DISINFECTION QUALIFI CATION TESTING CONSIDERATIONS FOR THE ASEPTIC AND CLEANROOM MANUFACTURING ENVIRONMENT

Similar documents
Disinfection Qualification Testing

Current Industry Trends -Including Cleaning and Disinfection trends, Disinfectant Validation Trends, and Current Warning Letter Activity.

Disinfectant Qualification A Multifaceted Study

Today s Topics. General Quality Control Best Practices. Practices Antimicrobial Effectiveness Testing(AET) Best Practices Environmental Isolates

IN THIS SECTION MICROBIOLOGY TESTING EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT. Bacterial Endotoxin (LAL) Testing

The Microbiological Requirements of a Stability Study. Ngoc Anh-Thu Phan 19 th June 2012

Avoid recurrent microbial contamination using trending of historical data. El Azab Walid Technical Service Manager STERIS

TECHNICAL LEAFLET. MEDI-MEDIA-FILL KIT SUPPLY PACKAGE (Code: MR-25/S)

Test Method for Efficacy of Copper Alloy Surfaces as a Sanitizer

Subpart B Organization and Personnel, 21 CFR Responsibilities of the quality control unit.

Antimicrobial effectiveness evaluation of Isocide powder coating versus stainless steel plate

Test Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces

The Parenteral Drug Association

Principles of Preservation

Managing Your Environmental Isolates

ANALYTICAL REPORT: Comparison of the Microbial Recovery Efficacy of QI Medical EnviroTest Paddles versus a Conventional Contact Plate

á61ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: MICROBIAL ENUMERATION TESTS

Industry Case Study: A Microbial Investigation of Contamination by Burkholderia multivorans. Jim Klein and Geert Verdonk Merck & Co., Inc.

Preservation Efficacy Testing

Puritan Environmental Sampling Kit (ESK )

Microbiological Cleaning Method Validation

Robert Westney, M.S., RAC, CMQ/OE Director of Quality and Operations Cryologics, Inc. March 7, 2017

GUIDE TO INSPECTIONS OF MICROBIOLOGICAL PHARMACEUTICAL QUALITY CONTROL LABORATORIES

Study Title Antibacterial Efficacy of Bio-Care Technology's Non-Porous Test Substance

Managing Your Environmental Isolates

3.3.1 Microbial enumeration tests

KORALONE C-204 Preservative for Household and Industrial & Institutional Products

Method Suitability Report Membrane Filtration Sterility Test with QTMicro Apparatus

Guidance. Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography (PET) Drugs DRAFT GUIDANCE

Decontamination Effectiveness of Esco Celsafe CO2 Incubator Sterilization Feature using High Heat Temperature By Bekti Tri Sumaryati

Tests to Support Sterility Claim. Imtiaz Ahmed

Inspections, Compliance, Enforcement, and Criminal Investigations

11/1/2010. Key Points to Remember

ONAMER M. PRESERVATIVE and ANTIMICROBIAL ONAMER

Overview of Inspection Issues with Legacy Products. Barbara Breithaupt Consumer Safety Officer

Growth Promotion Test Guide for Media Used in Sterility Tests

The New Choice in Disinfection Technology

Preservative Testing Choice of Challenge Isolates

Residue removal in Cleanroom Environments

Antimicrobial Lab Test Report

Premium PAA. Sanitation with Peracetic Acid

Complaints Investigations Root Cause Analysis

Case study Microbiological excursion during a phase I PQ of a WFI system. Walid El Azab Technical Service Manager STERIS Life Science

Final text for addition to The International Pharmacopoeia

BIO & PHARMA ANALYTICAL TECHNIQUES

Study Summary. Results: All tested media-filled vials were negative for growth of any microorganisms.

Cleaning Efficiency of The MicroOne Wipe and Mop Cleaning System

MICROBIOLOGICAL CULTURE MEDIA

3.2 Test for sterility

Microbiology Testing: USP requirements for Sterile and Nonsterile Preparations Webinar Q&A

Environmental Monitoring of Aseptic Processing Areas - 2

Guidance for Industry

Efficacy Report Summarization for SoClean 2

Working document QAS/ June 2011 RESTRICTED DRAFT FOR COMMENT

FINAL REPORT. Bacterial Survival on Glass and Laminated Wood Surfaces Exposed to PURE-LIGHT Coated LED Light Bulbs. Order Number:

Overview of Inspection Issues with Legacy Products

This study report is published with the express written consent of Antimicrobial Test Laboratories. Business Mobility Now!

