Solar Thermal Radiant Heating at Pohakuloa Training Area

Similar documents
Solar Thermal Radiant Heating at Pohakuloa Training Area

Geothermal Energy Demonstration at Fort Indiantown Gap

Photovoltaic (PV) Systems Comparison at Fort Hood

NDCEE. Zero-Energy Housing (ZEH) for Military Installations. National Defense Center for Energy and Environment. Ms. Heidi Anne Kaltenhauser, CTC

Ultraviolet (UV) Curable Coatings DoD Executive for Bullet Agent Tip Identification

NDCEE. Landscape Modeling Technologies for Sustainable Forests. National Defense Center for Energy and Environment. Ms. Donna S.

NDCEE. Ecosystem Banking Best Practices. Elizabeth Keysar, NDCEE/CTC. National Defense Center for Energy and Environment

Flexible Photovoltaics: An Update

NDCEE National Defense Center for Energy and Environment

Tim A. Hansen, P.E. Southern Research Institute NDIA E2S2 May 2012

Water Sustainability & Conservation in an Exhaust Cooling Discharge System Case Study

Sustainable Contingency Bases Reducing the Logistical and Environmental Footprint

Improving Energy Efficiency at the Watervliet Arsenal

NDCEE. Evaluation of Alternative Particle Filtration Designs to Reduce RDX Losses in Dewatering Operations

Microgrid with Solar Power and Fuel Cell Technology

309th Commodities Group

Geothermal Energy Demonstration at Fort Indiantown Gap

NDCEE. Cadmium and Hexavalent Chromium Free Electrical Connectors: A Synergistic Approach. National Defense Center for Energy and Environment

Improvements to Hazardous Materials Audit Program Prove Effective

Implementation of the Best in Class Project Management and Contract Management Initiative at the U.S. Department of Energy s Office of Environmental

Navy s Approach to Green and Sustainable Remediation

Decision Framework for Incorporation of Sustainability into Army Environmental Remediation Projects

NDCEE. Joe Jackens, NDCEE/CTC. National Defense Center for Energy and Environment

Department of Defense Green Procurement Program and Biobased Products

Fort Belvoir Compliance-Focused EMS. E2S2 Symposium Session June 16, 2010

Efficiency & Environmental (E2) Solutions for Small Forward Operating Bases

Tactical Equipment Maintenance Facilities (TEMF) Update To The Industry Workshop

PL and Payment of CWA Stormwater Fees

ITEA LVC Special Session on W&A

DoD Sustainability Strategy The Latest. Mr. Dave Asiello DUSD(I&E)/CMRM

DEPLOYED BASE SOLAR POWER (BRIEFING SLIDES)

DoD Sustainable Buildings. Col Bart Barnhart ODUSD(I&E) May 12, 2011

RFID and Hazardous Waste Implementation Highlights

CORROSION CONTROL Anniston Army Depot

Energy Security: A Global Challenge

Microscale Waste Heat Driven Cooling System

Mobile Wastewater Treatment Technology for Contingency Bases. Shan Abeywickrama, NDCEE/CTC Elizabeth Keysar, NDCEE/CTC. E2S2, New Orleans May 24, 2012

Developing an Army Water Security Strategy

Two Approaches to Rehabilitation of Metal Roofing at Wheeler Army Airfield Hawaii

Army Ground Vehicle Use of CFD and Challenges

Kelly Black Neptune & Company, Inc.

An Open Strategy for the Acquisition of Models and Simulations. Rudolph P. Darken Director, MOVES Institute

Joint JAA/EUROCONTROL Task- Force on UAVs

Earned Value Management on Firm Fixed Price Contracts: The DoD Perspective

NOGAPS/NAVGEM Platform Support

Army Quality Assurance & Administration of Strategically Sourced Services

Panel 5 - Open Architecture, Open Business Models and Collaboration for Acquisition

Vehicle Thermal Management Simulation at TARDEC

FIELD TESTS OF FROST JACKING OF UNEXPLODED ORDNANCE

Robustness of Communication Networks in Complex Environments - A simulations using agent-based modelling

Issues for Future Systems Costing

Enhance Facility Energy Management at Naval Expeditionary Base Camp Lemonnier, Djibouti. 12 May 2011

Simulation of Heating of an Oil-Cooled Insulated Gate Bipolar Transistors Converter Model

Laura Biszko NSRDEC /03/2011 UNCLASSIFIED

Hybrid Vapor Compression Ejector Cycle: Presentation to IAPG Mechanical Working Group

Sustainability Action Planning and Initiatives at Twentynine Palms Marine Corps Air Ground Combat Center (MCAGCC) May 2011

