SPECIFICATION SECTION : FIRE RATED GLASS PYRAN Platinum min. Fire Rated Ceramic Glass

Similar documents
SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING PYRAN Platinum F min. Fire Rated Filmed Ceramic Glass

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Architectural Series Framing

SPECIFICATION SECTION : GLASS FLOORING & FRAMING GPX FireFloor System (Patented)

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Hurricane System

Thickness Weight Max. Impact Hose in. (mm) lbs/ft 2 Appearance Sheet Size Surface Safety-rated Stream Test

SCHOTT PYRAN Platinum Product Information

.2 Section Waste Management and Disposal.

Repair Maintenance Hangar Phase II August 2010

SECTION GLAZING ADDENDUM 10 APRIL 20, 2011

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Pyrobel 45. Maximum Glazing Sizes (ClearView)

SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

Alabama A&M University Laundry Building at Normal Hill Apartments Project No ADDENDUM NUMBER 4

ARCH 478 OFFICE BUILDING SECTION GLAZING

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

SECTION DECORATIVE GLASS GLAZING. A. Decorative specialty glass glazing for interior applications, including:

2004 MASTER FORMAT SECTION Façade Panels

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

Design No. U553 BXUV.U553 Fire-resistance Ratings - ANSI/UL 263. Design No. U553

SECTION GLAZING

LISTING REPORT - MANUFACTURING Issued: Oct :12AM. Inspection Tests And Evaluation Of

SECTION FIBERGLASS REINFORCED PLASTIC (FRP) DOORS AND FIBERGLASS RESIN TRANSFER MOLDED DOOR FRAMES

DIVISION 9 - SECTION ECOSilence Recycled Rubber Sound Underlayment US Patent No. RE 41,945

1.3 REFERENCE STANDARDS

QT 4003 (3mm), QT 4005 (5mm) & QT 4010 (10mm)

SECTIONAL OVERHEAD DOORS SECTION SECTIONAL OVERHEAD DOORS PART 1 GENERAL

Series B450 Guide Specification

Product Guide Specification Pliteq GenieMat FF06, GenieMat FF10, GenieMat FF17, GenieMat FF25, GenieMat FF50, GenieMat FF75

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

Octaform Quick Liner Wall & Ceiling Panels Guide Specification CAN Page 1

SECTION ** NOTE TO SPECIFIER ** Overhead Door Corp.; Residential Sectional Overhead Door products.

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION RESIDENTIAL OVERHEAD DOORS IMPRESSION STEEL COLLECTION STEEL DOORS 5800 SERIES

JE Berkowitz, L.P. Architectural Glazing Guide Specification for Enviroscreen Silk-Screened Glass

AMBICO Limited Section and STAINLESS STEEL DOORS AND FRAMES Page 1

ENKASONIC FLOOR UNDERLAYMENT 9110

SECTION STAINLESS STEEL WALL PANELS

PYRAN Platinum. Environmentally friendly fire-rated glass-ceramics

1. Amarco Products Athletic Recycled Rubber Sports Flooring Rolls and Interlocking Tiles 2. Adhesives

Guideline Specifications

UPOFLOOR Quartz Tile Architectural Guide Specification CSI/CSC Section Format [3-part] CSI Page Format

SECTION / / BULLET RESISTANT SOUND CONTROL WINDOWS

Guide Specifications Section

SECTION METAL WALL PANELS

.1 Blast-resistant non-fire rated pressed steel frames. .4 Factory supplied [and installed] glass and glazing.

ADDENDUM NUMBER TWO. for SWIM TEAM LOCKER ROOM RENOVATIONS REBID UNIVERSITY OF SOUTH CAROLINA COLUMBIA, SOUTH CAROLINA. DATE OF ISSUE: June 19, 2014

SECTION GLAZING

Floor Insulation Underlayment Section Sound Control Matting

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS

1.3 REFERENCE STANDARDS

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

JOB NAME SIMULATED STILE AND RAIL MDF DOORS of 8 REVISED 03/01/11 SECTION STILE AND RAIL MDF DOORS

SECTION (SOLID/ENGINEERED BAMBOO-EXTERIOR GRADE PRODUCTS)

SECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

OPACI-COAT Water-base Silicone Glass Coating

Multi-Institutional Academic Health Science & Research Center Evansville, IN

AMBICO Limited Section and ACOUSTIC STEEL DOOR AND FRAME ASSEMBLIES Page 1

1. Division 01: Administrative, procedural, and temporary work requirements.

REQUEST FOR PROPOSAL Ballistic Film

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS

AMBICO Limited 7\2018 Section and OVERSIZED METAL DOORS AND FRAMES Page 1

B. Mirror glass for toilet rooms is specified in Section "Toilet Accessories."

SILVER LINE BUILDING PRODUCTS

Series 4900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

SECTION GLASS AND GLAZING (WINDOWS)

