Study on the Treatment of Effluents from Paint Industry by Modified Electro-Fenton Process

Similar documents
DECOLOURISATION OF REACTIVE BLUE 28 FROM DYE WASTE WATER BY PHOTO FENTON PROCESS AND SONO FENTON PROCESSES

Application of a hybrid Electrocoagulation-Fenton process in yarn dye wastewater: Kinetic study

Using an anodic Fenton process for degradation of nitrobenzene in waste water

REDUCTION OF COD IN WASTEWATER FROM A TEXTILE INDUSTRY BY ELECTRO-FENTON PROCESS

Investigation of Color Removal of Sunflower Oil Industrial Wastewater with Fenton Process

A Research on treatability of leather industry wastewater by using electro-fenton process

Distillery Wastewater Decontamination by the Fenton Advanced Oxidation Method

Fenton Oxidation Process Control Using Oxidation-reduction Potential Measurement for Pigment Wastewater Treatment

Available online at Scholars Research Library. Archives of Applied Science Research, 2011, 3 (2):

HKICEAS-671 Optimization of Reactive Dyes Degradation by Fenton oxidation Using Response Surface Method

Removal of Malachite Green Dye from aqueous solution by Fenton Oxidation

Pelagia Research Library

International Journal of Innovative Research in Science, Engineering and Technology. (An ISO 3297: 2007 Certified Organization)

The Performance of Electro-Fenton Oxidation in the Removal of Pesticides from Wastewater Using Stainless Steel Electrodes

Advanced Oxidation Process for Wastewater Treatment: A Review

INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCES Volume 6, No 6, Copyright by the authors - Licensee IPA- Under Creative Commons license 3.

DECOMPOSITION OF NON-IONIC SURFACTANT SYMPERONIC NP10 BY THE FENTON PROCESS IN THE PRESENCE OF IRON-OXIDE NANOPARTICLES

Treatment of non-biodegradable wastewater by electro-fenton method

Removal of Water Turbidity by the Electrocoagulation Method

Color and COD removal from waste water containing acrylic water base color using Fenton's oxidation process

Photo-Oxidation Process Application for Removal of Color from Textile Industry Effluent

Electrocoagulation Of Distillery Spentwash For Complete Organic Reduction

Optimization of COD and Colour Removal From Landfill Leachate by Electro-Fenton Method

Electrochemical Treatment Of Rice Grain Based Distillery Effluent Using Iron Electrode

Treatment of Dye Intermediate Waste-Water by Fenton and Electro-Fenton Treatments

COMPARISON OF FE AND AL ELECTRODES IN THE TREATMENT OF BLUE CA DYE EFFLUENT USING ELECTRO COAGULATION PROCESS.

Assessment of Electrocoagulation for Groundwater Purification

Original Research The Modified Fenton Process for Decolorization of Dye Wastewater. K. Barbusiński*

Treatability studies on bleach effluent of pulp and paper industry by ultraviolet/hydrogen peroxide process with titanium dioxide as catalyst

Electrochemical Degradation of Acridine Orange Dye at Ru-Doped Platinum Anode in Aqueous Solution

OXIDATIVE TREATMENT BY HYDROGEN PEROXIDE FOR THE REMOVAL OF COD AND SULPHIDE FROM TANNERY LIMING WASTEWATER

SUBSEQUENT FENTON PROCESS AND NEUTRALIZATION FOR WASTEWATER TREATMENT OF TEXTILE HOME INDUSTRY

Reduction of Biochemical Oxygen Demand and Chemical Oxygen Demand of Metalworking Fluid Wastewater by Electrochemical Oxidation

Analytical & Bioanalytical Electrochemistry

Electrochemical Oxidation of Textile Industry Wastewater Using DSA In Tubular Reactor

DECOLORIZATION AND BIODEGRADABILITY OF DYEING WASTEWATER TREATED BY A TIO 2 -SENSITIZED PHOTOOXIDATION PROCESS

Aerobic Sludge Digestion in the Presence of Chemical Oxidizing Agents Part II. Fenton's Reagent

Discoloration of Azo Dye Acid Red 18 by Fenton Reagent in the Presence of Iron Powder

Advanced Treatment of Pistachio Processing Industry Wastewater by Fenton Process

Removal of Dye from Textile Wastewater by Electrolytic Treatment

Pilot Study on Advanced Treatment of Wastewater Produced by Pressurized Coarse Coal Gasification

Advances in Diamond Electrochemistry: Applications in Industrial Wastewater Treatment

