. Its 4º forked design makes installation and removal easy and safe. 49 4 41 M 6 8

3 Place Java, Local 1 AKUSTIK + AMC Mecanocaucho & AKUSTIK+ AKUSTIK+ Akustik + Sylomer : Models and dimensions TYPE OF FIXING TYPE A For installations where M6 male fixing is required, the recommended fixing is Type A. 32 64 M 6 TYPE B For installations where M6 female fixing is required, the recommended fixing is Type B. M 6 11 64 O 43 Akustik Super T47 The SUPER security feature is adaptable to the different profiles existing on the market. 70 M 6 44 41 Akustik Super T The external dimension of the profiles that exist on the market may variate, our SUPER security system with lip form adapts to the different lengths of the profile having a tight fit. M 6 INSTALLATION STEPS OF AKUSTIK SUPER Detail A STEP 1 S TEP 2 STEP 3 1 The security system is adaptable to different widths of profiles. Detail B 2 The SUPER security system admits the possibility of inserting a blocking screw. 31

3 Place Java, Local 1 Akustik + Sylomer : Models and dimensions TYPES OF SYLOMER LOAD DEFLECTION GRAPH Akustik + Sylomer NATURAL FREQUENCY Akustik + Sylomer 0 0 7. RANGE OF ADMISSIBLE LOADS RANGE OF ADMISSIBLE LOADS 3 1 2 3 4 6 Deflection (mm) 8 12 6 7 9 12 Natural frequency (Hz) LOAD DEFLECTION GRAPH Akustik + Sylomer NATURAL FREQUENCY Akustik + Sylomer 0 0 0 0 RANGE OF ADMISSIBLE LOADS RANGE OF ADMISSIBLE LOADS 1. 2 3 4 6 8 Deflection (mm) 12 6 8 12 Natural frequency (Hz) Application of an Akustik 4+Sylomer type A. Application of an Akustik Super T +Sylomer type B. 32

3 Place Java, Local 1 AKUSTIK + AMC Mecanocaucho & AKUSTIK+ AKUSTIK+ Akustik + Sylomer : Range REF AMC SUMMARY (Kg) MAX. LOAD CODE Akustik 1 + Sylomer Type A Ventana del Akustik 1 fijada al techo con dos agujeros y un Type de FIXING macho M- 6. 2301 Akustik 3 + Sylomer Type A Metal armor of the akustik 3 secured to the ceiling by an M6 screwand with a nut. 2303 Akustik4 + Sylomer Type A Metal armor of the Akustik 4 secured to the ceiling by an M6 screw. 230 Akustik Rapid + Sylomer Type A Metal armor of the Akustik rapid secured to the ceiling by an M6 screw. 2307 Akustik Safety + Sylomer Type A Metal armor of the Akustik Safety secured to the ceiling by an M6 screw. 2308 Akustik 1 + Sylomer Type B Metal armor of the Akustik 3 secured to the ceiling by a welded M6 nut. 2309 Akustik 3 + Sylomer Type B Metal armor of the Akustik 4 secured to the ceiling by a welded M6 nut. 2311 Akustik4 + Sylomer Type B Metal armor of the Akustik Rapid secured to the ceiling by a welded M6 nut. 2313 Akustik Rapid + Sylomer Type B Metal armor of the Akustik Safety secured to the ceiling by an M6 screw. 23 Akustik STeguridad + Sylomer TypeB Metal armor of the Akustik Safety secured to the ceiling by a welded M6 nut. 2316 33

