Efficiency enhancement of the ocean thermal energy conversion system with a vapor vapor ejector

Similar documents
Seawater Utilization Plant Research Center, Korea Research Institute of Ships & Ocean Engineering

COMPARATIVE ANALYSES OF TWO IMPROVED CO 2 COMBINED COOLING, HEATING, AND POWER SYSTEMS DRIVEN BY SOLAR ENERGY

Enhancement of CO2 Refrigeration Cycle Using an Ejector: 1D Analysis

Effect of Suction Nozzle Pressure Drop on the Performance of an Ejector-Expansion Transcritical CO 2 Refrigeration Cycle

Available online at ScienceDirect. Giuliano Cammarata, Luigi Cammarata, Giuseppe Petrone*

Scientific Journal Impact Factor: (ISRA), Impact Factor: [Son, 3(10): October, 2014] ISSN:

Application of Viper Energy Recovery Expansion Device in Transcritical Carbon Dioxide Refrigeration Cycle

Second Law Analysis of a Carbon Dioxide Transcritical Power System in Low-grade Heat Source Recovery

Improvement of distillation column efficiency by integration with organic Rankine power generation cycle. Introduction

Performance Analysis of a Combined Power and Ejector Refrigeration Cycle for Different Working Fluids

Performance Evaluation of Solar Assisted Heat Pump Water Heating System

A DUAL LOOP ORGANIC RANKINE CYCLE UTILIZING BOIL-OFF GAS IN LNG TANKS AND EXHAUST OF MARINE ENGINE. * Corresponding Author ABSTRACT 1.

K.S. Rawat 1, H. Khulve 2, A.K. Pratihar 3 1,3 Department of Mechanical Engineering, GBPUAT, Pantnagar , India

The Benefit of Variable-Speed Turbine Operation for Low Temperature Thermal Energy Power Recovery

Energy Conversion and Management

Modeling of Hybrid Solar Pond - Ocean Thermal Energy Conversion for Power Generation

Chapter 8. Vapor Power Systems

Experimental investigation of solar-driven double ejector refrigeration system

CFD ANALYSIS OF STEAM EJECTOR WITH DIFFERENT NOZZLE DIAMETER

ME ENGINEERING THERMODYNAMICS UNIT III QUESTION BANK SVCET

Theoretical investigations on combined power and ejector cooling system powered by low-grade energy source

SEAWATER FLOW RATE REGULATION OF OTEC PLANT USING UEHARA CYCLE BY CONSIDERING WARM SEAWATER TEMPERATURE VARIATION

OTEC power, research and implementation by the Korean Government: Case study of a 1MW power plant for the Republic of Kiribati

Energy Conversion and Management

DESIGN ANALYSIS OF A REFRIGERATED WAREHOUSE USING LNG COLD ENERGY

Exergy Analysis of Absorption Power Cycle Depending on Source Temperatures

Thermodynamic Analysis of Organic Rankine Cycle using Different Working Fluids

Chapter 9: Vapor Power Systems

SIMULATION OF A THERMODYNAMIC CYCLE WITH ORGANIC ABSORBENTS AND CO 2 AS WORKING FLUID

Chapter 5: Thermodynamic Processes and Cycles

ISOBUTANE GEOTHERMAL BINARY CYCLE SENSITIVITY ANALYSIS

ANALYSIS OF REFRIGERATION CYCLE PERFORMANCE WITH AN EJECTOR

Exergy analysis of transcritical carbon dioxide refrigeration cycle with an expander

Available online at ScienceDirect. Procedia Engineering 105 (2015 )

Study on Performance Enhancement of Solar Ejector Cooling System

COMBINED HEAT AND POWER SYSTEMS IN LIQUEFIED NATURAL GAS (LNG) REGASIFICATION PROCESSES

Energy Simulation of a Heat Pump System with Thermal Storage according to Control Strategies

Comparison of micro gas turbine heat recovery systems using ORC and trans-critical CO 2 cycle focusing on off-design performance

Parametric Study of a Vapor Compression Refrigeration Cycle Using a Two-Phase Constant Area Ejector

Evaluation and optimization of organic Rankine cycle (ORC) with algorithms NSGA-II, MOPSO, and MOEA for eight coolant fluids

CHARACTERISTICS OF PRESSURE RECOVERY IN TWO-PHASE EJECTOR APPLIED TO CARBON DIOXIDE HEAT PUMP CYCLE

AREN 2110: Thermodynamics Spring 2010 Homework 7: Due Friday, March 12, 6 PM

Chapters 5, 6, and 7. Use T 0 = 20 C and p 0 = 100 kpa and constant specific heats unless otherwise noted. Note also that 1 bar = 100 kpa.

