Click on image to enlarge.

Similar documents
GABIONS AND REVET MATTRESSES

GABIONS - Galvanized

GABIONS PVC Coated. Product Standard Specifications Installation Instructions Method of Measurement and Payment. Update: May 1999

1:100 GABION WALLS LEGEND NOT FOR CONSTRUCTION TYPICAL DRAWING TEXT SETTING TYPE CHARACTER HEIGHT PEN SETUP FOR PLOTTING SUBTITLE

Gabions. Introduction

ROAD COMMISSION FOR OAKLAND COUNTY. SPECIAL PROVISION FOR GABION WALL RCOC/DESIGN: AB Page 1 of 8 RCOC12SP706F 10/28/2013

Section Gabions Tender No. [ ] Page The following detail drawings are appended hereto and form part of this section.

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF GABIONS

APPENDIX 5: CONSTRUCTION CHECKLISTS

Design Manual. Welded Wire Mesh Gabions and Gabion Mattress

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF GABIONS

B512 - GABIONS - OPSS 512

CAPRICORN MUNICIPAL DEVELOPMENT GUIDELINES

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

PVC COATED Welded steel wire mesh

CHAPTER 15 - GABIONS, EROSION PROTECTION

CONSTRUCTION SPECIFICATION FOR CHAIN LINK FENCE

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

Redi Rock Specification and Installation Manual

MagnumStone Specifications Gravity

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

Strengthened Soil Wall Construction Manual

gab QUADRO INSTRUCTION

SENTINEL BARRIER - GENERAL INSTALLATION GUIDELINES

Special Provision No. 541S01 October OPSS 541, Construction Specifications for Chain Link Fence, is deleted and replaced with the following:

Steps And Stairs Installation Steps In Wall - Option 1 Steps In Front of Walls - Option 2 Steps In Wall; 10 (25cm) Tread - Option 3 Step Parallel to

Steps And Stairs Installation Option 1 - Steps In Wall Option 2 - Steps With Plant Space Option 3 - Steps In Front of Walls Option 4 - Steps Along

2018 Intertape Polymer Group GEOSYNTHETIC RAIN COVER INSTALLATION GUIDE

MODULO GEOBENT Installation Guidelines

SECTION 1208 CHAIN LINK FENCING DESCRIPTION

APPLICABILITY OF COMPOSITE SOIL REINFORCEMENT SYSTEM WALLS FOR HIGH RETAINING STRUCTURES.

INS T A LLA T I O N G U I D E

TABLE OF CONTENTS

CONSTRUCTION SPECIFICATION FOR STANDARD HIGHWAY FENCE

DRIVABLE GRASS GUIDELINE FOR NON PLANTED DRY INFILL INSTALLATIONS

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

A.2.a Random Riprap... Table

UPRR INDUSTRIAL LEAD BRIDGE T-WALL RETAINING WALL SYSTEM 5.0 x 7.5 UNITS DESIGN UNIT 018 WORK PACKAGE 04

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

T-WALL Retaining Wall System

ITEM 432 RIPRAP. Dry Riprap is defined as Stone Riprap of the required type with voids filled only with spalls or small stones.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Standards for Soil Erosion and Sediment Control in New Jersey May 2012 STANDARD FOR RIPRAP. Conditions Where Practice Applies

GUIDELINE FOR PLANTED INFILL INSTALLATIONS. Please read prior to installation, and have proper equipment and safety precautions in place.

Riprap must be placed uniformly and carefully to eliminate any weak area where erosion can get a start.

DRIVABLE GRASS GUIDELINE FOR DRIVABLE TURF INSTALLATION

CONCRETE WALKS AND CURBS SECTION CONCRETE WALKS AND CURBS PART 1 - GENERAL

BENTONITE WATERPROOFING

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Embankments Gabions and Mattresses Ceranablok Redi-rock Cellular Confinement Rock Fall Protection Rockmat Rabbit / Badger Netting

CONSTRUCTION SPECIFICATION FOR STANDARD HIGHWAY FENCE

SECTION MECHANICALLY STABILIZED EARTH RETAINING WALLS

SECTION CHAIN LINK FENCES

SECTION CURB, COMBINATION CURB AND GUTTER, AND MONOLITHIC MEDIAN. 1. Bituminous concrete pavement; Section

SECTION 44 SHOTCRETE, CAST CONCRETE CHANNEL LINING, AND GROUTED COBBLE TABLE OF CONTENTS

SECTION 44 SHOTCRETE, CAST CONCRETE CHANNEL LINING, AND GROUTED COBBLE TABLE OF CONTENTS

Table of Contents > The Triton Coastal & Waterway Systems are a durable, non-corrosive solution to many coastal and inland waterway erosion issues.

