Using a Aerosol Sealant to Reduce Multifamily Envelope Leakage

Similar documents
Aerosols - Seek and Seal Envelope Leaks

Initial House Assessments & Sealing Options:

Aerosol Envelope Sealing for Residential New Construction

Initial House Assessments & Sealing Efforts: California Builder #1

2015 IECC Air Sealing Multifamily For Code Compliance Funding for Energy Code Training

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

Commercial & Institutional HVAC Duct Leakage and Retrofit Duct Sealing

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Using an Aerosol Sealant to Reduce Multifamily Envelope Leakage

Indoor Air Quality and Mechanical Ventilation (Page 1 of 5)

2012 IECC and 2013 AEGB Rating. Jessica Galloway and John Umphress! AIA Conference! August 23, 2013!

2011 Enterprise Green Communities Criteria Checklist

Before You Start Renovating Your Bathroom

FRAMING INSPECTION GENERAL

BUILDING CODE BULLETIN

Air Sealing for 5 ACH 50

KITCHEN REMODELS CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER, MISSION VIEJO, CA (949)

Air Sealing, Infiltration & Ventilation

Presented by: Stephen Carr Regional Building Science Manager (386)

INTERIOR ENVIRONMENT

Supplement B - Taking Credit for Reduced Air Leakage in Residential Buildings

SPARTANBURG COUNTY BUILDING CODES DEPARTMENT

Village of Glen Ellyn Basement Remodeling Project Guidelines

Energy Efficiency Requirements 9.36

2. Heat Transfer is quantified in British Thermal Units (BTU s)

About Southface. Southface promotes sustainable homes, workplaces and communities through education, research, advocacy and technical assistance.

Feature Zone IECC 2009 IECC

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

ASHRAE 62.2: What s New in 2016

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

City of Millbrae 2016 CALIFORNIA GREEN BUILDING CODE CHECKLIST FOR NEW NONRESIDENTIAL BUILDINGS

A.ENVELOPE AIR SEALING

BUILDING ENCLOSURE AIR TIGHTNESS TESTING Course Number: BCLUNA018-01P

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

Commissioning of Homes

SUBMISSION GUIDE FOR ARCHITECTS

ASHRAE and Indoor Air Quality

A Performance Based ENERGY STAR Homes Program: The Wisconsin ENERGY STAR Homes Perspective

IRC 2012 Key Changes

SOUTHWEST ENERGY CODES CONFERENCE. This is how we do it! Getting to 3ACH50 and

LEED for Homes Approved ID Request:

Residential Basement Finish Guide

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

Michigan Energy Code Training and Implementation Program

ASHRAE 62.2: What s New in 2016

SUSTAINABLE ENERGY ANALYTICS

2014 British Columbia Building Code Changes

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

Hardin County Planning and Development Commission

Informed Mechanical Design Through Tested Air Leakage Rates

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

Typical Finished Basement Details

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior

Overview of Presentation. Airflow Control: Why. Airflow Control: what kind?

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Permit Posting and Inspection Procedures

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

Evergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program

Minimum Requirements for Residential Occupancy Codes and FAQs

Mark Lawton, P.Eng., FEC. Airtightness in Buildings A Canadian History June 2017

A, B, C, D VENTILATION SYSTEMS: COMPARISON

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

Reducing Air Leakage Through Envelope Retrofits: Does Your Building Suck?

MID-CONSTRUCTION BLOWER DOOR TESTING February 15, 2017

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

2018 IRC Sections R303 through R310 Building Planning II

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

Inspection Report. Property Address:

NAHB s Recommendations on Critical 2015 ICC Code Change Proposals

burnsville green guide green remodeling strategies to save you money while improving your health and reducing the environmental impacts of your home

Tuning up the envelope of your building

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

County of Yolo Development Services Building Inspection Division

Low-cost Construction for High-energy Savings. Brian J. Wimmer Construction Manager Rochester Area Habitat for Humanity

Homes Across Nebraska Are Being Built to the Latest National Energy Standards Is Yours?

STANDARD CONSTRUCTION PACKAGE Addendum A REV SITE & EXCAVATION Layout of the foundation and septic system as approved by local and state author

Business License Application

Advanced Ventilation for Residential applications FBC Res 2010.

