Assessment of Groundwater Resources in Kirana Hills Region, Rabwah, District Chiniot, Pakistan

Similar documents
Assessment of Groundwater Quality in and around Neyveli Lignite Mines using GIS and Water Quality Index, Cuddalore District, Tamil Nadu

Groundwater and Surface Water Overview of the Lochend Area, Alberta

Journal of Chemical and Pharmaceutical Research, 2012, 4(9): Research Article

WATER QUALITY INDEX USING GIS AND SUITABILITY FOR DRINKING PURPOSE IN AND AROUND BADVEL TALUKA OF KADAPA DISTRICT, ANDHRA PRADESH, INDIA

Water Quality Index For Assessment Of Water Quality In South Chennai Coastal Aquifer, Tamil Nadu, India

Spatial Distribution of Ground water Quality in Some Selected parts of Pune city, Maharashtra, India using GIS

pdfmachine trial version

Open Access. Heavy Metal Concentration in Groundwater of Kirana Hill Region, Rabwah, District Chiniot, Pakistan

Ground water aquifer properties of Sargodha City, Punjab, Pakistan

Analysis of Water Quality Index for Groundwater in Gudur Mandal, SPSR Nellore District - Integrated With RS And GIS

Quality Analysis of Ground Water in Cuddalore District Neyveli Block using Conventional Method

GROUNDWATER ASSESSMENT OF MAKKAH AL-MOKARAMA

Interpretive Guide & Summary Statistics

Helena Valley Ground Water Monitoring Program

Application of Statistical Analysis in Assessment of Seasonal and Temporal Variations in Groundwater Quality

Assessment of Ground Water Quality in and around Gobichettipalayam Town Erode District, Tamilnadu

INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCES Volume 2, No 2, Copyright 2010 All rights reserved Integrated Publishing Association

Journal of Chemical and Pharmaceutical Research

The effect of Hilti / Salahi Recharge Dam in Batineh Area, Sultanate of Oman on the Quality of Groundwater Using GIS

Assessment of Ground water Quality around Adayar River, Chennai, Tamil Nadu, India

12th Annual Louisiana Water Conference March 27-28, 2018

GEOCHEMICAL IDENTIFICATION OF SALINE WATER FROM AN IRRIGATION WELL IN NORTH-CENTRAL STAFFORD COUNTY, KANSAS

Analysis of Ground Water Quality Parameters around Kushmhi Railway Station Area

Evaluation of groundwater and surface water resources in quality and quantity at Binh Chanh district in Ho Chi Minh city, Vietnam

Salinity in the Central Valley

Department of Soil, Water and Environmental, University of Dhaka, Dhaka-1000, Bangladesh

Understanding Your Test Results

CHARACTERIZATION OF GROUNDWATER QUALITY AND SPATIAL VARIATION ANALYSIS OF KUNIGAL TALUK, USING GIS TOOLS PROJECT REFERENCE NO.

Environmental Science

Florida Aquifer Geology

Florida Aquifer Geology

Groundwater quality in Hungary a general view

12 ph. Figure 4. Cumulative plot of ph values from BMU 1. Table 4. Summary of ph values (standard ph units). SMCL: 6.5 to 8.5.

Qualitative Zoning of Groundwater Using GIS (Chemical Parameter of Acidity and Chloride), a Case Study: Sabili Plain

5. Basin Evaluation Salt and Nitrate Balance

Water Quality. CE 370 Lecture 1. Global Distribution of Earth s s Water

Florida Aquifer Geology

Chemical Properties of Groundwater in Bhiloda Taluka Region, North Gujarat, India

Assessment of Water Quality Index for the Groundwater in Tumkur Taluk, Karnataka State, India

ASSESSMENT OF UTILIZABLE GROUNDWATER RESOURCES IN A COASTAL SHALLOW AQUIFER

IMPACTS OF URBANIZATION OF THE GREATER CAIRO AREA ON THE GROUNDWATER IN THE UNDERLYING AQUIFER

A Physico Chemical Study of Ground Water from Few Selected Areas of Secunderabad in Telangana State

