June Residential Refurbishment Exposed soffit floors

Similar documents
Suspended timber upper floors

April Section 4.1. Ground Floors

June Non - Residential Refurbishment 5.5 Basements

June Residential Refurbishment Basements

August 2008: Issue 1. Non - Residential New Build 4.5 Basements

June Non - Residential Refurbishment Separating floors

June Non - Residential Refurbishment Internal lining walls

Polyfoam Floorboard For thermal insulation of floors

June Residential Refurbishment Separating floors

April Section 4.3. Separating Floors

4.1 Ground Floors. Ground floors. Ground floor design. Technical Support Team

June Residential New Build Timber Frame Walls

June Non - Residential New Build Partition walls

April Section Cladded Walls

June Residential Refurbishment Separating walls

June Residential New Build Render and cladding walls

April Section 5. Basements

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250

Jabfloor is also available in higher grades up to Jabfloor 250 which may be required in certain specialist industrial and commercial applications.

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100

Jabfloor High Performance (HP) 70 and 100

August 2008: Issue 1. Non - Residential New Build Built - up Metal Walls

August 2008: Issue 1. Non - Residential New Build Built-up Metal Roofs

December The Pocket Guide To Insulation

Jabfloor 70, 100, 150, 200, 250

August 2008: Issue 1. Non - Residential New Build Pitched Roofs - Ceiling Level

March The Pocket Guide To Insulation

April Section 2.4. Built-up Metal Roofs

May Danskin. Thermal Saddle System. Level, insulate and reduce air leakage and all with one flooring system. Danskin

Refurbishment site guidance for solid-walled houses ground floors

Flat roofs. Flat roof design. 2.3 Flat Roofs

APPLICATION: Floor insulation below chipboard finish

April Section 3.3. Built-up Metal Walls

Xtratherm Thin-R Underfloor Board (XT/UF Grade)

Jabfloor 70, 100, 150, 200, 250

April Section Internal Walls

Garage Conversion - Between and Under Joist Applications

ROCKFLOOR. Thermal and acoustic stone wool insulation for ground and separating floors

Thermal bridging. Acoustic performance

Superior Performance Phenolic Insulation SR/UF. Insulation for Ground Supported and Suspended Floors. Floors AS LOW AS 10/4803

How glass or rock mineral wool works in a wall or floor cavity

The Pocket Guide To Insulation May 2013

PIR Insulation. XT/UF Insulation for Ground Supported and Suspended Floors. Floors 08/ /0183

Light steel frame walls

Detail Sheet 1 / Ballytherm BTF Floor Insulation

Floors Walls Roofs. Jabfloor Premium board Jablite Premium board Jabfloor board Jablite board. APPLICATION: Basements PRODUCTS: Vencel Resil Limited

Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors

June Non - Residential Refurbishment Flat roofs

URSA TF Roll URSA GLASSWOOL.

Jabfloor 70, 100, 150, 200, 250

June Residential Refurbishment Flat roofs

Jabfloor 70 Floor insulation Suspended timber floor

Jabfloor High Performance (HP) 70 and 100

URSA ACOUSTIC ROLL URSA GLASSWOOL.

An introduction to Part L U-values

June Non - Residential New Build Masonry cavity walls

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

Basement Board High Performance (HP) 70 and 100

K3 Floorboard. Insulation INSULATION FOR FLOORS

Selecting floors and ceilings

Acoustic Cradle Levelling System

PRODUCT SHEET 1 KINGSPAN KOOLTHERM K3 FLOORBOARD

April Section Party Walls

Platinum. I n s u l a t i o n INSULATION FOR FLOORS. Low Energy Low Carbon Buildings

June Residential Refurbishment Masonry cavity walls

Built-up metal walls. Built-up metal wall design. 3.3 Built-up Metal Walls

April Section 2.5. Green Roofs

Eco-Versal. insulation. Polyisocyanurate (PIR) foam core with aluminium foil composite to both sides BASELINE TOPLINE SLIMLINE

Jabfloor 70, 100, 150, 200, 250

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

HP Partial Fill. Robust, long-lasting protection

Specialist products. Proven expertise. Acoustic flooring systems to meet the 2010 Scottish Standards - Section 5