DIVISION 9 - SECTION QTscu Re-bonded Recycled Rubber Impact Sound Insulation Patent No. RE 41,945

SECTION SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION STEEL WINDOWS UL Labeled Fire-Rated Fixed Lite (950) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

Everlast Basic Rolls and Tiles GUIDE SPECIFICATIONS Ecore

SECTION EXTERIOR GRILLS AND SCREENS

SECTION GYPSUM BOARD

SECTION GLAZING. A. Section Includes: 1. Glass for other sections referencing this Section.

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION GYPSUM BOARD ASSEMBLIES

ReCote Finish System over Concrete

FINA Stoneworks NATURAL STONE HONEYCOMB REINFORCED PANEL SYSTEM

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS

GUIDE SPECIFICATION: DUCT LINER

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

PIP ARS08111 Standard Steel Doors and Frames Supplier Specification

Series - 1

POLYCAST Trench Drain Systems

TRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT

Guide Specifications Section

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION METAL DOORS & FRAMES

AMBICO Limited Section and BLAST RESISTANT STEEL WINDOW FRAME ASSEMBLIES Page 1

Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Transcription:

This GGI Specification was prepared as an aid to specifiers preparing written construction documents. For specification assistance with specific product applications, please contact GGI. To download an electronic copy, please visit www.generalglass.com. PART 1 GENERAL 1.01 SUMMARY SPECIFICATION SECTION 08 8810: FIRE RATED GLASS PYRAN Platinum 20-90 min. Fire Rated Ceramic Glass A. Section Includes: Fire rated glazing 1. PYRAN Platinum clear fire rated ceramic glass for 20-90 minute non-safety interior and exterior applications. 2. Applications of fire rated glazing include: a. Fire rated glazing as windows or transoms in fire rated frames. B. Related Sections: 1. Section 01 3323: Shop Drawings, Product Data and Samples. 2. Section 08 5130: Steel Windows. 1.02 REFERENCES A. American Society for Testing and Materials (ASTM): 1. ASTM E2010-01 Standard Test for Positive Pressure of Fire Tests of Window Assemblies. B. National Fire Protection Association (NFPA): 1. NFPA 80: Fire Doors and Windows. 2. NFPA 257: Fire Tests of Window Assemblies. C. Underwriters Laboratories, Inc. (UL): 1. UL 9: Standard for Safety of Fire Tests of Window Assemblies. D. Standard Council of Canada (ULC): 1. ULC Standard CAN4-S106: Fire Tests of Window Assemblies. E. Glass Association of North America (GANA) 1. GANA Glazing Manual. 2. FGMA Sealant Manual. 1

F. [Insert building code used by Authority Having Jurisdiction] 1.03 SYSTEM DESCRIPTION A. Performance Requirements: Provide a fire rating glazing manufactured, fabricated and installed to maintain performance criteria stated by manufacturer without defects, damage or failure. 1. Fire Rating: PYRAN Platinum is fire rated from 20-90 minutes with hose stream and is limited to non-safety rated locations. 2. PYRAN Platinum is tested in accordance with NFPA 80, NFPA 257, UL 9, ASTM E2010-01 and CAN4-S106. 3. Testing Laboratory: Fire test shall be conducted by a nationally recognized independent testing laboratory. B. Listings and Labels: 1. Fire rated glazing shall be under current follow-up service by a nationally recognized independent testing laboratory approved by OSHA and maintain a current listing or certification. Assemblies shall be labeled in accordance with limits of listings. 1.04 SUBMITTALS A. Submit listed submittals in accordance with Conditions of the Contract and Division 1 Submittal Procedure Section. 1. Shop Drawings: Submit shop drawings showing layout, profiles and product components. 2. Samples: Submit 6x6 glass samples. 3. Technical Information: Submit latest edition of manufacturer s product data. 1.05 DELIVERY, STORAGE AND HANDLING A. General: Comply with Division 1 Product Requirements Sections. B. Ordering: Comply with manufacturer s ordering instructions and lead-time requirements to avoid construction delays. C. Delivery: Deliver materials to specified destinations in manufacturer s or distributor s packaging undamaged, complete with installation instructions. D. Storage and Protection: Store off ground, under cover, protected from weather and construction activities and at temperature conditions recommended by manufacturer. 2

