Developing an Environmental Analysis of Soils and Water by Spectrochemical Techniques for Undergraduate Students of Chemistry

Similar documents
National Food Safety Standard

Analysis of Metals in Water, Stream Sediments and Floodplain Soils Collected March 21-23, 2005 from the Bayou Creek System. David J.

Determination of sodium, calcium, copper, iron and manganese in pulp and paper by atomic absorption spectroscopy (Five-year review of T 266 om-11)

Background Statement for SEMI Draft Document 4795 (Yellow Ballot) NEW STANDARD: SPECIFICATIONS FOR NITRIC ACID, USED IN PHOTOVOLTAIC APPLICATIONS

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

Review on Agriculture and Rural Development vol. 2. (1) ISSN

SEMI C SPECIFICATIONS AND GUIDELINES FOR AMMONIUM HYDROXIDE

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline

Madhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh

Background Statement for SEMI Draft Document 5134 Revision to SEMI C , Specifications for Hydrofluoric Acid

Background The document will be revised for its five year review and updated per the committee agreed upon changes.

Analysis of Trace Metals in Tobacco and Tobacco Ash using Atomic Emission Spectroscopy

Trace elements determination AAS

PINAACLE 500/900 AA AND SUPPLIES CONSUMABLES. Consumables and Supplies Reference Guide

SPECTROPHOTOMETRIC DETERMINATION OF IRON

EDX 600. Atomic Absorption Spectrometry

Standard Solutions (Traceable to NIST)

Measuring Manganese Concentration Using Spectrophotometry

Standard Solutions (Traceable to NIST)

CONTRIBUTIONS TO THE STUDY OF ENVIRONMENTAL POLLUTION WITH HEAVY METALS

A COMPARATIVE ANALYSIS FOR A CONTENT OF MANGANESE IN PLANTS. D. Kostova Agricultural University Plovdiv 12, Mendeleev Str., 4000 Plovdiv, Bulgaria

ABSTRACT: Clean sampling and analysis procedures were used to quantify more than 70 inorganic chemical constituents (including 36 priority

Assessment of Water Quality of Three Different Aquatic Environments Over Three Seasons

Photochemical studies of Eichhornia crassipes (Water Hyacinth)

ELEMENTS by ICP 7301 (Aqua Regia Ashing)

GB/T Translated English of Chinese Standard: GB/T

Final Exam. Physical Constants and Conversion Factors. Equations

Heavy Metal Mobility from Marine Sediments due to Erosion and Resuspension

VHG Labs. Standards and Supplies for Spectrochemical Analysis QUALITY. TRACEABILITY. DEPENDABILITY. WORLDWIDE

KEYWORDS: Adsorption, Chromium(VI), COD, Tannery Effluent, Banyan Sawdust.

METHOD #: Approved for NPDES and SDWA (Issued 1974) Mercury (Automated Cold Vapor Technique) ANALYTE: CAS # Hg Mercury

Improved Antimony Recoveries in Soil Matrices by 3050B/6010B. DataChem Laboratories, Inc. Robert P. Di Rienzo Jeffery S. Ward John T.

IRON (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 600 C

Ground Water & UST Samples: Containers, Preservation and Hold Times Table

Recovery of Cu, Zn, Ni and Cr from Plating Sludge by Combined Sulfidation and Oxidation Treatment

Recovery of Cu, Zn, Ni and Cr from Plating Sludge by Combined Sulfidation and Oxidation Treatment

METHODS OF ANALYSIS BY THE U.S. GEOLOGICAL SURVEY NATIONAL WATER QUALITY LABORATORY-- DETERMINATION OF CHROMIUM IN WATER BY GRAPHITE

NADUF: Methods of the chemical Analysis (EAWAG)

NADUF: Methods of the chemical Analysis (EAWAG)

Standard Methods for the Examination of Water and Wastewater

1-(2-Pyridylazo)-2-Naphthol PAN Method 1 Method to mg/l Mn (LR) Powder Pillows

METHOD 7550 OSMIUM (ATOMIC ABSORPTION, DIRECT ASPIRATION)

1. Introduction. 2. Scope and application. 3. Objectives

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)