Parametric Study of a Double Effect Absorption Refrigeration System

MODELING THERMODYNAMIC ANALYSIS AND SIMULATION OF ORGANIC RANKINE CYCLE USING GEOTHERMAL ENERGY AS HEAT SOURCE

Energy and Buildings

Study on Ejector - Vapor Compression Hybrid Air Conditioning System Using Solar Energy

A discussion of"heat pumps as a source of heat energy for desalination of seawater"

Efficiency of Compact Organic Rankine Cycle System with Rotary-Vane-Type Expander for Low-Temperature Waste Heat Recovery

THERMODYNAMIC ANALYSIS OF ORGANIC RANKINE CYCLE USING LNG COLD ENERGY DEPENDING ON SOURCE TEMPERATURES

Compound ejectors with improved off-design performance

High-Efficiency Joule-Thomson Cryocoolers Incorporating an Ejector

Study of Performance Improvement of Air Conditioning using Various Heat Recovery Techniques

UNIVERSITY OF TORONTO FACULTY OF APPLIED SCIENCE AND ENGINEERING FINAL EXAMINATION, DECEMBER 2008 MIE 411H1 F - THERMAL ENERGY CONVERSION

Analysis of the Thermal Exploitation of the Vinasse from Sugarcane Ethanol Production through Different Configurations of an Organic Rankine Cycle

Code No: RR Set No. 1

- 2 - SME Q1. (a) Briefly explain how the following methods used in a gas-turbine power plant increase the thermal efficiency:

Optimal Design and Thermodynamic Analysis of Gas Turbine and Carbon Dioxide Combined Cycles

Comparison of combined heat and power systems using an organic Rankine cycle and a low-temperature heat source

BINARY BLEND OF CARBON DIOXIDE AND FLUORO ETHANE AS WORKING FLUID IN TRANSCRITICAL HEAT PUMP SYSTEMS

Thermodynamic performance of Kalina cycle system 11 (KCS11): feasibility of using alternative zeotropic mixtures

Comparative assessment of refrigerants and non refrigerants as working fluids for a low temperature Organic Rankine Cycle

Superior Efficiency Reduced Costs Viable Alternative Energy Kalex Kalina Cycle Power Systems For Ocean Thermal Energy Conversion Applications

Thermodynamic Analysis of Combined Power and Cooling Cycle Using Process Heat from a Passout Turbine as a Heating Source

R13 SET - 1 '' ''' '' ' '''' Code No: RT31035

PERFORMANCE STUDY OF SOLAR THERMAL BINARY POWER CYCLES

COEFFICIENT OF PERFORMANCE OF TWO PHASE CONDENSING EJECTOR REFRIGERATION SYSTEM WITH R-22

Available online at ScienceDirect. Energy Procedia 110 (2017 )

Numerical Investigation of the Flow Dynamics of a Supersonic Fluid Ejector

Investigation of Separator Parameters in Kalina Cycle Systems

Performance study on solar assisted heat pump water heater using CO 2 in a transcritical cycle

A Design of the Organic Rankine Cycle for the Low Temperature Waste Heat

PERFORMANCE ANALYSIS OF ORGANIC RANKINE CYCLES USING DIFFERENT WORKING FLUIDS

Advanced energy saving in the evaporation system of ammonium sulfate solution with self-heat recuperation technology

Energy analysis of underwater energy storage system based on compressed air

Heat Pump Efficiencies simulated in Aspen HYSYS and Aspen Plus

Energy analysis and performance evaluation of a novel multi-evaporator ejector refrigeration cycle (ERC)

GAS COOLING HEAT TRANSFER AND PRESSURE DROP CHARATERICTICS OF CO 2 /OIL MIXTURE IN A MICROCHANNEL ABSTRACT

Supersonic Nozzle Flow in the Two-Phase Ejector as Water Refrigeration System by Using Waste Heat

A review on Present development in refrigeration jet ejector system

Roberto Bini Turboden srl Brescia I Fabio Viscuso Turboden srl Brescia -I. cod. 11-A-858-rev.0

Development of an ejector cooling system with thermal pumping effect

Superior Efficiency Reduced Costs Viable Alternative Energy Kalex Kalina Cycle Power Systems For Cement Kiln Waste Heat Applications

Lecture No.3. The Ideal Reheat Rankine Cycle

1. To improve heat exchange between a gas & a liquid stream in a heat exchanger, it is decided to use fins. Correct the suitable option.

Thermodynamic Analysis of Double-Stage Compression Transcritical CO 2 Refrigeration Cycles with an Expander

ScienceDirect. Simulation of a novel single-column cryogenic air separation process using LNG cold energy

CO 2 Transcritical Cycle for Ground Source Heat Pump

Evaluation of an Organic Rankine Cycle Using a Non-Imaging Solar Concentrator for Different Working Fluids

Analysis of zeotropic mixtures used in low-temperature solar Rankine cycles for power generation

Problems in chapter 9 CB Thermodynamics

CHAPTER 1 BASIC CONCEPTS

Reg. No. : Question Paper Code : B.E./B.Tech. DEGREE EXAMINATION, NOVEMBER/DECEMBER Second Semester

Renewable Energy 51 (2013) 234e240. Contents lists available at SciVerse ScienceDirect. Renewable Energy

Investigations Of Low Pressure Two-Phase Steam- Water Injector

Thermodynamics: An Engineering Approach, 6 th Edition Yunus A. Cengel, Michael A. Boles McGraw-Hill, 2008

Exergy analysis of internal regeneration in supercritical cycles of ORC power plant

Problems 2-9 are worth 2 points each. Circle T or F as appropriate for problems 6-9.