3 Place Java, Local 1 Akustik + Sylomer : Range REF. AMC SUMMARY (Kg) MAX. LOAD CODE Akustik 1 + Sylomer Type A Metal armor of the Akustik 1 secured to the ceiling with two holes and an M6 male fixing type (Type A). 2317 Akustik 3 + Sylomer Type A Metal armor of the akustik 3 secured to the ceiling by an M6 screw and with a nut. 2319 Akustik4 + Sylomer Type A Metal armor of the Akustik 4 secured to the ceiling by an M6 screw. 2321 Akustik Rapid + Sylomer Type A Metal armor of the Akustik rapid secured to the ceiling by an M6 screw. 2323 Akustik Safety + Sylomer Type A Metal armor of the Akustik 1 secured to the ceiling by a welded M6 nut. 2324 Akustik 1 + Sylomer Type B Metal armor of the Akustik 3 secured to the ceiling by a welded M6 nut. 23 Akustik 3 + Sylomer Type B Metal armor of the Akustik 4 secured to the ceiling by a welded M6 nut. 2327 Akustik4 + Sylomer Type B Metal armor of the Akustik Rapid secured to the ceiling by a welded M6 nut. 2329 Akustik Rapid + Sylomer Type B Metal armor of the Akustik Safety secured to the ceiling by an M6 screw. 2331 Akustik Safety + Sylomer TypeB Metal armor of the Akustik Safety secured to the ceiling by a welded M6 nut. 2333 34

Tél : 40.69.3700 3 Place Java, Local 1 AKUSTIK + AMC Mecanocaucho & AKUSTIK+ AKUSTIK + Akustik Super + Sylomer y Akustik Sierra + Sylomer : Range (KG) MAX. LOAD CODE Metal armor of the Akustik Super secured to the ceiling by an M6 screw. 2381 Akustik Super T + Sylomer Type B Metal armor of the Akustik Super secured to the ceiling by an M6 screw. 2382 Akustik Super T47 + Sylomer Type A Metal armor of the Akustik Super secured to the ceiling by an M6 screw. 23841 Akustik Super T47 + Sylomer Type B Metal armor of the Akustik Super secured to the ceiling by an M6 screw. 23842 Ø7 Denominación Izena Name Material Ekaia Material Ekaia 23831 Akustik Super T + Sylomer Type B Metal armor of the Akustik Super secured to the ceiling by an M6 screw. 23832 Real-Egina-Done A4 Real-Egina-Done A4 1:1,33 Escala Eskala Schale Escala Eskala Schale 1:1,33 39 Aprobado-Onartua-Approved Aprobado-Onartua-Approved Dibujado-Marraztuta-Drawn Dibujado-Marraztuta-Drawn Nombre-Izena-Name Nombre-Izena-Name Modificación-Aldarazpena-Modification Versión Real-Egina-Done EW NA4 Denominación Izena Name Akustik 1 Lateral + Sylomer (Standard position) Material Ekaia Escala Eskala Schale 1:1,33 Referencia-erreferentzia-Part Number Tratamiento Tratamendua Treatment 39 Aprobado-Onartua-Approved Dibujado-Marraztuta-Drawn Nombre-Izena-Name 23821 39 Akustik Super T47 + Sylomer Type B Metal armor of the Akustik Super secured to the ceiling by an M6 screw. 39 39 Metal armor of the Akustik Super secured to the ceiling by an M6 screw. 