Kelly Village Apartments 3118 Green Houston, Texas 77020

Energy Star Qualified - New Homes

1065 N Canyon St, Ste. 8, Hildale, UT Cell: (435) S Pioneer

Energy Provisions of the Kentucky Residential Code. Guide for Homeowners

COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION

General Contractor: Company Name: Location of Proposed Structure: Tax Map #: Lot #:

Passive House. An introduc+on to Western Technical College s wood built high performance building envelope project

Commercial Building Envelope Air Leakage

February 28, Prepared by: Michael Flatt ICF International 7160 North Dallas Parkway Suite 340 Plano, TX 75024

A/E Design Deliverable Checklist

Emerging Technologies for Cold Weather Residential Heating

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

Pulaski County, Virginia

Is Yours? Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards

Feasibility Report. Property Inspection Engineers, Inc. (248) Property Address. 405 Fairgrove Royal Oak, MI.

MASSEY HOFFMAN ARCHITECTS

2010 National Building Code Adoption and Associated Process Changes

Napa County Building Officials Coalition

Proposal. Lexington, MA. Price Work Description

CONSTRUCTION DOCUMENTS NECESSARY FOR PLAN REVIEW

RESIDENTIAL BATHROOM REMODEL

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

Transcription:

Using a Aerosol Sealant to Reduce Multifamily Envelope Leakage Dave Bohac PE Director of Research Ben Schoenbauer Senior Research Engineer Jim Fitzgerald Senior Building Analyst Center for Energy and Environment 2016 Energy Design Conference

Credit In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11, This educational offering is recognized by the Minnesota Department of Labor and Industry as satisfying 1.5 hours of credit toward Building Officials and Residential Contractors code /1 hour energy continuing education requirements. For additional continuing education approvals, please see your credit tracking card.

What We Do Energy Program Design & Delivery Engineering Services Lending Center Public Policy Innovation Exchange Research Education and Outreach Pg. 3

Multifamily Experience Facility assessments of over 2,000 buildings in Minnesota Completed over 20 research projects Pg. 4

Current Multifamily Research Projects PROJECT ANTICIPATE FINDINGS Condensing boiler optimization Early 2016 Multifamily ventilation optimization Early 2016 Multifamily aerosol envelope air sealing Mid 2016 Indoor pool optimization Late 2016 Demand controller recirculation loop Mid 2017 The Conserva,on Applied Research and Development (CARD) grant program is funded by MN ratepayers, and administered by the Minnesota Department of Commerce, Division of Energy Resources Pg. 5

Opportunity: Existing. Thousands of leaky units reduce air infiltration with limited or no added ventilation. New Construction. Moderately tight with ventilation seal to nearly eliminate air infiltration and air transfer.

Challenge: Existing. No/difficult/costly access to distributed air leaks. 10% to 25% reduction is challenging. New Construction. Single family approaches only recently starting to carry over to multifamily buildings.

Envelope Tightness Requirements: Code. 1 to 3 story buildings must meet 3.0 ACH50 residential requirement. 4+ story buildings - typically use tight materials or assembly to meet prescriptive requirement not whole envelope test. Green Communities (MHFA). EPA ENERGY STAR for multifamily high rise = 0.3 cfm50/sf (4 8 ACH50). No requirements prior to 2015.

Envelope Aerosol Sealing Pressurize apartment Spray air sealing fog Sealant particles build up on gaps as they flow through the leaks Similar to process used for aerosol duct sealing Pg. 9

How does it do that? No, really? (animation video here) Sealant is GREEN Guard Gold Cer,fied for use in California school and health care facili,es

Benefits: Reduced air infiltration energy costs Reduced odor transfer & improved IAQ Improved comfort Reduced noise transmission Simultaneous air leakage testing documents results Potential savings for avoided conventional air sealing (?)