FERMACELL DRY FLOORING ELEMENTS: IMPROVED LIVING CONDITIONS THROUGH BETTER ACOUSTIC AND THERMAL INSULATION. Dry Lining

June Residential New Build 2.0 Code For Sustainable Homes

August 2008: Issue 1. Non - Residential New Build Masonry Cavity Walls

robustdetails E-FC-6 Separating Floor Concrete Separating Floors Concrete E-FC-6 SYSTEM INSTALLATION

Stylite. T-Beam Suspended Floor Insulation Technical Datasheet. Stylite T-Beam Floor Insulation

RAINSCREEN DUO SLAB. Non-combustible thermal insulation

URSA MINERAL WOOL URSA Timber Frame Roll & URSA Timber Frame Slab

The Celotex Handy Guide

Why party wall insulation is required

K3 Floorboard. Insulation INSULATION FOR FLOORS

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

Part E robustdetails. robustdetails. September 2015 Update Pack. Dear Colleague,

THERMAL LAMINATES. for roofs, walls, floors and soffits

Dow Building Solutions Insulating floors with STYROFOAM Solutions: basic principles

Stylite. T-Beam Suspended Floor Insulation Technical Datasheet. Stylite T-Beam Floor Insulation.

roofing ROOFING Design of the base ROOFING DETAILS

K17 Insulated Plasterboard

PowerDeck F. PIR insulation for Warm Flat Roofs. Product Guide

Superior Performance Phenolic Insulation SR/PR. Insulation for Pitched Roofs. Roofs AS LOW AS 10/4803

Soffit Board. Insulation

PIR Insulation. XT/PR Insulation for Pitched Roofs. Roofs 08/ /0183

Dow Building Solutions. Insulating floors with STYROFOAM Solutions: basic principles

Your reference for Recticel PIR insulation.

Floors Walls Roofs. Jabfloor Premium Jabfloor. APPLICATION: Below ground supported slab PRODUCTS: Vencel Resil Limited

URSA Acoustic Roll Acoustic Insulation for Floors and Walls

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

Transcription:

June 2010 Residential Refurbishment 3.4.2 Exposed soffit floors

Residential refurbishment 3.0 Residential Refurbishment Exposed Soffit Floor Contents Introduction find online page Solution optimiser and pathfinder 288 Design considerations 290 Design Details 636 find online page Insulation below concrete soffit (Earthwool) Es01 636 Insulation below concrete soffit (Polyfoam) Es02 636 Insulation above concrete soffit Es03 638 Insulation between timber joists Es04/Es05 640

3.4.2 Residential refurbishment: Floors Exposed soffit Solution optimiser and pathfinder Certain building developments such as cluster homes and blocks of flats feature link units built above access ways or parking. It is important that any refurbishment work carried out on this type of floor includes the installation of the correct insulation in accordance with current Building Regulations. This applies also to dwellings with an integral garage or unheated porch. A key feature of installing insulation to existing exposed floors, is that refurbishment work can be completed quite easily without the need for access to areas above the floor, thus creating minimal disruption specifically designed for specialist exposed soffit applications. 288

Residential refurbishment: Floors 3.4.2 Max U-value for new thermal elements England and Wales, Scotland** and Northern Ireland Max U-value for replacement and upgraded thermal elements England and Wales, Scotland and Northern Ireland Exposed soffits Construction compatibility with Part L1B Elemental U-value requirement Knauf Insulation solution U values 0.32 0.31 0.30 0.29 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 0.20 0.19 0.18 0.17 0.16 0.15 0.14 0.13 Insulation below concrete soffit Product*: Earthwool Soffit Linerboard Extra Description: Compression resistant rock mineral wool insulation slab with impact resistant fibre cement facing, below concrete soffit Page No: 636 Es01 Insulation below concrete soffit Products*: Polyfoam Soffit Linerboard Description: Ultra strong XPS insulation board with impact resistant fibre cement facing, below concrete soffit Page No: 636 Es02 Insulation above concrete floor Products*: Polyfoam Floorboard Standard Description: Ultra strong XPS insulation above concrete floor with exposed soffit Page No: 638 Es03 Insulation between timber joists Product*: Earthwool Loft Roll 44 or Earthwool Flexible Slab Description: Glasswool or rock mineral wool insulation between timber joists of exposed soffit floor Page No: 640 Es04 Es05 Key U values achievable by constructions within this document. * Recommended Knauf Insulation product(s). Other products may be applicable. Pb01 Find online. Visit www.knaufinsulation.co.uk and key in construction code to find the most up to date information on your chosen solution. ** Also max U-value for replacement and upgraded thermal elements 289