Advanced systems for the enhancement of the environmental performance of WINEries in Cyprus

Advanced Oxidation Processes for Wastewater Treatment in the Pulp and Paper Industry: A Review

Decolorization of the dye reactive black 5 using Fenton oxidation

COD AND COLOR REDUCTION BY CATALYTIC TREATMENT OF DISPERSE DYE WASTE WATERFROM TEXTILE INDUSTRY

Electrocoagulation in a Plugflow Reactor: The Treatment of Cattle Abattoir Wastewater by Iron Rod Anodes

Paracetamol degradation in water by non-thermal plasma and heterogeneous catalysis coupling

Oxygen Demand, Chemical

Influence of operating parameters on ammonia nitrogen removal from micro-polluted water by electro-coagulation-flotation with aluminum electrodes

TREATMENT OF TEXTILE EFFLUENT USING HETEROGENEOUS FENTON AND MICROFILTRATION

Decolourisation of Synthetic and Textile Wastewater by Fenton Process

Mat E 272 Lecture 26: Oxidation and Corrosion

Textile wastewater treatment: colour and COD removal of reactive black- 5 by ozonation

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

TREATING WASTE WATER USING ELECTROCOAGULATION APPROACH

Decolorization of Textile Wastewater by Electrochemical Process in the Presence of Hydrogen peroxide and Poly Aluminum Chloride

Experimental technique. Revision 1. Electroplating an iron key with copper metal

FS-TER-006 FENTON REACTIONS SERIES: TERTIARY TREATMENTS TECHNICAL SHEETS FOR EFFLUENT TREATMENT PLANTS IN TEXTILE INDUSTRY

Journal of Engineering Science and Technology Review 9 (1) (2016) Research Article

TREATMENT OF TEXTILE EFFLUENT USING PHOTO-FENTON PROCESS IN PRESENCE OF BANANA PEEL AS AN ADSORBENT

An Efficient-Green-Catalytic Process For Degradation Of Organic Pollutants In Industrial Waste Waters

Carbon Electrodes for the Electro Accumulation of Potassium from Distillery Spentwash

NAPHTHA REMOVAL FROM PETROLEUM INDUSTRIAL EFFLUENT

Study the Efficiency of Various Metal Powder Composition Electrodes Based on Landfill Leachate Treatment

Electrochemical Treatment of Acid Green V dye solution in a tubular flow reactor

Degradation of organic compounds by fluidized bed fenton process

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement

Process water treatment by oxidative and electrolytic

TREATMENT OF COLORED DOMESTIC WASTEWATER BY ELECTROCOAGULATION

Study of Electrochemical Degradation of Bromophenol Blue at Boron-doped Diamond Electrode by Using Factorial Design Analysis

Treating oil wastewater with pulse electro-coagulation flotation technology

Advanced Oxidation Processes: Treatment of 1,4-Dioxane and VOCs for Potable Water Applications

CHAPTER 5 ELECTROCHEMICAL TREATMENT

Removal of COD and Colour from Sanitary Landfill Leachate by using Coagulation Fenton s Process

Oxygen Demand, Chemical

Fenton's catalytic oxidation process to treat landfill leachate

European PhD School on Advanced Oxidation Processes

Enhancing Environmental Monitoring Using Total Organic Carbon (TOC)

RESEARCH ARTICLE. Background. Amir Sheikh Mohammadi a, Ahmad Reza Yazdanbakhsh b*, Mahdieh Sardar a

Development of electrodes for use in Microbial Fuel Cells for wastewater treatment and power generation

Dicolorization of Reactive Dyes in Aqueous Solutions Using Ionizing Electron Beam Radiation

METAL FINISHING. (As per revised VTU syllabus: )

Complete oxidation of organic substances in wastewater using an Advanced Oxidation Process with synthetic diamond electrodes

Comparative analysis of the treatment of Reactive Azo dye using Fenton and photo Fenton treatment

A New Development For (Textile Mill) Wastewater Treatment. Prepared for Publication in The American Dyestuff Reporter June 1988

Electrocoagulation. Achieving clean, clear, treated and reusable water: The process, technology and benefits. CALL US (631)

Azmi Aris, Ooi Boon Siew, Kon Suh Kee, Zaini Ujang

Use of Fenton Reagent as Advanced Oxidative Process for Removal of Basic and Acid Red Dyes from Aqueous Solutions

Novel Pretreatment Enables Performance of MBR Installed to Treat Oily Wastewater

Control of the Physical and Technical Properties of Water in Technological Processes

RecShow '08. Middle East Recycling, Waste & Environmental Management Exhibition & Congress. Kempinski Hotel, Dead Sea - Jordan February 2008

Remediation of 1, 4-Dioxane

APPLICATION OF IRON NANOPARTICLES FOR INDUSTRIAL WASTEWATER TREATMENT. Martina SUKOPOVÁ*, Jana MATYSÍKOVÁ*, Ondřej ŠKORVAN*, **, Marek HOLBA*,***

CORROSION of Metals CORROSION CORROSION. Outline ISSUES TO ADDRESS... Why does corrosion occur? What metals are most likely to corrode?

