Simultaneous in vivo Quantification and Metabolite Identification of Plasma Samples Using High Resolution QTof and Routine MS E Data Analysis

Similar documents
Informatics and High Resolution QTof MS. How can we ask better questions and get better answers in DMPK? Mark D. Wrona

Metabolite Identification Workflows: A Flexible Approach to Data Analysis and Reporting

Using WinNonlin with UNIFI: Enhanced Export for the Metabolite Identification Application Solution

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

[ WHITE PAPER ] High Throughput Microflow LC-MS: Sensitivity Gains on a Practical Timescale ABSTRACT INTRODUCTION

Targeted and Untargeted Screening of Microcystins in Lake Water Samples Using High Resolution Mass Spectrometry INTRODUCTION

Xevo G2-S QTof and TransOmics: A Multi-Omics System for the Differential LC/MS Analysis of Proteins, Metabolites, and Lipids

High throughput analysis at microscale: performance of ionkey/ms with Xevo G2-XS QTof under rapid gradient conditions

High throughput analysis at microscale: performance of ionkey/ms with Xevo G2-XS QTof under rapid gradient conditions

Waters Solutions for DMPK and Biomarker Analysis. Waters User Meeting ASMS 2011 Denver, Colorado. Stephen McDonald

UPLC/MS/MS Method for the Quantification of Trastuzumab in Human Serum at the 5-nM Level Using Xevo TQD MS and ACQUITY UPLC H-Class System

How discovery activities can influence metabolic profiling in the regulatory space? C. DELATOUR EBF, 25 th September 2015

Tabisam Khan 1, David R. Little 1, Liyu Yang 2, Jiwen Chen 2, Parya Nouri 2, Samy Tadros 2, Patrick J. Rudewicz 2

6 applications that will make a difference in your bioanalytical lab

BIOANALYTICAL STRATEGY FOR IN VITRO METABOLITE SCREENING WITH EXACT MASS USING THE Q-Tof micro. Jose M. Castro-Perez 1, Carina Leandersson 2

Dried Blood Spot Analysis From The Clinic To The Laboratory

UNIFI: an innovative enabling platform Ken Eglinton Nordic User Training, September 2013

A Sensitive and Robust Method for the Quantification of Goserelin in Plasma Using Micro-Elution Plates

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

Development of a Clinical Research Method for the Measurement of Testosterone. Dihydrotestosterone

Online UPLC Method for the Support of Cleaning Validation and the Routine Monitoring of Cleaning Procedures

Microflow LC-MS with the turn of a key

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Encompassing Method Development, Small Scale Purification, and Post-Purification Analysis with the Investigator SFC System

Metabolite ID. Introduction

DETERMINATION OF PROTEIN BINDING BY UPLC/MS/MS

[ VION IMS QTOF ] BEYOND RESOLUTION

Pharmaceutical LC/MS Solutions from Agilent Technologies

Illicit Drug Analysis in Urine Using 2D LC-MS/MS for Forensic Toxicology

Improving Resolution and Column Loading Systematically in Preparative Liquid Chromatography for Isolating a Minor Component from Peppermint Extract

ENHANCED MS WITH THE TURN OF A KEY

Pharmacokinetic Analysis of the mab Adalimumab by ELISA and Hybrid LBA/LC/MS: A Comparison Study

DRUG DISCOVERY & 2 September 2010

Introduction. Benefits of the SWATH Acquisition Workflow for Metabolomics Applications

MRM Analysis of a Parkinson s Disease Protein Signature

Method Development of a 2D LC-HRMS Extraction and Detection Method for Organophosphorus Flame Retardants in Environmental Water Samples

Robustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety

Eoin F.J. Cosgrave, Matthew A. Lauber, Robert Birdsall, and Sean M. McCarthy Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION

World-leading LC/MS/MS technology for quantitation and identification API LC/MS/MS System