3.4.2 Residential refurbishment: Floors Exposed soffit floors Exposed soffit design Many clients perceive that rooms above exposed upper floors will be cold. However, it is possible to achieve very high levels of thermal insulation in both new build and refurbished exposed upper floors. The designer has a choice of where to position the insulation: for concrete floors, either above or below the floor, or for timber joisted floors, between the joists. If insulating below the structural floor, the insulation can be laminated to a robust construction board that will provide a finish to the soffit. This method allows for insulation and cladding in one process. Insulating above the structural floor reduces the thermal mass of the floor allowing for fast warm up times. However, if only part of the floor on that storey is exposed it may cause problems with steps between finished floor levels. When insulating between timber joists, the whole depth of the joist can be utilised as an insulation zone. If mineral wool insulation is installed between the joists, a very high insulation value can be achieved without increasing the depth of the floor construction or adding significant weight to the structure. Shelter factors Where an exposed floor is over an enclosed but unheated space, such as an integral garage in a dwelling, the shelter factor of the garage improves the U-value of the exposed floor. BRE publication BR443 Conventions for U-value Calculations, sets out the shelter factors to be applied to separating walls in these locations. There are specific additional requirements that need to be taken into to consideration when calculating the U-values for elements that are adjacent to unheated spaces. The U-value of an exposed floor (soffit) which separates a heated area from an unheated area can be calculated by including an additional amount of thermal resistance (R u ) due to the sheltering effect of the unheated area. For instance 0.33m 2 K/W (R u ) can be added into a U-value calculation for an exposed floor (soffit) above a garage. A simple formula can then be used to calculate the U-value incorporating the inclusion of R u as follows: U = 1 (1/R o ) + R u Where: U = U-value with shelter factor included U o = U-value of the element between the heated and unheated spaces and calculated as if there were no unheated space adjacent to the element R u = additional thermal resistance due to shelter factor Thus: 1 = 3.19m 2 K/W (1/0.35) + 0.33 and: 1 = 0.31 W/m 2 K 3.19m 2 K/W Standard default values of Ru can be taken from BR443 (Conventions for U-value Calculations) or SAP 2005. For situations not covered by default values, or where additional guidance is required contact our Technical Advisory Centre on 01744 766666. Positions for floor insulation 1) Insulation below concrete floor 2) Insulation above precast concrete slab Screed or chipboard finish Vapour control/slip layer Screed finish Polyfoam Floorboard Concrete floor Precast concrete floor Earthwool Soffit Linerboard Extra or Polyfoam Soffit Linerboard Ceiling 290