PHYSICO-CHEMICAL CHARACTERISTICS OF GROUNDWATER OF BHAVANI BLOCK, ERODE TAMILNADU, INDIA

1. Scaling. H.O.: H-5/21, KRISHNA NAGAR, DELHI Tel.: , Fax:

PHYSICO-CHEMICAL ANALYSIS OF GROUND WATER IN KASARI RIVER BASIN, KOLHAPUR DISTRICT, MAHARASHTRA, INDIA

Biological and Chemical Characteristics of Groundwater in a Rural Settlement Area of Davao Oriental

Journal of Chemical and Pharmaceutical Research

INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCES Volume 1, No1,2010

Urban Groundwater Scenario. M. S. Mohan Kumar. Department of Civil Engineering Indian Institute of Science Bangalore

Coachella Valley Regional Water Management Group (CVRWMG)

Assessment of Water Quality in Kalpakkam Region, Tamil Nadu

Assessment of ground water contamination in soil due to leachate migration from an open dumping site of Dharapuram Municipality, Tamilnadu, India

Assessement of Groundwater Quality for Irrigation in Hebbal Valley, Karnataka, India

Impact of the September 4, 2010 Canterbury Earthquake on Nitrogen and Chloride. Concentrations in Groundwater

WQI BASED GROUND WATER QUALITY ASSESMENT USING RS AND GIS

Qualitative Zoning of Groundwater Using GIS (Chemical Parameter of Electrical Conductivity and Total Dissolved Solids), a Case Study: Sabili Plain

Draft Fact Sheet Butte County Stable Isotope Recharge Study

Analysis of ground water quality of Jagdishpur industrial area of District C.S.M. Nagar (U.P.), India

CHAPTER 9 TABLE OF CONTENTS

Effect of irrigation on groundwater chemistry in the lower Chambal Command area, Madhya Pradesh, India

Chemical Parameter Analysis for Water, Waste Water and Ground Water

Annual Monitoring Report for Calendar Year 2009

International Journal of Scientific Research and Reviews

Groundwater and Well Water Education Program Waushara County - Eastern Towns Part of a study of Nitrate and Chloride in Waushara County

Variation of Groundwater Parameters through West to East Central Profile Section in Mubi Town, Northeastern Nigeria

Groundwater Suitability for Drinking and Agricultural usage in MIDC Area Chakan, Pune

HYDROCHEMISTRY AND MAPPING OF THE GROUNDWATER CONTAMINATION INDEX IN CHANGCHUN CITY, CHINA

Office of Land and Water Evaluations of Groundwater Resources of Southern Mississippi

Groundwater Replenishment with Purified Water Injection Provides Drought Protection & Environmental Benefits

Movement and Storage of Groundwater The Hydrosphere

QUALITATIVE ASSESSMENT OF GROUNDWATER IN SINGRAULI COALFIELD REGION, MADHYA PRADESH

PIT LAKES LIABILITY OR LEGACY? David Allen (MBS Environmental) Karen Ganza (MBS Environmental) Rob Garnham (Groundwater Resource Management)

Drinking Water Education

Florida Aquifer Geology

Paul Kirby, P.G. Daniel B. Stephens & Associates, Inc. with. Fayette County GCD Pecan Valley GCD. August 29, 2018

Hydrogeological Investigation and Analyzing Groundwater Scenario in Haringhata Block, West Bengal

Groundwater Forensics to Evaluate Molybdenum Concentrations Near a CCR Landfill

ANALYSIS AND MAPPING OF GROUND WATER QUALITY OF BHAUNAK RIVER BASIN OF JALGAON (MS) DISTRICT USING ARC-GIS

Journal of Chemical and Pharmaceutical Research, 2012, 4(3): Research Article

ASSESSMENT OF DRINKING GROUND WATER QUALITY AT MOGA, PUNJAB (INDIA) : AN OVERALL APPROACH

SALINAS VALLEY GROUNDWATER BASIN SETTING INITIAL REVIEW FOR DEVELOPMENT OF GROUNDWATER SUSTAINABILITY PLAN

TSUNAMI DISASTER AND GROUNDWATER RESOURCES: THE SOUTHEASTERN COAST OF INDIA. Bhanu Neupane Regional Hydrologist, UNESCO

