EXPERIMENTAL STUDY OF EFFECT OF END SILL ON STILLING BASIN PERFORMANCE

Similar documents
Design of Stilling Basin Model with Impact Wall and end Sill

STUDY OF SHAPE OF INTERMEDIATE SILL ON THE DESIGN OF STILLING BASIN MODEL

Objective Questions:-

Analysis of Side Sluice in Trapezoidal Channel

UNIT I: UNIFORM FLOW PART B

Pawana Dam Energy Dissipation A Case Study

International Journal of Civil Engineering and Technology (IJCIET), ISSN (Print), INTERNATIONAL JOURNAL OF CIVIL ENGINEERING

International Journal of Civil Engineering and Technology (IJCIET), ISSN (Print), INTERNATIONAL JOURNAL OF CIVIL ENGINEERING

(b) Discuss in brief shaft spillway with neat sketches. Marks 04. OR Q (2) Explain in brief USBR stilling basin. Marks 08


THE CHANGES OF FLOW PROFILE DUE TO THE CONSTRUCTION OF CYLINDRICAL STRUCTURE AS A HYDRAULIC CONTROL STRUCTURE IN OPEN CHANNEL

Open Channel Flow. Ch 10 Young, Handouts

DETERMINING THE ADEQUATE CREST HEIGHT OF SUPPRESSED RECTANGULAR BROAD CRESTED WEIRS UNDER SUB- CRITICAL FLOW CONDITIONS

Asst.Prof.Dr. Jaafar S. Maatooq. 1 st Semester HYDRAULIC STRUCTUER, KINDS & FUNCTIONS 1 of 26

IMPACT AND PUNCTURING OF JARI TUNNEL AND ENLARGEMENT OF EXISTING TAPPINGS FOR ADDITIONAL WATER SUPPLY AND POWER GENERATION

EXAMPLE SHEET FOR TOPIC 2 AUTUMN Q1. What is the significance of the Reynolds number Re for the flow of fluid in a circular pipe?

DETERMINATION OF DISCHARGE COEFFICIENT AND HEAD-DISCHARGE RELATIONSHIPS OF DIFFERENT HYDRAULIC STRUCTURES

PRELIMINARY DESIGN OF THE HYDRAULIC STRUCTURES DAM IN THE PISÃO RIVER

Hydraulic Jumps. CIVE 401: Fall Team 10: Yalin Mao, Natalie Pace, Kyle Nickless. November 19, 2014

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL COLLEGE FZE BENG (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2015/2016

Energy Dissipation over Stepped Gabion Weir

Practical Hydraulics on a Large Wastewater Treatment Works

Lab #3 Conservation Equations and the Hydraulic Jump CEE 331 Fall 2004

Lab #3 Conservation Equations and the Hydraulic Jump CEE 331 Fall 2003

LOCAL SCOUR AROUND SPUR DIKES

Drop Height For Channel Erosion Control

CVE 372 HYDROMECHANICS OPEN CHANNEL FLOW I

HYDRAULIC DEMONSTRATION CHANNEL

Irrigation Structures 2. Dr. M. R. Kabir

Stilling basin design for inlet sluice with vertical drop structure: Scale model results vs. literature formulae

Physical models application of flow analysis in regulated reservoir dams

water ISSN

14. SCREENS. in the Figure 8.1. BARS TROUGH

Effect of Types of Weir on Discharge

Energy Dissipation within In-Ground Stilling Basin

of the Crump weir Modelling of composite type variation

Water Control Structures Selected Design Guidelines Alberta Environment Page 17-1

CE2253 APPLIED HYDRAULIC ENGINEERING (FOR IV - SEMESTER)

Low Gradient Velocity Control Short Term Steep Gradient Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent [1]

Outlet Flow Velocity in Circular Culvert

CLEAR-WATER AND SEDIMENT-LADEN-FLOW TESTING OF THE E-TUBE SEDIMENT RETENTION DEVICE

Lab 3: Conservation Equations and the Hydraulic Jump

EFFECT OF NANO-CEMENT IN REDUCING THE VALUE OF ROUGHNESS COEFFICIENT

Effective Analysis by Arrangement of Multi-Baffle at Weir Downstream

Advances in Environmental Biology

3D JET FLOW BEHAVIOUR AROUND A PILE IN A SCOUR HOLE

Factors Affecting Air Entrainment of Hydraulic Jumps within Closed Conduits

Effect of Wedge Shape Deflector on Dissipating Energy in Triangular Flip Buckets

CE6403 APPLIED HYDRAULIC ENGINEERING UNIT 1 UNIFORM FLOW

Influence of Supply-Channel Velocity on Farm Delivery Meter Gate Flow Measurement