CHAPTER 2 LITERATURE REVIEW AND SCOPE OF THE PRESENT STUDY

Treatment of Pollutants in Industrial Wastewater Using Fenton s Oxidation Process: An Overview

Concentration mg/l TDS mg/l 10, ,000 Recovery 75% Waste TDS mg/l 44,000 COD mg/l 3,500 0 BOD NTU 1,250 0 Power Used kwh/m3 2.

TREATMENT OF INDUSTRIAL WASTEWATER BY SOLAR NANO PHOTOCATALYSIS

Transcription:

American Journal of Chemical Engineering 2016; 4(1): 1-8 Published online January 25, 2016 (http://www.sciencepublishinggroup.com/j/ajche) doi: 10.11648/j.ajche.20160401.11 ISSN: 2330-8605 (Print); ISSN: 2330-8613 (Online) Study on the Treatment of Effluents from Paint Industry by Modified Electro-Fenton Process Ahmed Mostafa Sadek 1, *, Riham Ali Hazzaa 2, Mohamed Hussien Abd-El-Magied 1 1 Chemical Engineering Department, Alexandria University, Alexandria, Egypt 2 Petrochemicals Engineering Department, Pharos University, Alexandria, Egypt Email address: amsadek@ethydco-eg.com (A. M. Sadek) To cite this article: Ahmed Mostafa Sadek, Riham Ali Hazzaa, Mohamed Hussien Abd-El-Magied. Study on the Treatment of Effluents from Paint Industry by Modified Electro-Fenton Process. American Journal of Chemical Engineering. Vol. 4, No. 1, 2016, pp. 1-8. doi: 10.11648/j.ajche.20160401.11 Abstract: The main goal of this study is to investigate the effectiveness of modified Electro-Fenton process (EF-Fere) involving ferrous ions regeneration coupled with direct oxidation method on COD reduction of paint manufacturing wastewater. The present Electro-Fenton cell consisted of stainless steel porous cathode and lead anode covered by PbO 2 film. The performance was measured through studying the effect of different parameters on the percentage of COD removal such as: ferric ions concentration, initial concentration of wastewater, current density and irradiation of UV light. The parameters showed high COD removal efficiency 99% for highly contaminated wastewater of 13000 mg/l COD in acidic medium ph=2 at continuous H 2 O 2 feeding dosage of 1.4 ml/min and current density = 19 ma/cm 2 in presence of UV light. Keywords: Paint Manufacturing Wastewater, Fe 2+ Generation, EF-Fere, COD Removal, Direct Oxidation, UV/EF-Fere 1. Introduction Water-based paints generally consist of organic and inorganic pigments and dyestuffs, extenders, cellulosic and non-cellulosic thickeners, latexes, emulsifying agents, antifoaming agents, preservatives, solvents and coalescing agents [1], which, due to their high persistence and toxicity, prove to be diffcult to treat effectively. Advanced oxidation processes (AOPs) have been thought as effective routes for treatment of paint manufacturing wastewater. Paint manufacturing wastewater has many kinds of high concentration complex organic constituents, but the conventional method such as coagulation is not useful for removal of total organic carbon (TOC) and chemical oxygen demand (COD) [2]. Alternative technology has been developed to help solving the problem. Advanced oxidation processes (AOPs) are frequently used to oxidize complex organic constituents found in waste-waters which are difficult to be degraded biologically into simpler end products [3]. Fenton reaction is another option for phenol degradation. The classical Fenton reagent, consisting of the reactions between homogeneous Fe 2+ /Fe 3+ catalysts and hydrogen peroxide (H 2 O 2 ), is highly efficient for the destruction of phenols due to the hydroxyl radicals generated by the Fenton reactions. However, the classic Fenton processes require a strong acid condition (ph < 3) to avoid the hydrolysis of ferrous and ferric ions, and to achieve optimal removal rate of pollutants. Additionally, nonrecyclable soluble iron salts yield large amount of iron oxide sludge, which needs further separation from the treated water [4]. Some AOPs processes based on classic Fenton processes are developed to treat aqueous phenols. Fenton process using zero valence iron [5], Fenton-like reactions [6, 7], photo- Fenton [8, 9], and electro-fenton (EF) [10-13] have been proven effective for the degradation of phenols. For an electro-fenton process, either H 2 O 2 or ferrous ion is continuously generated or regenerated on the electrode and their accumulative concentrations in aqueous solution depend on a competition between their generation rate and consumption rate [14]. Usually the electro-fenton processes can classified into two categories, EF process involving H 2 O 2 generation and EF process involving ferrous regeneration, which can be named as EF-Fere. The efficiencies of both processes can be comparable with the conventional chemical dosing methods [15-17]. More importantly, they can decrease the risk of handling H 2 O 2 reagents, or decrease the production of ferric hydroxide sludge. In this study, we propose an improved EF-Fere process coupled with direct oxidation method for the treatment of