Result:COMPLETE Report Date: December 28 th, 2015

European Pharmacopoeia

MICROBIOLOGICAL PROFILE

USP <1116> and Contamination

The most effective bio-decontamination equipment. Innovative solutions for life sciences

ROCIMA 30 Microbicide

Published Standards ISO General instructions for microbiological examination ISO Enumeration and detection of aerobic mesophilic bacteri

GLP TESTING OF ZEROMOLD PLUS FOR ACINETOBACTER BAUMANNII

Working document QAS/11.415/Rev. 1 August 2011 RESTRICTED DRAFT FOR COMMENT

The Application of Pharmaceutical cgmp to Live Bacterial Products. James Harris Business Development Manager


A Case Study for an Improved Approach to Cleanroom Disinfection, Minimizing the Impact and Reducing Downtime

January 22, WARNING LETTER CHI-03-09

Preparing Your Aseptic Processing Facility for an FDA Inspection. Valerie Welter, Director Quality Bayer HealthCare March 10, 2014

Testing the Effectiveness of Antiseptics and Disinfectants *

Biological Indicators and H 2 O 2 Decontamination of Isolator Systems. Volker Sigwarth Skan AG Switzerland. Process Development

ISO INTERNATIONAL STANDARD

Microsol4. General Purpose Decontaminant Effective Against DNA/RNA Contamination

Aseptic Process Validation

Standard Operating Procedure Title: Stock Suspensions of Micro-Organisms

Persistence of Activity of a Hand Sanitizer

Surface Fungicidal Activity of Clinell Universal Wipes ~ Project Report Prepared for Gama Healthcare Ltd.

Technical Report: (6616) December 05, 2016 Date Received: December 05, 2016 Page 1 of 6

Final text for addition to The International Pharmacopoeia

STERILIZATION VALIDATION IN THIS SECTION REPROCESSING VALIDATIONS FOR REUSABLE MEDICAL DEVICES. Radiation Sterilization Validation

STERI-7 XTRA Concentrate Technical Information

Innovative H 2 O 2 V-Phase biodecontamination solutions

Microbiological Consideration for Non-Sterile Pharmaceutical

LABORATORY COMPLIANCE

Test Organisms: Staphylococcus aureus (ATCC 6538) Escherichia coli (ATCC 11229) Pseudomonas aeruginosa (15442)

Study Title Antimicrobial Activity and Efficacy of Seal Shield's Electroclave. Test Method Custom Device Study. Study Identification Number NG7233

Accugen Laboratories, Inc.

Bioburden Contamination Control: A Holistic Overview

Handbook of Microbiological Quality Control

Study Title Antibacterial Activity and Efficacy of KHG FiteBac Technology Test Substance Using a Suspension Time-Kill Procedure

Disinfectant Qualification Bacteria, Fungi, Viruses and Atypical Organisms A Step by Step Workshop

Human Microbiota: proof of concept to production. Michael van der Horst Process Engineer Technical Operations SynCo Bio Partners B.V.

Indigo-Clean White Paper: #1 Bactericidal Performance Testing of Indigo-Clean Upon Bacterial Species. Healthcare

This document is a preview generated by EVS

Trinity College Dublin QP Forum 2017 Tuesday 25 th April

Specifications, Methods and precedence of source with particular reference to microbiological requirements in TGOs.

Slate Steel (Mild Steel) Ceramic

The Effect of Air Pockets on the Efficiency of Disinfection of Respiratory Equipment by Pasteurization

Transcription:

DISINFECTION QUALIFI CATION TESTING CONSIDERATIONS FOR THE ASEPTIC AND CLEANROOM MANUFACTURING ENVIRONMENT by Dave Rottjakob, M.T. (ASCP) December, 2013