BIOANALYSIS CONSUMABLE SOLUTIONS. Sample Preparation and Liquid Chromatography Solutions for Quantitative BIOANALYSIS

Simultaneous Quantitation of a Monoclonal Antibody and Two Proteins in Human Plasma by High Resolution and Accurate Mass Measurements

Absolute Quantification of Yeast Kinases by LC/MS/MS using QconCAT and MRM Technologies

Drug Metabolism and Disposition. Supplement Materials

PESTICIDE SCREENING APPLICATION SOLUTION

Thermo Scientific Compound Discoverer Software. Integrated solutions. for small molecule research

TechnicalNOTE METABOLYNX EXACT MASS DEFECT FILTER: RAPIDLY DISCRIMINATE BETWEEN TRUE METABOLITES AND FALSE POSITIVES INTRODUCTION

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

ACQUITY Arc VERSATILITY WITHOUT COMPROMISE

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1

FUTURE-PROOF SOLUTIONS FOR REGULATED LABORATORIES IN THE FACE OF CHANGING USP <621> GUIDELINES

Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics

IMPLEMENTATION OF PANORAMA INTO DAILY WORKFLOWS AND QUANTITATIVE PROTEIN PK ANALYSIS IN THE PHARMACEUTICAL SETTING

Application Note # ET-20 BioPharma Compass: A fully Automated Solution for Characterization and QC of Intact and Digested Proteins

IMPORTANCE OF CELL CULTURE MEDIA TO THE BIOPHARMACEUTICAL INDUSTRY

of peptide mapping chemistries, 130Å or 300Å with tunable UV, photodiode array, or mass spectrometry

John Mehl, Bogdan Sleczka, Eugene Ciccimaro, Christian Caporuscio, Ekaterina Deyanova, Richard Huang, Timothy Olah, Celia D Arienzo

Waters QUATTRO PREMIER XE

High Speed, Ultra-High Sensitivity, and Robustness Needed for the Quantitation of Pharmaceuticals in Blood Plasma. Application Note. Authors.

Waters Pesticide Screening Solutions: Nuove Frontiere nell Analisi di pesticidi Miguel Ángel Cortés, Waters Manuela Cuccurullo, Waters

Method Development Considerations for Reversed-Phase Protein Separations

New Approaches to Quantitative Proteomics Analysis

and for the Development of Isolation Strategies

[ APPLICATION NOTE ] Determination of Acidic Herbicides in Water Using Liquid Chromatography-Tandem Quadrupole Mass Spectrometry APPLICATION BENEFITS

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

Application Note. Kwasi Antwi, Amanda Ribar, Urban A. Kiernan, and Eric E. Niederkofler Thermo Fisher Scientific, Tempe, Arizona

From routine to research, always the right answers.

HARMONIZATION TEAM A6 (STABILITY) UPDATE. Yoshiaki Ohtsu 8 March 2012

Sean M. McCarthy and Martin Gilar Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL RESULTS AND DISCUSSION

MultiQuant Software 2.0 with the SignalFinder Algorithm

Key Words Q Exactive Focus, SIEVE Software, Biomarker, Discovery, Metabolomics

Simplifying ImmunoAffinity Capture Workflow

Technical Note CYP Inhibition Assays: Versatility in the ADDA High Speed Dual Arm Autosampling System

Improving Sensitivity in Bioanalysis using Trap-and-Elute MicroLC-MS

[ ANALYTICAL SERVICES SOLUTIONS ] constant DEADLINES... FASTER THAN EVER BEFORE.