SECTION 44 SHOTCRETE, CAST CONCRETE CHANNEL LINING, AND GROUTED COBBLE TABLE OF CONTENTS

CONSTRUCTION SPECIFICATION FOR STANDARD HIGHWAY FENCE

GEOSYTHETIC SLOPE SPEC-V0704rev.doc STANDARD SPECIAL PROVISION FOR GEOSYNTHETIC REINFORCED SLOPE CONSTRUCTION

A. Section includes temporary excavation support and protection systems.

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

SECTION CHAIN LINK FENCES AND GATES (PARK)

Design and Installation Guidelines for Retaining Walls. 1 P age. Geo Products, LLC 8615 Golden Spike Lane Houston, TX Phone:

INTRODUCTION FEATURES DESIGN AND SPECIFICATION A. PROFESSIONAL DESIGN

Construction Procedures

TENAX TT MONO-ORIENTED HDPE GEOGRID

Earth Retaining Walls CIVL455 CHAPTER I: INTRODUCTION

Gravity Wall. A force to be reckoned with... Gravity (SRW) segmental retaining wall systems are structures

Retaining Wall System

ARMOR-BLOCK. Installation guide. Installation Manual: ARMOR-BLOCK Retaining Wall System. Cap Block. Exposed void for planting.

CASE STUDY SERIES #14

SOLID WALL PVC SEWER PIPE

Installation Manual. ArchCast Bridge. 3-Sided Precast Concrete Bridge Structure

How To Construct a Ferro Cement Tank

SOLID WALL PVC SEWER PIPE

ITEM 750 ROCK FILTER DAMS

Design & Detail Installation Manual. LongSpan Bridge and Culvert Construction System

G R A V I T Y / G E O G R I D

Miller Collective Safety at Height Solutions EPIC ULTRA Barrier System EPIC Post-N-Barrier System EPIC Basic Barrier System

CONCRETE RETAINING BLOCK WALLS

Five Stone System. Trench Depth Compactible Rock. Foundation. 57 lbs 41 lbs 31 lbs 47 lbs. Patent Pending. Approximate Weight

Technical Notes 11B - Guide Specifications for Brick Masonry, Part 3 Rev [Feb. 1972] (Reissued Sept. 1988) INTRODUCTION

Section ( ) SPECIFICATION FOR SEGMENTAL CONCRETE UNIT RETAINING WALL

LINK MIDDLE EAST (LME) EARTH RETENTION AND PROTECTION SYSTEMS LME WELDED MESH GABION BOXES AND MATTRESSES

Architectural Roof and Wall Products Guide Specifications

CONSTRUCTION SPECIFICATION FOR STANDARD HIGHWAY FENCE

Specification Lightning Protection Systems

PHYSICAL BARRIERS MACHINE GUARDS ROBOTIC WORK CELLS PERIMETER OR AREAS GUARDS PHYSICAL BARRIERS

ENGINEERING DIRECTIVE

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

Garden WallScape Installation Guide

CONSTRUCTION SPECIFICATION FOR CONCRETE SIDEWALK AND CONCRETE RAISED MEDIAN INDEX TS SCOPE...3 TS DEFINITIONS...3

Metal Scaffolds. (1) Metal scaffolds shall be designed to support all dead, live, and wind loads to which they will be subjected.

Hobby Parking Office HOU/ Proj./ No. 738 Houston, Texas 100% Bid and Construction Documents- Addendum #3, January 27, 2017

NOVEMBER 2016 MAGNUMSTONE. retaining walls installation manual

Hardscaping Installation Manual

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

CONSTRUCTION MANUAL. T-WALL Retaining Wall System FOR RAILROAD PROJECTS. The T-WALL Solution...