39 Referencia-erreferentzia-Part Referencia-erreferentzia-Part Number Number Tratamiento Tratamendua Treatment Akustik Super T + Sylomer Type A Ø7 Modificación-Aldarazpena-Modification Modificación-Aldarazpena-Modification Versión Denominación Izena Name Metal armor of the Akustik Super secured to the ceiling by an M6 screw. Akustik Super T47 + Sylomer Type A Ø7 66 Versión Tratamiento Tratamendua Treatment NEW 66 66 Akustik Super T + Sylomer Type A Akustik 1 Lateral + Sylomer SUMMARY REF. AMC 7 Ø Ø 23822 Ø 7 39 66 7 Denominación Izena Name Pieza de apriete del Perfil Sierra NEW 41 26 63 Akustik Sierra + Sylomer Type A 37 M6 Pieza de apriete del Perfil Sierra Akustik Sierra + Sylomer Type B Modificación-Aldarazpena-Modification Versión 62 Real-Egina-Done A3 Montaje Akustik Sierra + Sylomer Tipo A Material Ekaia Escala Eskala Schale Referencia-erreferentzia-Part Number 2386 Tratamiento Tratamendua Treatment Dibujado-Marraztuta-Drawn Nombre-Izena-Name 37 Aprobado-Onartua-Approved M6 NEW Pieza de apriete del Perfil Sierra 41 Versión Denominación Izena Name 63 Material Ekaia Tratamiento Tratamendua Treatment Akustik Sierra + Sylomer Type A Modificación-Aldarazpena-Modification Real-Egina-Done A3 Montaje Akustik Sierra + Sylomer Tipo B Escala Eskala Schale Referencia-erreferentzia-Part Number 23866 Dibujado-Marraztuta-Drawn Aprobado-Onartua-Approved 26 Nombre-Izena-Name 37 M6 NEW Pieza de apriete del Perfil Sierra 41 Akustik Sierra + Sylomer Type B Modificación-Aldarazpena-Modification Versión Denominación Izena Name Montaje Akustik Sierra + Sylomer Tipo A 62 Material Ekaia Real-Egina-Done A3 Escala Eskala Schale Referencia-erreferentzia-Part Number 23863 Tratamiento Tratamendua Treatment Dibujado-Marraztuta-Drawn Nombre-Izena-Name 37 Ventana fijada al techo mediante tornillo M6. Además, incorpora elemento de FIXING al perfil de gran sencillez. Tratamiento Tratamendua Treatment Re 66 Vers Deno Aprobado-Onartua-Approved Dibujado-Marraztuta-Drawn 2386 66 Ø Nombre-Izena-Name 7 Modificación-Aldarazpena-Modification Versión Denominación Izena Name Real-Egina-Done A3 Material Ekaia Escala Eskala Schale 1:1 M E Tra Trat Tr Referencia-erreferentzia-Part Number Nom Tratamiento Tratamendua Treatment Fech Dibujado-Marraztuta-Drawn Aprobado-Onartua-Approved Nombre-Izena-Name NEW 41 Denominación Izena Name Material Ekaia M6 Modificación-Aldarazpena-Modification Versión Aprobado-Onartua-Approved Versión Denominación Izena Name Material Ekaia Tratamiento Modificación-Aldarazpena-Modification Montaje Akustik Sierra + Sylomer Tipo B Real-Egina-Done A3 Escala Eskala Schale Referencia-erreferentzia-Part Number 23864 Ventana fijada al techo mediante tuerca soldada M6. Además, incorpora elemento de FIXING al perfil de gran sencillez. Ventana fijada al techo mediante tornillo M6. Además, incorpora elemento de FIXING al perfil de gran sencillez. Ventana fijada al techo mediante tuerca soldada M6. Además, incorpora elemento de FIXING al perfil de gran sencillez. 66 Versión Modificación-Aldarazpena-Modification Denominación Izena Name Material Ekaia 23866 Re Tratamiento Tratamendua Treatment Dibujado-Marraztuta-Drawn Nombre-Izena-Name (Kg) max. load CODE Akustik 1 Lateral + Sylomer Type A 2373 Akustik 1 Lateral + Sylomer Type A 2374 Akustik 1 Lateral + Sylomer Type B 23 Akustik 1 Lateral + Sylomer Type B 2326 REF. AMC 23863 23864 3 Aprobado-Onartua-Approved