II. SYSTEM DESCRIPTION AND MATHEMATICAL MODELING

Thermodynamic Analysis of Geothermal Power Generation Combined Flash System with Binary Cycle

Transcription:

Special Issue Article Efficiency enhancement of the ocean thermal energy conversion system with a vapor vapor ejector Advances in Mechanical Engineering 1 10 Ó The Author(s) 2015 DOI: 10.1177/1687814015571036 aime.sagepub.com Ho-Saeng Lee 1, Jung-In Yoon 2, Chang-Hyo Son 2, Soo-Jung Ha 2, Sung-Hoon Seol 2, Byung Hyo Ye 2, Hyeon-Ju Kim 1 and Gun-Joo Jung 3 Abstract In this article, 20 kw ocean thermal energy conversion with a vapor vapor ejector is newly proposed. As a vapor vapor ejector is installed in the system, the pressure difference between the turbine inlet and outlet increases. Therefore, the amount of the working fluid required for the total turbine work of 20 kw is less than when no vapor vapor ejector is installed. Therefore, installing a vapor vapor ejector in the system decreases the evaporation capacity and the pump work. The performance analysis considered the outlet pressure of the high-stage turbine, the mass flow ratio of the working fluid at the outlet of a separator just after the high-stage turbine, and the nozzle diameters of the vapor vapor ejector. As the outlet pressure of high-stage turbine becomes lower, the turbine gross power of high-stage turbine and system efficiency increase although lower outlet pressure of high-stage turbine results in lower ejector performance. Similarly, in terms of mass flow ratio, the highest system efficiency was shown at mass flow ratio of 0.4 at the outlet of a separator just after the high-stage turbine. On the other hand, the performance of the ejector at mass flow ratio of 0.5 at the outlet of a separator was largest. When the nozzle diameters of the vapor vapor ejector are properly designed, the vapor vapor ejector shows the highest performance. After the optimization of the operation parameters, system efficiency of the proposed ocean thermal energy conversion power cycle was 2.47%, relatively 15% higher than that of the basic ocean thermal energy conversion power cycle (2.2%). Keywords Ocean thermal energy conversion, vapor vapor ejector, performance analysis Date received: 4 November 2014; accepted: 31 December 2014 Academic Editor: Haitao Yu Introduction With the steady rise in the usage of fossil energy, ocean thermal energy conversion (OTEC), a renewable-energy system, is increasingly being regarded as the solution to global warming and environmental pollution. The OTEC power cycle is a system that produces electricity from the generator of a turbine with a temperature difference of 21 C 24 C between the surface seawater (the upper temperature level) and the deep seawater (the lower temperature level). Since the temperature and pressure difference between high level and low level 1 Seawater Utilization Plant Research Center, Korea Research Institute of Ships & Ocean Engineering, 124-32 Simcheungsu-gil, Jukwang-myeon, Goseong-gun, Gangwon-do, South Korea 2 Department of Refrigeration and Air Conditioning Engineering, College of Engineering, Pukyong National University, San 100, Yongdang-dong, Nam-gu, Busan, South Korea 3 Department of Architectural Engineering, College of Engineering, Pukyong National University, San 100, Yongdang-dong, Nam-gu, Busan, South Korea Corresponding author: Soo-Jung Ha, Department of Refrigeration and Air Conditioning Engineering, College of Engineering, Pukyong National University, San 100, Yongdang-dong, Nam-gu, Busan 608-739, South Korea. Email: soojung60@gmail.com Creative Commons CC-BY: This article is distributed under the terms of the Creative Commons Attribution 3.0 License (http://www.creativecommons.org/licenses/by/3.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (http://www.uk.sagepub.com/aboutus/ openaccess.htm).