2 Ahmed Mostafa Sadek et al.: Study on the Treatment of Effluents from Paint Industry by Modified Electro-Fenton Process concentrated organics-containing paint wastewater. A porous stainless steel cathode, instead of a plate cathode, is adopted in the electrolytic process. The porous cathode is capable of reducing the ferric species (ferric sulfate or ferric hydroxide sludge) to ferrous species more efficiently. Results obtained with synthetic wastewater having COD of 13,000 to 19000 mg/l. Electro Fenton studies were with current density in the range of 12.6 to 21 ma/cm 2 and H 2 O 2 dosage in the range of 1 to 1.6 ml/min and constant ph values of 2. Experiment were carried out in batch reactor using one cylindrical lead anode covered by PbO 2 film and DC power supply. Factors that affected Fe 2+ generation and chemical oxygen demand (COD) removal efficiency of organics-containing paint wastewater were evaluated in this work. In addition, the UV irradiation is introduced to the electrolytic system to further enhance the efficiency of organics degradation. 2. Experimental 2.1. Chemicals and Materials The wastewater used was prepared in the laboratory with different COD using high grade chemicals and double distilled water. The preparation of the synthetic wastewater is based on the theoretical oxygen demand of each compound then the COD of the wastewater was measured to get the actual value of COD. The wastewater description is given in Table 1. corresponding to current densities of 12.6, 14.7, 19, 21 ma/cm 2, respectively, by using DC power supply. Ferric sulfate was added and dissolved in the organics-containing solution at desired concentration, 1500, 1800, 2000, 2300 mg/l. Hydrogen peroxide was added at desired concentration in continuous feeding mode, 1 ml/min, 1.2 ml/min, 1.4 ml/min, 1.6 ml/min. All the experiments was performed at room temperature 25 C. A magnetic stirrer was used to homogenize the liquid composition. The schematic of the experimental setup is shown in fig. 1. Initial ph was adjusted to a fixed value 2 by using 25 wt.% sulfuric acid. Samples were taken at pre-selected time intervals. For each run contain 800 ml of the organics containing wastewater. The ph was adjusted by the addition of 25 wt% H 2 SO 4 solutions. Hydrogen peroxide (50 wt%) was added at desired concentration in continuous feeding mode. Direct current from the D. C power supply was passed through the solution during the 120 minutes of electrolysis run. Samples were drawn periodically during each experiment. Withdrawn samples were diluted 200 times with distilled water and then COD was measured. The electrodes were washed with H 2 SO 4 solution (25 wt%) before each run in order to remove any adhering scales or oxides and then washed with distilled water prior to use. Table 1. Wastewater description. Organic Compound Oleic acid Benzene n-heptane Tween 80 (emulsifier agent) % of Total COD 50% of Total COD 16.66% of Total COD 16.66% of Total COD 16.66% of Total COD All chemicals are analytical grade. All organics were purified by distillation and dissolved into distilled water as stock solution. Before the EF-Fere experiment, ferric sulfates were added and dissolved in the organics-containing solution. The ph of solution was adjusted with sulfuric acid and NaOH solution. The H 2 O 2 solution (50 wt.%) was used as amendments without dilution. All the solutions were prepared using double distilled water. In addition, potassium dichromate, silver sulfate and mercury sulfate were of AR grade. Porous stainless steel cylinder used as a cathode while cylindrical lead covered by PbO 2 film act as anode (OD=3 cm) and anode effective electrode area was 118.7 cm 2, Pb/PbO 2 anode was prepared in our laboratory and the details can be found in the literature [18]. 2.2. EF-Fere System Batch experiments were performed in cylindrical cell (pyrex glass beaker 1 liter) with 800 ml working volume of concentrated organics-containing wastewater equipped with porous stainless steel cathode while cylindrical lead covered by PbO 2 film act as anode (OD=3 cm) and anode effective electrode area was 118.7 cm 2. The cell was operated in constant current (I) mode 1.5, 1.75, 2.25, 2.5 A, these Figure 1. Experimental schematic diagram. 1-Pb/PbO 2 anode, 2-St. steel porous cathode, 3-electrolytic cell, 4-D-C power supply, 5-Magnetic stirrer, 6-H 2O 2 bottle with flow rate regulator. 2.3. Analytical Method Chemical oxygen demand (COD) of the sample were measured by closed reflux method according to the standard methods for testing material [19]. The samples were tested using COD digestion vials (Hach), where the sample is placed within digestion vials which in turn are heated at 150 C for 2 hours. Digestion vials were then allowed to cool naturally to ambient temperature before having the COD measured. 3. Results and Discussion 3.1. Effect of Ferric Ions Concentration The initial concentration of Fe +3 ions plays an important role in the E-Fenton process. Progress of COD removal with time