Defense Business Board

Sustainable Management of Available Resources and Technology (SMART) Cleanup

DoD Solid Waste Diversion

Cataloging Green Items

DoD Installations, Energy and the Environment: The Challenge and Opportunity

Aeronautical Systems Center

NAVY REGION SOUTHWEST SUSTAINABLE SOLID WASTE PROGRAM. Construction and Demolition Debris Management. Leslie L. McLaughlin

Defense Supply Center Philadelphia Buying Green Through DSCP June 16, Presented by Tony Armentani (DSN 444)

Trends in Acquisition Workforce. Mr. Jeffrey P. Parsons Executive Director Army Contracting Command

SE Tools Overview & Advanced Systems Engineering Lab (ASEL)

DLA Troop Support Clothing & Textiles

Army Net Zero Installation Initiative and Cost Benefit Analysis Activity

Alex G. Manganaris Director, Workforce Plans and Resources

ROCK STRIKE TESTING OF TRANSPARENT ARMOR NLE-01

Forward Operating Bases Solid Waste Characterization

SEDD Our Vision. Anand Mudambi. Joseph Solsky USACE USEPA 3/31/2011 1

Sipping at the Straw: Planning for Sustainable Water Supplies for U.S. Army Installations

Standard Design for TEMF

UNITED STATES ARMY AVIATION and MISSILE LIFE CYCLE MANAGEMENT COMMAND. The Evolution of Protective Covers for Army Aviation and Missile Systems

Future Capabilities of GenCade Ashley Frey

The Nuts and Bolts of Zinc-Nickel

MEDCOM SUSTAINABILITY

73rd MORSS CD Cover Page UNCLASSIFIED DISCLOSURE FORM CD Presentation

Report No. D August 1, Internal Controls Over U.S. Army Corps of Engineers, Civil Works, Disbursement Processes

GUIDE FOR EVALUATING BLAST RESISTANCE OF EXISTING UNDEFINED ARCH-TYPE EARTH-COVERED MAGAZINES

Field Demonstration of Alternative Coatings for High Strength Steel (HSS)

Opportunities in the Mechanical Parts of the System. Dr. Thomas Kenny DARPA/MTO

Success with the DoD Mentor Protégé Program

Systems Engineering Processes Applied To Ground Vehicle Integration at US Army Tank Automotive Research, Development, and Engineering Center (TARDEC)

ASSIST Overview and Demonstration

Contractor Past Performance Information: An Analysis of Assessment Narratives and Objective Ratings. Rene G. Rendon Uday Apte Michael Dixon

Service Incentive Towards an SOA Friendly Acquisition Process

Development of a Deployable Wastewater Treatment System for Forward Operating Bases

SENSOR ENABLED WATER QUALITY AND CORROSION DEGRADATION ASSESSMENT SYSTEMS FOR WATER DISTRIBUTION NETWORKS

11. KEYNOTE 2 : Rebuilding the Tower of Babel Better Communication with Standards

Ranked Set Sampling: a combination of statistics & expert judgment

John Sullivan Shelter Technology Engineering & - Special Projects Team. Efficiency LED 2 NOV 2011 UNCLASSIFIED

Diminishing Returns and Policy Options in a Rentier State: Economic Reform and Regime Legitimacy in Saudi Arabia

DoD Environmental Information Technology Management (EITM) Program

HVOF Hard Chrome Alternatives: Developments, Implementation, Performance and Lessons Learned

Characterizing PCB contamination in Painted Concrete and Substrates: The Painted History at Army Industrial Sites

Protective Design. Force Protection Standards and Historic Preservation Policy. DoD Conservation Conference

Exploring DDESB Acceptance Criteria for Containment of Small Charge Weights

Range Sustainment: Assessing Marine Corps Operational Small Arms Ranges (SARs)

Transcription:

Solar Thermal Radiant Heating at Pohakuloa Training Area DoD Executive Agent Office Office of the of the Assistant Assistant Secretary of the of Army the Army (Installations and and Environment) Heather Brent, NDCEE/CTC The NDCEE is operated by: Technology Transition Supporting DoD Readiness, Sustainability, and the Warfighter

Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE JUN 2010 2. REPORT TYPE 3. DATES COVERED 00-00-2010 to 00-00-2010 4. TITLE AND SUBTITLE Solar Thermal Radiant Heating at Pohakuloa Training Area 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) (NDCEE),Concurrent Technologies Corporation,100 CTC Drive,Johnstown,PA,15904 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR S ACRONYM(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release; distribution unlimited 11. SPONSOR/MONITOR S REPORT NUMBER(S) 13. SUPPLEMENTARY NOTES Presented at the NDIA Environment, Energy Security & Sustainability (E2S2) Symposium & Exhibition held 14-17 June 2010 in Denver, CO. U.S. Government or Federal Rights License 14. ABSTRACT 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT a. REPORT unclassified b. ABSTRACT unclassified c. THIS PAGE unclassified Same as Report (SAR) 18. NUMBER OF PAGES 19 19a. NAME OF RESPONSIBLE PERSON Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18

