FROM: PROPOSED SUBSTITUTION: Use HILTI X-CW Ceiling Wire for Suspended Ceiling Systems

Similar documents
CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

ESR-2269 Reissued November 1, 2008 This report is subject to re-examination in one year.

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

ESR ICC Evaluation Service, Inc. Reissued September 1, 2008 This report is subject to re-examination in one year.

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW VELOCITY X-U AND X-U 15 UNIVERSAL FASTENERS AND X-P CONCRETE FASTENERS

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

where: P s = Applied service tension load, pounds (kg). P t V s V t

FROM: PROPOSED SUBSTITUTION: Use HILTI X-U instead of fillet weld or arc spot puddle weld

CITY OF LOS ANGELES CALIFORNIA

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

CITY OF LOS ANGELES CALIFORNIA

ESR-2036 Reissued May 1, 2013 This report is subject to renewal June 1, 2015.

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA

To: Firm: Project: Product Specified: Specified Location:

FROM: SUBJECT: HILTI X-ENP-19, X-HSN 24 or X-U POWDER-ACTUATED FASTENER SUBSTITUTION REQUEST

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 100 PLANO, TEXAS 75024

Trusted ICC ES HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

CITY OF LOS ANGELES CALIFORNIA

*Corrected October 2005

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

Product Submittal/Substitution Request

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code.

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: HILTI, INC.

ESR ICC Evaluation Service, Inc. Reissued July 1, 2006 This report is subject to re-examination in two years.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: KWIK BOLT TZ MASONRY ANCHORS

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: 5956 WEST LAS POSITAS BOULEVARD PLEASANTON, CALIFORNIA 94588

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC.

Hilti, Inc South 122 nd East Avenue Tulsa, OK

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

CITY OF LOS ANGELES CALIFORNIA

ESR ICC Evaluation Service, Inc. Reissued January 1, 2008 This report is subject to re-examination in one year.

For acoustical applications and suspended ceiling systems or light fixtures. Several styles of angled clips with pre-mounted pins.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS DIVISION: CONCRETE ANCHORS REPORT HOLDER: DEWALT

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: POWERS FASTENERS, INC. 701 EAST JOPPA ROAD TOWSON, MARYLAND 21286

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES REPORT HOLDER: NELSON STUD WELDING, INC WEST RIDGE ROAD ELYRIA, OHIO 44036

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT

ICC-ES Evaluation Report. ESR-3342 Reissued July 1, 2013 This report is subject to renewal August 1, 2015.

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

The following excerpt are pages from the North American Anchor Fastening Technical Guide, 2011.

REPORT HOLDER: ispan SYSTEMS LP 70 BRENTWOOD DRIVE PRINCETON, ONTARIO N0J 1V0 CANADA EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

ESR ICC Evaluation Service, Inc. Issued March 1, 2006 This report is subject to re-examination in one year.

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: AKRON PRODUCTS COMPANY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

DIVISION: WOOD, PLASTICS, AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

ESR-1812 Reissued October 1, 2012 This report is subject to renewal November 1, 2013.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

ICC-ES Evaluation Report

LEGACY REPORT DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

CALIFORNIA ERIC GARCETTI MAYOR

DIVISION: METALS SECTION: METAL FASTENINGS DIVISION: FINISHES SECTION: FASTENERS REPORT HOLDER: HILTI, INC.

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: MASON WEST, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC. EVALUATION SUBJECT: GRABBER FASTENERS FOR USG STRUCTURAL PANELS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: ITW RED HEAD 700 HIGH GROVE BOULEVARD GLENDALE HEIGHTS, ILLINOIS 60139

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

TITEN HD Heavy Duty Screw Anchor for Concrete & Masonry

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: TENDON SYSTEMS, LLC

Transcription:

DATE: PROJECT: TO: FROM: SUBJECT: HILTI X-CW CEILING WIRE FASTENER SUBSTITUTION REQUEST SPECIFICATION TITLE: SECTION: PAGE: ARTICLE/PARAGRAPH: DESCRIPTION: DESIGN DETAIL NO.: PROPOSED SUBSTITUTION: Use HILTI X-CW Ceiling Wire for Suspended Ceiling Systems PRODUCT DESCRIPTION: The Hilti X-CW Ceiling Wire Fastening Assembly consists of a premounted powder-actuated fastener, either X-U or X-C type, with a pre-mounted 0.06 in. (1.5 mm) thick steel clamping washer and a 12 gauge (0.106in/2.7 mm) diameter galvanized, soft annealed mild carbon steel wire for supporting direct and indirect suspended lay-in panel ceilings. SUBMITTED BY: SUPPORTING DATA ATTACHED: 2009 SUPPLEMENT TO HILTI PRODUCT TECHNICAL GUIDE, 2008 ICC EVALUATION SERVICE REPORT ESR-2892 FASTENER LOAD COMPARISONS SAMPLES PRICING INFORMATION A/E REVIEW AND ACTION: SUBSTITUTUTION APPROVED SUBSTITUTION APPROVED AS NOTED SUBSTITUTION REJECTED COMMENTS: SIGNED BY: DATE: Hilti, Inc. 5400 South 122 nd East Avenue Tulsa, OK 74146 1-800-879-8000 www.us.hilti.com

October 23, 2009 Subject: IBC / IRC Compliance of Hilti X-CW Ceiling Wire Assemblies (ICC-ES ESR-2892) To Whom It May Concern: This memorandum addresses the 2006 IBC (International Building Code) and IRC (International Residential Code) compliance of Hilti X-CW Ceiling Wire Assemblies. Hilti X-CW Ceiling Wire Assemblies consist of a pre-mounted Hilti powder-actuated fastener, X-U (ICC-ES ESR-2269) or X-C (ICC-ES ESR-1663) type, with a pre-mounted clamping washer and a 12 gauge soft annealed mild carbon steel wire for supporting direct and indirect hung suspended lay-in panel ceilings. Hilti X-CW Ceiling Wire Assemblies have been tested and evaluated by ICC-ES in accordance with AC70-07, Acceptance Criteria for Fasteners Power-Driven into Concrete, Steel, and Masonry Elements in order to provide recognition under 2006 IBC and IRC. Hilti X-CW Ceiling Wire Assemblies are recognized in evaluation service report ESR-2892 issued by ICC-ES, and meet the OSHPD and DSA requirements for fastening of acoustical lay-in panel suspended ceiling systems, subject to the conditions of OSHPD CAN 2-1912A.1 and DSA IR 25-2. X-CW Ceiling Wire Assemblies are an alternative method of fastening for acoustical suspended ceiling systems as referenced in ASTM C635, which is referenced in Section 809.3 of 2006 IBC, and may be substituted for Hilti X-CC type Ceiling Clips (ICC-ES ESR-2184) if allowable service load requirements are satisfied. For additional information or inquiries, please contact Hilti Technical Services at hnatechnicalservices@hilti.com or call 1-800-749-6337. Regards, William G. Gould, P.E. Director, Codes and Approvals Hilti, Inc. (800) 879-6000 x-7804 william.gould@hilti.com Ref. ICC-ES AC70 Acceptance Criteria for Concrete, Steel and Masonry Elements, 1-1-07 OSHPD CAN 2-1912A.1 Qualification, Design and Use of Anchors Installed in Concrete, 7-1-08 DSA IR 25-2 Metal Suspension Systems for Lay-In Panel Ceilings, 7-21-05 Hilti, Inc. 5400 South 122 nd East Avenue Tulsa, OK 74146 1-800-879-8000 www.hilti.com