A STATISTICAL ASSESSMENT OF GROUNDWATER QUALITY IN NILPHAMARI POURASHAVA, NILPHAMARI DISTRICT, BANGLADESH

Spatial Analysis of Groundwater Quality Using Geographic Information System A Case Study

Developing a Sustainable Ground Water Management Plan for Part of Ghaziabad District, Uttar Pradesh

Storage and Recovery of Rooftop Rainwater Runoff Using Drinking Water Wells

Chemical Analysis of Ground Waters in Tabriz Area, Northwestern Iran

REVIEW OF DEEP WAIRAU AQUIFER - GROUNDWATER CHEMISTRY ASPECTS. July 2008

University of Nairobi Department of Geology Presentation on, POLLUTION OF GROUNDWATER IN URBAN AREAS OF KENYA; FOCUSING NAIROBI CITY

ASSESSMENT OF GROUNDWATER QUALITY USING WQI METHOD AROUND VELLALORE MUNICIPAL SOLIDWASTE DISPOSAL SITE IN COIMBATORE, TAMILNADU, INDIA

The Effects of Water Table Decline on the Groundwater Quality in Aquifer of Torbat Jam Plain, Northeast Iran

Challenges for the sustainable management of urban water supply and sanitation systems Case of the Thiaroye aquifer

GIS APPLICATION IN GROUNDWATER QUALITY ESTIMATION

Irrigation. Branch. Groundwater Quality in the Battersea Drainage Basin

OPPORTUNITIES FOR FREE BASELINE WATER QUALITY TESTING

Geologic description of the Pocatello Aquifer

Local Water Supply and Salinity Impacts

Assessing Water Use and Availability Trends in New Hampshire

EVALUATION OF SURFACE DRINKING WATER SOURCES OF DEHRADUN USING MULTIVARIATE ANALYSIS

WHAT S IN YOUR WATER?

Transcription:

Open Access ISSN: 2223-957X Assessment of Groundwater Resources in Kirana Hills Region, Rabwah, District Chiniot, Pakistan Mirza Naseer Ahmad*, Rashida Sultana, Maria Salahuddin, Jaleed S. Ahmad Abdus Salam School of Sciences, Nusrat Jahan College, Rabwah, Pakistan. *Email: nmirza@njc.edu.pk Received: 26 August, 2016 Revised: 10 December, 2016 Abstract: This study was planned to assess the groundwater quality of the area adjacent to Precambrian Kirana Hills, Pakistan. The majority of the people in the area use groundwater from private wells for drinking and domestic use. Therefore, it is important to provide an overview of the groundwater quality. This information would be beneficial to local people and the administration for selecting suitable water treatment methods. Samples were collected from different wells of Rabwah town, close to the Kirana Hills. Parameters like EC, ph, alkalinity and total dissolved solids (TDS) were determined for 142 samples. While 40 samples were analyzed for hardness, Ca, Mg, Cl, SO 4, NO 3, and F. standards set by the World Health Organization (WHO) were considered to evaluate the quality of groundwater. Geographic Information System (GIS) was used to interpolate analyzed physicochemical parameters. The results showed that EC, TDS, hardness, Cl, SO 4, and Ca were very high in the water samples of the area. Fifty-two percent of samples had ph values lower than the permissible limits. Results suggest that the water quality is extremely adverse close to the hills. The poor water quality in the area near the hills may be due to the limited recharge of aquifers because of the hills and shallow basement, which may act as a barrier to subsurface water movement. Some physical and chemical parameters indicated that the quality of water at deeper levels (i.e. >150 ft) is relatively better. This may be due to limited exploitation of water from deeper aquifers as compared to shallow aquifers. Hence, proper aquifer management is required to prevent water quality deterioration due to over exploiataion. NO 3 was found within the acceptable limits and all water samples were found free of any significant contamination by human activities. Keywords: Kirana hills, GIS, water analysis. Introduction Groundwater is the only source of drinking water for many rural areas in developing countries. In many areas of developing countries, people are using groundwater without knowing its suitability for drinking and household purposes. In most of the cases, water quality is not within the safe limits. The groundwater can be contaminated due to natural processes or human activities. Drinking water quality management is the fundamental pillar in the control and prevention of waterborne diseases. Reduction in the number of people, who do not have access to safe drinking water has been enlisted as one of the targets of the Millennium Development Goals (MDGS) (WHO, 2001). Quality analysis of water sources in developing countries can help to achieve this objective. The purpose of this study was to evaluate and map the physicochemical characterization of groundwater in the area close to Precambrian rocks exposed in district Chiniot of Punjab province. These rocks are termed as Kirana Hills and comprise of a series of isolated bedrock hills exposed in the study area. This area totally relies on groundwater for drinking and domestic use. Mostly, local population draws water from private wells due to lack of adequate or no water supply by the local administration. No study has yet been conducted to assess the water quality in the area. Therefore, it was required to evaluate the suitability of groundwater from private wells for drinking and domestic use. Key physicochemical parameters were analyzed and mapped using Geographic Information System (GIS). These maps provide useful information for the local community and the government departments for planning safe and clean water supply. Study area This study was conducted in Rabwah town, Chiniot district of Punjab province (Figs. 1, 2). Precambrian rocks of the Kirana Hills are exposed in the northern part and the Chenab River borders the east of the town (Fig. 2). The Kirana Hills are one of the oldest rocks exposed in the plains of Punjab. These hills comprise of volcanics and meta-sedimentary rocks (Ahmad and Chaudary, 2009). In the area, Quaternary alluvium has been deposited on basement rock of Precambrian age (Greenman et al., 1968). Wells drilled close to outcrops penetrated bedrock at a shallow depth. The northwesterly alignment of the Kirana Hills indicates a trend of the bedrock ridge buried by the alluvium. The areas close to the hills and shallow basement comprise of fine sediments. Material and Methods Geographic locations of sampling sites were observed 54 SEGMITE

SO 4, Cl, NO 3, and F. Electric conductivity (EC) and ph were recorded by using conductivity and ph meters respectively. TDS was calculated by an evaporation method. Hardness, Ca, and Mg were analyzed by complexometric titration. Concentrations of SO 4, NO 3, and F were determined by the spectrophotometric method. The results were compared with standards set by the World Health Organization (WHO, 2008). GIS mapping ArcGIS software was used to plot sampling locations and to interpolate analyzed different parameters. Based on the data obtained from each location a map was prepared showing the positions of sampling sites (Figs. 2a, 2b). Analyzed results were imported as attributes of the point layer. Interpolation was performed by Inverse Distance Weight (IDW) method to generate spatial distribution maps of analyzed physical and chemical Fig. 1 Location of the study area. Fig. 2b Sampling locations for samples analyzed for Hardness Ca, Mg, Cl, SO 4, NO 3 and F. Fig. 2a Sampling locations for 142 samples analyzed for ph, EC, TDS and alkalinity. by GARMIN GPS receiver. The area is divided into eight administrative blocks. Samples were collected from all of these blocks. Procedures adopted for quality analysis and GIS mapping are discussed below. Physical and Chemical Analysis A total of 142 samples were collected from private water wells. The depth of these wells varied from 35 to 213 feet. Before sampling, pumps were allowed to run for 5 minutes. All 142 samples were analyzed for EC, ph, total dissolved solids (TDS) and alkalinity. We selected 40 samples for analysis of hardness, Ca, Mg, parameters. In IDW method, a weight was assigned to each point and the amount of weight was dependent on the distance of the point to another unknown point. The IDW derived the value of a variable at some locations using values obtained from a known location (Watson and Philip, 1985). Results and Discussion The results of different physicochemical parameters analyzed are given in Table 1. Electric conductivity (EC) in the groundwater samples of the study area is very high. Only 3% of the samples showed EC values less than the maximum permissible limit. Extremely high values of EC (i.e. > 7000 us/cm) were observed in the samples of Zone 7 and Zone 8 (Fig. 3). The 55