Transcription:

Assembly Open the bundle and unfold each unit. Lift the sides, the ends and the diaphragms of each unit into vertical position. Attach the sides of four corners together with locking wire fastener or lacing wire and the diaphragms to the front and back of the gabion. Click on image to enlarge. Installation and Filling Empty gabion baskets shall be assembled individually and placed on the approved surface to the lines and grades as shown or as directed, with the position of all creases and that the tops of all sides are level. All gabion baskets shall be properly staggered horizontally and vertically as shown in the construction drawings. Finished gabion structures shall have no gaps along the perimeter of the contact surfaces between adjoining units. All adjoining empty gabion units shall be connected along the perimeter of their contact surfaces in order to obtain a monolithic structure. All lacing wire terminals shall be securely fastened. All joining shall be made through selvedge-selvedge or selvedge-edge wire connection; mesh-mesh wire connection is prohibited except in the case where baskets are offset or stacked and selvedge-mesh or mesh-mesh wire connection would be necessary. As a minimum, a fastener shall be installed at each mesh opening at the location where mesh wire meets selvedge or edge wire.

a. The initial line of gabion basket units shall be placed on the prepared filter layer surface and adjoining empty baskets set to line and grade, and common sides with adjacent units thoroughly laced or fastened. They shall be placed in a manner to remove any kinks or bends in the mesh and to uniform alignment. The basket units then shall be partially filled to provide anchorage against deformation and displacement during the filling operation. The stone shall be placed in the units as specified or directed by the manufacturer. b. Deformation and bulging of the gabion units, especially on the wall face, shall be corrected prior to additional stone filling. Care shall be taken, when placing the stone by hand or machine, to assure that the PVC coating on the gabions will not be damaged if PVC is utilized. All stone on the exposed face shall be hand placed to ensure a neat compact appearance. c. Gabions shall be uniformly overfilled by about 1-3 inches to account for future structural settlements and for additional layers. Gabions can be filled by any kind of earth filling equipment. The maximum height from which the stones may be dropped into the baskets shall be 3'. Gabion stone placement, When excavation and foundation preparation are completed, the pre-assembled gabions shall be placed in their proper location according to the plans provided. Gabions shall then be connected together and aligned prior to filling with stone. The stone fill shall have a gradation as listed or specified within the contract specifications or as listed within this specification. The stone fill shall be placed into the gabion units in 1' lifts. Cells shall be filled to a depth not exceeding 1' at a time. The fill layer should never be more than 1' higher then any adjoining cell. Connecting wires shall be installed from the front to back and side to side of the individual cells at each 1' vertical interval for gabions with a depth of 3'. The voids shall be minimized by using well graded stone fill and by hand placement of the facing in order to achieve a dense, compact stone fill. All corners shall be securely connected to the adjoining basket of the same layer before filing the units. When more than one layer of gabions is required, in order for the individual units to become incorporated into one continuous structure, the next layer of gabions shall be connected to the layer underneath after this layer has been securely closed. Gabions shall be uniformly overfilled by about 1-2 inches to account for structural settlement. Lid Closing: The lids of the gabion units shall be tightly secured along all edges, ends and diaphragms in the same manner as described for assembling. Adjacent lids may be securely attached at the same time. The panel edges shall be pulled to be connected using the appropriate closing tools where necessary. Single point leverage tools, such as crowbars will not be acceptable. All end wire shall then be turned in.

Installation Information - Reno Mattress Simple Steps to Mattress Construction For easy handling and shipping, Mattresses are supplied folded flat in bundles of 25. Lids are packaged in separate bundles or in rolls for larger units of Mattresses. Step One Individual Mattress is first unfolded on flat, hard ground and stamped to remove all kinks. The two long sides and both end panels are then lifted upright and secured in position by tying the selvedge wires together. Step Two The vertical edges of all internal diaphragms are attached to the sides and laced with typing wire or approved interlocking wire fastener. Step Three The assembled Mattress is then aligned in the required position and tied or fastened to adjacent mattress along the whole length of

selvedge wire. Mattress units should be placed in proper position so that movement of rock fill inside the cage -- due to gravity or flowing current -- is minimal. Thus, on slopes, Mattresses should be placed with its internal diaphragms at right angles to the direction of the slope. On river beds, position Mattress with the internal diaphragms at right angles to the direction flow. Step Four Next, the stone is placed into the compartments (cells). If it's a slope, start from the bottom. One or more Mattresses can be filled at the same time. Sequence the installation by keeping the stone filling crew well ahead of the lid placement crew. Lids or top panels must be securely tied or fastened to side-tops and end panels and also to the top of the inner partitions. Step Five Step Six The Mattresses may be either telescoped or cut to form and tied at required shape when necessary, e.g. when Mattresses are laid on a radius. For a sharp curve, it may be necessary to cut the Mattress diagonally into triangular sections and tie the open side securely to an intact side panel.