ICC-ES Evaluation Report ESR-2892 Issued October 1, 2009 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 03 CONCRETE Section: 03151 Concrete Anchoring DIVISION: 09 FINISHES Section: 09051 Fasteners REPORT HOLDER: HILTI, INC. 5400 SOUTH 122ND EAST AVENUE TULSA, OKLAHOMA 74146 (800) 879-8000 www.us.hilti.com EVALUATION SUBJECT HILTI X-CW CEILING WIRE ASSEMBLIES 1.0 EVALUATION SCOPE Compliance with the following codes: # 2006 International Building Code (IBC) # 2006 International Residential Code (IRC) # 2003 International Building Code (2003 IBC)* # 2003 International Residential Code (2003 IRC)* # 2000 International Building Code (2000 IBC)* # 2000 International Residential Code (2000 IRC)* # 1997 Uniform Building Code (UBC)* *Codes indicated with an asterisk are addressed in Section 8.0. Property evaluated Structural 2.0 USES Hilti X-CW ceiling wire assemblies are used to fasten steel wire to normal-weight concrete and structural sandlightweight concrete filled metal deck for the purpose of hanging suspended ceiling systems complying with IBC Section 803.9. The fasteners may be used where an engineered design is submitted in accordance with IRC Section R301.1.3. 3.0 DESCRIPTION 3.1 General: The Hilti X-CW Ceiling Wire Assembly consists of a steel wire clamped to a powder-actuated fastener with a premounted clamping washer, as shown in Figure 1. See Table 1 for assembly types and fastener dimensions. 3.2 Powder-actuated fastener: The powder-actuated fasteners used in the X-CW assemblies are the Hilti X-C and X-U fasteners, recognized in ESR-1663 and ESR-2269, respectively. 3.3 Clamping Washer: The premounted clamping washer is formed from steel complying with ASTM A 653M SS, Grade 255, with a Z120 coating designation. The steel has a base-metal thickness of 0.06 inch (1.5 mm). 3.4 Wire: The ceiling wire is No. 12 gage [0.106 inch (2.7 mm)] diameter, zinc-coated carbon steel wire complying with ASTM A 641, soft temper, with a Class 1 zinc coating designation. 4.0 DESIGN AND INSTALLATION 4.1 Design: The allowable tension and 45-degree-angle loads for X- CW ceiling wire assemblies installed into normal-weight concrete are provided in Table 2. The allowable tension and 45-degree-angle loads for X-CW ceiling wire assemblies installed through metal deck into structural sand-lightweight concrete are provided in Table 3. For installation at angles between 45 degrees and 90 degrees to the supporting slab, the allowable load is the lesser of the allowable tension and 45-degree-angle loads. The stress increases described in Section 1605.3 of the IBC are not allowed for wind loads acting alone or when combined with vertical loads. No increase is allowed for vertical loads acting alone. Use of fasteners to resist earthquake loads is outside the scope of this report. 4.2 Installation: 4.2.1 General: The X-CW ceiling wire assemblies must be installed in accordance with this report and the manufacturer s published installation instructions, including those shown in Figure 2. A copy of these instructions must be available on the jobsite at all times during installation. Installation must be limited to dry, interior locations. Fastener placement requires the use of a low-velocity powder-actuated tool in accordance with Hilti recommendations. Fastener standoff distance must be as noted in the footnotes to the tables and as shown in Figure 2. Installers must be certified by Hilti. 4.2.2 Fastening to Concrete: Fasteners must be driven into the concrete after the concrete attains the specified concrete compressive strength. Minimum spacing between fasteners must be 4 inches (102 mm) and minimum edge ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, Inc., express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2009 Page 1 of 4