Multi-Enzyme Digestion for Biotherapeutic Peptide Mapping: Examining BiopharmaLynx 1.3 Functionality

How to Manage Metabolite Profiling Requests, the CRO Perspective. Dr Martha A Green Manager Qualitative Mass Spectrometry Charles River, Edinburgh

Improving Sensitivity for an Immunocapture LC-MS Assay of Infliximab in Rat Plasma Using Trap-and-Elute MicroLC-MS

ACCURACY THE FIRST TIME. Reliable testing with performance, productivity and value combined AB SCIEX 3200MD SERIES MASS SPECTROMETERS

Asish Chakraborty, St John Skilton, Weibin Chen and John C. Gebler Waters Corporation, Milford, MA, U.S. INTRODUCTION METHODS. Sample preparation

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Isotopic Resolution of Chromatographically Separated IdeS Subunits Using the X500B QTOF System

Techniques for Improving the Efficiency of Large Volume Loading in Preparative Liquid Chromatography

Spectronaut Pulsar X. Maximize proteome coverage and data completeness by utilizing the power of Hybrid Libraries

Increasing Throughput and Efficiency with Exactive LC/MS and Triple Quadrupole LC/MS/MS

Title: Non-absorbable apple procyanidins prevent obesity associated with gut microbial

A Novel Screening Method for Anthropogenic Sewage Pollutants in Waste Water, Ground Water and Drinking Water Samples by LC HRAM Analysis

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

Overview of Waters Solutions for Biopharmaceutical Analysis and Characterization

Pushing the Leading Edge in Protein Quantitation: Integrated, Precise, and Reproducible Protein Quantitation Workflow Solutions

[ MS IMAGING ] FULL SPECTRUM MOLECULAR IMAGING COMPLETE VISUALIZATION OF MOLECULAR DISTRIBUTIONS

Universal Solution for Monoclonal Antibody Quantification in Biological Fluids Using Trap-Elute MicroLC-MS Method

A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery Using HPLC-Chip/ MS-Enabled ESI-TOF MS

Automatic Combination of Orthogonal Separation Modes for Multiple Components in Mixtures

Trastuzumab Glycan Batch-to-Batch Profiling using a UPLC/FLR/Mass Spectrometry Platform

MRG: Metabolomics Research Group

A High-Resolution, Accurate-Mass Approach for Ultra-High Throughput Screening Plasma Protein Binding

[ product solution ] Waters Oasis µ Elution PlateS. Patented Innovation. Elution volume as low as 25 μl. No evaporation and reconstitution

Biotherapeutic Peptide Mapping Information Dependent Acquisition (IDA) Method

Transcription:

Simultaneous in vivo Quantification and Metabolite Identification of Plasma Samples Using High Resolution QTof and Routine MS E Data Analysis Mark Wrona, 1 Paul Rainville, 1 Eric Langlois, 2 Nigel Ewing, 3 and Julie Laterreur 2 1 Waters Corporation, Milford, MA, USA 2 Vertex Biopharmaceuticals, Cambridge, MA, USA 3 Vertex Biopharmaceuticals, Laval, Quebec, Canada A P P L I C AT ION B E N E F I T S Selectivity and specificity of accurate mass for quantification Discovery bioanalysis Quan/Qual Metabolite identification INT RO DU C T ION QTof mass spectrometry platforms have long been used in DMPK groups to understand complex metabolic pathways and provide support for key activities, including metabolic hotspot screening, generating preclinical animal and in vitro in vivo correlation (IVIVC) information, supporting first-in-man dosing, and providing support for regulatory submission. Advances in sensitivity, detector linear response, and robustness have opened up the possibility for QTof MS platforms to be a viable alternative for use in bioanalysis laboratories with traditional use tandem quadrupole MS platforms (also referred to as triple quadrupole, or QQQ). There is strong interest to develop workflows that not only provide robust and accurate quantitative information on the parent compound, but that also simultaneously collect additional information about metabolism or other potential pharmacodynamic (PD) markers, ultimately providing data for DMPK scientists containing accurate quantitative data with rich qualitative information to inform and drive programs. The flexibility of QTof platforms for quan/qual analysis allows for both a better alignment with QQQ information and workflows, and the potential to complement as well as shift workflows and assays to high resolution MS (HRMS) for value added DMPK programs. WAT E R S SO LU T IONS Metabolite Identification Application Solution with UNIFI Xevo G2 QTof Mass Spectrometer UNIFI Scientific Information System K E Y W O R D S Drug discovery, DMPK, quan/qual, accurate mass, exact mass, MS E, WinNonLin, in vivo PK, collaboration In this example, propranolol was used as a model compound and a pharmacokinetic (PK) rat study (containing standard curves, PK runs, and QCs) was conducted by Vertex Pharmaceuticals using a Xevo G2 QTof MS System for analysis. The sample set was also run at Vertex using a triple quadrupole platform with a typical MRM-based workflow under the same chromatographic conditions to provide a reference comparison data set. This application note summarizes the collaboration between Vertex and Waters to test and demonstrate a quan/qual workflow to determine robustness and reliability of QTof measurements, and compare them against the gold-standard tandem quadrupole workflows. This work was presented as an oral presentation at ASMS 2012 in Vancouver, Canada on May 20, 2012. 1