INTRODUCTION Obtaining the highest confidence that aseptic, cleanroom, and other critical manufacturing environments are properly cleaned, sanitized and disinfected is paramount in assuring the production of safe and effective pharmaceutical products and/or medical devices. The microbiological safety of these products is primarily determined by the quality of raw materials, the integrity of the manufacturing process, as well as the effectiveness of cleaning and disinfection procedures performed in the facility. It is for this reason that the U.S. Food and Drug Administration (FDA) requires manufacturers of pharmaceutical and other critical products to qualify and validate the disinfection procedures used in these manufacturing environments. This paper is intended to provide an overview of disinfection qualification testing and the considerations that must be addressed when designing and executing these studies. WHAT IS DISINFECTION QUALIFICATION? Disinfection and sanitization in the pharmaceutical and controlled manufacturing spaces refer to the killing, inactivation, removal or reduction of contaminating microorganisms to levels considered safe per industry standards and regulations. The terms cleanroom disinfection qualification, disinfection validation, and cleaning validation are often used in the pharmaceutical and aseptic manufacturing industries interchangeably. While these terms seem to define the same thing, they are actually rather different. In fact, validations build upon qualifications. The FDA requires that all aseptic and sterile manufactures to qualify disinfection products and procedures with a formal disinfection qualification study. Disinfection qualifications formally evaluate the efficacy and suitability of antimicrobial products and procedures used to eliminate contaminant microorganisms on various surface types and components within an aseptic, sterile or otherwise controlled manufacturing environment. Disinfection qualifications are critical in assuring the microbial control of a manufacturing environment by qualifying the appropriate use and effectiveness of disinfection products and procedures. Disinfection qualifications are not disinfection validations. A disinfection validation assures that the sterile, aseptic and even non-sterile manufacturing environments are under microbial control as measured by a comprehensive and continuous environmental monitoring program. Furthermore, disinfection qualifications are not cleaning validations. Cleaning validations are studies designed to measure a procedure s effectiveness at removing by-products or residual chemicals which may result during the manufacturing process. DISINFECTION QUALIFCIATION TESTING CONSIDERATIONS, DECEMBER, 2013 ATS LABS 2

WHY ARE DISINFECTION QUALIFICATION STUDIES IMPORTANT? Disinfection qualifications effectively mitigate the microbial contamination that may occur during the manufacture of a product. Mitigating such contamination ultimately helps to ensure a safe product for the end-user or patient. Control of microbial contamination is required by the FDA s CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS as defined in 21 CFR 211.113 which states: Control of Microbiological Contamination (a) Appropriate written procedures, designed to prevent objectionable microorganisms in drug products not required to be sterile, shall be established and followed. (b) Appropriate written procedures, designed to prevent microbiological contamination of drug products purporting to be sterile, shall be established and followed. Such procedures shall include validation of all aseptic and sterilization processes. These requirements are additionally clarified in FDA s 2004 Guidance for Industry Drug Products Produced by Processing- Current Good Manufacturing Practice. This guidance addresses disinfection qualification stating: Disinfection Efficacy The suitability, efficacy, and limitations of disinfecting agents and procedures should be assessed. The effectiveness of these disinfectants and procedures should be measured by their ability to ensure that potential contaminants are adequately removed from surfaces. While federal regulations and guidance documents mandate microbial control of sterile and non-sterile manufacturing environments, the interpretation and enforcement of these regulations can be seen through GMP inspections and the resulting FDA Form 483 warning letters. The extent of the deficiencies listed in a 483 warning letter can mean the difference between being operational or being shut down. It has been well documented that the observations citing the failure to ensure disinfection in 483 warning letters have been trending upward. DISINFECTION QUALIFCIATION TESTING CONSIDERATIONS, DECEMBER, 2013 ATS LABS 3

RECENT FDA FORM 483 WARNING LETTER EXCERPTS: Your firm has not established procedures designed to prevent microbiological contamination of drug products purporting to be sterile. Warning Letter dated February 22, 2012 Your disinfectant qualification for (b)(4) and (b)(4) bi-spore disinfectants documented that the log reduction criteria (Bacteria>4, Fungi>3) was not met when challenged with multiple organisms in a variety of surfaces. After disinfection, you recovered Micrococcus luteus on vinyl, (b)(4), stainless steel, glass and wall laminate and Enterobacter cloacae, Rhodococcus sp, Burkholderia cepacia, Pseudomonas aeruginosa, Methylobacterium mesophilicum and, Acinetobacter lwoffi on glass. However your procedures for routine cleaning of the aseptic manufacturing area continue to require the use of unqualified disinfectants during days (b)(4) through (b)(4) of your disinfection program. Warning Letter dated October 7, 2011 The qualification of your disinfectant (b)(4) failed to demonstrate that it is suitable and effective to remove microorganisms from different surfaces. Specifically, this disinfectant failed to meet the qualification criteria when challenged with multiple organisms. Warning Letter dated October 7, 2011. We note that the cgmp violations listed in this letter include similar violations to those cited in the previous inspection in February 2008 [ ] 3) failure to adequately conduct disinfectant efficacy studies, and 4) inadequate quality control unit oversight. Warning Letter dated July 14, 2011. The materials that were tested in the Disinfectant Efficacy study were not representative of all the surfaces present in the Aseptic Processing Area. [ ] The stainless steel coupon tested did not represent these damaged surfaces. Warning Letter dated May 25, 2011. Resource: http://www.fda.gov/iceci/enforcementactions/warningletters/default.htm DISINFECTION QUALIFCIATION TESTING CONSIDERATIONS, DECEMBER, 2013 ATS LABS 4