Study Objectives: Demonstrate sealing capability and evaluate commercialization Refine sealing technique measure leakage and noise transmission reduction & identify sealing locations How to incorporate into sealing strategy preseal large leaks and protect horizontal surfaces as necessary Time estimates Model energy savings and effect on ventilation 1. Sealed 18 units in 3 new construction buildings 2. Sealed 9 units in 3 existing buildings Pg. 12

Aerosol Sealing Process: Design Visit Before Construction 1. Identify air tightness goal 2. Describe aerosol sealing process 3. Review air barrier details 4. Specify that leaks with gap width > 3/8 must be sealed or reduced to 3/8 5. Determine when aerosol sealing will be applied in construction process 6. Discuss conventional sealing that may not be necessary (consider fire code) This is ideal process Pg. 13

Aerosol Sealing Process: All In One Visit 1. Walk thru to identify pre-sealing & protection requirements (prior to sealing visit?) 2. Pre-seal large gaps & temporary sealing as necessary 3. Site work prep cover horizontal surfaces 4. Set up sealing equipment 5. Perform sealing 6. Remove coverings 7. Clean surfaces (if necessary) 8. Post-sealing air leakage test 9. Air leakage test when unit finished? Pg. 14

Site Work Prep: pre-seal wide gaps Sprinkler head Plumbing penetra,on Pg. 15

Site Work Prep: pre-seal wide gaps Low-voltage wiring Range electric line Pg. 16

Site Work Prep: pre-seal wide gaps AC Line set Duct narrow enough to leave? Pg. 17

Site Work Prep: pre-seal wide gaps Construc)on Plumbing Electrical Mechanical Floor wall Showerhead Range plug Line sets for HVAC connec,on penetra,on Sprinkler penetra,on Sink penetra,ons Electric baseboards Vent duct penetra,ons Waste line penetra,ons Low voltage wiring Fresh air duct penetra,on Clothes washer connec,ons Addi,onal wiring penetra,ons Combus,on and exhaust air penetra,ons Toilet water connec,on PTAC wall penetra,on Kitchen water connec,on Gas line penetra,ons (range, HVAC, laundry) 1 to 2 hours/unit Pg. 18

Site Work Prep: baseboards Seal before quarter round, caulk aser? What about leaky wood floors? Pg. 19

Site Work Prep: temporary sealing Exhaust fan ducts Combus,on vents Exterior doors Plumbing penetra,ons Fill traps or cover waste line openings Shower handles Pg. 20

Site Work Prep: temporary sealing Construc,on Plumbing Electrical Mechanical Door frames Bathroom handles Intercom Bath fan Floors (i.e. finished hardwood) Drains Low voltage outlets Kitchen fan Exterior doors (not Waste lines Smoke detectors Addi,onal ven,la,on used for fan frame) Large holes/openings in the envelope Alarms Combus,on and exhaust air Windows (leaky) Sprinkler heads PTAC openings Outdoor air intakes Forced air registers Forced air returns Pg. 21

Site Work Prep: cover horizontal surfaces Pg. 22

Site Work Prep: cover horizontal surfaces Ideal: drywall mud/tape no other finishes (bare floor be[er) Not ideal: ready for occupancy Pg. 23

Site Work Prep: cover horizontal surfaces Construc,on Plumbing Electrical Mechanical Floors Tub or shower surrounds and floors Ceiling Fans Top surface of baseboard hea,ng Window sills Toilets, sinks, other Light switches bathroom pieces Window mee,ng rail and Plumbing fixtures Light fixtures mun,ns Door tops and hardware Sprinkler heads Top surface of baseboards, trims, and molding Horizontal surfaces of cabinets and built-ins Temporary seals & covers: 3 to 7 hours/unit Pg. 24

Site Work: Set-up, Seal & Breakdown Blower door and nozzles 100Pa pressurization ~ 90% RH maintained Open windows & purge 6 to 7 hours/unit Remove Covers & Pack-up Care to not disturb seals Minimal clean-up 1.5 to 3.5 hours Pg. 25

Site Work Prep: how long does it take? 14 22 hours: still learning Pg. 26

Site Work Prep: reduce time Opportunities to reduce labor time Pre-sealing: new construction GC or sub completes Unit preparation: select time during construction when Minimum horizontal surfaces to protect Leaks are accessible Seals will be durable Sealing time: new generation of more portable equipment is being developed & stop when no longer cost effective Breakdown/clean-up: minimize surfaces to cover and better positioning of spray nozzles Pg. 27