Residential refurbishment: Floors 3.4.2 Concrete upper floors Insulation can be positioned above or below the concrete floor. When above the floor, the insulation is usually located below a floating screed or chipboard deck. If only part of a concrete slab is insulated, careful detailing may be needed to avoid steps in the floor level. Insulation located below the floor should be covered, usually with plasterboard or other fire resistant board. Externally a weather and impact resistant board should be used. Suspended timber upper floors In timber joisted floors, the insulation is usually located between the joists. A vapour control layer is not usually included because of the risk of trapping water spillages. Care is needed to minimise air leakage. The floor perimeter should be sealed by applying expanded foam tape under the skirting and a continuous bead of sealant to the back of the skirting prior to fixing. The perimeter of the ceiling should also be sealed with a flexible sealant. Gluing the joints between the floor deck panels will also reduce potential airpaths. Heated floors When the floor is to be heated by hot water pipes or electrical cables then the position of the insulation will be determined by whether the floor slab or the screed is to be heated. If the screed only is to be heated then the insulation is laid between the structural slab and the screed. Use either Polyfoam Underfloor Heating Board or a pre channelled board as used in the Osma underfloor heating system. Compressive strength All materials are compressed under load. Insulation materials used below screeds and floating chipboard decks should be capable of accommodating the applied loads with the minimum of compression. The applied load has two components: The dead load, which is due to the weight of the materials laid on the insulant, and The design load. BS 6399: 1996 outlines guideline figures for expected design loads in uniformly distributed loads (UDL) for various non-domestic and some industrial applications. However, in a sector where future use is potentially unknown and point loads can be large, the engineer is often required to assess the service needs of the floor on a project by project basis. Weather resistance The soffits of exposed floors should be finished with a weather resistant finish. Although not exposed to direct driving rain, wind turbulence can result in wind-driven drain being blown up onto soffits. Another consideration is that soffits, being sheltered from washing effect of driven rain, tend to collect dirt and grime over time. A smooth, impermeable finish will attract less dirt and be easier to keep clean. Fire resistance The fire resistance of the exposed floor should comply with Building Regulation requirements. This will be between 30 and 120 minutes, depending on the purpose group of the building and the height above ground. Approved Document B does not refer to the surface spread of flame requirements for exposed floors. Knauf Insulation recommend that the soffit has a Class 1 surface spread of flame to BS 476: Part 7: 1987. British Standards Designers should consult BS EN 312 Parts 1-7 when selecting chipboard or other floor decking boards. 3) Insulated timber floor Floor deck Earthwool Loft Roll 40/44 between joists Minimum 35mm Earthwool Loft Roll 40/44 Ceiling Ceilingdesign detail finder Knauf Insulation solutions for these types of construction can be found ±on pages 636-641 291

6.3.2 Design details: Exposed soffit Exposed soffit Insulation below concrete soffit Advantages 3 Insulation located below exposed floors, maximising room height/volume 3 Suitable for refurbishment Es01 Es02 3 Work can be completed without need for access to areas above the floor 3 Aesthetic finish with other facing options available on application Polyfoam Soffit Linerboard 3 Moisture resistant solution 3 Lightweight option Earthwool Soffit Linerboard Extra 3 Fully non-combustible with highest Euroclass A1 fire resistance Zero ODP and Zero GWP Product Wall insulation taken down at least 300mm below top of soffit insulation Polyfoam Soffit Linerboard or Earthwool Soffit Linerboard Extra Floor screed Concrete slab Products Polyfoam Soffit Linerboard is a laminate of Polyfoam, 100% ozone friendly, extruded polystyrene, rigid board insulation and a tough, weather resistant fibre reinforced cement facing board Earthwool Soffit Linerboard Extra is a laminate of non-combustible rock mineral wool slab and a tough, weather resistant fibre reinforced cement facing board Earthwool Soffit Linerboard Standard is a noncombustible rock mineral wool slab with a black tissue facing. Its manufacture has a very low impact on the environment and is classified as Zero ODP and Zero GWP* * EcoHomes and Code for Sustainable Homes classification Typical construction A concrete upper floor slab or beam and block floor insulated on the underside with either Polyfoam Soffit Linerboard or Earthwool Soffit Linerboard Standard/Extra. The Linerboards can either be screw fixed directly to the slab, or to timber battens either fixed directly to the soffit or nailed to ceiling clips held within the joints of prestressed concrete units. Polyfoam Soffit Linerboard and Earthwool Soffit Linerboard Extra have integral 6mm reinforced cement facing boards. Earthwool Soffit Linerboard Standard has a black tissue facing. Installation Fixing directly to soffit Ensure the structure is stable and suitable to support the extra load of the lining boards. If in doubt, seek specialist advice. Polyfoam Soffit Linerboard or Earthwool Soffit Linerboard Extra is screwed to the structure using suitable fixings, set in at least 50mm from any board edge. All boards to be butt jointed. There are a wide range of fixings available from suppliers such as Hilti, Ejot and Fischer. Typical fixings per board are 4 fixings for Earthwool Soffit Linerboard Extra and 8 for the larger Polyfoam Soffit Linerboard. However, due to variations in the specification of concrete, Knauf Insulation advise you seek specialist advice from the fixing manufacturer. Where board edges are exposed, ensure insulation is covered with either a cement board or a suitable flashing, cutting in where required. Use a flexible and fire resistant sealant to seal any imperfection of fit at board joints and junctions of boards and walls. Fixing to timber battens Fix treated timber battens at max 400mm centres using fixings suitable for the substrate. When fixing battens below prestressed concrete units (whether planks or beams), always consult specialist fixing manufacturers for further advice. Polyfoam Soffit Linerboard or Earthwool Soffit Linerboard Extra is screwed to the timbers at maximum 400mm centres along the length of the battens, fixing to each timber, using suitable fixings (set in at least 50mm from any board edge) that penetrate more than 40mm beyond the back of the board. All boards to be butt jointed. Where board edges are exposed, ensure insulation is covered with either a cement board or a suitable flashing, cutting in where required. Use a flexible and fire resistant sealant to seal any imperfection of fit at board joints and junction of board and wall. 636