American Journal of Chemical Engineering 2016; 4(1): 1-8 3 for different Fe +3 ions (1500, 1800, 2000, 2300 mg/l Fe +3 ) and constant current density, ph and initial COD are shown in figures below. COD removal increases as the concentration of ferric ions and hydrogen peroxide continuous dosage increase, the maximum COD reduction obtained for 2000 mg/l Fe +3 and 1.4 ml/min continuous dosage of H 2 O 2 was 90%. As can be observed, when the dose of ferric ions increased from 1500 mg/l to 2000 mg/l, the COD removal efficiency after 2 hours electrolysis increases from 55% to 69% at 1 ml/min H 2 O 2 dose, from 76% to 84% at 1.2 ml/min H 2 O 2 dose and from 80.3% to 90% at 1.4 ml/min H 2 O 2 dose. The increase of initial ferric ions concentration and hydrogen peroxide continuous dosage was beneficial for the Fe 3+ - H 2 O 2 complexes formation (Eq. 1 and Eq. 2), which would be enhanced and consequently accelerated the formation of Fe 2+ and OH. Thus, organics degradation in the wastewater is enhanced. However, when initial ferric ions concentration and H 2 O 2 dosage further increased to 2300 mg/l Fe +3 ions and 1.6 ml/min H 2 O 2 dose, respectively, COD removal efficiency instead declined to 83.5%. This observation probably can be explained by the negative effects of the presence of large amount of ferric ions: 1) H 2 O 2 consumption by the Fenton-like reactions is also enhanced, resulting in lower utilization of H 2 O 2 ; 2) higher ferric ions concentration causes the presence of more ferrous ions, which may quench hydroxyl radicals (Eq.3), leading the COD removal efficiency of organics because of less available hydroxyl radicals, also COD removal decreased to 86% as the concentration of hydrogen peroxide increases at 1.6 ml/min, this is due to the side reaction between hydrogen peroxide and hydroxyl radical (Eq.4), this reaction result in the consumption of hydrogen peroxide as well hydroxyl radical and the production hydroperoxyl radical, a species with much weaker oxidizing power compared with hydroxyl radical, and these are consistent with previous research deals with degradation of phenol-containing wastewater using an improved Electro-Fenton processes[20]. Figure 3. Effect of different ferric ions concentration on the percentage of COD removal (ph =2, C. D =14.7 ma/cm 2, initial COD = 19000 mg/l, time = 120 min H 2O 2 dosage= 1.2 ml/min). Figure 4. Effect of different ferric ions concentration on the percentage of COD removal (ph =2, C. D =14.7 ma/cm 2, initial COD = 19000 mg/l, time = 120 min H 2O 2 dosage= 1.4 ml/min). Fe 3+ + H 2 O 2 Fe-OOH 2+ + H + (1) Fe-OOH + HO 2. + Fe 2+ (2) Fe 2+ + OH. Fe 3+ + OH - (3) H 2 O 2 + OH. HO 2. + H 2 O (4) Figure 5. Effect of different ferric ions concentration on the percentage of COD removal (ph =2, C. D =14.7 ma/cm 2, initial COD = 19000 mg/l, time = 120 min H 2O 2 dosage= 1.6 ml/min). 3.2. Effect of Initial Concentration of Waste Water Figure 2. Effect of different ferric ions concentration on the percentage of COD removal (ph =2, C. D =14.7 ma/cm 2, initial COD = 19000 mg/l, time = 120 min, H 2O 2 dosage= 1ml/min). The process for the removal efficiencies of COD of oxidation reaction at different initial concentrations of wastewater is illustrated in Figures below, four different initial concentration including 19000, 17000, 15000 and 13000 mg/l COD were tested with fixed current density and ph value of 14.7 ma/cm 2 and 2, respectively, the removal efficiency increased with decreasing initial COD concentration from 19000 mg/l COD to 13000 mg/l COD and increasing ferric ions concentration from 1500 mg/l Fe +3 to 2000 mg/l Fe +3 however, when initial ferric ions