Chapter 10. Conduit Outlet Structures Introduction General Layout Information

SURFACE-RUNOFF CHARACTERISTICS UNDER SIMULATED RAINFALL CONDITIONS ABSTRACT

Development of transition mat scour protection design methodology and comparison to the state-of-the-practice

North Domingo Baca Extension at Barstow

Coefficient of Discharge and Energy Loss Attained Over a Sharp Crested Rectangular Weir

Experiment No.2 STUDY & TRIAL ON A FRANCIS TURBINE & PLOTTING OF MAIN /OPERATING CHARACTERISTICS.

Measuring flow in open channels (weirs)

Experimental Study of Triangular Sharp-Crest Weir in Open Channels

CE 6403 APPLIED HYDRAULIC ENGINEERING (REG -2013)

THE CONSTRUCTION PHASES OF THE NEW NAGA HAMMADI BARRAGE COFFERDAMS

Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7: Hydraulic Design of Sewers and Storm Water Drains

Level 6 Graduate Diploma in Engineering Hydraulics and hydrology

GEOMORPHIC EFECTIVENESS OF FLOODS ON LOWER TAPI RIVER BASIN USING 1-D HYDRODYNAMIC MODEL,HEC-RAS

Lateral Outflow from Supercritical Channels

Index. Page numbers followed by f indicate figures.

CTB3365x Introduction to Water Treatment

C-3-1. Inlet Flumeat Gate. BoxCulvert (Open Flow) MainCanal(C 1) km Outlet Flume. BoxCulvert (OpenFlow) WL m. WL.40.

Flow Measurement for Structure Assessment in Richmond Irrigation District

Sump Pumps Office procedures for the Drainage & Grading section

Learning objectives. Upon successful completion of this lecture, the participants will be able to:

Flow Measurement Structure Assessment

WSUD On-site Detention in xprafts 2013

The Head Loss Ratio in Water Distribution: Case Study of a 448- Bed Student Hostel

Experimental Investigation Of Flow-Interactions Between Above And Below Ground Drainage Systems Through A Manhole

Created by Simpo PDF Creator Pro (unregistered version) Asst.Prof.Dr. Jaafar S. Maatooq

Index. outlet protection Rev. 12/93

INVESTIGATION OF FLOW CHARACTERISTICS DOWNSTREAM RADIAL GATES OF NAGA HAMMADI BARRAGES PHYSICAL MODEL

HY-12 User Manual. Aquaveo. Contents

WATER SUPPLY ENGINEERING

Use of IDF Curves Design of a roof drainage system

Water Conveyance System

Anti-vortex structures at hydropower dams

EXHIBIT 2:Optional Online Installation Re-entrainment/scour testing of the Terre Kleen18 Hydrodynamic Separator Stormwater Treatment unit per NJDEP

Sanitary and Environmental Engineering I (4 th Year Civil)

New Developments in Design and Application of Long-Throated Flumes

Inflow pipe. Drain. Drain

Module 3. Irrigation Engineering Principles. Version 2 CE IIT, Kharagpur

CHAPTER 2: Pressure piped irrigation techniques

Oxygen Transfer and Energy Dissipation by Nappe and Skimming Flow over Stepped Weir Structure

Literature Review and Objectives of Study

SETTLING REVIEW CHECKLIST

FINAL Examination Paper (COVER PAGE) Programme : Diploma in Mechanical Engineering. Time : 8.00 am am Reading Time : 10 Minutes

CE Hydraulics. Andrew Kennedy 168 Fitzpatrick

Hydraulics of Jinnah Barrage; Existing Structure and Rehabilitation Alternatives

Contents Page. Foreword... xi. 9.8 Pump intake design Introduction Purpose Scope...1

DHANALAKSHMI COLLEGE OF ENGINEERING, CHENNAI DEPARTMENT OF CIVIL ENGINEERING CE 6403 APPLIED HYDRAULIC ENGINEERING UNIT I: UNIFORM FLOW