2 Advances in Mechanical Engineering is too small, the system efficiency of the OTEC power cycle is relatively lower (about 2%) than those of other kinds of renewable-energy systems such as waterpower generation (about 80% 90%) and solar heat generation (about 10% 15%). Thus, various researches with the aim of improving its system efficiency are underway worldwide. The previous researches for improving the system efficiency of the OTEC power cycle are discussed below. Soto and Vergara 1 researched on the work conditions and system size depending on the efficiency of the system adopting waste heat from power plants and reported that the turbine gross power of the system increases by 1.3% when the system utilizes the waste heat from power plants. Yamada et al. 2 reported that the system efficiency of the OTEC power cycle can be increased 1.5-fold if the temperature of the surface seawater flowing into an evaporator with a solar collector will be increased or by providing more superheat to a working fluid that evaporates in an evaporator. Yoon et al. 3 5 suggested a high-efficiency OTEC power system using a regenerator and a cooler and conducted a performance analysis to confirm the system s high efficiency. By placing a regenerator at the evaporator inlet, the evaporation capacity was decreased, increasing the system efficiency. A performance analysis of subcritical OTEC power cycle with various working fluids was conducted. Additionally, an ejector was placed at the condenser inlet, and an initial research about the optimization process was done by adjusting the mass flow ratio of a working fluid at the outlet of a separator just after the high-stage turbine and the diameters of the ejector. Zhang et al. 6 explained different Kalina systems and their different applications. Kalina cycle has been diversified by applying different components or using different heat sources. Low- or high-temperature geothermal energy, heat from industrial wastewater, coal, and other solid fuels are those of good examples. Additionally, to confirm the efficiency of this cycle, energy analysis was conducted, the revised cycle was compared with the basic Kalina cycle, and the cycle was explained. Li et al. 7,8 set an ejector at the condenser inlet of the Kalina cycle and researched on the effect of the ejector on the system efficiency. Turbine gross power increased compared with the basic OTEC power cycle. The change in the turbine gross power based on the placement of an ejector between the turbine outlet and the condenser inlet of the supercritical organic Rankine cycle (ORC) was reviewed. The turbine gross power was highest at the supercritical ORC with an ejector. Huang and Chang 9 came up with an ORC system with an ejector and provided basic data for the performance of the ejector and for the interrelation between the nozzle area ratio of the ejector and the mass flow ratio flowing into the ejector. In the previous studies mentioned above, an ejector was applied to improve the system efficiency of the OTEC power cycle. In this study, to improve the system efficiency of the OTEC power cycle, a vapor vapor ejector was installed at the condenser inlet of the system. In addition, performance analysis was conducted for the optimization of this power system, and the factors in the optimization are as follows. First, the outlet pressure of the high-stage turbine was adjusted, and then the mass flow ratio at separator 1 (states 4 and 6) and the diameters of the vapor vapor ejector nozzle were controlled to determine the optimal performance conditions and output. OTEC power cycle and theoretical concept of the vapor vapor ejector Basic OTEC cycle Figure 1 shows schematics of the basic OTEC cycle. Basic OTEC cycle has four main components, consisting of an evaporator, a turbine, a condenser, and a refrigerant pump. The liquid refrigerant in the evaporator is heated and vaporized by surface seawater at 26 C. This vapor refrigerant flows into the turbine where its enthalpy is converted into power, and then vapor refrigerant in the condenser is cooled and condensed by releasing heat to deep seawater at 5 C. The pump is used to circulate and pressurize the refrigerant in the OTEC power cycle continuously. The highpressure liquid refrigerant flows into the evaporator to complete the cycle. So, as long as temperature difference between the surface and deep seawater is large Figure 1. Schematics of the basic OTEC.

Yoon et al. 3 Figure 2. Schematics of the OTEC power cycle using a vapor vapor ejector. enough, the cycle will continue to operate and generate power. Proposed OTEC cycle applying a vapor vapor ejector Figure 2 shows the schematic of the high-efficiency OTEC power cycle with a vapor vapor ejector. As regards the flow of the working fluid of the OTEC power cycle with a vapor vapor ejector, first, the working fluid that passed the evaporator flows into the high-stage turbine with the states of high temperature and high pressure, and then expands into the liquid vapor state. To separate the expanded liquid and vapor, separator 1 was installed at the outlet of the high-stage turbine. The liquid separated from separator 1 flows into pump 1 and is then pressurized up to the evaporation pressure. The vapor is then divided into two: that which flows into the low-stage turbine and that which goes to the motive part of the vapor vapor ejector. The high-temperature vapor that passed through the low-stage turbine flows into separator 2 after becoming low-temperature liquid vapor. At this point, the liquid from the separator is pressurized up to the evaporation pressure as it flows into pump 2; meanwhile, the vapor flows into the suction part of the vapor vapor ejector. The vapor from a suction nozzle is compressed, and the one from a motive nozzle is expanded inside the ejector and is then spurted at the discharge part of the ejector. Thereafter, this vapor is condensed at the condenser and then flows into pump 3. Each liquid, which is pressurized by pumps 1 3 up to the evaporation pressure, is mixed at the inlet of the evaporator. Pressure, P [kpa] P E P C 13 12 1 2 14 9 5 Enthalpy, h [kj/h] Figure 3 shows the stage points of the OTEC power cycle with a vapor vapor ejector on a P h diagram. In Figure 3, condensation pressure is defined as state points 10 and 11; by utilizing a vapor vapor ejector, the outlet pressure of the low-stage turbine is decompressed up to state point 7, which is lower than the condensation pressure. Thus, the gross power of the low-stage turbine increases with the application of a vapor vapor ejector when fixed amount of working fluid circulates. When the system is set to produce 20 kw, the required amount of working fluid is reduced by increased pressure difference of turbine inlet and outlet. Therefore, installing a vapor vapor ejector decreases evaporation capacity, condensation capacity, pump work, and system size. 3 4,6 11 10 7 8 Figure 3. P h diagram of the proposed OTEC power cycle using a vapor vapor ejector.