WHY DOES THE FDA REQUIRE DISINFECTION QUALIFICATION STUDIES? United States Pharmacopoeia (USP) <1072> Disinfectants and Antiseptics states that the disinfection qualification study is considered necessary since critical process steps like disinfection of aseptic processing areas, as required by GMP regulation, need to be validated and the EPA registration requirements do not address how disinfectants are used in the pharmaceutical, biotechnological and medical device industries. To better understand this nuance, you must first understand the regulation of disinfectant and sanitizer products themselves. Before disinfectant products can be sold in the United States, the products must be registered with the Environmental Protection Agency (EPA) to support the efficacy label claims. In short, standardized testing is performed using quality control strain microorganisms (e.g., Staphylococcus aureus and Pseudomonas aeruginosa) on a single representative hard surface such as stainless steel or glass to generate disinfection claims. In contrast to these claims, the manufacturing environment utilizes a wide variety of surface types and encounters a wide variety of microbes. This difference is notable. A disinfectant product that has a standard label claim for efficacy, as supported on stainless steel or glass surfaces, does not often demonstrate the same level of efficacy on other surface types against the specific environmental isolates found in the manufacturing environment. Therefore, disinfection assessment techniques must be modified to evaluate the true uses of the product in these environments. For example, it is often necessary to increase the contact time from what is listed on the product label to achieve the desired efficacy. Table 1 displays the differences found in log 10 reductions using the same test organism and disinfectant on multiple surface types. The table illustrates that with the particular disinfectant studied, microbial reduction from plastic based surfaces was relatively less efficient than the obtained reduction from stainless steel. The anomalies are highlighted in red. Table 1: Example of Differences in Microorganism Reduction Found on Multiple Surface Types Using the Same Product Active Ingredient (5 min. Exposure Time) Peracetic acid/ Hydrogen peroxide Log 10 Reduction of Environmental Isolate (Staphylococcus sp.) on the Following Routine Surfaces PVC Lexan Vinyl Epoxy Stainless Steel Glass Polypropylene Polyethylene >4.62 >4.45 >4.38 >4.25 >4.67 >4.21 >4.55 >4.32 Quaternary Ammonium >4.21 >4.12 2.78 4.66 >4.23 2.62 >4.35 >4.6 Hydrogen Peroxide 1.62 1.15 <1.21 1.87 >3.79 <0.87 1.72 1.25 Sodium Hypochlorite >4.03 >4.36 >4.83 >4.20 >3.85 3.94 >4.54 >4.62 Alkaline Phenolic >4.03 >4.36 2.57 4.20 >3.85 <1.02 >4.54 1.68 DISINFECTION QUALIFCIATION TESTING CONSIDERATIONS, DECEMBER, 2013 ATS LABS 5

WHEN SHOULD DISINFECTION QUALIFICATION STUDIES BE CONDUCTED? The ideal time to conduct a disinfection qualification study is at the construction of the manufacturing facility, prior to operation, when disinfection processes and products are being considered. At a minimum, a qualification should be performed prior to starting full scale GMP manufacturing operations and prior to an FDA GMP audit. Unfortunately, disinfection qualifications are often performed reactively instead of proactively, either in response to a product contamination, an environmental monitoring excursion, or to the observations listed in the feared FDA Form 483 warning letter. Waiting to perform a qualification study in these scenarios can lead to a cease in manufacturing operations and the commissioning of a disinfection qualification study much larger than necessary. Once the procedures have been qualified, the manufacturing environment should be continuously monitored to identify newly trending environmental isolates. This allows manufacturing facilities to successfully determine when additional disinfection qualification testing is necessary. In addition, supplemental qualifications should be performed following a change in a disinfectant product, a modification in cleaning or disinfection procedures and the incorporation of any new surfaces into the cleanroom or aseptic manufacturing area. BE PROACTIVE! Studies should be conducted: 1. Before full-scale manufacturing 2. When changing disinfectants 3. When changing procedures 4. Before FDA audits Do not wait until it s too late. HOW SHOULD DISINFECTION QUALIFICATION STUDIES BE PERFORMED? As previously mentioned, the disinfection and sanitization of surfaces in the pharmaceutical and controlled environment manufacturing space refers to the killing, inactivation, removal and reduction of contaminating microorganisms to levels considered safe per industry standards and regulations. But how are disinfection qualification studies to be performed? Unfortunately, there is no standard method outlining step-by-step instructions of how disinfection qualifications studies should be conducted. However, general guidance can be found in the United States Pharmacopeia (USP) <1072> document and in the ASTM International E2614 guidance document. DISINFECTION QUALIFCIATION TESTING CONSIDERATIONS, DECEMBER, 2013 ATS LABS 6