Basic Design of Replogle Flumes

2. Fluid Mechanics Consideration The present study concern with three different shape of combined hydraulic structure or device (weir-gate) these are

Design Modification of Sedimentation Tank Ashutosh Kumar Mall 1, Dr. ShriRam 2

APPLICATION OF 1-D HEC-RAS MODEL IN DESIGN OF CHANNELS

Transcription:

EXPERIMENTAL STUDY OF EFFECT OF END SILL ON STILLING BASIN PERFORMANCE H.L.Tiwari Department of Civil Engineering, Maulana Azad National Institute of Technology, Bhopal, Madhya Pradesh INDIA Arun Goel Department of Civil Engineering, National Institute of Technology, Kurukshetra, Haryana, INDIA. V. K. Gahlot Department of Civil Engineering, Maulana Azad National Institute of Technology, Bhopal, Madhya Pradesh INDIA Abstract This research paper presents an experimental study of end sill for new stilling basin models in dissipation of energy for a rectangular shaped pipe outlet of size 10.8cm x 6.3 cm. The models were tested for three Froude numbers namely 1.85, 2.85 and 3.85 in the laboratory. The new models are developed by changing the shape of end sill. The scour (magnitude and location) after the end sill were measured for each model. The results have indicated that for all flow conditions, the sloping end sill is more effective in lowering the downstream kinetic energy than other end sills tested, Keywords: Scour, Stilling basin, Froude number, End sill. Introduction End sill plays an important role in the design of stilling basin for reducing the length of it and also helps to improve the flow pattern downstream of the channel. End sill my be defined as a vertical,stepped, sloped or dentated / solid wall at the downstream end of the stilling basin, Edward, A(1959). Stilling basins are employed for the purpose of dissipating the excessive energy downstream of hydraulic structures like overflow spillways, sluices, pipe outlets etc. Various types of recommended stilling basin designs for pipe outlets recommended are by Bradely and Peterka (1957), Fiala and Albertson (1961), Keim (1962), Flammer et al. (1970), Vollmer and Khader (1971) Garde and Saraf (1986), Smith (1988), Goel and Verma (1999, 2001) and Goel (2008) etc. In all above mentioned studies, end sills used are either sloping Peterka (1957), or semicircular, Goel and Verma (2000). The previous models developed by past investigators are either too long or not working efficiently except the models developed by Goel (1999, 2001, 2008) which are applicable to circular shaped outlets only. The present research paper concentrates to study the effect of the shape &size of the end sill to develop new models for rectangular pipe outlet stilling basin. Experimental arrangement The experiments were conducted in a recirculating laboratory flume of 0.95 meter wide, 1 meter deep and 25 meter long in the hydraulics laboratory of M AN I T Bhopal. The width of flume was reduced to 58.8 cm. by constructing a brick wall along the length for suiting the requirement of width as per design considerations suggested by Bradely and Peterka (1957). A rectangular pipe of 10.8 cm x 6.3 cm was used to represent the outlet pipe. This pipe was connected with delivery pipe of diameter of 10.26 cm installed in the centrifugal pump. The exit of outlet pipe was kept above stilling basin by one equivalent diameter (d = 9.3 cm) as per the design. A wooden floor of size 58,8cm wide and 78.6 cm long was provided, downstream of the outlet for fixing the appurtenances in the basin. Three inflow Froude numbers namely Fr = 1.85, 2.85 and 3.85 were fixed as per discharge consideration in the flume. To observe the scour after the end sill of stilling basin, an erodible bed was consisting of coarse sand passing through IS sieve opening size 2.36 mm. and retained on IS sieve opening size 1.18mm was provided. The bed material size was selected on trial basis in such a way that even for a minimum Fr = 1.85, a measurable scour occurs and for maximum Froude number Fr = 3.85, the bed of flume is not exposed within a stipulated period of running time which was chosen as one hour for each model ISSN : 0975-5462 Vol. 3 No. 4 Apr 2011 3134