4 Ahmed Mostafa Sadek et al.: Study on the Treatment of Effluents from Paint Industry by Modified Electro-Fenton Process concentration increased to 2300 mg/l, the COD removal percentage is decreased to 86, 86.5, 88 and 89% at 19000, 17000, 15000 and 13000 mg/l COD, respectively. This is due to the negative effects of the presence of large amount of ferric ions as discussed before in 3.1. Effect of ferric ions concentration. The maximum COD removal observed was 95.6% at initial concentration of wastewater 13000 mg/l COD, current density 14.7 ma/cm 2, ph value 2 and initial ferric ions concentration 2000 mg/l Fe +3. This effect has been previously discussed in a research deals with Removal of 17β-Estradiol by Electro-Fenton Process [21]. Figure 9. Effect of initial concentration of waste water on the percentage of COD removal (ph =2, C. D =14.7 ma/cm 2, H 2O 2 = 1.4 ml/min, time = 120 min, Fe +3 = 2300 mg/l). 3.3. Effect of Current Density Figure 6. Effect of initial concentration of waste water on the percentage of COD removal (ph =2, C. D =14.7 ma/cm 2, H 2O 2 = 1.4 ml/min, time = 120 min, Fe +3 = 1500 mg/l). Figure 7. Effect of initial concentration of waste water on the percentage of COD removal (ph =2, C. D =14.7 ma/cm 2, H 2O 2 = 1.4 ml/min, time = 120 min, Fe +3 = 1800 mg/l). One of the critical parameters in the EF-Fere processes is the electrical current which is responsible for the generation of ferrous ions within the electrochemical cell. Effect of electrical current on COD removal efficiency is shown in figures below at different initial concentration of wastewater. Experiments were applied to current density from 12.6 to 21 ma/cm 2 at constant ph, Fe +3 concentration and H 2 O 2 continuous dosage. Apparently, the COD removal efficiency goes up when applied current density increases from 12.6 to 19 ma/cm2, indicating an enhancement on the degradation capacity. At higher current, the electroregeneration of Fe 2+ is enhanced with the increasing of current, as a result, the efficiency of Fenton reactions and degradations of organics are improved. However, further increase of the electrical current density to higher than 19 ma/cm2, causes lower COD removal efficiency, as we can see from figures below. The maximum COD removal observed at 19 ma/cm 2 was 97, 95, 93.5, and 92.5% at initial concentration of wastewater 13000, 15000, 17000, and 19000 mg/l COD, respectively. The efficiency of E-Fenton will be less at higher current density 21 ma/cm 2, this is due to the competitive electrode reactions in electrolytic cell which are the evolution of oxygen at anode as shown in Eq. (5) and the evolution of hydrogen at cathode as shown in Eq. (6). These reactions reduce E-Fenton reaction efficiency. And these are consistent with previous research deals with degradation of phenolcontaining wastewater using an improved Electro-Fenton processes [20]. 2H 2 O 4H + + O 2 + 4e - (5) 2H + + 2e - H 2 (6) Figure 8. Effect of initial concentration of waste water on the percentage of COD removal (ph =2, C. D =14.7 ma/cm 2, H 2O 2 = 1.4 ml/min, time = 120 min, Fe +3 = 2000 mg/l). Also at higher current density COD removal decreased. This decrease in COD removal happens to the scavenging effect of ferrous ion eq. (5.7). In this reaction ferrous ions consume hydroxyl radicals. Fe 2+ + HO. OH - + Fe 3+ (7)