4 Advances in Mechanical Engineering Suc on chamber Constant-area sec on Diffuser Nozzle Mo ve Flow (State 4) D m Discharge Flow (State 12) D d D s Throat Suc on Flow (State 8) Figure 4. Schematic diagram of the vapor vapor ejector. In short, the OTEC power cycle proposed in this article is summarized as a cycle that increases the turbine gross power by adopting multi-stage turbines, multi-stage pumps, and a vapor vapor ejector. Theoretical concept of the vapor vapor ejector The internal structure of the vapor vapor ejector proposed in this article is shown in Figure 4. This ejector mainly consists of a motive part, a suction part, and a discharge part. The working fluid from state 4 in Figure 1 is fed to the motive part and passes through the nozzle. At this point, following Bernoulli s theorem, the velocity of the motive working fluid increases, and its pressure decreases. Here, the working fluid from state 8 in Figure 2, which is the suction flow, is inhaled by the motive working fluid and then flows inside. The inhaled suction working fluid is mixed with the motive working fluid that passed through the nozzle, as shown in the constant-area section of Figure 4. The mixed working fluid is emitted through the discharge part. Performance analysis of the OTEC power cycle with a vapor vapor ejector was done using Aspentech HYSYS. 10 The correlation deciding the discharge pressure of the ejector is shown below P d = (M d V d 0:01h e M s V s M m V m ) A d 3600 1000 +P s ð1þ According to equation (1), the pressure of the discharge part is determined by the diameters of the nozzles of the discharge part and by the mass flow and velocity of the suction, discharge, and motive parts. Thus, the proper mass flow ratio of the motive flow and suction flow (states 4 and 6), velocity in the ejector, and diameter ratio of motive part, suction part, and discharge part are very important factors deciding the performance of the vapor vapor ejector. State equation and simulation method State equation A state equation is required to analyze the performance of OTEC power cycle applying a vapor vapor ejector using HYSYS. Peng Robinson equation of equation (2) that involves interrelation of components is used to calculate phase balance of compounds. 11 In addition, the formula yielding the system efficiency is shown as equation (6) P= R T v b a a v(v + b) + b(v b) a=0:45724 R2 T 2 C P C b=0:07780 R T C P C ð2þ ð3þ ð4þ a = 1 +(0:37464 + 1:54226v 0:26992v 2 )(1 T 0:5 rd ) 2 ð5þ h = W t W p Q E ð6þ Q E =h 2 h 1 ð7þ W t =W HT +W LT = ðh 2 h 3 Þ+ ðh 7 h 6 Þ ð8þ W p =W p1 +W p2 +W p3 = ðh 14 h 5 Þ + ðh 13 h 9 Þ+ ðh 12 h 11 Þ Simulation method ð9þ The simulation conditions are shown in Table 1. Regarding the working conditions, the inlet and outlet temperatures of each surface seawater and deep seawater are the most important factor in this study, and these are considered not to be changed since these are