GB Translated English of Chinese Standard: GB

EU water analysis using the Thermo Scientific icap 7400 ICP-OES Duo

SurTec 712 Alkaline Cyanide-Free Zinc/Iron Process

Investigations into Method Improvements for Hexavalent Chromium. Presented by Aaron Rose Thermo Fisher/Dionex Products For 2012 Watercon

HEAVY METALS IN RELATION TO SOIL FODDER MILK

Atomic Spectroscopy Solutions for Environmental Applications

Environment Agency. The determination of metals in solid environmental samples (2006) Methods for the Examination of Waters and Associated Materials

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Rubber and plastics gloves for food services Limits for extractable substances

Chromium plating bath

ISO INTERNATIONAL STANDARD. Paper, board and pulps Determination of total magnesium, total calcium, total manganese, total iron and total copper

Determination of Elemental Impurities in Graphite-based Anodes using the Agilent 5110 ICP-OES

Test sticks and test papers for semi-quantitative determinations

Analysis of an OTC Multivitamin Tablet Using X-ray Fluorescence Spectroscopy and Atomic Absorption Spectroscopy

PinAAcle 900 AA Flame AA

The ion with Vanadium in its oxidation state of 5 exists as a solid compound in the form of a VO 3

SurTec 609 EC Pre-Treatment prior to E-Coat

Background Statement for SEMI Draft Document 4546A REVISION OF SEMI C , with title change to SPECIFICATIONS FOR HYDROGEN PEROXIDE

SEMI C SPECIFICATIONS AND GUIDELINES FOR HYDROGEN PEROXIDE

Passive Water Distillation: Water QualityAnalysis

REPORT NUMBER REPORT DATE SEND TO ISSUE DATE Apr 18, Apr 18, 2017 RECEIVED DATE Apr 05, 2017

ELEMENTS by ICP 7301 (Aqua Regia Ashing)

ELEMENTS by ICP 7300 (Nitric/Perchloric Acid Ashing)

TITLE: SABS PROFICIENCY TESTING SCHEME, RSA

METHOD 3031 ACID DIGESTION OF OILS FOR METALS ANALYSIS BY ATOMIC ABSORPTION OR ICP SPECTROMETRY

Direct Determination of Thallium in Water by Pre-concentration with the PinAAcle 900H GFAAS

Quantitation of a Hexavalent Chromium Bull. Korean Chem. Soc. 2012, Vol. 33, No

SurTec 717 Alkaline Zinc/Nickel Electroplating Process (Electrolyte based on Sodium)

ENVIRONMENTAL IMPACTS OF SHEBA TANNERY (ETHIOPIA) EFFLUENTS ON THE SURROUNDING WATER BODIES

ICSE-Science 2 (Chemistry) 2004

Determination of iron content in iron oxide used for fireworks and firecrackers based on Energy Dispersive X-ray Fluorescence Spectrometry (EDXRF

Dimethylphenol Method Method LR (0.23 to mg/l NO 3 N or 1.00 to mg/l NO 3 ) TNTplus 835

Technical Note Electroplating wastewater treatment through chemical precipitation and electrodialysis

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

Guideline regarding analysis on Fujitsu Group specified chemical substances

Water Analysis Using ICP-OES with an Ultrasonic Nebulizer

Notification of Ministry of Industry. Industrial Effluent Standards B.E. 2560

DRPK-005

Background Statement for SEMI Draft Document 4651 REVISION OF SEMI F GUIDELINES FOR ULTRAPURE WATER USED IN SEMICONDUCTOR PROCESSING

Report of STSM under COST Action FP1301: EuroCoppice PHYTOREMEDIATION POTENTIAL OF DIFFERENT POPLAR CLONE COPPICE PLANTATION

DETERMINATION OF SULPHUR CONTENT OF UN-ALLOYED AND LOW-ALLOYED STEEL BY ICP-AES SPECTROMETRY USING WET CHEMICAL SAMPLE PREPARATION

was developed for the determination of thallium at the ng/ml

Institute for Reference Materials and Measurements Community Reference Laboratory for Feed Additives

» Talc is a native, hydrous magnesium silicate, sometimes containing a small proportion of aluminum silicate.