Suspension-based Testing vs. Coupon-based Testing In general, disinfectant efficacy evaluations are made using either suspension-based methods or coupon/surfacebased methods. Suspension methods evaluate the reduction of a known organism population inoculated directly into a sample of the liquid disinfectant. Following inoculation and the observation of a pre-determined contact time, samples of the inoculated substance are removed, neutralized and evaluated for survivors as compared to an untreated control suspension. Since the simulation of organism films on the specific surface types used in the space is not accounted for in this method, it is recommended that suspension-based tests be used only for initial disinfectant screening purposes. In contrast, coupon/surface-based testing is more rigorous and involves the creation of a dried organism film onto representative surface types which best simulates the contaminated environment. The surfaces are then exposed with the disinfectant utilizing a simulated-use procedure. Following a pre-determined contact time, each surface is neutralized and surviving organisms are enumerated in a quantitative fashion for comparison to untreated surfaces. As is evidenced by FDA 483 warning letters, coupon-based testing is recommended to qualify disinfectants used in the pharmaceutical and aseptic manufacturing arena. Scope of Qualification Testing Each manufacturing facility is different and therefore each qualification study is different. Considering the various combinations of surfaces, organisms, disinfectant products and disinfection procedures, these studies can become rather complex. Tables 2, 3 and 4 list common considerations that contribute to the complexity of these tests and help illustrate why careful scientific rationale should be used in the design of the studies. Table 2: Surface Types Surface Types Commonly found in the Pharmaceutical/Aseptic Manufacturing Environment Stainless steel (304 or 316 grade) Polyvinyl chloride (PVC) Glass Lexan (plexiglass) Polyethylene Tyvek Terazzo tile Teflon Polypropylene Fiberglass-reinforced Plastic Anodized Aluminum alloys Table 3: Challenge Microorganisms Typical Challenge Microorganisms Used in Disinfection Qualification Studies Standard Reference Isolates Environmental Isolates Vegetative Bacteria Staphylococcus aureus Escherichia coli Pseudomonas aeruginosa Candida albicans Aspergillus brasiliensis Penicillium chrysogenum Bacillus subtilis Micrococcus luteus Staphylococcus hominis Staphylococcus epidermidis Burkholderia cepacia Corynebacterium species Yeast and Mold (Fungi) Aspergillus species Penicillium species Spore-forming Bacteria Bacillus species Paenibacillus glucanolyticus DISINFECTION QUALIFCIATION TESTING CONSIDERATIONS, DECEMBER, 2013 ATS LABS 7

