DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

Similar documents
DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ELASTOCHEM SPECIALTY CHEMICALS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: SPRAY FOAM POLYMERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION DIVISION: AIR BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THERMOSEAL LLC EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER: DAP FOAM, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

ICC-ES Evaluation Report. ESR-3102 Reissued July 1, 2013 This report is subject to renewal August 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

ESR-2600 Reissued February 1, 2011 This report is subject to re-examination in two years.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Trusted DIVISION: 07 SYSTEM. Conformity! ICC-ES Evaluation. not specifically. Copyright 2014

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Originally Issued: 04/17/2015 Valid Through: 04/30/2016

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BAYER MATERIALSCIENCE, LLC

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: 07- THERMAL AND MOISTURE PROTECTION Section: Thermal Insulation REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC. EVALUATION SUBJECT:

Originally Issued: 2/12/2016 Revised: 07/28/2017 Valid Through: 2/28/2018

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: JOHNS MANVILLE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: TERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

ICC-ES Evaluation Report Reissued February 1, 2011 This report is subject to re-examination in one year.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Intertek Research Report IRR-1011

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: SES FOAM

ICC-ES Evaluation Report Reissued February 1, 2012 This report is subject to renewal February 1, 2013.

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Originally Issued: 11/06/2017 Valid Through: 11/30/2018

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

ICC-ES Evaluation Report. ESR-1154 Reissued July 1, 2012 This report is subject to renewal September 1, 2014.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: TERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

Originally Issued: 02/01/2019 Valid Through: 02/28/2020

Originally Issued: 08/03/2017 Revised: 02/01/2019 Valid Through: 08/31/2019

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Originally Issued: 03/28/2014 Revised: 05/25/2017 Valid Through: 03/31/2018

REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT: MASTERSEAL AWB 660 I VAPOR RETARDER, AIR AND WATER-RESISTIVE BARRIER AND FLEXIBLE FLASHING

Originally Issued: 07/2009 Revised: 09/30/2014 Valid Through: 07/2015

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC. EVALUATION SUBJECT:

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: APPLIED FIREPROOFING REPORT HOLDER: FLAMEOFF COATINGS, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES EVALUATION SUBJECT:

Trusted ICC ES DIVISION: 07 LTD. PLASTI FAB CANADAA PLASTISPAN. Look. Conformity! Evaluation. ICC-ES Evaluation

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

REPORT HOLDER: GEORGIA PACIFIC GYPSUM LLC 2861 MILLER ROAD DECATUR, GEORGIA EVALUATION SUBJECT: DENSELEMENT BARRIER SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT:

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD FLAPS, LLC

Code Compliance Research Report CCRR-1043

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

ESR-1061 Reissued May 1, 2011 This report is subject to renewal in two years.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: REFLECTIX INCORPORATED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD FLAPS, LLC EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: HB&G BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: TEJAS BORJA USA EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: FIRE RETARDANT COATINGS REPORT HOLDER: FIRE RETARDANT COATINGS OF TEXAS, LLC

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING REPORT HOLDER: SILCA SYSTEM

Originally Issued: 07/31/2015 Revised: 07/31/2017 Valid Through: 07/31/ General

Originally Issued: 07/06/2009 Revised: 04/07/2017 Valid Through: 07/31/2017

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: EQUITONE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: APPLIED FIREPROOFING REPORT HOLDER: ISOLATEK INTERNATIONAL

Bayseal Wall Insulation for Commercial Building Envelope Insulation Specification

Transcription:

0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3136 Reissued 06/2017 This report is subject to renewal 06/2018. DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00 THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC 4N 325 POWIS ROAD WEST CHICAGO, ILLINOIS 60185 EVALUATION SUBJECT: NATURAL-THERM 0.50 PCF, NU-SEAL 0.50 PCF, NATURAL-THERM 2.0 W PCF AND NU-SEAL 2.0 W PCF SPRAY-APPLIED POLYURETHANE FOAM INSULATION Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report ESR-3136 Reissued June 2017 Revised October 2017 This report is subject to renewal June 2018. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 21 00 Thermal Insulation REPORT HOLDER: NATURAL POLYMERS, LLC 4N 325 POWIS ROAD WEST CHICAGO, ILLINOIS 60185 (630) 587-0718 www.naturalpolymersllc.com ADDITIONAL LISTEE: NU-WOOL COMPANY INCORPORATED 2472 PORT SHELDON STREET JENISON, MICHIGAN 49428 www.nuwool.com EVALUATION SUBJECT: NATURAL-THERM 0.50 PCF, NU-SEAL 0.50 PCF, NATURAL-THERM 2.0 W PCF AND NU-SEAL 2.0 W PCF SPRAY-APPLIED POLYURETHANE FOAM INSULATION 1.0 EVALUATION SCOPE 1.1 Compliance with the following codes: 2012 and 2009 International Building Code (IBC) 2012 and 2009 International Residential Code (IRC) 2012 and 2009 International Energy Conservation Code (IECC) Properties evaluated: Surface-burning characteristics Physical properties Thermal resistance (R-values) Attic and crawl space installations Water vapor transmission (2.0 W PCF only) Air permeability (0.50 PCF only) 1.2 Evaluation to the following green standard: 2008 ICC 700 National Green Building Standard (ICC 700-2008) Attributes verified: See Section 3.1 2.0 USES PCF spray-applied polyurethane foam insulations are used as nonstructural thermal insulating material in Type V-B construction under the IBC and in dwellings under the IRC. The insulations are for use in wall cavities, floor assemblies or ceiling assemblies, or in attic and crawl spaces when installed in accordance with Section 4.0. Nu-Seal 0.50 PCF foam insulation is identical to Natural-Therm 0.50 PCF foam insulation and may be used and installed in the same manner as Natural- Therm 0.50 PCF foam insulation. Nu-Seal 2.0 W PCF foam insulation is identical to Natural-Therm 2.0 W PCF foam insulation and may be used and installed in the same manner as Natural-Therm 2.0 W PCF foam insulation 3.0 DESCRIPTION 3.1 Materials: Natural-Therm 0.50 PCF spray-applied foam insulation is an open-cell, low-density, spray-applied, polyurethane foam plastic. The insulation is a two-component spray foam plastic with a nominal in-place density of 0.5 pcf (8 kg/m 3 ). The insulation is produced in the field by combining a polymeric isocyanate (A component) and a polymeric resin (B component). The insulation liquid components are supplied in 55-gallon (208 L) drums and must be stored at temperatures between 45 F and 90 F (7 C and 32 C). The liquid components have a shelf life of one year when stored in factory-sealed containers at these temperatures. Natural-Therm 2.0 W PCF spray-applied foam insulation is a closed-cell, medium-density, spray-applied, polyurethane foam plastic. The insulation is a twocomponent spray foam plastic with a nominal in-place density of 2.0 pcf (32 kg/m 3 ). The insulation is produced in the field by combining a polymeric isocyanate (A component) and a polymeric resin (B component). The insulation liquid components are supplied in 55-gallon (208 L) drums and must be stored at temperatures between 45 F and 90 F (7 C and 32 C). The liquid components have a shelf life of one year when stored in factory-sealed containers at these temperatures. The attributes of the insulations have been verified as conforming to the provisions of ICC 700-2008 Section 703.2.1.1.1(c) as an air impermeable insulation. Note that decisions on compliance for those areas rest with the user of this report. The user is advised of the project-specific ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 5