American Journal of Chemical Engineering 2016; 4(1): 1-8 5 3.4. Effect of UV on Organic Removal Figure 10. Effect of different current densities on the percentage of COD removal (ph =2, Fe +3 =2000 mg/l, H 2O 2 = 1.4 ml/min, time = 120 min, COD initial= 13000 mg/l). The optimal operation conditions of EF-Fere system were adopted for the comparison of EF-Fere and UV/EF-Fere process. Fig. 14 presents the degradation of organics in wastewater by these processes as a function of time. The 2 hours COD removal efficiencies with UV light are 99, 96.5, 95.5 and 94% at initial concentration of wastewater 13000, 15000, 17000 and 19000 mg/l COD, respectively. Irradiation of UV on EF-Fere process may have two aspects of effects. One is the direct destruction of organics due to the photolysis of organic molecules under UV, and another effect is the enhancement of OH by the following reactions eq. (8). Fe(lll)OH 2+ + hv Fe(ll) + OH. (8) Figure 11. Effect of different current densities on the percentage of COD removal (ph =2, Fe +3 =2000 mg/l, H 2O 2 = 1.4 ml/min, time = 120 min, COD initial= 15000 mg/l). Under the irradiation of UV light (254nm), ferric species can be reduced and hydroxyl radicals are produced for the organics oxidation process. In other words, in addition to the reactions proceeding in the EF-Fere process, the light irradiation can further catalyze the production of hydroxyl radicals and degrade the organics. Enhancing the Fenton process by UV light was discussed in a previous research has title of Enhancing the Fenton process by UV light applied in textile wastewater treatment [22]. Figure 12. Effect of different current densities on the percentage of COD removal (ph =2, Fe +3 =2000 mg/l, H 2O 2 = 1.4 ml/min, time = 120 min, COD initial= 17000 mg/l). Figure 13. Effect of different current densities on the percentage of COD removal (ph =2, Fe +3 =2000 mg/l, H 2O 2 = 1.4 ml/min, time = 120 min, COD initial= 19000 mg/l). Figure 14. Effect of UV on the percentage of COD removal (ph =2, Fe +3 =2000 mg/l, H 2O 2 = 1.4 ml/min, time = 120 min, C. D=19 ma/cm 2 ). 4. Electrical Energy Consumption and Electrode Consumption It is clear that a technically efficient process must also be feasible economically. The major operating cost of EF is associated with electrical energy consumption during process. According to the results presented energy consumption values ranged from 0.0046777 to 0.0097783 kwh/g COD removed and Pb consumption from 3.34795E- 07 to 5.83211E-07 g Pb / g COD removed at different current density, It can be concluded that the higher voltage of the system applied, the weight of the electrode consumed in the process has been increased and also the higher the concentration of the Fe 2+ in the solution which is responsible for H 2 O 2 activation. Also it is noticed that the most economic concentration of ferric ions is 2000 mg/l which achieves about 0.004784357 kwh/g COD (energy consumption) and

6 Ahmed Mostafa Sadek et al.: Study on the Treatment of Effluents from Paint Industry by Modified Electro-Fenton Process 2.74672E-07 g Pb/g COD removed (Pb consumption) because of the presence of more ferrous ions, which may quench hydroxyl radicals (Eq.3). Figure 15. Effect of ferric ions concentration on the energy consumption and Pb consumption (H2O2 =1.4 ml/min, Current = 1.75A, ph= 2, initial COD =19000 mg/l). Figure 16. Effect of initial concentration of waste water on the energy consumption and Pb consumption (H2O2 =1.4 ml/min, Current = 1.75A, ph= 2, Fe+3= 2000 mg/l). Figure 17. Effect of current density on the energy consumption and Pb consumption (H2O2 =1.4 ml/min, initial COD = 13000 mg/l, ph= 2, Fe+3= 2000 mg/l).