Table 1 Results of analyzed water quality parameters. Parameters No. of Standard WHO Fit % Min Max Average samples Deviation guidelines Samples ph 142 5.8 8.3 6.97 0.45 7 to 8.5 52 EC (us/cm) 142 420 19920 4584 3572 600 3 HCO3 mg/l 142 50 550 195 95 500 99.2 TDS mg/l 142 240 12160 2505 2059 500 9 Hardness mg/l 40 140 3700 827 636 500 32 Calcium mg/l 40 48 680 209 139 100 25 Magnesium mg/l 40 5 500 82 95 150 90 Chloride mg/l 40 90 8048 1241 1482 250 20 Sulfate mg/l 40 201.6 2131 884 258 250 2.5 Nitrate mg/l 40 1.66 8.89 4.24 2.75 50 100 Fluoride mg/l 40 0.029 0.074 0.047 0.009 1.5 100 maximum and minimum values of ph were 8.3 and 5.8 respectively. The average ph of water samples of the area was 6.97. Only 52% of the samples showed ph within the permissible limits of the WHO and the rest of the samples had ph values less than the lower recommended limit of 7 (Table 1, Fig. 5). Low ph may cause irritation to eyes, skin and has corrosive effect on fixtures (WHO, 2003). Carbonate alkalinity was not found in the samples tested. Hence, the total alkalinity was due to the presence of bicarbonate. All samples except one showed bicarbonate alkalinity within the permissible limit. High values of Total Dissolved Solids (TDS) were observed in samples obtained from wells close to the hills. However, samples from the western and eastern parts of the region had relatively lower values of TDS (Fig. 5). Hardness is one of the important parameters of water quality used for drinking and domestic uses. Only 13 samples (32%) showed values within the permissible limits (500 mg/l). Very high hardness (i.e. >1000 mg/l) was observed in samples from Zone 8 and western part of Zone 7 (Fig. 6). According to Bellizzi et al. (1999), hard water may produce urinary track calcium stone. The average value of Ca was 209 mg/l, which was higher than the permissible limits set by the WHO (100 mg/l). Most of the samples (75%) showed higher values of Ca than permissible limits. Whereas, ninety percent samples showed Mg values within the permissible limits (Table 1). High concentration of Cl was observed in water samples of the area. The average value of Cl in the samples was 1241 mg/l, which was far above the maximum permissible concentration of 250 mg/l. Interpolated GIS map showed high values throughout the area. However, extremely high values (i.e. > 4000mg/L) were observed in areas close to hills (Fig. 7). High chloride levels cause corrosion and shorten the life of pipes, pumps, hot water heaters and other such fixtures (Adeloju and Hughes, 1986). The average value of sulfate concentration was 884 mg/l, which was significantly higher than the WHO prescribed upper limit of 250 mg/l. Except for one, all samples showed higher values compared to WHO standards. IDW Fig. 3 IDW map of EC for 142 samples. Very high values were observed along the hills. Fig. 4 IDW map of ph values for 142 samples. Relatively low ph was observed in Zone 8, 7 and 5. 56