1.06 PROJECT CONDITIONS A. Field Measurements: Verify actual measurements for openings by field measurements before fabrication. Show recorded measurements on shop drawings. Coordinate field measurements and fabrication schedule with construction progress to avoid construction delays. 1.07 WARRANTY A. Project Warranty: Refer to Conditions of the Contract for project warranty provisions. B. Manufacturer s Warranty: Submit, for Owner s acceptance, manufacturer s standard warranty document. Manufacturer s warranty is not intended to limit other rights that the Owner may have under the Contract Documents. 1. Warranty Period: 10 years from date of shipping. PART 2 PRODUCTS 2.01 FIRE RATED GLAZING A. Material: PYRAN Platinum 20-90 minute fire protective ceramic glass with hose stream. B. Manufacturer: PYRAN Platinum as manufactured by SCHOTT Technical Glass Solutions and distributed by GGI. Contact: 101 Venture Way, Secaucus, NJ 07094-1808; Telephone 800.431.2042; Fax 201.553.1851 ; email info@generalglass.com; Web site www.generalglass.com. C. Design Requirements: 1. Thickness: Must be 3/16 (5 mm) thick. 2. Weight: Must weigh 2.5 lbs./sq. ft. 3. Sound Transmission Rating: Must meet 31 STC. 4. Fire Rating: 20-90 minutes with hose stream. 5. Appearance: Must have neutral coloration free of amber tints. 6. Cradle to Cradle Certification: Must be C2C Silver Certified. 7. Environmental Impact: Manufacturing process and final product composition must be free from toxins or hazardous heavy metals. D. Manufacturer s Fire Rated Glazing Material: 1. Each piece of fire-rated glazing material shall be labeled with a permanent logo including name of product, manufacturer, testing laboratory and fire rating. 3

E. Substitutions: No substitutions allowed. 2.02 MATERIALS A. Glazing Accessories: Manufacturer recommended fire rated glazing accessory as follows: 1. Glazing tape: Closed cell polyvinyl chloride (PVC) foam, Pemko Manufacturing Company, Ref. FG3000S90 or Unifax Corporation Fiberfrax Alumino-Silicate fiber glazing tape. 2. Setting blocks: Calcium silicate or hardwood. 3. Cleaners, primers, sealers: Type recommended by manufacturer of glass and gaskets. 2.03 RELATED PRODUCTS A. Glazing shall be installed in an equally rated framing system. 2.04 SOURCE QUALITY A. Obtain fire rated glazing products from a single manufacturer. B. Fabrication Dimensions: Fabricate to approved dimensions. The general contractor shall guarantee dimensions where practicable within required tolerances. PART 3 EXECUTION 3.01 MANUFACTURER S INSTRUCTIONS A. Compliance: Comply with manufacturer s product data including product technical bulletins and installation instructions. 3.02 EXAMINATION A. Site Verification of Conditions: Verify substrate conditions, have been previously installed under other sections, and are acceptable for product installation in accordance with manufacturer s instructions. 3.03 INSTALLATION (GLAZING) A. Comply with referenced GANA manuals and instructions of manufacturers of glass, glazing sealants and glazing compounds. 4

B. Protect glass from edge damage during handling and installation. Inspect glass during installation and set aside pieces with edge damage that could affect performance. C. Set units of glass in each series with uniformity of pattern, draw, bow and similar characteristics. D. Cut glazing tape to length and set against permanent stops, flush with sight lines to fit openings exactly, with stretch allowance during installation. E. Arrange two setting blocks located at quarter points of glass with edge block no more than 6 inches from corners. F. Glaze vertically into labeled fire rated frames or fire rated walls with the same fire rating as the glass and push against tape for full contact at perimeter of pane or unit. G. Place glazing tape on free perimeter of glazing in same manner described above. H. Install removable stop and secure without displacing the tape. I. Install so that appropriate markings remain permanently visible. J. Field cutting or tampering is strictly prohibited. 3.04 CLEANING AND PROTECTION A. Protect glass from contact with contaminating substances resulting from construction operations. Remove such substances by method approved by manufacturer. B. Wash glass on both faces not more than four days prior to date schedule for inspections intended to establish date of Substantial Completion. Wash glass by method recommended by glass manufacturer. C. Remove temporary coverings and protection of adjacent work areas. D. Remove construction debris from project site and legally dispose of debris. 5

END OF SECTION In the interest of continuous improvement of its product line, GGI reserves the right to modify its products composition, colors, textures, sizes, and other physical and performance attributes and these guide specifications at any time. GGI makes no expressed or implied warranties regarding content, errors, or omissions in the information presented. Specifications modified or rewritten not in conformance with manufacturer s standard processes, products, and procedures may void warranties and related remedies. 6