Table 4: Active Ingredients of Typical Disinfectant Products and Typical Method Applications Active Ingredients of Typical Disinfectant Products Used in Aseptic Manufacturing Peracetic acid/ Hydrogen peroxide Quaternary Ammonium Alcohol (Ethanol/Isopropyl) Sodium Hypochlorite Alkaline Phenolic Acidic Phenolic Hydrogen Peroxide Typical Methods for Application Of Disinfectants in the Aseptic Manufacturing Environment Mop-on Spray Wipe Flood With or without rinse step With or without squeegee Fogging or Submersion In addition to the aforementioned testing considerations, the following technical elements, amongst others, must be given serious consideration while developing the scope of the study: Coupon/Carrier Preparation Organism Preparation, and Coupon Inoculation Drying Conditions for Optimal Organism Viability Disinfectant Preparation Determination and Testing of Expiration time for Diluted or Activated products Disinfectant Application and Exposure Times Neutralization of Coupons and Recovery of Survivors Disinfectant Performance Criteria (e.g., contact time and concentration) The explanation of these technical elements falls outside of the scope of this document but will be the subject of a forthcoming white paper. The following provides an overview of the procedures commonly used in these studies. OVERVIEW OF STUDY DESIGN Once the study parameters have been established, a testing protocol is developed. The overall testing process is generally executed as follows. Each surface coupon is individually inoculated with test organism. A sufficient number of coupons must be inoculated to evaluate each disinfectant, each test organism and each disinfection procedure for each coupon replicate. The coupons are placed into an incubator to allow the test organism to dry as a film. Once dried, each coupon is treated and exposed to the disinfectant. Following careful monitoring of the exposure, each coupon is transferred to a pre-selected solution designed to neutralize the disinfectant and elute or rinse off any surviving test organisms. This solution is quantitatively evaluated to enumerate the number of survivors onto an appropriate agar plate medium. Untreated, inoculated, coupons are similarly enumerated to determine the starting level of test organism on each surface type prior to treatment. Appropriate controls should be included with the study to assess the sterility of the materials used in testing and to confirm the adequacy of the neutralization techniques used. DISINFECTION QUALIFCIATION TESTING CONSIDERATIONS, DECEMBER, 2013 ATS LABS 8

After incubation, the recovery plates are enumerated and the study controls are evaluated to assure study validity. Survivors found on the treated coupons are compared to survivors recovered on the untreated control coupons to determine the log 10 reductions. The level of reduction observed can then be used to assess the success of the disinfection procedure. CONCLUSION Properly designed, appropriately qualified and consistently executed disinfection procedures are critical to the production of safe and effective biopharmaceuticals, medical devices and other sterile or non-sterile products. As demonstrated in various FDA Form 483 warning letters, the proper qualification of these disinfection procedures is required. The major considerations and potential variables that must be addressed when considering the design and execution of a successful disinfection qualification study have been outlined in this document. Careful review of the data collected in properly executed qualification studies will help facilities monitor potential deficiencies in their cleaning and disinfection program. As a result of the disinfection qualification studies, future trends that fall outside the pre-established disinfection program will allow facility staff to investigate and take corrective action to re-establish environmental control ultimately ensuring a safer product for the end-user or patient. With a properly designed disinfection program, manufacturers can better control the risk of microbial contamination, ensuring safe products for patients. DISINFECTION QUALIFCIATION TESTING CONSIDERATIONS, DECEMBER, 2013 ATS LABS 9

REFERENCES 1. United States Pharmacopeia (USP) 34, Chapter <1072> Disinfection and Antiseptics General Information pp.579-580, May 1, 2011. 2. American Society for Testing and Materials (ASTM). Test Method, Standard Guide for Evaluation of Cleanroom Disinfectants, E2614-08. 3. U.S. Food and Drug Administration (FDA), Guidance for Industry Sterile Drug Products Produced by Aseptic Processing- Current Good Manufacturing Practice, 2004. 4. Block, SS, Disinfection, Sterilization, and Preservation. Lippincott, Williams and Wilkins, Philadelphia, PA., 2001. 5. Madsen, R.E and Moldenhauer, J. Contamination Control in Healthcare Product Manufacturing, Volume 1., DHI Publishing, River Grove, IL. (2013). 6. Inspections, Compliance, Enforcement, and Criminal Investigations, Retrieved http://www.fda.gov/iceci/enforcementactions/warningletters/default.htm, 2013. 7. Current Good Manufacturing Practice for Finished Pharmaceuticals, 21 CFR Part 211. ABOUT ATS LABS ATS Labs is an antimicrobial testing laboratory providing the developers, manufacturers, and users of antimicrobial products with a comprehensive range of microbiology, virology and product chemistry services to meet both product development and regulatory testing needs. ATS Labs has delivered the highest quality scientific data to clients for over 20 years. The scientific, quality assurance and administrative staff have built a strong reputation for antimicrobial technical expertise, regulatory compliance knowledge, and client service. FOR MORE INFORMATION CONTACT 651.379.5510 www.ats-labs.com TOLL FREE 1.877.ATS.TEST (1.877.287.8378) FAX 651.379.5549 1285 Corporate Center Drive, Suite 110 Eagan, MN 55121 2013 ATS Labs All rights reserved. DISINFECTION QUALIFCIATION TESTING CONSIDERATIONS, DECEMBER, 2013 ATS LABS 10