ESR-2892 Most Widely Accepted and Trusted Page 2 of 4 distance must be 3 inches (76 mm). Unless otherwise noted in this report, concrete thickness must be a minimum of three times the embedment depth of the fastener. 4.2.3 Fastening to Structural Sand-lightweight Concrete Filled Steel Deck: Installation in structural sandlightweight concrete filled steel deck must comply with Figure 3. Minimum distance from fastener centerline to rolled deck flute edges must be as depicted in Figure 3. 5.0 CONDITIONS OF USE The Hilti X-CW ceiling wire assemblies described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The fasteners are manufactured and identified in accordance with this report. 5.2 Fastener installation complies with this report and the Hilti, Inc., instructions. In the event of conflict between this report and Hilti, Inc., published instructions, this report governs. 5.3 Allowable tension and 45-degree values are as noted in Tables 2 and 3. The stress increases and load reductions described in Section 1605.3.2 of the IBC are not allowed for wind loads acting alone or when combined with gravity loads. No increase is allowed for vertical loads acting alone. 5.4 Calculations demonstrating that the applied loads are less than the allowable loads described in this report must be submitted to the code official for approval. The calculations must be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is constructed. 5.5 Use of fasteners to resist earthquake loads is outside the scope of this report. 5.6 The use of fasteners is limited to installation in uncracked concrete. Cracking occurs when f t > f r due to service loads or deformations. 5.7 Use of fasteners is limited to dry, interior locations. 5.8 Installers must be certified by Hilti and have a current, Hilti-issued, operator s license. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Fasteners Power-driven into Concrete, Steel and Masonry Elements (AC70), dated October 2006. 6.2 Report of testing of hanger wire connection to fastener, in accordance with the ICC-ES Acceptance Criteria for Suspended Ceiling Framing Systems (AC368), dated February 2007. 7.0 IDENTIFICATION The fasteners are imprinted with an H on the head. All assemblies are identified on the packaging with the Hilti, Inc., name, the fastener type and size, and the evaluation report number (ESR-2892). 8.0 OTHER CODES 8.1 Evaluation Scope: In addition to the codes referenced in Section 1.0, the products in this report were evaluated for compliance with the requirements of the following codes: # 2003 International Building Code (2003 IBC) # 2003 International Residential Code (2003 IRC) # 2000 International Building Code (2000 IBC) # 2000 International Residential Code (2000 IRC) # 1997 Uniform Building Code (UBC) 8.1 Uses: See Section 2.0. The fasteners may be used where an engineered design is submitted in accordance with 2003 IRC Section R301.1.3 or 2000 IRC Section R301.1.2, as applicable. 8.2 Description: See Section 3.0. 8.3 Design and Installation: 8.3.1 Design: See Section 4.1 and the following: The stress increases described in Section 1612.3.2 of the UBC are not allowed for wind loads acting alone or when combined with gravity loads. Use of fasteners to resist earthquake loads is outside the scope of this report. 8.3.2 Installation: See Section 4.2. 8.4 Conditions of use: See Section 5.0. 8.5 Evidence Submitted: See Section 6.0. 8.6 Identification: See Section 7.0.