Energy Situation in Hawaii Electricity rates for Pohakuloa Training Area were $0.26/kWh in 2009 and $0.35/kWh in 2008. In remote locations such as Hawaii, fossil fuel must be imported, resulting in: High utility prices Security risk for transportation. Hawaii Electric Light Company (HELCO) imports oil as majority fuel source: HELCO s 2008 Fuel Mix Fuel Sources Percentage Oil 68.0% Geothermal 18.8% Hydro 2.9% Wind 10.3% 2

Pohakuloa Training Area Pohakuloa Training Area (PTA) is a military training complex for soldiers and marines. Hosts up to 2,000 +/- at one time Can host up to 75,000 +/- personnel in a year Largest DoD Live Fire Training installation in Hawaii Located in a rural area between two volcanic mountains. Near the center of the island of Hawaii Approximately 6,800 ft elevation (PTA Base Camp) Temperatures can drop below freezing at night Photo caption: A 25th CAB CH-47D Chinook helicopter lifts one of 28 EOD-T targets for placement at one of several ranges at PTA for live-fire training. 3

PTA Billet Buildings Newly constructed Billet Buildings sleep 60 people each: Each building is 2,000 square feet Heating and cooling is provided with electric heat pump No water; latrines are provided in nearby separate building. Solar thermal radiant heat flooring project will combine solar thermal hot water system with in-floor radiant heating. Flooring heat only; no domestic water. PTA Billet Buildings 227A, B, and C Flat plate collectors combined with water storage tank will collect and store the sun s energy during the day. System will provide heat to Billet Building 227C at night. 4

What IS a solar thermal radiant heat flooring system? Main components are solar collectors, a storage tank, radiant heat emitter (flooring system), circulation pumps, thermostat, electronic controls, and a heat dissipator. This system could be modified to include domestic water heating. 5

System Design Approach Step 1: Determine the peak hourly load for the building in BTU/hr. Based on expected lowest outside temperature. Step 2: Determine the thermal storage required for the highest calculated daily load in BTU/day. Use local weather data and energy modeling software. Peak hourly load is summed over 24 hours. Step 3: Size the solar collector array. Use BTU/day calculated in Step 2. Use solar collector rating output in BTU per day. Determine number of collector panels necessary. Step 4: Choose the system type. Options include open loop, closed loop, drainback, etc. 6

System Design Approach (continued) Step 5: Plan the array layout. Options vary depending on system type (closed loop, etc.). Layout determines plumbing configuration. Step 6: Size the storage tank and heat exchangers. Amount of fluid and storage tank size can be calculated. Heat exchanger only required for domestic water heating. Step 7: Size and select the floor heating system. Using peak hourly heat load, determine circuiting of heated water tubing and floor panels (loop layout). Step 8: Size the pump skid and ancillary equipment. Calculate head losses and flow rate to size pump(s). Select expansion tank, relief valves, check valves, heat dissipation equipment, etc. 7

Daily Thermal Storage Calculations To determine the daily thermal storage for heating systems (Step 2), need to use energy simulation model such as Trane TRACE TM. TRACE is a design/analysis tool for HVAC professionals used to calculate peak cooling and heating loads, evaluate energy savings, and optimize the design of HVAC systems. Model requires local weather information files. Called TMY2 files, these are data sets of hourly values of solar radiation, temperature, humidity, and cloud cover for a 1-year period. Produced and published free by National Renewable Energy Laboratory (NREL). TMY2 files are often applicable for a large area. 8

PTA TMY2 Data File Hawaii Island has 12 distinct climate zones, but no TMY2 data file for PTA. Because there is no TMY2 data file applicable for the micro-climate at PTA, a unique TMY2 data set had to be created. TMY2 data compiled from two sources: Solar radiation data came from a State University of New York (SUNY) model for nearby Bradshaw Army Airfield at PTA. Weather data came from one of four small weather stations on PTA grounds monitored by PTA firemen. PTA Range 17 station is closest to site location and elevation. Data only recorded for one year at time; most TMY2 data files are averaged over multiple years. 9

PTA TMY2 Data File (continued) PTA Solar Data Using the SUNY data mean estimate for each hour gives average solar radiation = 481 cal/cm 2 /day. PTA Weather Data PTA Range 17 data was compiled and minor data gaps were filled in by interpolation. A pivot table was created to summarize the 8,760 hours of data into monthly Design Days. Next, data was formatted and SUNY solar radiation data was added. MS Excel file was turned into text file, then converted to TMY2 file for input into TRACE. 10

