Hydraulic Fluid Contamination and Assessment. Fluid Power Engineering Technology Instructor Hennepin Technical College

Similar documents
Piedmont Chapter 14, Vibration Institute Meeting December 5, Midlands Technical College West Columbia, SC

How equipment reliability delivers low cost, energy efficient assets at plants around the world!

Introduction. Adverse Affects

#287 FOOD GRADE FLUSHING AGENT

WATER & PARTICULATE CONTAMINATION IN OIL & LUBRICATED SYSTEMS

FLUID CLEANLINESS OIL FILTRATION

Company Standard THIS DOCUMENT IS INTENDED TO BE USED BY BOTH EXTERNAL SUPPLIERS AND NIFTYLIFT INTERNAL QUALITY DEPARTMENT.

Filtration of Industrial Lubes:

New filter materials for hydraulic systems: Longer service life and reduced operating costs

E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min

DFE... The Evolution in Filter Element Multi-Pass Development Testing Hy-Pro s Competitive Advantage

Contamination Control in the Hydraulic Industry

Contamination Fundamentals

DFE. Dynamic Filter Efficiency. hyprofiltration.com/dfe

OFFLINE FILTRATION SERVICE

The World s Most Versatile Filter System

Rexroth Oil Cleanliness Booklet

Clean Oil. Guide. 100 micrometres Grain of salt. 40 micrometres Naked eye visibility. 70 micrometres Human hair. 3 micrometres OIL

EPK- EasyTest Patch Test Kit Manual

Fluid Contamination Under Control...

E 444 E 454 E 464 E 644 Tank top mounting Connection up to SAE 2 Nominal flow rate up to 680 l/min / gpm

D 090 D 100 In-line mounting Connection up to G¾ Nominal flow rate up to 110 l/min

Product Data Castrol Anvol WG46

LUBRICANTS IN TEXTILE MILLS By A.M. Nagar

BEST PRACTICES FOR AN EFFECTIVE OIL ANALYSIS PROGRAM

The Packaging Industry

How to take a Sample. General instructions for correct oil sampling. Ensuring Health and Safety conditions. Ensuring the quality of the sample.

Lesson. Using Hydraulic Systems

Technical White Paper

Filtration Guideline. Introduction. STAUFF Filtration Technology offers two publications with knowledge and expertise about

CJC Fine Filter Technology

Return Filters D 090 D 100. In-line mounting Connection up to G¾ Nominal flow rate up to 110 l/min e

Par-Test. Fluid Analysis

Multi-Bag Filters. Housing Options. MODEL NO. Diameter (inches) = Model No. BASKET TYPE PB = Filter bag basket. BASKET DEPTH 30 inch (std.

Lubricant management for non-circulating sumps

Donaldson Delivers Portable Fluid Analysis Kit

Filtration Products. Fluid purifier systems and oil service equipment

How to ensure proper oil cleanliness in lubrication systems

Universal Bottle Sampler

Simple Solutions for Removing Moisture, even with Strong Emulsions, from Oils up to ISO VG 1000

Fluid Analysis. What Can Fluid Analysis Do For You? Suggested Sampling Intervals and Methods

Assessment Schedule - TS.5

How to Obtain Total Purity in Hydraulicand Lube Oil Systems?

The Basics of Used Oil Sampling

R.O water vending machine (USER MANUAL)

E 443 E 453 E 463 E 643. Tank top mounting Connection up to SAE 2 Nominal flow rate up to 550 l/min e

Water Absorbing Filter Elements

THE FRENCH KNOW-HOW IN HYDRAULICS

Oil Contamination. The origins, treatment and analysis of contaminated oil in hydraulic systems.

Test and service hydraulic systems on equipment, vehicles, and/or machines

Instruction manual AS 300 CG. Waste water filtration unit. Im Geer 20, D Isselburg. Descriptioin / Type-No.: AS 300 CG Typ 539

SDD: Total Productive Maintenance Rev 1: 2013 November 10. Page 1 of 22

Forklift Operator Safety Safe Operation and Pre-Use Inspection

BURR KING FILTERPAK 4001 INSTRUCTION MANUAL BURR KING MFG. CO., INC

Hydraulic Dock Levelers

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES

Hydraulic Fluids and Lubricants Guidelines for Cleanliness

G E N E R A L C AT A L O G

Filtration of Oil and Related Benefits

High Velocity Oil Flushing Contamination Control Oil & Fuel Purification Services

Effluent Decontamination

SEMMME SQA Unit Code H2AF 04 Assembling Fluid Power Components to Mechanical Equipment

Fluid Contamination Under Control with... Innovative Filtration Products, Support, and Solutions.

Maelstrom. Installation and Specification Guide

ADDITIVE DEPLETION: IMPACT ON USEABLE OIL LIFE AND EQUIPMENT WEAR

12/11/2017 HOW TO DETERMINE THE BAFFLE FACTOR WHAT IS BAFFLE FACTOR WHAT IS NEW ORIGINAL UT TANK, NO INTERNAL WATER ROUTING IMPORTANCE OF WELL TANKS

The Most Effective Method to Clean a Well uses Well Guard

Sawyer Water filters. Clean Water for Life. India and Kenya. Project Overview

High Pressure Filters Worldline 100 HD 049 HD 069. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to 27.7 gpm. 40.