ESR-2892 Most Widely Accepted and Trusted Page 3 of 4 CEILING WIRE ASSEMBLY TYPE FASTENER DIAMETER (inch) TABLE 1 X-CW CEILING WIRE ASSEMBLY TYPES FASTENER SHANK LENGTH (inches) RELEVANT BASE MATERIAL MINIMUM EMBEDMENT OF FASTENER (inches) X-CW X-C 27 0.138 1.063 X-CW X-C 32 0.138 1.260 Normal-weight concrete, 1 1 / 8 Lightweight concrete X-CW X-U 22 0.157 0.866 over metal deck / 4 X-CW X-U 27 0.157 1.063 7 / 8 For SI: 1 inch = 25.4 mm. 7 / 8 CEILING WIRE ASSEMBLY TYPE X-CW X-C 27 TABLE 2 ALLOWABLE LOADS FOR HILTI X-CW CEILING WIRE ASSEMBLIES INSTALLED IN NORMAL-WEIGHT CONCRETE (pounds) 1,2 MINIMUM EMBEDMENT (inches) CONCRETE COMPRESSIVE STRENGTH 4000 psi 6000 psi Tension 45-Degree Tension 45-Degree 7 / 8 210 210 --- --- X-CW X-C 32 1 1 / 8 210 210 --- --- X-CW X-U 22 X-CW X-U 27 For SI: 1 inch = 25.4 mm, 1 lbf = 4.4 N, 1 psi = 6895 Pa. 3 / 4 --- --- 100 90 7 / 8 210 210 130 150 1 Allowable values are for fasteners installed in concrete having the designated compressive strength at the time of installation. 2 Concrete thickness at the point of penetration must be a minimum of three times the fastener embedment depth. CEILING WIRE ASSEMBLY TYPE X-CW X-C 27 TABLE 3 ALLOWABLE LOADS FOR HILTI X-CW CEILING WIRE ASSEMBLIES INSTALLED IN STRUCTURAL SAND-LIGHTWEIGHT CONCRETE FILLED COMPOSITE STEEL DECK (pounds) 1,2 MINIMUM EMBEDMENT (inches) 3000 PSI CONCRETE COMPRESSIVE STRENGTH Upper Flute Lower Flute Tension 45-Degree Tension 45-Degree 7 / 8 110 210 100 145 X-CW X-C 32 1 1 / 8 150 210 100 145 X-CW X-U 27 For SI: 1 inch = 25.4 mm, 1 lbf = 4.4 N, 1 psi = 6895 Pa. 7 / 8 170 210 150 160 1 Allowable values are for fasteners installed in concrete having the designated compressive strength at the time of installation. 2 The composite floor deck must have a minimum thickness of 20 gage (0.0358 inch) and a minimum yield strength (F y ) of 38 ksi. Figure 3 shows nominal flute dimensions, fastener locations and load orientations for the deck profile. Structural sand-lightweight concrete fill above top of steel deck must be a minimum of 3 1 / 4 inches thick. Pre-mounted X-U or X-C fastener (X-U Shown) Pre-mounted steel clamping washer Pre-mounted Ceiling Wire Hanger FIGURE 1 X-CW CEILING WIRE ASSEMBLY IDENTIFICATION

ESR-2892 Most Widely Accepted and Trusted Page 4 of 4 Insert X-CW Ceiling Wire Assembly Into the Hilti Powder Actuated Tool Locate the Fastening, Compress the Hilti Powder-Actuated Tool and Install Fastener Check Nail Standoff and Adjust the X-CW Ceiling Wire Position as Needed FIGURE 2 X-CW CEILING WIRE ASSEMBLY INSTALLATION INSTRUCTIONS FIGURE 3 HILTI X-CW CEILING HANGER ASSEMBLY LOCATION IN 3-INCH-DEEP COMPOSITE FLOOR DECK, NORMAL DECK PROFILE ORIENTATION

X-CW Ceiling Wire Fastening Assemblies 2009 Supplement to Hilti North American Product Technical Guide, 2008 Edition 2009 Edition