Yoon et al. 5 Table 1. Simulation conditions of the basic and proposed OTEC power cycle using the vapor vapor ejector. Variable Proposed OTEC cycle Basic OTEC cycle Working fluid R32 R32 Gross power of turbine (kw) 20 20 Temperature of deep seawater at condenser inlet ( C) 5 20 Temperature difference of deep seawater inlet and outlet ( C) 5.8 5.8 Temperature of surface seawater at evaporator inlet ( C) 26 26 Temperature difference of surface seawater inlet and outlet ( C) 3 3 Inlet pressure of evaporator (kpa) 1536 1536 Inlet pressure of condenser (kpa) 1196 1196 Efficiency of turbine (%) 80 80 Efficiency of working fluid pump (%) 65 65 LMTD of evaporator and condenser ( C) 3.5 3.5 Pressure drop in heat exchanger(working fluids/water) (kpa) 10/50 Initial diameter of ejector (motive/suction/discharge) (mm) 50/50/50 Initial mass flow ratio at outlet of separator 1 0.5/0.5 OTEC: ocean thermal energy conversion; LMTD: logarithmic mean temperature difference. fixed values by the surroundings. The evaporator inlet pressure of the cycle, which is suitable for the conditions shown in Table 1, is 1536 kpa, and its condenser inlet pressure is 1196 kpa. The outlet pressure of the high-stage turbine was adjusted between these two values. Similarly, the pump power was also decided by evaporator inlet pressure and condenser inlet pressure. After setting the conditions in Table 1, the following variables were changed: outlet pressure of high-stage turbine (state 3) from 1200 to 1500 kpa, mass flow ratio at separator 1 outlet (state 4) from 0.2 to 0.8, and the diameters of the motive nozzle, suction nozzle, and discharge nozzle. The mass flow at the outlet of separator 1 is divided into two parts: the part that flows into the motive part of the vapor vapor ejector (states 4) and the part that goes to the low-stage turbine (states 6). The simulation conditions and the method of basic OTEC cycle are the same as the proposed OTEC cycle, shown in Table 1. Results and discussion Outlet pressure of the high-stage turbine The heat flow transferring from the heat source to working fluid in the evaporator, pump power, system efficiency, and ejector performance was analyzed by adjusting the outlet pressure of the high-stage turbine. Figure 5 presents the system efficiency, pump work, and evaporation capacity depending on the outlet pressure of the high-stage turbine. The system efficiency showed the highest value when the pressure was 1200 kpa. On the other hand, the evaporation capacity and pump work were not changed by the outlet pressure. Thus, the most proper outlet pressure of the highstage turbine is 1200 kpa. Figure 6 shows the effect of the outlet pressure on the internal pressure and performance of the ejector. Pressure recovery defined as equation (10) is used to show the performance of the ejector DP=P d P s ð10þ DP in equation (10) is the result of the subtraction of the suction pressure from the discharge pressure of the ejector. The bigger the pressure difference between them, the bigger the pressure recovery that occurs from the vapor vapor ejector, which signifies the excellent performance of the ejector. As can be seen in Figure 6, the optimized outlet pressure of the high-stage turbine is 1500 kpa. In other words, when the pressure of the high-stage turbine is 1200 kpa, the performance of the vapor vapor ejector shows the lowest performance, and at the pressure of 1500 kpa, it presents the highest value. Thus, from the aforementioned results shown in Figures 5 and 6, the optimized outlet pressure of the high-stage turbine in the aspect of system efficiency, and that in the aspect of the performance of the vapor vapor ejector, is different. However, system efficiency is the most important result in this study, while the ejector is only a part of the total system although it still takes an important role of improving system efficiency. Even if the performance of the ejector is low, the outlet pressure of high-stage turbine with the highest system efficiency should be selected. Therefore, the optimized high-stage turbine outlet pressure is 1200 kpa. Mass flow ratio at the outlet of separator 1 (states 4 and 6) As shown in Figure 1, the working fluid that passed through the low-stage turbine flows into the suction

6 Advances in Mechanical Engineering 2.4 2.4 1090 System efficiency, η [%] 2.2 2.0 1.8 1.6 1.4 1.2 Evaporation capacity Pump work System efficiency 2.2 2.0 1.8 1.6 1.4 1.2 Total pump work, W P 1080 1070 1060 Evaporation capacity, Q E 1.0 1.0 1150 1200 1250 1300 1350 1400 1450 1500 1550 1050 Outlet pressure of high stage turbine, P HT [kpa] Figure 5. Evaporation capacity, pump work, and system efficiency with respect to the outlet pressure of the high-stage turbine. Pressure, P [kpa] 1220 18 1200 Discharge part Suction part 17 1180 1160 16 1140 15 1120 Pressure recovery 14 1100 1080 13 1060 12 1150 1200 1250 1300 1350 1400 1450 1500 1550 Outlet pressure of high stage turbine, P 3 [kpa] Pressure recovery in ejector, P [kpa] Figure 6. Pressure recovery with respect to the outlet pressure of the high-stage turbine. part of the vapor vapor ejector. As it undergoes expansion in the low-stage turbine, liquid is partly formed. The amount of this liquid, however, is less than about 2%. Therefore, much of the working fluid flows into the suction part of the ejector as vapor. Figure 7 presents the evaporation capacity, total pump work, and system efficiency depending on the mass flow ratio at the outlet of separator 1 (states 4 and 6), and the system efficiency is highest when the mass flow ratio at state 4 is 0.4. Figure 8 shows the results of the performance analysis of the ejector depending on the mass flow ratio. From equation (10), when the mass flow ratio of state 4 was 0.5, pressure recovery was the highest and performance of the ejector was the best. In short, the system efficiency was the highest when the mass flow ratio of state 4 (i.e. the inlet of the low-stage turbine) is 0.4. Additionally, in terms of the performance of the ejector, the pressure recovery was highest when the ratio was 0.5. There was a difference between the optimized ratio for the highest efficiency and that for the performance of the ejector. Similar to the case described in section Outlet pressure of the high-stage turbine, system efficiency is the most important result in the cycle.