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

SCOPE OF ACCREDITATION TO ISO 17034:2016


*20GSD5201* Double Award Science: Chemistry. Unit C2 Higher Tier WEDNESDAY 15 JUNE 2016, AFTERNOON [GSD52] *GSD52* *G5802* TIME 1 hour 15 minutes.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Surface Water Samples: Containers, Preservation and Hold Times Table

USEPA 1 Periodate Oxidation Method 2 Method to 20.0 mg/l Mn (HR) Powder Pillows

The Determination of Toxic Metals in Waters and Wastes by Furnace Atomic Absorption

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

Transcription:

Journal of Laboratory Chemical Education 2014, 2(1): 4-9 DOI: 10.5923/j.jlce.20140201.02 Developing an Environmental Analysis of Soils and Water by Spectrochemical Techniques for Undergraduate Students of Chemistry Jesús Anzano *, LeyreAbia, Minerva Aragonés, Elena Ballano, Beatriz Guzmán, Mª Luisa Lomero, Catalina Pena, Elisa Pérez Laser laboratory, Department of Analytical Chemistry, Faculty of Sciences, University of Zaragoza, Pedro Cerbuna #12, 50009, Zaragoza, Spain Abstract Quantification of heavy metals (Cr, Cu, Zn, K, Ca, Fe and Mn) in water and soils samples was performed through atomic and molecular spectrometry. The validity of three leaching agents (ethylenediaminetetraacetic acid, acetic acid and deionized water) was compared in soil samples to potassium, calcium, iron and manganese by means of atomic spectrometry. Acetic acid was the best leaching agent for all metals except for iron, and EDTA was the second best. Two experiments were developed for water samples. First, precipitation was used to separate toxic metals and, secondly, the speciation of Cr (III) and Cr (VI) was carried out using diphenylcarbazide and ethylenediaminetetraacetic acid to set up complexes selectively. It was proved that the removal of Cr, Cu and Zn by precipitation of the hydroxide was effective obtaining low ranks. Keywords Atomic and Molecular Spectroscopy, Determination, Potassium, Calcium, Iron, Manganese, Chrome, Cupper, Zinc, Soil, Water 1. Introduction Nowadays, the presence of heavy metals in the environment is a very interesting issue, due to their persistence in soils and waters[1]. Considerable amounts of polluting metals are accumulated yearly. Soil and water are among the valuable common properties societies try to preserve the most, but they can be polluted by household, industrial or farming wastes. Heavy metals are among the polluting substances, usually coming from industrial processes such as paint production or chroming[2]. From a chemical point of view, heavy metals contain elements known as transition and post-transition. Those elements are significantly heavier than light metals like K or Na. Some of them are animal and plant nutrients but they are toxic in high concentrations. For example, trivalent chromium is an essential oligoelement and its deficiency causes diabetes and other adverse effects in the body. However, hexavalent chromium is extremely toxic, as it causes allergy, breath and liver deficiency, mutations and cancer[3]. Because of these harmful effects in the long and short-term, maximum admissible concentrations of the * Corresponding author: janzano@unizar.es (Jesús Anzano) Published online at http://journal.sapub.org/jlce Copyright 2014 Scientific & Academic Publishing. All Rights Reserved seions in drinking water, publicor industrial discharges must be regulated by the applicable laws. Toxic concentration limits are different to each metal and depend on the kind of ion and its physiological and environmental effects. European law (Directive 98/83/CE, 3 of November of 1998, relating to drinking water quality published in DOCE L Nº 330, 5 of December of 1998) fix chromium (0.05 mg/l) and cupper limits (2 mg/l) in drinking water. Zinc does not have risk level in water but World Health Organization lay down 5 mg/l as a legal limit. On the other hand, law 22/2011 (28 of July, of wastes and contaminated soils) and law 1/2005 (4 of February, of prevention and correction to soils contamination) regulate contaminated agents in soils[4, 5]. Analytic techniques for metal analysis in soils and water samples are varied; their election depends on the metal concentration grade and its nature. Usual techniques are: Flame Atomic Absorption Spectrometry (AAS-Flame), Graphite Furnace Atomic Absorption Spectrometry (GFAAS), Inductively Coupled Plasma - Atomic Emission Spectrometer (ICP-AES), Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). Multielement analysis and automatic techniques result particularly useful because they generate big data series and they need minimum effort and time[6]. This article contains two different parts: metal determination in soils and in water. In our case, we search