Direct Fastening Systems Hilti X-CW Ceiling Wire Assembly 1.1 Product Description The Hilti X-CW Ceiling Wire Fastening Assembly consists of a pre-mounted powder-actuated fastener, either X-U or X-C type, with a pre-mounted 0.06 in. (1.5 mm) thick steel clamping washer and a 12 gauge (0.106 in./2.7 mm) diameter galvanized, soft annealed mild carbon steel wire for supporting direct and indirect hung suspended lay-in panel ceilings. 1.1 Product Description 1.2 Material Specifications 1.3 Technical Data 1.4 Installation Instructions 1.5 Ordering Information 1.2 Material Specifications Powder- Powder- Steel Steel Fastener Actuated Actuated Clamping Clamping Ceiling Ceiling Designation Fastener Fastener Washer Washer Wire Wire Material Plating Material Plating Material Plating Carbon X-CW 5 μm Zinc Carbon 1 16 μm Zinc Carbon 2 6 μm Zinc Steel Steel Steel 3 1 ASTM B 633, SC 1, Type III 2 ASTM A 653/A 653M, Z120 3 ASTM A 641/A 641M, Class 1 1.3 Technical Data Allowable Loads for Hilti X-CW Ceiling Wire Assemblies Installed in Normal Weight Concrete 1,2,3,4 Concrete Compressive Strength Ceiling Wire Type 4000 psi 6000 psi Tension 45-Degree Tension 45 Degree X-CW C27 210 210 X-CW C32 210 210 X-CW U22 100 90 X-CW U27 210 210 130 150 1 The tabulated allowable loads apply to the X-CW ceiling wire assembly using a minimum safety factor of 5.0 in accordance with ICC-ES AC70 if controlled by the powder-actuated fastener pullout or a minimum of 2.0 in accordance with ICC-ES AC368 if controlled by the wire yielding and fracture. 2 Allowable values are for fasteners installed in concrete having the designated compressive strength at the time of installation. 3 Concrete thickness at the point of penetration must be a minimum of the fastener embedment depth plus 1-1/2. 4 Mulitple fasteners must be used for suspended ceiling applications. Approvals ICC-ES (International Code Council) ESR-2892 COLA (City of Los Angeles) Pending Pre-mounted X-U or X-C fastener (X-U Shown) Allowable Loads for Hilti X-CW Ceiling Wire Assemblies Installed in Structural Lightweight Concrete over Composite Floor Deck 1,2,3,4 3000 psi Concrete Compressive Strength Ceiling Wire Type Upper Flute Lower Flute Tension 45-Degree Tension 45 Degree X-CW C27 110 210 100 145 X-CW C32 150 210 100 145 X-CW U27 170 210 150 160 1 The tabulated allowable loads apply to the X-CW ceiling wire assembly using a minimum safety factor of 5.0 in accordance with ICC-ES AC70 if controlled by the powder-actuated fastener pullout or a minimum of 2.0 in accordance with ICC-ES AC368 if controlled by the wire yielding and fracture. 2 Allowable values are for fasteners installed in concrete having the designated compressive strength at the time of installation. 3 Testing completed in composite floor deck having a minimum thickness of 20 gauge (0.0358 ) and a minimum yield strength (Fy) of 38 ksi. Figures 2 4 show nominal flute dimensions, fastener locations and load orientations for the deck profile. Concrete thickness at the point of penetration must be a minimum of the fastener embedment depth plus 1-1/2. 4 Mulitple fasteners must be used for suspended ceiling applications. Pre-mounted Ceiling Wire Hanger Pre-mounted steel clamping washer Hilti, Inc. (US) 1-800-879-8000 www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I X-CW Supplement 2009 1

Direct Fastening Systems Hilti X-CW Ceiling Wire Assembly 1.4 X-CW Installation Instructions 1 Insert X-CW Ceiling Wire Assembly Into the Hilti Powder Actuated Tool 2 Locate the Fastening, Compress the Hilti Powder-Actuated Tool and Install Fastener h nvs 9/32" (7 mm) 3 Check Nail Standoff and Adjust the X-CW Ceiling Wire Position as Needed Figure 1 - X-CW Ceiling Wire Assembly Installation Instructions Hilti, Inc. (US) 1-800-879-8000 www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I X-CW Supplement 2009 2

Direct Fastening Systems Hilti X-CW Ceiling Wire Assembly Figure 2 Hilti X-CW Ceiling Hanger Assembly Location in 3-in.-Deep Composite Floor Deck, Normal Deck Profile Orientation Figure 3 Hilti X-CW Ceiling Wire Assembly Location in 1-1/2-in.-Deep Composite Floor Deck, Normal Deck Profile Orientation Figure 4 Hilti X-CW Ceiling Wire Assembly Location in 1-1/2-in.-Deep Composite Floor Deck, Inverted Deck Profile Orientation Hilti, Inc. (US) 1-800-879-8000 www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I X-CW Supplement 2009 3