ESR-3136 Most Widely Accepted and Trusted Page 2 of 5 provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this report. These codes or standards often provide supplemental information as guidance. 3.2 Surface-burning Characteristics: The Natural-Therm 0.50 PCF insulation, at a maximum thickness of 5 5 / 8 inches (143 mm) and a nominal density of 0.5 pcf (8 kg/m 3 ) has a flame-spread index of 25 or less and smoke-developed index of 450 or less when tested in accordance with ASTM E84 (UL 723). There is no thickness limit when installation is behind a codeprescribed 15-minute thermal barrier, except as noted in Section 4.4.3. The Natural-Therm 2.0 W PCF insulation, at a maximum thickness of 4.0 inches (102 mm) and a nominal density of 2.0 pcf (32 kg/m 3 ), has a flame-spread index of 25 or less and smoke-developed index of 450 or less when tested in accordance with ASTM E84 (UL 723). There is no thickness limit when installation is behind a codeprescribed 15-minute thermal barrier, except as noted in Section 4.4.3. 3.3 Thermal Resistance (R-values): PCF spray-applied foam insulations have thermal resistance (R-values) at a mean temperature of 75 F (24 C) as shown in Table 1. 3.4 Air Permeability: Natural-Therm 0.50 PCF at a minimum thickness of 3.5 inches (89 mm) is considered air-impermeable insulation in accordance with 2012 IRC Section R806.4 [2009 IRC Section R806.4], based on testing in accordance with ASTM E283. 3.5 Water Vapor Transmission: At a minimum thickness of 1.0 inches (25.4 mm), Natural- Therm 2.0 W PCF insulation has a vapor permeance of less than 1.0 perms [5.7x10-8 kg/(pa-s-m 2 )], when tested in accordance with the ASTM E96 desiccant method (Procedure A), and qualifies as Class II vapor retarder. 3.6 FoamKote FC 50-50A: FoamKote FC 50-50A intumescent coating, manufactured by Flame Control Coatings, LLC, is a one-component, water-based liquid coating. FoamKote FC 50-50A is supplied in 1-gallon (4 L) and 5-gallon (19 L) pails and has a shelf life of nine months when stored in factory-sealed containers at temperatures between 50 F and 90 F (10 and 32 C). 3.7 DC 315 Coating: DC 315 Coating is manufactured by International Fireproof Technology, Inc., and is water-based latex intumescent coating supplied in 55-gallon (208 L) drums. The coating has a shelf life of one year when stored in a factory-sealed container at temperatures between 50 F and 80 F (10 C and 26.7 C). 4.0 INSTALLATION 4.1 General: PCF spray-applied foam insulations must be installed in accordance with the manufacturer s published installation instructions and this report. The manufacturer s published instructions and this report must be strictly adhered to, and a copy of this report and the manufacturer s published installation instructions must be available at all times on the jobsite during installation. 4.2 Application: The insulation is spray-applied on the jobsite using a volumetric positive displacement pump as identified in the Natural Polymers, LLC's, application manual. The insulation is applied in multiple passes having a maximum thickness of 6 inches (152 mm) per pass for Natural- Therm 0.50 PCF or a maximum thickness per pass of 2 inches (50.8 mm) for Natural-Therm 2.0 W PCF up to the maximum insulation thicknesses specified in this report. The insulation components must be stored at temperatures between 50 F and 90 F (10 and 32 C). The insulation must not be used in areas that have a maximum in-service temperature greater than 180 F (82 C). The foam plastic must not be used in electrical outlet or junction boxes or in contact with rain, water, or soil. The foam plastic must not be sprayed onto a substrate that is wet, or covered with frost or ice, loose scales, rust, oil, or grease. The insulation must be protected from the weather during and after application. 4.3 Application with a Prescriptive Thermal Barrier: PCF spray-applied foam insulation must be separated from the interior of the building by an approved thermal barrier of 1 / 2-inch-thick (12.7 mm) gypsum wallboard or an equivalent 15-minute thermal barrier complying with, and installed in accordance with, IBC Section 2603.4 or IRC Section R316.4, as applicable, except where installation is in an attic or crawl space as described in Section 4.4.2. There is no thickness limit when installation is behind a code-prescribed 15-minute thermal barrier, except as noted in Section 4.4.3. 4.4 Attics and Crawl Spaces: 4.4.1 Application with a Prescriptive Ignition Barrier: When Natural-Therm 0.50 PCF and 2.0 W PCF sprayapplied foam insulation is installed within attics or crawl spaces, where entry is made only for service of utilities, an ignition barrier must be installed in accordance with IBC Section 2603.4.1.6 or IRC Sections R316.5.3 and R316.5.4, as applicable, except where the installation is in accordance with Section 4.4.2. The ignition barrier must be consistent with the requirements of the type of construction required by the applicable code, and must be installed in a manner such that the foam plastic insulation is not exposed. 4.4.2 Application without a Prescriptive Ignition Barrier: 4.4.2.1 General: When Natural-Therm 0.50 PCF and Natural-Therm 2.0 W PCF spray-applied foam insulation is installed without a prescriptive ignition barrier in attics and crawl spaces, in accordance with Sections 4.4.2.2 and 4.4.3, the following conditions apply: a. Entry to the attic or crawl space is only to service utilities and no storage is permitted. b. There are no interconnected attic or crawl space areas. c. Air in the attic or crawl space is not circulated to other parts of the building. d. Under-floor (crawl-space) ventilation is provided in accordance with IBC Section 1203.3 or IRC Section R408.1, as applicable. e. Attic ventilation is provided in accordance with IBC Section 1203.2 or IRC Section R806, as applicable.