Journal of Laboratory Chemical Education 2014, 2(1): 4-9 5 calcium, iron, manganese and potassium concentrations in soil samples. We make a leaching with different extract agents (ethylenediaminetetraacetic acid, acetic acid and deionized water) and we quantify each metal by Atomic Emission Spectrometry (AES) and Atomic Absorption Spectrometry (AAS). Apart from this method, others have been published, which are effective to heavy metals elimination. Two of them are Cr (III) extraction with coal[7]; and the use of modified polymers which allow the division of selectively toxic ions such as Pb (II), Cd (II) or Ni (II)[8]. Other example is biosorption metal elimination using biomass that is a field on the increase[9, 10]. Otherwise, we proceeded to the separation, removal and quantification of Cr (VI), Zn (II) and Cu (II) in wastewater by precipitation with ph control and AAS-flame, and then we proceeded to the specific determination of chromium in dissolution problem. Spectrophotometric techniques are commonly used as a UV-visible absorption, chemiluminescence and fluorimetry because they allow making a selective determination of metallic species by means of the use of reactive that creates absorbent chemical species selectively. The most common method to determine Cr (VI) in aqueous solution is based on the selective reaction of diphenylcarbazide (DPC) to Cr (VI) to ph ~ 1[11]. This reaction has also been used for the extraction of chromium from their samples by techniques such as ion chromatography or solid phase extraction. This reaction forms a colored complex which absorbs in the visible (λ = 542 nm), the absorbance of which can be related to the concentration of Cr (VI) by the Beer-Lambert law. For performance an analysis of total chromium content of a sample by this method had to be made a pre-oxidation of the sample, the actual concentration of Cr (III) was obtained by difference between the concentration of total chromium and Cr (VI). Thus, our goal was the determination of Cr (III) and Cr (VI) in a test solution UV-visible spectroscopy using diphenylcarbazid. This article is developed at the Faculty of Sciences, University of Zaragoza[12]. The target students belong to the internship done in the fourth course of the Bachelor s degree in Chemistry. 2. Experimental 2.1. Apparatus A Perkin-Elmer Model 2380 atomic absorption/emission spectrometer, fitted with Perkin-Elmer (calcium, manganese, iron, chromium, copper, zinc) hollow-cathode lamps was used for measure the contents of metals in soils and waste waters. Calcium, manganese, iron, chromium, copper and zinc were determined by Flame-AAS, while potassium was determined by Flame-AES (no lamp required). The instrumental parameters used in measuring the absorption/ emission of the studied elements are given in the table 1. A Perkin Elmer Model EZ 201 UV-Vis molecular absorption spectrometer was used for chromium speciation in water samples. (Plastic cuvettes will suffice). The measuring was made at a wavelength of 542 nm. Table 1. Instrument parameters used in the measurements by flame atomic absorption /emission spectrometry Element Wavelength/ nm Working range µg ml -1 Calcium 422.7 0-10 Manganese 279.5 0-2 Iron 248.3 0-10 potassium 766.5 0-2 Chromium 273.9 0-6 Copper 324.8 0-10 zinc 213.9 0-2 *Lamp current 25 ma, flame air/acetylene (blue, oxidizing)[except for Chromium, flame air/acetylene (red, reducing), Slit 0.7 nm. 2.2. Reagents The reagents used for the analysis of soils were: Acetic Acid (0.43M) [Panreac, http://www.panreac.es/], EDTA (0.05M) [Panreac], Nitric Acid[Panreac]. Calcium standard solution, 1000 µg ml -l. Prepared by dissolving 2.52 g of calcium carbonate in 50 mi of 1MHCI and diluting to 11 with water. Manganese solution, 1000µg ml -l. Prepared by dissolving 3.25 g of manganese nitrate in 50 mi of 1MHCI and diluting to 11 with water. Iron solution, 1000µg ml -l. Prepared by dissolving 4.33 g of iron nitrate in 50 mi of 1MHCI and diluting to 11 with water. Potassium solution, 1000 µg ml -l. Prepared by dissolving 2.6 g of potassium nitrate in 50 mi of 1MHCI and diluting to 11 with water. All solutions were prepared with analytical-reagent grade chemicals and re-distilled water. They were kept in polyethylene containers. This solution is stable for at least 2 months. Solutions of lower concentrations of these three metals were prepared each dar by diluting the standard solutions. The reagents used for the analysis of water were: Sulfuric Acid [Panreac], Calcium Chloride [Panreac], Sodium Hydroxide [Merck, http://www.merck.es], Ascorbicacid [Panreac], Diphenylcarbazide [Scharlau], Acrylamide, Potassium manganate (VII)[Scharlau] The solutions were prepared with analytical-reagent grade chemicals and distilled water. Chromium solution 1000 mg/l, dissolve 0.283 g of potassium dichromate in 50 ml.[panreac]. Copper solution 1000 mg/l, dissolve 0.3862 g of copper (II) nitrate in 50 ml. [Panreac]. Zinc solution 1000 mg/l, dissolve 0.2830 g of zinc (II) nitrate in 50 ml. [Panreac]. 2.3. Samples