PTA Heating System Design Data loggers are currently in place at PTA to record indoor and outside temperatures and relative humidity. More data loggers will be added, including solar radiation measurement. Additional data will be used to validate PTA TMY2 data file. If successful, we may be able to publish this TMY2 data file. After creating TMY2 file, TRACE output for coldest month showed a daily heating load of 256,000 BTU/day. First calculations for thermal storage were based on a 75 F space set point and an average low temperature of 32.4 F. Revised calculations are based on a 70 F space set point and an adjusted low temperature of 23 F. The peak design load for this space set point temperature is 35,908 BTUh. 11

PTA Heating System Design (continued) Performed market analysis to compile information for various components of system Radiant heat flooring panels PEX tubing Solar collector panels. Sizing the array: Using thermal storage of 256,000 BTU/day and 4 x 10 flat panel collectors with output of 35,600 BTU/day, seven (7) collectors are necessary for 227C bldg. Selected closed loop system with heat transfer fluid. Solar collector plates will be arranged side-by-side on the southfacing pitch of roof. Racked at 30 angle to maximize winter sun. Flat plate solar collectors 12

PTA Heating System Design (continued) Flow rate for system will be approximately 8 gallons/minute. Based on flow rate and number of collectors, the storage tank should be approximately 585 gallons. Selected vertical orientation for smaller footprint and better stratification. Selected retro-fit flooring panels to be installed over existing concrete floor. One inch thick floor panels with channels cut for tubing. Roth flooring panel Consulted with Roth Industries to complete a Radiant Heating Design Summary. Piping length will be approximately 3,780 feet for Bldg 227C. 13

PTA System Design Schematic L OIICOO'!OG:~ *@''' """""'"' " 'TDlMII * C~'TJH1.1. 11\, T'tllr..M..... Dl>lli!.L.DQic:JI IPit:W.'I:CJ : en-alt... Sllull) lit t.<.. D... MECHANICAL PIPING SCHEMATIC GENERAL NOTES: 1..-u. Jftilll..:w "' vr CI7JU :;Ji~Ql..,.;) ~ 1. ~'IJE~W~.O.t'Ofr!IW!.f".ldli0.:..1 :ll!iicm Fll iti'jj)i p;a KtCPWIE ~ 5(iUITJIIIL... ~llhd' -!UrrtiJU.,~-~ iil}:i.."t[[;. s. 1UK,...,n.Ml..ntr..4~ <:: J $11G'Q.. 14

Rebates and Grants A variety of tax credits, rebates, and grants were explored, but only one option is available for this project. Hawaii Electric Company s (HECO s) Hawaii Energy Efficiency Program. This project falls under the Customized Business Incentive Rebate Program. For customers under commercial rate schedules that are not covered by other utility incentive programs. To qualify, the Customized Incentive Application and the Worksheet must be submitted to HECO. Include supporting information such as layouts, drawings, technical attachments, and/or vendor literature. Program approval is required prior to the start of work. 15

Rebates and Grants (continued) Application is being prepared for submittal to HECO. The rebate levels for the Customized Incentive Program are as follows: Rebate Levels First Year Energy Savings On-Peak Utility Demand Reduction Still unsure how rebate is paid out. Existing Facilities $0.05 per kwh saved $125 per kw reduced New Construction $0.06 per kwh saved $125 per kw reduced 16

PTA Project Status System design is complete. Structural analysis to evaluate potential wind load is being performed. Request for Proposals submitted to General Contractors. Bids turned in and being evaluated. Contract will be awarded soon to selected GC HECO Custom Rebate application is being prepared for submittal. Installation scheduled to begin September 1, 2010. Installation to be complete by October 15, 2010. 17

Path Forward Following installation, system will be monitored for one year as part of demonstration/validation (dem/val). Following dem/val, a life cycle cost and performance evaluation of the system will be completed. Stay tuned for further development 18

Points of Contact NDCEE Technical Monitor Name: Mr. Gene Arter PTA Facility Manager Organization: USAG-Hawaii Directorate of Public Works E-mail: eugene.arter@us.army.mil Phone Number: (808) 969-2480 DoD Executive Agent Office of the Assistant Secretary of the Army (Installations and Environment) NDCEE Project Manager Name: Ms. Heather Brent, Sustainability Engineer Organization: CTC E-Mail: brenth@ctc.com Phone Number: (412) 992-5352 www.ndcee.ctc.com This work was funded through the Office of the Assistant Secretary of the Army (Installations and Environment) and conducted under contract W74V8H-04-D-0005 Task 0561-A2. The views, opinions, and/or findings contained in this paper are those of the author(s) and should not be construed as an official Department of the Army position, policy, or decision unless so designated by other official documentation. 19