CRITICAL FUEL FILTRATION SYSTEM For Fuel Storage Up To 10,000 Gallons (38,000 liters)

HD 790 HD 990. In-line mounting Operating pressure up to 6525 psi Nominal flow rate up to 265 gpm us d

A Publication of the Lubrication Engineers Technical Department LEADERS IN LUBRICANTS NUMBER 62

Valve Nest Filter with Time Clock Control Installation and Operation Manual

ARCHITECTURAL DESIGN SPECIFICATIONS CRB CRASH BEAM VEHICLE BARRIER. PART I General

TWIN LASER PARTICLE COUNTER

TROUBLE SHOOTING STEAM TURBINE PHOSPHATE ESTER EHC SYSTEMS

EPK- EasyTest Patch Test Kit Manual

Glycol Management Paper. By Niels Bogh

M a i n t e n a n c e. O i. CJC TM FineFilter

HD 152 HD 172 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to 190 l/min

Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523

Filtration Systems. Innovative solutions to tough filtration problems.

2200-Lb. Semi-Electric Stacker OWNER S MANUAL

HIGH PERFORMANCE FILTER MEDIA HYDRAULIC AND LUBRICATING SYSTEMS

DIAGNOSTICS: COLLECTION TO DETECTION. Results that matter.

Contamination Guide for Hydraulic Fluids, Oils and Diesel Fuels

PERISTALTIC PUMPS FOR USE IN THE FIELD

PAHT C pumps ATEX PAHT C pump

Undercarriage. product and support

ESSENTIAL FOR SURVIVAL

Engineering Excellence

Waterworks. QUT Extreme Science

Basics of Oil Condition Monitoring Through Oil Analysis Marian Kiley Key Account Manager Analysts, Inc.

S800-Direct Flow USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

To demonstrate how farmers apply liquid pesticides to crops. To identify effective application devices and methods.

FILTRATION: ALL ARE NOT CREATED EQUAL

2200 lb. Semi-Electric Stacker

Welcome to Parker s Involvement Training Program

Crossflow Filtration for Ink Jet Fluids

You may choose to use a filter as part of your water treatment system. Focus your work at this station on these three questions:

Transcription:

Hydraulic Fluid Contamination and Assessment Presented by: Ernie Parker Fluid Power Engineering Technology Instructor Hennepin Technical College 1

About 95% of all hydraulic problems are cause by heat, assembly, and contamination. Heat problems are generally a design problem. Assembly could be improper hose installation. Contamination is everyone s concern. 2

You are a Fluid Power Machine Pump Heart Arteries Pressure Lines Veins Return Lines Kidneys Filter Kidney Loop Off-line Filtration Muscles Cylinders & Flow Controls Brain PLC (Programmable Logic Controller) Our Sensors (Sight, Smell, Touch, & Hearing, - Instrumentation Nervous System Servos & Proportional Control Systems Lungs Pneumatic System 3

How careful do you want a hospital and doctor to be when working on you? That is how you should treat a hydraulic system, with the same cleanliness as human surgery. 4

Sizes of Particles in Micro-meters Grain of Table Salt 100 Human Hair 70 Lower Limit of Visibility 40 White Blood Cells 25 Red Blood Cells 8 Average Bacteria 2 100 mesh screen = 149 325 mesh screen = 44 1 micro-meter =.000039 in or 39/1,000,000 of an inch 5

Sources of Contamination 1. New Oil 2. From manufacturing and handling of components during shipping and fabrication 3. Ingressed contamination 4. Wearing of components 6

7 Particles found in new fluids range from rust, dirt, sand, & water from either condensation or leakage into a container from sitting in the elements. Examples of Water Take a five gallon pail that has been empty and screw the cover back on and leave it outside in the rain. After a couple of good rains, you may have ¼ of water in the bottom of the pail and yet the cap was screw on tightly.

When stored properly, one can still find various particles. New oil has a rating of approximately 33 micron or 17/16/14 on the ISO 4406 chart from a reputable supplier. The Hydraulic Specialist study guide suggests that new oil is in the range of 20/18/14. That means there are between 81 and 160 particles 14 micron in size per ml. 8

9

10

11

Where does manufacturing contamination come from? 12 Components ports not plugged Components stored in bad environment Pumps/motors prefilled with dirty or unfiltered oil Use of floor dry or similar oil absorbents in shop areas Dirty hands, shop rags & lint used during assembly Dirty work benches Dirty oil in test bench use to performance check components Welding and fabrication contaminate Broken tools during manufacturing Fittings laying around and not cleaned Dirty hoses from assembly that were not cleaned and capped Assembly in a fabrication environment Dirty manufacturing procedures Dirty cutting fluid Improper flushing techniques Is a high enough velocity used to create flow turbulence when flushing parts? Dirty ports plugs Shop rags used to plug ports Not cleaning around ports before removing plugs for assembly Reservoirs not clean properly before assembly Filters on the shelve but not in sealed container

Contamination Types and Sources 13

Contamination Types and Sources 14

15

16

Contamination Types and Sources 17

Contamination Types and Sources 18

Contamination Types and Sources 19

20

21

Contamination Basics 22

Ingressed Contamination Reservoir vent port Access covers not sealed Components ports left open Cylinder wiper seals damage by outside sources such as rust or nicks in rods Cavitation Wear of components cause by dirty oil or too low of viscosity of oil Wrong or poor additives Too course of filtration 23

Wearing of Components 24

25

26

27

Examples of Wear on Components 28

29

30

31

32

33

Special Thanks Thanks to our industry partners for their contribution with this presentation: Eaton/Vickers Corporation & Parker Hannifin Corporation Please continue your education by checking out the following: The Systemic Approach to Contamination Control By Vickers The Handbook of Hydraulic Filtration By Parker 34