3 Place Java, Local 1 Grand Akustik + Sylomer : Models and dimensions PRODUCT DESCRIPTION These anivibration mounts have been conceived for suspension from false ceilings, vibrating pipelines and machinery that has to be suspended. The excellent properties of the Sylomer microcelular polyurethane achieve elevated isolation values as opposed to other mounts using rubber or cork, or a combination of both. These antivibration mounts are manufactured in two special mixes of Sylomer to adapt better to the load of each application. A great variery of fixing windows and elements facilitate installation and adapt better to each type of job. Their rugged metal parts can withstand tensile stresses from to 0 Kg. They are supplied with an anticorrosive treatment that can withstand the toughest environments. FIXING METAL ARMOR SYLOMER 3 4 9 O 11 Grand Akustik 1 It is secured to the ceiling with two holes. 62 13 A Grand Akustik 2 It is secured directly to the ceiling by means of a screw. M 6 67 A 6 A 3 Grand Akustik 3 It is secured directly to the ceiling by means of one screw and to the inverted double T type profile thanks to the design of its metal armor. O 6 21 21 6 A 36

3 Place Java, Local 1 AKUSTIK + AMC Mecanocaucho & AKUSTIK+ AKUSTIK+ Grand Akustik + Sylomer : Models and dimensions TYPE OF FIXING Type A For installations where M6 male fixing is required, the recommended fixing is Type A. 32 64 M 6 Type B For installations where M6 female fixing is required, the recommended fixing is Type B. M 6 11 64 TYPES OF SYLOMER LOAD DEFLECTION GRAPH Grand Akustik + Sylomer NATURAL FREQUENCY GRAPHS Grand Akustik + Sylomer 1 90 1 4 STATIC LOAD AREA STATIC LOAD AREA 1. 2 3 4 6 8 12 Deflection (mm) 6 7 9 12 Natural frequency (Hz) LOAD DEFLECTION GRAPH Grand Akustik + Sylomer 0 NATURAL FREQUENCY GRAPHS Grand Akustik + Sylomer 0 0 0 0 0 1 0 RANGE OF ADMISSIBLE LOADS 4 RANGE OF ADMISSIBLE LOADS 1. 2 3 4 6 8 Deflection (mm) 6 7 9 12 Natural frequency (Hz) 37

3 Place Java, Local 1 Gran Akustik + Sylomer : Range REF. AMC SUMMARY (Kg) MAX. LOAD CODE Gran Akustik 1 + Sylomer Type A It is secured directly to the ceiling by means of two holes and to the profile by means of a type A screw. 231 Gran Akustik 2 + Sylomer Type A It is secured directly to the ceiling by means of one screw and to the profile by means of a type A screw. 23 Gran Akustik3 + Sylomer Type A It is secured directly to the ceiling by means of one screw and to the inverted double T type profile thanks to the design of its metal armor. 237 Gran Akustik 1 + Sylomer Type B It is secured to the ceiling with two holes and to the profile by means of a type B female fixing. 239 Gran Akustik 2 + Sylomer Type B It is secured to the ceiling by a screw and to the profile by a type B female fixing. 23613 Gran Akustik 3 + Sylomer Type B It is secured directly to the ceiling by means of a Type B female fixing and to the inverted double T type profile thanks to the design of its metal armor. 236 38

3 Place Java, Local 1 AKUSTIK + AMC Mecanocaucho & AKUSTIK+ AKUSTIK+ Gran Akustik + Sylomer : Range REF. AMC SUMMARY (Kg) MAX. LOAD CODE Gran Akustik 1 + Sylomer 0 Type A It is secured directly to the ceiling with two holes and to the profile by means of a type A male screw. 0 23617 Gran Akustik 2 Type A It is secured directly to the ceiling with one screw and to the profile by means of a type A screw. 0 23621 Gran Akustik3 + Sylomer 0 Type A It is secured directly to the ceiling by means of one screw and to the inverted double T type profile thanks to the design of its metal armor. 0 23623 Gran Akustik 1 + Sylomer 0 Type B It is secured directly to the ceiling by means of two screws and to the profile by means of a type B female fixing. 0 236 Gran Akustik 2 + Sylomer 0 Type B It is secured directly to the ceiling by means of one screw and to the profile by means of a type B female fixing. 0 23629 Gran Akustik 3 + Sylomer 0 Type B It is secured directly to the ceiling by means of one type B female screw and to the inverted double T type profile thanks to the design of its metal armor. 0 23631 39

3 Place Java, Local 1 SRS + Sylomer : Models and dimensions PRODUCT DESCRIPTION These antivibration mounts have been conceived for the suspension of suspended ceilings or machines that rotate at low frequency. The excellent properties of the Sylomer microcelular polyurethane combined with the low stiffness of an steel spring achieve increased isolation values as opposed to other mounts using rubber or cork, or a combination of both. These antivibration mounts are manufactured in 6 different steel spring models to adapt optimal for each application. Their rugged metal parts withstand can tensile stresses. They are supplied with an anticorrosive treatment that can resist tensile stresses up to 0Kg withstand the toughest environments. SYLOMER METAL HOUSING A 12 M8 M8 0 97 0 RUBBER BASE STEEL SPRING 79 A SECTION A-A 0 0 1 0 NATURAL Frequency CURVE: SRS + Sylomer SRS 0 SRS 1 SRS SRS SRS 0 SRS PERMISSIBLE LOAD RANGE 0 0 1 0 LOAD DEFLECTION CURVE: SRS + Sylomer PERMISSIBLE LOAD RANGE SRS 0 SRS 1 SRS SRS SRS 0 SRS 3 4 7 12 18 22 Natural frequency (Hz) 1 1, 3 4 7 12 1822 Deflection (mm)