6 Jesús Anzano et al.: Developing an Environmental Analysis of Soils and Water by Spectrochemical Techniques for Undergraduate Students of Chemistry Soil Sample: Commercial fertilizer (Auchan, http://www.simply.es) Humidity (105ºC) = 50±10%; ph = 5.5-6.5; Mineral fertilizers: (N)=220mg/l ± 10%; (P 2 O 5 )= 225mg/l ± 10%; (K) => K 2 O= 300mg/l ± 10%. Wastewater Samples: Provided by the Analytical Chemistry Department of University of Zaragoza. 2.4. Procedure Humidity of soil sample determination.-approximately 1g of soil sample is weighted and then it was dried in a stove (~105ºC) until no change of weight is observed. The percentage of humidity will be useful later to refer the results of metal content to the dry sample. Extraction with EDTA.-A solution (200 ml) of EDTA 0,05M is prepared from the salt, and is adjusted to ph 7 by the addition of diluted ammonia and 5g of soil sample are weighted inside a plastic container and 50 ml of EDTA 0,05M are added. The contents of the container are stirred vigorously for 1h at room temperature. The extract is decanted and filtered, being collected into a 50 ml flask. Extraction with acetic acid.-a solution (500 ml) of HAc 0,05M is prepared from commercial HAc and 5g of soil sample are weighted inside a plastic container and 200 ml of HAc 0,05M are added.the contents of the container are stirred vigorously for 24h at room temperature.the extract is decanted and filtered, being collected into a 50 ml flask with 2 ml of HNO 3 (conc.). Extraction with water.-40g of soil sample are weighted inside a plastic container and 100 ml of distilled water are added. The contents of the container are stirred vigorously for 2h at room temperature. The extract is decanted and filtered, being collected into a 50 ml flask with 2 ml of HNO 3 (conc.). Determination of K, Ca, Fe, Mn using calibration graph.- Using the stock solutions for each metal, intermediate dilutions are prepared. These intermediate dilutions are diluted further to prepare series of calibration standards in the range of 1 to 10 mg/l of the metal. The range and number of points for the calibration may vary between metals. Using the appropriate wavelength in the spectrometer, the absorption of the calibration standards is measured to provide the corresponding calibration curves. Then, the absorption of the extracted samples is measured and interpolated. Determination of Cr, Cu, Zn by Atomic Absorption Spectometry Sample treatment-transfer 20 ml of the sample into 5 glasswares and acidify them to ph 2.98 (measuring with a phmeter). Add a few milligrams of ascorbic acid and 3 ml of CaCl 2 solution which will act as a co-precipitate. Adjust the solutions again using the ph meter to different ph with a NaOH solution: 6.3, 8.4, 10.78 and 12. One of them will remain at ph 2.98. Finally add a few milligrams of acrylamide, a clarifying agent. Let the samples rest for 30 minutes and then filter them to separate the precipitate. Wash the solid with water. Transfer the solutions into 100 ml flasks and make them up to volume with distilled water. Preparation of calibration standards and blank. Using the stock solutions for each metal, intermediate dilutions are prepared. These intermediate dilutions are diluted further to prepare series of calibration standards in the range of 1 to 10 mg/l of the metal. The range and number of points for the calibration may vary between metals. Calibration graph of chromium, zinc and copper: 0,3 Absorbance 0,25 0,2 0,15 0,1 0,05 0 y = 0,0266x + 0,0150 R 2 = 0,9946 0 2 4 6 8 10 12 Concentration Chromium (mg/l)