ESR-3136 Most Widely Accepted and Trusted Page 3 of 5 f. Combustion air is provided in accordance with IMC (International Mechanical Code ) Section 701. In attics, Natural-Therm 0.50 PCF and Natural- Therm 2.0 W PCF insulation may be spray-applied to the underside of roof sheathing or roof rafters, and/or vertical surfaces and, in crawl spaces, the insulation may be sprayapplied to the underside of floors and/or vertical surfaces as described in this section. The thickness of the Natural- Therm 0.50 PCF applied to the underside of the top of the space must not exceed 10 inches (254 mm). The thickness of the Natural-Therm 0.50 PCF applied to vertical surfaces must not exceed 8 inches (203 mm). The thickness of the Natural-Therm 2.0 W PCF applied to the underside of the top of the space must not exceed 11 1 / 4 inches (286 mm). The thickness of the Natural- Therm 2.0 W PCF applied to vertical surfaces must not exceed 11 1 / 4 inches (286 mm). The foam plastic may be installed without a covering or coating. The insulation may be installed in unvented attics in accordance with 2012 IRC Section R806.5 (2009 IRC Section R806.4). The ignition barrier in accordance with IBC Section 2603.4.1.6 or IRC Section R316.5.3 may be omitted. 4.4.2.2 Application with FoamKote FC 50-50A Intumescent Coating: In attics, Natural-Therm 0.50 PCF and Natural-Therm 2.0 W PCF foam insulation may be spray-applied to the underside of the roof sheathing and/or rafters; and, in crawl spaces, to the underside of wood floors and/or floor joists as described in this section. The thickness of the Natural-Therm 0.5 PCF foam plastic applied to the underside of the top of the space must not exceed 12 inches (305 mm). The thickness of the Natural-Therm 0.5 PCF spray foam insulation applied to vertical wall surfaces in attics and crawl spaces must not exceed 8 inches (203 mm). The thickness of the Natural- Therm 2.0 W PCF foam plastic applied to the underside of the top of the space must not exceed 11.5 inches (292 mm). The thickness of the Natural-Therm 2.0 W PCF spray foam insulation applied to vertical wall surfaces in attics and crawl spaces must not exceed 7.5 inches (191 mm). The foam plastic insulation must be covered with a minimum nominally 10-mil (0.25 mm) wet film [7.5 mils (0.19 mm) dry film] thickness of the FoamKote FC 50-50A described in Section 3.5, applied over the insulation in accordance with the coating manufacturer s instructions and this report. The coating is applied in one or two coats by an airless sprayer, brush or roller at a rate of either 1 gallon per 100 square feet (0.41 L/m 2 ) in one coat or 1 / 2 gallon per 100 square feet (0.41 L/m 2 ) per coat in two coats, to obtain the required minimum thickness of 10-mil (0.25 mm) wet film [7.5 mils (0.19 mm) dry film]. The coating has a minimum four-hour curing time per coat. The coating must be applied to surfaces that are dry, clean, and free of dirt, loose debris and any other substances that could interfere with adhesion of the coating, and when ambient and substrate temperatures are within a range of 50 F (10 C) to 90 F (32 C). 4.4.2.3 Application with DC 315 Coating: : In attics, PCF foam insulation may be spray-applied to the underside of roof sheathing or roof rafters, and/or to vertical surfaces. In crawl spaces, the insulation may be spray-applied to the underside of the floors and/or vertical surfaces. The thickness of the Natural-Therm 0.50 PCF foam plastic applied to the underside of the top of the space must not exceed 10 inches (254 mm). The thickness of the Natural-Therm 0.50 PCF spray foam insulation applied to vertical wall surfaces in attics and crawl spaces must not exceed 8 inches (203 mm). The thickness of Natural-Therm 2.0 W PCF spray foam insulation applied to the underside of the top of the space and to vertical wall surfaces in attics and crawl spaces must not exceed 11 1 / 4 inches (286 mm). Natural-Therm 0.50 PCF must be covered on all exposed surfaces with DC315 coating, described in Section 3.6, at a minimum wet film thickness of 20 mils (0.51 mm) [14 dry mils (0.36 mm)]. Natural- Therm 2.0W PCF must be covered on all exposed surface with DC 315 intumescent coating at a minimum wet film thickness of 21 mils (0.53 mm) [14 dry mils (0.36 mm)]. The DC 315 intumescent coating must be applied over Natural-Therm 0.50 PCF insulation in accordance with the manufacturer s instructions and this report. Surfaces to be coated must be dry, clean, and free of dirt loose debris and any other substance that could interfere with adhesion of the coating. The coating must be applied when ambient and substrate temperatures are a minimum of 50 F (10 C). 4.4.3 Use on Attic Floors: Natural-Therm 0.50 PCF spray-applied foam insulation may be installed at a maximum thickness of 8 inches (203 mm) between joists on attic floors. Natural-Therm 2.0 W PCF spray-applied foam insulation may be installed at a maximum thickness of 7.5 inches (191 mm) between joists on attic floors. The Natural-Therm spray-applied foam insulation must be separated from the interior of the building by an approved thermal barrier, and separated from the attic space with FoamKote FC 50-50A coating as described in Section 4.4.2.2. The ignition barrier in accordance with IBC Section 2603.4.1.6 and IRC Section R316.5.3 may be omitted. 5.0 CONDITIONS OF USE The Natural-Therm 0.50 PCF and Natural-Therm 2.0 W PCF spray-applied foam insulations described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The insulations must be installed in accordance with the manufacturer s published installation instructions, this evaluation report and the applicable code. If there are any conflicts between the manufacturer s published installation instructions and this report, this report governs. 5.2 The insulations must be separated from the interior of the building by an approved 15-minute thermal barrier, in accordance with Section 4.3. 5.3 The insulations must not exceed the nominal density and thicknesses noted in Sections 3.2, 4.3 and 4.4 of this report. 5.4 The insulations must be protected from exposure to weather during and after application. 5.5 The insulations must be applied by contractors certified by Natural Polymers, LLC. 5.6 Use of the insulation in areas where the probability of termite infestation is very heavy must be in accordance with IBC Section 2603.8 or IRC Section 318.4, as applicable. 5.7 The insulations have been evaluated only for use in Type V-B construction under the IBC and dwellings under the IRC. 5.8 A vapor retarder must be installed when required by the applicable code. 5.9 Jobsite certification and labeling of the insulation must comply with IRC Sections N1101.4 and N1101.4.1 and IECC Sections 303.1.1 and 303.1.2, as applicable. 5.10 The insulations produced in West Chicago, Illinois, under a quality control program with inspections by ICC-ES.