Yoon et al. 7 System efficiency, η [%] 2.3 2.2 2.1 2.0 Evaporation capacity System efficiency Pump work 2.4 2.2 2.0 1.8 1.6 1.4 1.2 Total pump work, T P 1090 1080 1070 1060 Evaporation capacity,q E 1.9 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1.0 1050 Mass flow ratio of State 4 [-] Figure 7. Evaporation capacity, pump work, and system efficiency with respect to the mass flow ratio of state 4 at the outlet of separator 1. Pressure, P [kpa] 1240 1220 1200 1180 1160 1140 Pressure recovery Discharge part Suction part 0.2 0.3 0.4 0.5 0.6 0.7 0.8 20 15 10 5 0 Pressure recovery in ejector, P [kpa] Mass flow ratio of State 4 [-] Figure 8. Pressure drop with respect to the mass flow ratio of state 4 at the outlet of separator 1. Although the performance of the ejector is low, the mass flow ratio with the highest efficiency should be selected for the optimization. Diameters of the vapor vapor ejector nozzle The effect of diameters of the vapor vapor ejector nozzles on the performance of the cycle was analyzed. Table 2 shows the diameters of the nozzles of the vapor vapor ejector. Five diameter size cases are proposed with respect to the mass flow ratio at the outlet of separator 1, and all the diameters of the vapor vapor ejector are reduced by 10 mm from cases 1 to 5. Table 2. Proposed diameters of the ejector. Case 1 65/75/70 2 55/65/60 3 45/55/50 4 35/45/40 5 25/35/30 Motive/suction/discharge diameters in ejector (mm) Figure 9 shows the evaporation capacity, pump work, and system efficiency depending on the diameters of the vapor vapor ejector. As the diameters of the

8 Advances in Mechanical Engineering System efficiency, η [%] 2.9 2.8 2.7 2.6 2.5 2.4 2.3 2.2 Evaporation capacity Pump work System efficiency 1.5 1.4 1.3 1.2 1.1 Total pump work, W P 850 800 750 700 650 Evaporation capacity, Q E 2.1 Case 1 Case 2 Case 3 Case 4 Case 5 1.0 600 Cases of table 2 [-] Figure 9. Evaporation capacity, pump work, and system efficiency with respect to the nozzle diameters of the ejector. Pressure, P [kpa] 1250 1200 1150 1100 1050 1000 Discharge part Suction part Pressure recovery Case 1 Case 2 Case 3 Case 4 Case 5 140 120 100 80 60 40 20 0 Pressure recovery in ejector, P [kpa] Cases in Table 2 [-] Figure 10. Pressure recovery of the ejector with respect to the nozzle diameters of the ejector. nozzles were decreased from cases 1 to 5, the system efficiency drastically increased, and the pump power and evaporation capacity decreased. As all the diameters of the ejector are reduced, the performance of the ejector is improved. Therefore, the required amount of the working fluid to produce set turbine gross power is decreased. As a result of it, evaporation capacity and pump work are decreased, and it causes an increase in the system efficiency together with the improved performance of the ejector. Figure 10 shows the performance of the vapor vapor ejector. The pressure recovery increased from cases 1 to 5 of the designed nozzle diameters. In this cycle, discharge pressure is fixed to condensation pressure, decided by the temperature of deep seawater. Following equation (1), P s decreases as V s and V m decrease. Here, the velocity of the flow is the subordinated factor of diameter of the nozzle. Therefore, the results show that suction pressure decreases as the nozzle diameter decreases. Figure 11 shows the flow velocity of the motive, suction, and discharge part depending on the diameters of the nozzle of each part. The desirable velocity range of the mass flow, which goes into the vapor vapor ejector, was set at 30 60 m/s considering the shockwave that might occur due to the supersonic vapor. The results