Sealed Penetrations Pg. 28

Sealed Penetrations Pg. 29

Site Work Prep: black light photos Pg. 30

Leakage Reduced Over Injection Period New construction Floor area: 900 to 1,300sf ACH50 pre: 2.0 2.9, post: 0.2 0.7; 71% to 94% reduction Pg. 31

Sealing Rate Stop,me? Pg. 32

Leakage Reduced Over Injection Period New construction Floor area: 350 to 420sf Sealed 4 in one day ACH50 pre: 7.1 8.4, post: 0.9 1.4; 82% to 89% reduction Pg. 33

Leakage Reduced Over Injection Period Existing units Floor area: 230 to 250sf Sealed 4 in one day Large leak behind kitchen cabinet ACH50 pre: 12.0 17.2, post: 1.4 10.5; 39% to 88% reduction Pg. 34

Leakage Results: 18 New Construction Units 1-3 story code requirement Average leakage: pre= 3.9 ACH50, post= 0.7 ACH50 54% to 95% below code requirement, average= 77% Pg. 35

Leakage Results: New Construction Reduction: 67% to 94%, average = 81% Pg. 36

Leakage Results: 9 Existing Units 1-3 story code requirement Average leakage: pre= 14.1 ACH50, post= 4.8 ACH50 6 of 9 within 15% of new construction code requirement Pg. 37

Leakage Results: Existing Units Reduction: 39% to 89%, average = 68% Pg. 38

Reduced Noise Transmission Sound transmission testing was conducted in a MF building in NY Protocol based on ASTM E90 Seal was an effective sound barrier between 800-5000 Hz Human voice frequency falls between 300-3000 HZ Helps to meet Building Code (IBC) requirement of 50 STC Pg. 39

Energy & Ventilation Modeling EnergyPlus model: air flows computed from leakage paths and wind/stack/ventilation imbalance Three levels of tightness: 9.5 ACH50 (leaky/existing) 3.0 ACH50 (new code) 0.6 ACH50 (aerosol sealed) Ventilation systems (0.35ach = 70cfm rqd): balanced exhaust only supply = half of exhaust none 6 story, 4 units/floor 1,200sf/unit Leakage Distribu,on Exterior = 28% Hallway = 51% Adj Unit = 16% Ceiling = 5% Pg. 40

Energy & Ventilation Modeling New Construc,on Therm/yr 12 17 27 26 $/yr $7 $10 $16 $15 4% 8% 11% 18% Pg. 41

Energy & Ventilation Modeling Exis,ng Units Therm/yr 41 56 67 68 $/yr $24 $33 $39 $39 11% 17% 19% 25% Pg. 42

Energy & Ventilation Modeling New Construc,on Outside Air Ven,la,on & Infiltra,on 0.6 ACH50 = 96 cfm50; depressuriza,on??? Pg. 43

Energy & Ventilation Modeling New Construc,on Flow From Adjacent Apartment 68 to 80% Reduc,on Pg. 44

Energy & Ventilation Modeling New Construc,on Flow From Corridor Pg. 45

Energy & Ventilation Modeling Exis,ng Units Outside Air Ven,la,on & Infiltra,on Pg. 46

Energy & Ventilation Modeling Exis,ng Units Flow From Adjacent Apartment 85% to 87% Reduc,on Pg. 47

Air Sealing at Lower Cost? Aerosol Prep Sealing process Simultaneous air leakage testing ensures results Manual air sealing i.e. caulking/foaming Architectural specification Labor Air leakage test => Uncertain results Vs. Pg. 48

Conclusions Not a solution for large air leak gaps When aerosol envelope sealing can be used New construction Rehab Change in occupancy (higher cost) New construction 81% reduction & 77% below code Heating savings= 27 therms/yr, 11% 80% reduction in flows from adjacent units Existing units 68% reduction & 6 of 9 within 15% new code Heating savings= 67 therms/yr, 19% 85% reduction in flows from adjacent units Balanced ventilation is crucial for new construction, exhaust or supply OK for existing Can you eliminate some conventional sealing? If not, too costly? Pg. 49

Dave Bohac dbohac@mncee.org Ben Shoenbauer bshoenbauer@mncee.org