3 Place Java, Local 1 AKUSTIK + AMC Mecanocaucho & AKUSTIK+ AKUSTIK+ SRS + Sylomer : Range REF. AMC SUMMARY (Kg). MAX.LOAD CODE SRS + Sylomer Sylomer+Steel spring combined hanger. 2346 SRS 0 + Sylomer Sylomer+Steel spring combined hanger. 0 2347 SRS + Sylomer Sylomer+Steel spring combined hanger. 231 SRS + Sylomer Sylomer+Steel spring combined hanger. 2348 SRS 1 + Sylomer Sylomer+Steel spring combined hanger. 1 2349 SRS 0 + Sylomer Sylomer+Steel spring combined hanger. 0 230 41

3 Place Java, Local 1 WALL MOUNTS EP + Sylomer : Models and dimensions LOAD AMC DEL PRODUCTO Range designed for the floating suspension of soundproofed walls. Sylomer avoids the transmission of vibrations while providing optimal acoustic results. They have a FAIL SAFE rugged metal structure, which is overload-proof. Recommended for applications where fire or impact resistance is necessary. These mounts are also suitable for the isolation of vertical pipes, or any type of lightweight ducts that need to be isolated. 96 EP + Sylomer Type B It is secured to the wall by means of two holes. It has a female M6 metal insert. 62 ø 7 M 6 3 2 M 6 EP + Sylomer Type A It is secured to the wall by means of two holes. It has a female M6 metal insert. ø7 3 26, 62 96 ø4 EP0 + Sylomer 72 EP 0 + Sylomer 1,3 They are secured by two predrilled and easy-tocut pins to facilitate their installation. It is secured to the wall by means of two holes. It has a male M6 metal insert and also an L welded nut for securing to the profile. ø7 28 4 3 62 96 42

AKUSTIK + AMC Mecanocaucho & AKUSTIK+ AKUSTIK+ WALL MOUNTS EP + Sylomer : Models and dimensions EP + Sylomer They are secured by two predrilled and bent pins to facilitate their installation. 2 This principle can be used to make a wide range of variants. ø 4 Contact us if you require a product more adapted to your building technique. 1 EP 700 + Sylomer This wall mount has been designed to hold C profiles either in vertical or horizontal position. Allows inclinated ceilings with a simple and fast installation procedure. 98 67,8 6 Ø 6,8 1, 33 3 Tél : 40.69.3700 3 Place Java, Local 1 Ø 4,4 122 TECHNICAL CHARACTERISTICS LOAD DEFLECTION GRAPH EP Akustik + Sylomer NATURAL FREQUENCY GRAPH EP Akustik + Sylomer 0 0 0 - RANGE OF ADMISSIBLE LOADS RANGE OF ADMISSIBLE LOADS - - - - RANGE OF ADMISSIBLE LOADS -0-8 - -3-2 0 2 3 8 3 4 6 8 12 Deflection (mm) Frequency (Hz) 43

3 Place Java, Local 1 WALL MOUNTS EP + Sylomer : Range REF. AMC INSTALLATION EXAMPLE CODE EP + Sylomer Type B 23701 EP + Sylomer Type A 23703 EP0 + Sylomer 2370 EP 0 + Sylomer 23707 EP + Sylomer 23709 REF. AMC (Kg). MAX.LOAD CODE EP 700 + Sylomer 23711 EP 700 + Sylomer 23712 44

3 Place Java, Local 1 AKUSTIK + AMC Mecanocaucho & AKUSTIK+ AKUSTIK+ WALL MOUNTS EP + Sylomer : Applications Euskalduna Auditorium Bilbao Music School Helsinki 4