Journal of Laboratory Chemical Education 2014, 2(1): 4-9 7 Absorbance 0.180 0.160 0.140 0.120 0.100 0.080 0.060 0.040 0.020 0.000 y = 0.0772x + 0.002 R² = 0.9987 0 0.5 1 1.5 2 2.5 Zn Concentration (mg/l) 0.4 0.35 0.3 0.25 y = 0.0338x - 3E-08 R² = 1 Cu Absorbance 0.2 0.15 0.1 0.05 0-0.05 0 2 4 6 8 10 12 Concentration (mg/l) To prepare the blank add 3 drops of NaOH 1M, 3 drops of CaCl 2 10% and a few milligrams of ascorbic acid and acrylamide into a 100 ml flask. Level up with distilled water. Absorption measurements of standards and samples. -Using the appropiate wavelength in the spectrometer, the absorption of the calibration standards is measured to provide the corresponding calibration curves. Then, the absorption of the samples is measured and interpolated. Chromium speciation in contaminated waters by UV-Vis espectrophotometry Diphenylcarbazyde method Preparation of diphenylcarbazyde solution and calibration standards. A solution of diphenylcarbazyde 0.25% is prepared by dissolving diphenylcarbazyde in acetone, adding 5 ml of sulphuric acid (1:10 dilution) and level up to 50 ml. The calibration standards (0 to 2 mg/l) are prepared using a stock solution of chromium (VI). Sample treatment To a fraction of 40 ml of the problem sample, 3 ml of sulphuric acid 3M are added. The solution is covered with a watchglass and boiled for 5 minutes. After cooling, 4 drops of a KMnO 4 solution are added. After another 20 minutes of heating (without boiling), a tip of sodium azide is added to eliminate the excess of the oxidant. The solution is transferred to a 50 ml flask, 5 ml of diphenylcarbazyde 0.25% are added and the solution is level up with distilled water. The same procedure is repeated for a sample without adding KMnO 4, and also for a reference blank (40 ml of water) for both experiments.

8 Jesús Anzano et al.: Developing an Environmental Analysis of Soils and Water by Spectrochemical Techniques for Undergraduate Students of Chemistry Absorbance measurement The measures are made in the visible spectrum, so plastic cuvettes may be used. A wavelength scanning must be made to find the wavelength at which the maximum absorbance occurs. On the selected wavelength, the absorbance of standards, samples, and blanks is measured. 3. Determination of Metals Heavy in Soils Using the proposed method, was carried out the study of a sample provided by the University of Zaragoza (Universal Soil fertilized (Auchan)). This is performed with the following three determinations leaching agents: EDTA, HAc and distilled water, so get extract the metals present in the sample and subsequently determine them by EAA and EAA. The results are shown in the following table 4. Depending on the results we can observe that the best leaching agent would be acetic acid (HAc) achieving good results for Ca, Mn and K while for Fe concentration obtained is lower. The second best performing leaching agent offers serious EDTA because the concentrations obtained are significant for all elements studied. Also has the lowest leaching time has over the other leaching agents used, which, provides a significant advantage over the other. Finally, the results indicate that water could be used for analysis of alkaline in our case K and Ca, but other elements such as in the case of Fe and Mn, the results would not be significant. ACKNOWLEDGMENTS The authors thank Prof. Micaela Muñoz from University of Zaragoza for her help. This work was supported by the Department of Science, Technology and University of the Aragon Regional Government and the ESF (group E75) and the University of Zaragoza (proposal #UZ2012-CIE-02). Table 2. Determination of chromium, copper and zinc by controlling the ph Cr Cu Zn Sample ph 3 ph 6 ph 8 ph 10 ph 14 ph 3 ph 6 ph 8 ph 10 ph 14 ph 3 ph 6 ph 8 ph 10 ph 14 3* 86,18 2,08 >10 4* 4,74 6,05 1,15 7* 46,70 43,35 39,80 15,6 27,65 25,90 16,95 1,90 14,50 11,40 8,05 1,50 8* 77,30 67,20 38,45 19,10 46,10 37,15 16,80 7,85 5,90 25,50 13,75 6,80 4,75 4,10 * Total chromium content (µg/g) in water by Molecular Absorption Spectrometry: Sample 3 36,4 Sample 4 13,718 Sample 7 15,801 Sample 8 9,1667 Table 3. Results determination of chromium Cr(III) Cr(VI) Sample Cr (III) ug/g Rango DSR (%) Cr (VI) ug/g Rango DSR (%) n 1 0,81375 0,601-1,007 22,3 0,7535 0,636-0,882 15,8 4 2 0,4925 0,302-0,674 35,68 0,7491 0,597-0,879 16,39 4 3 0,245 0,121-0,366 50,02 0,3881 0,07-0,478 23,43 4 With respect to the total chromium content determined in samples problem from the method used with diphenylcarbazide, will see that all of them are below the permitted maximum level of Cr(VI) in water, is 50 μg/l Table 4. Summary determination of elements in soils by AAS Calcium Potassium Manganese Iron EDTA Aceticacid Water EDTA Aceticacid Water EDTA Aceticacid Water EDTA Aceticacid Water Average (µg/g sample) 4889.1 11048.5 475.09 1176.2 3126.9 454.05 2.726 7.908 0 151.37 27.697 0 Standard deviation 1067.5 1386.6 66.396 1140.9 1747.2 188.46 1.478 6.037 0 53.62 27.731 1 N 5 5 5 5 5 5 5 5 5 5 5 5 Rango 3822-5957 9662-12435 409-541 35-2317 1380-4874 266-643 1.0-4.0 2.0-14 0.0-1.0 98-205 0-55 0.0-1.0 Calibrationgraph of chromium, zinc and copper