testing. A manual tail gate was used at the end of the flume to control the tail water depth in the flume for experimentation. The time for each test run was kept as one hour. The one hour duration was found to be sufficient as 90% of the scour occurred in 45 min for range of Froude numbers used as observed by experimental run, conducted as a trial at the beginning of the testing. The maximum depth of scour (d m ) and its distance from end sill (d s ) was measured for each test run after one hour run time. The depth of flow over the erodible bed was maintained equal to the normal depth of flow, which was computed by Manning s formula corresponding to the inflow Froude number Fr=V/(gd) 0.5,where V is the average velocity in the pipe, g is the acceleration due to gravity and d is the equivalent diameter of the pipe. The erodible sand bed was leveled up to the top of the end sill for observation of the scour pattern. First of all bed material was filled up to the height of end sill and get leveled then normal depth was maintained over the sand bed by allowing the water from the overhead tank inside the flume by operating the tail gate. After that centrifugal pump of capacity 20 HP was switched on, keeping the control valve closed, fitted into the feeding pipe. The flow into the flume was increased gradually so as to achieve required Froude number with a minimum possible disturbance to the erodible sand bed. The discharge was measured by a calibrated venturimeter installed in the delivery pipe. With the operation of tail gate, the desired steady flow condition with normal depth was maintained. After one hour test run, the motor was switched off. The value of maximum depth of scour (d m ) and its location from the end sill (d s ) were noted. All the models were tested for constant run time of one hour and with the same erodible material for three Froude numbers namely 1.85, 2.85 and 3.85. Different stilling basin models were tested by changing shape of end sills. Scheme of experimentation First of all basin floor was designed for the inflow Froude number (Fr = 3.85 ) and was fabricated in the flume as per USBR impact type model,which consists of an impact wall of size 1d x 2.2d with a bottom gap 1d, located at 3d from exit of pipe outlet and followed by sloping end sill of height 1d positioned at 8.4 d where d is the equivalent diameter of the pipe outlet. Later on, in order to study the effect of end sill shape, new stilling basin models were fabricated by changing shapes of end sills (06 Models) fig. no. 1-2. During the test runs for all the stilling basin models, the grain size of the material forming the erodible bed and test run time were kept the same. The details of new models have been mentioned in Table No 1. Model number Stilling basin length L Size Table No. 1 Impact wall with hood Location from outlet exit Bottom gap with basin floor End sill shape with height d MSM-1 8.4d - - - Plane rectangular MSM-2 8.4d - - - Square MSM-3 8.4d - - - Sloping(1V:1H) with vertical face D/S MSM-4 8.4d 1dx2.2d 3d d Plane Rectangular MSM-5 8.4d 1dx2.2d 3d d Square MSM-6 8.4d 1dx2.2d 3d d Sloping(1V:1H) with vertical face D/S ISSN : 0975-5462 Vol. 3 No. 4 Apr 2011 3135

Figure No. 1, New Stilling Basins with end sill only ISSN : 0975-5462 Vol. 3 No. 4 Apr 2011 3136

MSM- 4 MSM- 5 MSM- 6 Fig. 2 Variation of shapes (Rectangular (MSM-4), square (MSM-5), triangular (MSM-6)) of end sill with USBR type impact wall ISSN : 0975-5462 Vol. 3 No. 4 Apr 2011 3137

Performance evaluation The performance of stilling basin tested for different Froude number (Fr) is a function of channel velocity (v), the maximum depth of scour (d m ) and its location from end sill (d s ). A stilling basin model that produces smaller depth of scour at a longer distance is consider to have a better performance as compared to another stilling basin which results in a larger depth of scour at a shorter distance when tested under similar condition. Verma & Goel (2003). A non dimensional scour index (2d m /d s ), Goel & Verma (2001), has been considered for comparison of performance of stilling basin models. A smaller value of scour index shows better performance of stilling basin models. The value of scour indices for various runs on each model for different Froude numbers are given in Table No. 2. Table no. 2 Values of Scour Index (tan α = 2d m/d s) S No. Model No. Scour index Fr = 1.85 Fr = 2.85 Fr = 3.85 Remarks 1 MSM 1 0.965 0.946 0.927 Scour Index higher side 2 MSM -2 0.847 0.903 0.867 Scour Index higher side 3 MSM - 3 0.800 0.883 0.757 Better performance 4 MSM-4 0.826 0.844 0.747 5 MSM-5 0.680 0.710 0.656 6 MSM-6 0.609 0.705 0.593 Better performance than all above Result and discussion Figure No.3 Scour Profile In the beginning stilling basin models (MSM-1, MSM-2 and MSM-3) were tested with end sills of rectangular, square and sloping only for Fr = 1.85, 2.85, 3.85, and value of scour indices were mentioned in the table no. 2. It was found that without impact wall scour indices were on higher side as shown in bar chart in figure no. 6. The USBR impact type VI model (MSM-6) as shown in Fig. 2 for Fr = 1.85, 2.85, 3.85 was tested and the values of scour indices are mentioned in Table 2. The Impact wall of height 2.2d with a bottom gap of 1d was placed at 3d from the exit of the pipe outlet. Although USBR model was designed for Fr = 3.85, test were also conducted for Froude numbers 1.85 and 2.85 for rectangular pipe outlet. Keeping in view the performance of USBR model (MSM-6), the new models were tested by changing shape of end sill while keeping impact wall at same place. Models MSM -4, a square size of 1dx1d and in model MSM-5 a rectangular end sill of size ( d ) were tested and values of scour indices are mentioned in the Table 2. Comparison of performance of models ISSN : 0975-5462 Vol. 3 No. 4 Apr 2011 3138