American Journal of Chemical Engineering 2016; 4(1): 1-8 7 Figure 18. Effect of UV on the energy consumption and Pb consumption (H 2O 2 =1.4 ml/min, current= 2.25 A, ph= 2, Fe +3 = 2000 mg/l). 5. Conclusion The COD removal of highly contaminated paint manufacturing wastewater has been studied. It has shown that modified Electro-Fenton method could effectively reduce COD of paint industry wastewater. We are able to remove about 97% of initial COD at initial ph=2, initial concentration of wastewater = 13000 mg/l COD, initial ferric ions concentration = 2000 mg/l, H 2 O 2 continuous dosage = 1.4 ml/min and current density = 19 ma/cm 2 after 120 min, while COD removal increased to about 99% with irradiation of UV light. The results show that Electro Fenton is an effective technology for COD reduction in industrial wastes with low capital cost. The application of Electro Fenton has received increase attention in the last decade to treat paint manufacturing wastewater. Overall, UV/EF-Fere process is promising technology for application in wastewater treatment. References [1] Dey, Hashim M, Hassan S (2004) Micro filtration of waterbased paint effluents, Adv. in Environ. Res. 8, p. 455-466. [2] Huang Y, Chang P, Chen C (2008) Comparative study of oxidation of dye-reactive Black B by different advanced oxidation processes. Jr. of Haz. Mat. 154, p. 655 662. [3] Torrades F, García-Hortal J, Domènech X (2002) Removal of organic contaminants in paper pulp treatment effluents under Fenton and photo-fenton conditions. Applied Catalysis B: Environmental 36 (1), p. 63 74. [4] Xia M, Long M, Yang Y, Chen C, Cai W, Zhou B (2011) a highly active bimetallic oxides catalyst supported on Alcontaining MCM-41 for Fenton oxidation of phenol solution, Appl. Catal. B: Environ. 110, p. 118-125. [5] Bremmer D, Burgess A, Houllemare D, Namkung K (2006) Appl. Catal. B: Environ. 63, pp. 15. [6] Zhang A, Wang N, Zhou J (2012) Heterogeneous Fenton-like catalytic removal of p-nitrophenol in water using acidactivated fly ash, J. Hazard. Mater. 201, p. 68. [7] Luis A, Miguel A, Antonio G (2011) Chem. Eng. J. 178, P. 146. [8] Ayodele O, Lim J, Hameed B (2012) Pillared montmorillonite supported ferric oxalate as heterogeneous photo-fenton catalyst for degradation of amoxicillin, Appl. Catal. A-Gen. 413, P. 301. [9] Youssef S, Ines W, Ridha A, Kinetic degradation of the pollutant guaiacol by dark Fenton and solar photo Fenton processes (2001), Environ. Sci. pollut. Res. 18, p. 1497. [10] Lypczynska-Kochany E (1993) Hydrogen peroxide mediated photodegradation of phenol as studied by a flash photolysis/hplc technique, Environ. Pollut. 80, P. 147 152. [11] Maciel R, Sant-Anna G, Dezotti M (2004) Phenol removal from high salinity effluents using Fenton's reagent and photo- Fenton reactions, Chemosphere, 57, P. 711. [12] Wang W, Kalck P, Faria J (2005) visible light photo degradation of phenol on MWCNT TiO 2 composite catalysts prepared by a modified sol-gel method Mol. Catal. A Chem., 235, P. 194. [13] Herrmann J (1999) Fundamentals and applications to the removal various types of aqueous pollutants, Catal. Today, 53, p. 115. [14] Boye B, Dieng M, Brillas E (2002) Degradation of herbicide 4-chlorophenoxyacetic acid by advanced electrochemical oxidation methods, Environ. Sci. Technol., 36, p. 3030. [15] Brillas E, Calpe J, Casado J (2000) Mineralization of 2, 4-D by advanced electrochemical oxidation, Water Res., 34, p. 2253. [16] Qiang Z, Chang J, Huang C (2002) Electrochemical generation of hydrogen peroxide from dissolved oxygen in acidic solution, Water Res., 36, P. 85. [17] Gozmen B, Oturan M, Oturan N (2003), Environ. Sci. Technol., 37, P. 3716. [18] Fernandes A, Morao A, Magrinho M, Lopes A, Goncalves I (2004) Electrochemical degradation of C. I. Acid orange 7, Dyes Pigments., 61, p. 287 296. [19] Clesceri L, Greenberg A, Andrew D (1998) Standard methods for the examination of water and wastewater. 20, p. 312.

8 Ahmed Mostafa Sadek et al.: Study on the Treatment of Effluents from Paint Industry by Modified Electro-Fenton Process [20] Li J, Xuhui M (2012) Degradation of Phenol-containing Wastewater Using an Improved Electro-Fenton Process, Int. J. Electrochem. Sci. 7, P. 4078 4088. [21] Naimi I, Bellakhal N (2012) Removal of 17β-Estradiol by Electro-Fenton Process, Materials Sciences and Applications, 3, P. 880-886. [22] Vasilica A, Igor C, Doina L, Constantin L, Ioannis P (2015) enhancing the fenton process by UV light applied in textile wastewater treatment., Environmental Engineering and Management Journal. 14, P. 595-600.