Journal of Laboratory Chemical Education 2014, 2(1): 4-9 9 REFERENCES [1] Alvarez, M.; Domini C.; Garrido M.; Lista A.; Fernández-Band B. J.,Single-stepchemicalextractionprocedu res and chemometricsforassessment of heavy metals behaviour in sedimentssamples, J. soils and sediment, 2011, 11, 657 666. [2] Xuelu, G., Peimiao, L., Concentration and fractionation of trace metals in surfacesediments of intertidal BohaiBay, China, Marine PollutionBulleti, 2012, 64, 1529 1536. [3] Shafique, U.; Anwar, J.; Anzano, J. M.,Treatment of chromiumpollutedwaterthroughbiosorption: An environment friendly approach, Nova SciencePublishers, 2010, 7. [4] Spain. Law 22/2011 of 28 July. OfficialStateBulletin, 29 July 2011, 181, p. 85650. [5] Spain. Law 1/2005 of 2 February. OfficialStateBulletin, 14 November 2011, 274, p.117142. [6] www.juntadeandalucia.es/temas/medio-ambiente/recursos/su elo.html, accessedmay 2013. [7] Anwar, J.; Shafique, U.; Salman, M.; Anwar, S.; Anzano, J. M., Removal of chromium (III) byusingcoal as adsorbent, J. Hazard. Mater, 2009, 171, 797-801. [8] Zayed, A.; Shahab,M., Fe(3)O(4)/cyclodextrinpolymernanoc ompositesforselective heavy metalsremovalfrom industrial wastewater, Carbohydratepolymers, 2012, 91, 322-32. [9] Trevino-Cordero, H.; Juarez-Aguilar, L. G.; Mendoza- Castillo, D. I., Synthesis and adsorptionproperties of activatedcarbonsfrombiomass of Prunus domestica and Jacaranda mimosifoliafortheremoval of heavy metals and dyesfromwater, Industrial crops and product 2012, 42, 315-323. [10] Zeiner,M.; Rezic,T.; Santek,B., Removal of Cr, Mn, and Co fromtextilewastewaterby horizontal rotating tubular bioreactor, Environmentalscience&technology, 2012, 46, 10690-10696. [11] Scindia,Y.M.; Pandey,A.K.; Reddy, A.V.R.; Manohar, S.B., Chemicallyselectivemembraneoptodefor Cr(VI)determinatio n in aqueoussamples, Anal. Chem. Acta., 2004, 51, 311-321. [12] Faculty of Science, Zaragoza, Spain, www. ciencias.unizar.e s/web/, accessedmay 2013.