ESR-3136 Most Widely Accepted and Trusted Page 4 of 5 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Spray-applied Foam Plastic Insulation (AC377), dated April 2016, including reports of tests in accordance with Appendix X of AC377. 6.2 Reports of room corner tests in accordance with NFPA 286 for Natural-Therm 0.5 PCF. 6.3 Reports of water vapor transmission test for Natural- Therm 2.0 W PCF in accordance with ASTM E96. 6.4 Reports of air leakage tests for Natural-Therm 0.50 PCF in accordance with ASTM E283. 7.0 IDENTIFICATION Components of the spray foam insulation are identified with the manufacturer s name (Natural Polymers, LLC) or listee s name (Nu-Wool Company, Inc.), address and telephone number; the product trade name (Natural- Therm or Nu-Seal ); use instructions; the density; the flame-spread and smoke-development indices; the date of manufacture; thermal resistance values; the evaluation report number (ESR-3136). THICKNESS (inches) TABLE 1 THERMAL RESISTANCE (R-VALUES) NATURAL-THERM 0.50 PCF OR NU-SEAL 0.50 PCF R-VALUE ( f ft 2 h/btu) NATURAL-THERM 2.0 W PCF OR NU-SEAL 2.0 W PCF R-VALUE ( f ft 2 h/btu) 1 3.7 6.7 2 7.5 13 3.5 13 21 4 15 24 5 19 30 5.5 20 33 6 22 36 7 26 42 7.5 28 45 8 30 47 9 33 53 9.5 35 56 10 37 59 11.5 43 68 12 44 71 For SI: 1 inch = 25.4 mm, 1 F ft 2 h/btu = 0.176 110 K m 2 /W. 1 R-Values are calculated based on tested K values at 1-inch and 4-inch thicknesses for Natural-Therm 0.50 PCF. 2 R-Values are calculated based on tested R values at 1-inch and 4-inch thicknesses for Natural-Therm 2.0 W PCF.