Direct Fastening Systems Hilti X-CW Ceiling Wire Assembly X-CW Ceiling Wire Assembly Support Clip for Main Runners Carrying Channel Cross Runners Wall Moulding Acoustical Tile Figure 5 - Indirect Hung Ceiling system (reference ASTM C635) Spline (Spanning Cross Runners) Main Runners X-CW Ceiling Wire Assembly 12 ga. wire typ. 3 tight turns in 1-1/2" Carry Channel or Main Runner typ. Accoustical Lay-in Panels Wall Moulding Cross Runners (Spanning Main Runners) Figure 6 - Direct Hung Ceiling System (reference ASTM C635) Main Runners The X-CW Ceiling Wire Hanger is a state-of-the-art ceiling wire fastening system with an integrated steel wire clamping washer pre-mounted on a Hilti X-U or X-C powder-actuated fastener. This innovative ceiling hanger system has been tested in accordance with the ICC-ES Acceptance Criteria for Fasteners Power-Driven Into Concrete, Steel and Masonry Elements (AC70), January 2007 edition (ESR-2892). The pre-mounted steel clamping washer has been specifically designed to prevent wire slippage, therefore no wire wraps are required on the fastener end. Yielding of the 12 gauge steel hanger wire controls the performance of this ceiling fastening system when installed with pre-mounted X-U and X-C powder-actuated fasteners in 4000 psi normal weight concrete base materials. Requirements for wire wraps on the suspended ceiling component end must still be satisfied. Anchorage of seismic bracing channels and compression struts should be done with ICC-ES AC193 qualified postinstalled anchors, such as Hilti KB-TZ. Hilti, Inc. (US) 1-800-879-8000 www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I X-CW Supplement 2009 4

1.5 Ordering Information X-CW Ceiling Wire Fastening Assemblies Fastener Shank Ø Fastener Length Packaging Description in. (mm) in. (mm) Quantity 1 Standard Fastener X-CW C27 12GA 0.138 (3.5) 1 (27) 1000 X-CW C32 12GA 0.138 (3.5) 1-1/4 (32) 1000 Premium Fastener X-CW U22 12GA 0.157 (4.0) 7/8 (22) 1000 X-CW U27 12GA 0.157 (4.0) 1 (27) 1000 1 Ceiling Wire Assemblies can be assembled with pre-tied wire 4', 6', 8', 10', and 12' lengths Direct Fastening Systems Hilti X-CW Ceiling Wire Assembly Powder-actuated tool DX 351-CT and Accessories Item No. Description 00373103 Powder-actuated tool DX 351-CT a a 00387439 Grip section X-PT CT - 351 b b 00387440 Extension tube X-PT CT-351 3FT c c 00387441 Extension tube X-PT CT-351 1FT d d 00388152 Soft pouch X-PT CT e e 03442190 Powder-actuated tool DX 351-CT Combo Std (Includes Items 1, 2 and 3) 03442191 Powder-actuated tool DX 351-CT Combo Plus (Includes items 1-5) Hilti, Inc. (US) 1-800-879-8000 www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I X-CW Supplement 2009 5

Direct Fastening Systems Notes Hilti, Inc. (US) 1-800-879-8000 www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I X-CW Supplement 2009 6

Hilti. Outperform. Outlast. P.O. Box 21148, Tulsa, OK 74121 Hilti, Inc. (US) 1-800-879-8000 www.us.hilti.com Servicio al Cliente en español 1-800-879-5000 Hilti (Canada) Corporation 1-800-363-4458 www.hilti.ca Hilti is an equal opportunity employer Hilti is a registered trademark of Hilti, Corp. Copyright 2007 by Hilti, Inc. 10/09 BB The data contained in this literature was current as of the date of publication. Updates and changes may be made based on later testing. If verification is needed that the data is still current, please contact the Hilti Technical Support Specialists at 1-800-879-8000. All published load values contained in this literature represent the results of testing by Hilti or test organizations. Local base materials were used. Because of variations in materials, on-site testing is necessary to determine performance at any specific site. Printed in the United States *ISO 14001 US Only