Yoon et al. 9 Flow velocity, V [m/s] 100 80 60 40 20 0 with respect to the diameters of the nozzles, according to Table 2, are as follows. In case 4, when the nozzle diameters of the motive, suction, and discharge part were 35, 45, and 40 mm, respectively, the flow velocity at these three parts was within the suitable range of 30 60 m/s. In conclusion, the system efficiency increases and the performance of the ejector is improved by reducing the diameters of each nozzle. The optimized diameters of the nozzle, however, in the aspects of system efficiency and suitable flow velocity are 35, 45, and 40 mm for motive part, suction part, and discharge part, respectively. Optimization result of proposed OTEC cycle with a vapor vapor ejector From the process described in sections Outlet pressure of the high-stage turbine, Mass flow ratio at the outlet of separator 1 (states 4 and 6), and Diameters of the vapor vapor ejector nozzle, the optimized working conditions were decided as shown in Table 3. The system efficiency of the OTEC power cycle with a vapor vapor ejector can be improved compared to the basic OTEC power cycle by optimizing the outlet pressure of high-stage turbine, the diameters of the vapor vapor ejector nozzles, and the mass flow ratio at the outlet of separator 1 (states 4 and 6). Especially, varying the diameters of the nozzles causes the largest enhancement of the system efficiency compared to controlling the other factors proposed by this study. Conclusion Motive nozzle Suction nozzle Discharge nozzle Permissible Flow Velocity [m/s] Case 1 Case 2 Case 3 Case 4 Case 5 Cases of table 2 [-] Figure 11. Optimized nozzle diameters of the ejector with respect to the permissible flow velocity. This study evaluated an idea of dividing mass flow at a separator outlet and adding a vapor vapor ejector at Table 3. Optimized conditions of the proposed OTEC power cycle using the vapor vapor ejector. Parameters the condenser inlet to improve system efficiency of an OTEC power cycle. The process flow of the proposed system was analyzed to optimize system efficiency. The optimized condition is shown in Table 3. The system efficiency of the proposed system was determined to be 2.47%, which is relatively 15% higher than that of the basic OTEC power cycle (2.2%). By using the vapor vapor ejector, it can be seen that the low-stage turbine gross power will be decreased because the amount of the working fluid flowing into the low-stage turbine is reduced. Considering the performance of the vapor vapor ejector, however, the ejector drops the pressure at the outlet of the low-stage turbine to a point lower than the condensation pressure. This results in an increase in the gross power of the low-stage turbine and the system efficiency. Declaration of conflicting interests The authors declare that there is no conflict of interest. Funding Value Pressure at state 1 (kpa) 1536 Pressure at state 2 (kpa) 1526 Pressure at states 3, 4, and 6 (kpa) 1200 Pressure at states 7 and 8 (kpa) 1139 Pressure at state 10 (kpa) 1196 Pressure at state 11 (kpa) 1186 Temperature at state 1 ( C) 12.29 Temperature at state 2 ( C) 24 Temperature at states 3, 4, and 6 ( C) 12.37 Temperature at state 7 and 8 ( C) 10.59 Temperature at state 10 ( C) 12.24 Temperature at state 11 ( C) 11.96 Motive pressure (kpa) 1.200.00 Suction pressure (kpa) 1138.50 Discharge pressure (kpa) 1195.60 Mass flow ratio (motive/suction) 0.4/0.6 Pressure recovery of the suction 57.18 flow in the ejector (kpa) Ejector nozzle diameter 35/45/40 (motive/suction/discharge) (mm) Mass flow rate (kg/h) 8740 Evaporator capacity (kw) 757.50 Condensation capacity (kw) 738.80 System efficiency (%) 2.47 This work was financially supported by the R&D project of Development of Desalination Plant using Ocean Thermal Energy supported by the Korea Research Institute of Ships & Ocean Engineering.

10 Advances in Mechanical Engineering References 1. Soto R and Vergara J. Thermal power plant efficiency enhancement with Ocean Thermal Energy Conversion. Appl Therm Eng 2014; 62(1): 105 112. 2. Yamada N, Hoshi A and Ikegami Y. Performance simulation of solar-boosted ocean thermal energy conversion plant. Renew Energ 2009; 34(7): 1752 1758. 3. Yoon JI, Son CH, Baek SM, et al. Performance characteristics of a high-efficiency R717 OTEC power cycle. Appl Therm Eng 2014; 72(2): 304 308. 4. Yoon JI, Son CH, Baek SM, et al. Efficiency comparison of subcritical OTEC power cycle using various working fluids. Heat Mass Tran 2014; 50(7): 985 996. 5. Yoon JI, Son CH, Kim HU, et al. Performance characteristic of the CO2 OTEC power cycle applying the ejector. Korea Soc Marine Environ Energy 2013: 285. 6. Zhang X, He M and Zhang Y. A review of research on the Kalina cycle. Renew Sust Energ Rev 2012; 16(7): 5309 5318. 7. Li X, Zhang Q and Li X. A Kalina cycle with ejector. Energy 2013; 54: 212 219. 8. Li X, Huang H and Zhao W. A supercritical or transcritical Rankine cycle with ejector using low-grade heat. Energ Convers Manag 2014; 78: 551 558. 9. Huang BJ and Chang JM. Empirical correlation for ejector design. Int J Refrig 1999; 22(5): 379 388. 10. Aspen HYSYS. Version 8.0, Aspen Technology Inc. 11. Peng DY and Robinson DB. A new TWO-constant equation of state. Ind Eng Chem Fund 1976; 15(1): 59 64. Appendix 1 Notation a attraction parameter ( ) A area (m 2 ) b repulsion parameter ( ) D diameter (mm) h enthalpy (kj/kg) M mass flow (kg/h) P pressure (kpa) Q heat flow (kw) R universal gas constant ( ) T absolute temperature (K) v volume (m 3 ) V flow velocity (m/s) W power, work (kw) a parameter of equation (5) ( ) DP pressure recovery (kpa) h efficiency (%) v acentric factor of the species ( ) Subscripts 1 14 stage points in the cycle c critical point C condenser d discharge part of a vapor vapor ejector e ejector E evaporator HT high-stage turbine LT low-stage turbine m motive part of a vapor vapor ejector p pump r ratio rd reduced properties s suction part of a vapor vapor ejector t turbine