E X P E R IM E N TA L Four rats (Sprague-Dawley) were dosed PO with propranolol (75 mg/kg) by the Vertex DMPK discovery group using typical dosing protocols. Rat plasma was collected over 24 hours (predose, 15 minutes, 30 minutes, 1.0 hour, 1.5 hours, 2.0 hours, 4.0 hours, 6.0 hours, and 24.0 hours). Three sets of QCs and bracketed full standard curves (0.1 ng/ml to 10.0 ng/ml) were also analyzed. All time points for the four rats were pooled time points, with the goal of the study to test platform variability rather than biology variability. All samples were processed using 5:1 protein precipitation with acetonitrile + 0.1% formic acid containing internal standard (IS propranolol-d7), and diluted 1:1 with water prior to injection. Samples were analyzed using a ballistic gradient (ACQUITY UPLC BEH C 18 1.7 µm, 2 x 50 mm, 5% to 95% B over two minutes, A: water + 0.1% formic acid, B: acetonitrile + 0.1% formic acid, 0.5 ml/min, column temperature at 35 C, four-minute total runtime including re-equilibration). An injection volume of 5 µl was used. R E SU LT S A N D D IS C U S S ION The standard curve of propranolol prepared in plasma is shown in Figure 1. Both the QTof and QQQ platform produce r 2 correlation values >0.99 over the entire tested range (2.5 to 10,000 ng/ml) meeting basic discovery bioanalysis acceptance criteria of +/- 20% for all Standard Curve and QC values reported. Both platforms were able to detect standards below 2.5 ng/ml, however the deviations exceeded 20% and were not reported. The standard curves reported for both platforms are virtually indistinguishable. QQQ R 2 = 0.9972 QToF R 2 = 0.9985 Figure 1. Standard curve comparison by platform: QTof versus tandem quadrupole MS (QQQ), and measured versus reported concentrations. A tandem quadrupole Thermo Scientific Quantum Ultra mass spectrometer and a Waters Xevo G2 QTof MS System were utilized at Vertex. The tandem quadrupole was run in MRM mode under typical discovery bioanalytical conditions. Data for the QTof was collected using MS E mode, where full scan and full scan fragmentation data are collected simultaneously. Software deconvolution is used to align and provide precursor and fragmentation ion information for all detected components in the mixture in a generic fashion. QTof data were processed locally using MassLynx Software and its TargetLynx Application Manager, and were subsequently processed at Waters using the UNIFI Scientific Information System for quan/qual approaches. 2