MSM-4 to MSM-6 shows that sloping end sill performs better as shown in figure no.4. The model MSM-4 having rectangular end sill further goes down as compared to model MSM-5 with square end sill and far inferior as compared to model MSM-6 as shown below. Figure No. 4 Figure No. 5 Conclusions An experimental investigation was conducted in a laboratory to study the effect of shape of end sill for rectangular pipe outlet basin. It was concluded that the shape of end sill in a basin affects significantly the maximum scour depth and hence scour index. The reduction rate depends upon the type of end sill geometry. The shape of end sill also affects the flow pattern and scour pattern downstream of pipe outlet basin. Experimental study reveals that the sloping end sill(1v:1h) with vertical face upstream dissipates more kinetic ISSN : 0975-5462 Vol. 3 No. 4 Apr 2011 3139

energy for all flow conditions as compared to other end sills tested for rectangular pipe outlet basin. There is a scope to reduce the length of pipe outlet stilling basin by way of experimentations. References [1] Bradley, J.N. and Peterka, A. J. (1957) Hydraulic Design of Stilling Basins, (1-6 Papers). Journal of A.S.C.E., Hydraulic Engg, October, pp.1401-1406. [2] Elevatorski, Edward, A. Hydraulic Energy Dissipators. McGraw Hill Book Company, Inc., New York. 1959. [3] Fiala, J. R. and Maurice, L. Albertson ( 1961) Manifold Stilling Basins. Journal of A.S.C.E., Hydraulic Div. No 4, Vol. 87, Paper no 2863, pp.55-81. [4] Flammer, G.H, G.V.Skogerboe, C.Y. Wei and H. Rasheed (1970) Closed Conduit to Open Channel Stilling Basins. Journal of A.S.C.E., Irrigation and Drainage Div, Vol.96, paper 7124, pp.1-1., [5] Garde, R.J. and Saraf, P.D. (1986) Evolution of Design of Energy Dissipator for Pipe Outlets. J. of Irrigation & Power, July, pp.145-154. [6] Goel, A. and Verma, D.V.S (2000) Stilling Basins for Outlets Using Wedge Shaped Splitter Blocks Journal of Irrigation and Drainage Engineering, American Society of Civil Engineering (ASCE), May/June, pp.179-184. [7] Goel, A. and Verma D.V.S. (2001) Model Studies on Stilling Basins for Pipe Outlets. J. of Irrigation and Drainage Systems, Kluwer Academic Publisher, The Netherlands, Vol.15, No.1. 81-91. [8] Goel A. (2008) Design of Stilling Basin for Circular Pipe Outlet. Canadian Journal of Civil Engineering, Vol. 35, No. 12, pp. 1365-1374. [9] Goel, A. and Verma, D.V.S (2003) Development of Efficient Stilling Basins for Pipe Outlets Journal of Irrigation and Drainage Engineering, American Society of Civil Engineering. May/June, pp.194-200. [10] Keim, S.R. (1962) Contra Costa Energy Dissipator. Journal of A.S.C.E., Hydraulic Division, Paper 3077, March, pp. 109-122. [11] Vollmer, E. and Khader M.H.A.( 1971) Counter Current Energy Dissipator for Conduit Outlets. International J. of Water Power, July, pp. 60-263. ISSN : 0975-5462 Vol. 3 No. 4 Apr 2011 3140