High values of EC, TDS, Cl, Ca, SO 4, and hardness were observed in water samples of the area. Some parameters were particularly high close to the hills. Water quality was relatively better in the western and eastern parts of the area. The possible recharge of aquifers in the area is through flooding and horizontal recharge by the Chenab River. The areas close to the hills are higher ground and thus rarely flooded, whereas eastern and western parts are sometimes flooded when the river overflows. Moreover, the area close to hills has fine sediments and shallow basement. The combination of relatively impermeable alluvium and the shallow bedrock may locally impede the movement of groundwater. Therefore, the rate of recharge is less than the rate of withdrawal and this makes the quality of water poor. Values of EC and Cl were relatively low at > 150 ft depth (Figs. 9, 11). The ph was also within the permissible limits at greater depths (>150 ft) (Fig. 10). Hence, deeper aquifers may Fig. 5 IDW map of TDS for 142 samples. Generally, high values of TDS were observed in the area. Fig. 7 IDW map of chloride. High values were observed in some parts of Zone 7, 8 and 6. Fig. 6 IDW map of hardness. Very high values were observed in Zone 8 and the western part of Zone 7. interpolated map showed higher values throughout the area (Fig. 8). High concentration of SO 4 in drinking water may have laxative effects on the digestive system of human beings (WHO, 2004). The presence of sulfate in drinking water also results in a noticeable change in the taste. Elevated sulfate levels can cause health concerns, when there is an abrupt change from drinking water with low sulfate concentration to drinking water with high sulfate concentration. The high concentration of sulfate may also contribute to the corrosion of water pumps and other equipment used to pump water out (WHO, 2004). Nitrate and Fluoride levels were within the permissible limits (Table 1). Fig. 8 IDW map of sulfate. High values were observed throughout the area. 57

Conclusions Fig. 9 EC and depth plot. Relatively low EC values were observed at greater depths (>150 feet). Fig. 10 ph and depth plot. At greater depths (>150), ph values were within the permissible limits. Fig. 11 Chloride and depth plot. Chloride concentration was inversely proportional to depth. X-axis is in logarithmic scale. The average values of EC, TDS, hardness, Ca, Cl, and SO 4 were extremely high in water samples of the area with respect to the permissible limits set by the WHO. More than 50% of the samples revealed lower ph values than the WHO prescribed limits. The poor water quality may have severe economic and health consequences on the local population. The groundwater of the area should be treated to remove excessive salts and neutralize the ph for drinking and domestic use. GIS maps of physicochemical parameters identify zones of poor quality groundwater. This information will help the local community and the administration to select an appropriate water treatment method. Spatial distribution maps of various parameters can assist to plan wells in future as well. References Adeloju, S. B., Hughes, H. C. (1986). The corrosion of copper pipes in high chloride-low carbonate mains water. Corrosion Science, 26, 851-870. Ahmad, S. A., Chaudary, M. N. (2009). Crystallization history of the Kirana Volcanics Sargodha. Geol. Bull. Punjab Univ., 44, 1-8. Bellizzi V., De Nicola L., Minutolo R., Russo D., Cianciaruso B., Andreucci M., Conte G. (1999). Effects of water hardness on urinary risk factors for kidney stones in patients with idiopathic nephrolithiasis. Nephron, 81, 66-70. Greenman, D. W., Swarzenski, W. V and Bennett, G. D. (1968). Groundwater Hydrology of the Punjab, West Pakistan With Emphasis on Problems Caused by Canal Irrigation. United States Geological Survey Water Supply Paper, 1608-H. Watson, D. F., Philip, G. M. (1985). A refinement of inverse distance weighted Interpolation. Geo- Processing, 2, 315-327. WHO, (2001). Water health and human rights. The World Water Day. (http://www.who.int/water_sanitation_health/humanrig hts/en/). WHO, (2003). ph in Drinking-water. WHO/SDE/ WHO/03.04/12. (http://www.who.int/water_sanitation_health/dwq/che micals/en/ph.pdf). WHO, (2004). Sulfate in Drinking-water. WHO/SDE/ WSH/03.04/114. WHO, (2008). Guidelines for drinking water quality, 3 rd ed. 1, Geneva. be a better source of water. However, extensive withdrawal of water from these aquifers may cause deterioration in water quality at this level. 58