QCs were evaluated at four different concentrations: 7, 70, 700, and 7000 ng/ml to cover the range of the evaluated compound. Figure 2 shows the QC results of the analyses by platform. The same QC failed on both platforms, and was excluded during run three. QQQ QTof Measured %dev Measured %dev Run 1 7.8 11.7 7.4 5.4 67.7-3.3 68.6-2.0 661.3-5.5 664.2-5.1 6550.5-6.4 6915.7-1.2 Run 2 7.8 11.5 8.2 17.5 80.7 15.3 75.3 7.6 794.7 13.5 776.0 10.9 7913.2 13.0 7785.0 11.2 Run 3 n/a n/a n/a n/a 79.1 13.0 79.4 13.4 783.0 11.9 760.9 8.7 7290.7 4.2 7714.8 10.2 Average 7.8 0.2 7.8 0.6 75.8 9.4 74.4 7.3 746.3 9.9 733.7 8.3 7251.5 9.4 7471.8 6.5 Figure 2. QCs (7, 70, 700, and 7000 ng/ml) compared by platform. 3

Figure 3 shows the PK curves plotted for the two platforms. Areas under the curve (AUCs) for both platforms generated nearly identical profiles. The data derived from each platform would provide the same information to DMPK program teams working on a project. Measured concentration 1200 1000 800 600 400 QQQ QToF 200 0 0.00 5.00 10.00 15.00 20.00 Time Figure 3. PK curves, overlay of the QTof and tandem quadrupole data. Additional PK values were calculated for both data sets and reported using Phoenix WinNonLin 13 (Pharsight Software, St. Louis, USA). Concentration values were evaluated by using NCA analysis to determine key PK parameters. Log plots and WinNonLin output is shown in Figure 4. Noncompartmental Analysis (NCA) analysis with automatic best-fit parameters and linear trapezoidal linear interpolation parameters were used and AUCs, area under the moment curve (AUMCs), and half-lives (t ½) were calculated (Figure 4). All reported values for the two instruments were within 7.2% of each other, providing a high degree of confidence that the data reported from either platform would offer the same level of information for a given study. Figure 4. PK analysis in WinNonLin. A comparison of tandem quadrupole (QQQ) and QTof MS data. 4

Although much of the work contained in this application note compares the data between HRMS and QQQ platforms for quantitative purposes, there is additional information inherently present in an HRMS PK data set. Once we know what is happening to the parent compound, we extract additional information about the production of phase I and phase II metabolism. Furthermore, we can relate this information back to the stability of the parent compound and/or potentially provide early indication of long-lived metabolites that may need further profiling. Figure 5 shows trendplots for propranolol as well as two major metabolites present in the PK samples. The benefit of HRMS is now revealed, along with full PK bioanalytical data, many metabolites were observed, 5 +O, 2 +O 2, 2 +glucuronide, 3 +O +glucuronide, and additional cleavage products were easily detected and tracked as circulating metabolites in these samples. These metabolites can also be tracked by MRM, however HRMS full scan techniques offer a distinct advantage by easily and confidently identifying metabolic pathways over tandem quadrupole technologies with high precursor mass specificity and fragment ion confirmations. Extensive method development and development or prediction of MRMs is avoided and a true representative picture of metabolism is obtained on the first injection with access to XICs and spectral information for all components. Figure 5. Trendplots in UNIFI for HRMS QTof data set across all samples: A) parent compound, propranolol showing Std Curve, QCs, and PK profiles; B) major hydroxylated metabolite, only seen in PK samples; and C) major hydroxylated and glucuronidated species observed in PK samples. 5

C O N C LUSIONS HRMS has been shown to be fully capable of providing both quantitative and qualitative data sets. The sensitivity afforded by the HRMS platform was sufficient to define the PK curve for a model compound dosed in rats. Linearity of the HRMS instrument was highly comparable to the tandem quadrupole MS (QQQ) in this study and was more than adequate for performing the rat PK analysis. Major metabolites could be easily detected and monitored over the time course with HRMS data, proving useful for determining the fate of parent in vivo. Informatics packages such as UNIFI will bridge these historically disparate workflows, and provide tools to process and visualize quantitative and qualitative data simultaneously. Waters, Xevo, UNIFI, ACQUITY, and MassLynx are registered trademarks of Waters Corporation. TargetLynx and The Science of What s Possible are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 2013 Waters Corporation. Produced in the U.S.A. May 2013 720004723EN AG-PDF Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com