ICC-ES Evaluation Report www.icc-es. org (800) 423-6587 ESR-3136 FBC Supplement Reissued June 2017 This report is subject to renewal June 2018. (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 21 00 Thermal Insulation REPORT HOLDER: NATURAL POLYMERS, LLC 4N 325 POWIS ROAD WEST CHICAGO, ILLINOIS 60185 ( 630) 587-07188 www.naturalpolymersllc.comm EVALUATION SUBJECT: NATURAL-THERM 0.50 PCF, NU-SEAL 0.50 PCF, NATURAL-THERM 2.0 W PCF AND NU-SEAL 2.0 W PCF SPRAY-APPLIED POLYURETHANE FOAM INSULATIONN 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Natural-Therm 0..50 PCF, Natural-Therm 2.0 W PCF and Nu-Seal 0.500 PCF polyurethane foam insulation, recognized in ICC-ES master report ESR-3136, have also been evaluated for compliance with the codes noted below. Applicable code editions: 2010 Florida Building Code Building 2010 Florida Building Code Residential 2.0 CONCLUSIONS The polyurethane foam insulations, described in Sections 2.0 through 7.0 of the master evaluation report ESR-3136, comply with the 20100 Florida Building Code Building and the 2010 Florida Building Code Residential, provided the design and installation are in accordance with the International Building Code provisions noted in the master report. Use of the Natural-Therm 0.50 PCF, Nu-Seal 0.5 PCF, Natural-Therm 2.0 W PCF and Nu-Seal 2.0 W PCF polyurethane foam insulation, for compliance with the High-Velocity Hurricane Zone provisionss of the 2010 Florida Building Code Building and the 2010 Florida Building Code Residential has not beenn evaluated, and is outside the scope of this evaluation report. For products falling under Florida Rule 9N-3, verification that the report holder s quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspectionss being conducted is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued June 2017 and revised October 2017. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty byy ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 5 of 5