Design details: Exposed soffit 6.3.2 Typical wall/floor junction Earthwool Soffit Linerboard Flexible seal between skirting board and screed Continuous ribbon of plasterboard adhesive Earthwool Soffit Linerboard Extra Typical specification Polyfoam Soffit Linerboard* thickness... or Earthwool Soffit Linerboard Standard*/ Extra* thickness... to be screwed to the structural soffit using... fixings manufactured by... Fixings to be set in at least 50mm from any board edge. Boards to be butt jointed and sealed with... sealant manufactured by... (* delete as appropriate) Alternatively, refer to NBS clause. Minimum 300mm overlap between wall and soffit insulation to minimise thermal bridging Flexible and fire resistant sealant at board joints/perimeters to minimise air leakage Performance Thermal performance Table 77 gives the thermal resistance of each thickness of product. Table 78 gives typical U-values. Fire performance Both Polyfoam Soffit Linerboard and Earthwool Soffit Linerboard Extra are faced with a 6mm fibre reinforced cement board which is classified as Class 1 surface spread of flame to BS 476: Part 7: 1987. Polyfoam insulation contains a flame retardant to inhibit localised ignition. Earthwool rock mineral wool is classified as Euroclass A1 to BS EN ISO 13501-1. Moisture resistance Polyfoam is highly resistant to moisture absorption and can be installed in damp areas or during periods when moisture levels are high with negligible impact on the performance of the product. The facing material is moisture resistant. Facing boards Whilst a standard solution is offered, a choice of colour or other aesthetic options can be manufactured on request. Table 77: Thermal performance and product weights Board type Thickness (mm) Thermal resistance Weight kg/m 2 m 2 K/W (kg/m 2 ) Polyfoam Soffit 127/6 4.25 9.5 Linerboard 108/6 3.60 9.0 Earthwool Soffit 165/6 4.45 15.6 Linerboard Extra 130/6 3.50 13.6 Earthwool Soffit 165 4.45 9.5 Linerboard Standard 130 3.50 7.5 Table 78: Typical U-Values of upper concrete floor with 50mm screed finish Es02 Es01 Insulation U-Value (W/m 2 K) Thickness Beam and block Precast plank Cast slabs (mm) Dense Medium Lightweight Aircrete 150mm 200mm Polyfoam Soffit Linerboard 127/6 0.22 0.22 0.21 0.21 0.22 0.22 108/6 0.25 0.25 0.25 0.23 0.25 0.25 Earthwool Soffit Linerboard Extra 165/6 0.20 0.20 0.20 0.19 0.20 0.20 130/6 0.25 0.25 0.25 0.24 0.25 0.25 Note: The U-Values have been calculated to BS EN ISO 6946: 1997. There are specific additional requirements that need to be taken into to consideration when calculating the U-values for elements that are adjacent to unheated spaces. The U-value of an exposed floor (soffit) which separates a heated area from an unheated area can be calculated by including an additional amount of thermal resistance (R u ) due to the sheltering effect of the unheated area. Standard default values of R u can be taken from BR443 (Conventions for U-value Calculations) or SAP 2005. For situations not covered by default values, or where additional guidance is required contact our Technical Advisory Centre on 01744 766666. 637

6.3.2 Design details: Exposed soffit Exposed soffit Insulation above concrete soffit Advantages 3 Compression resistant, supporting screed under high point loads 3 Provides excellent thermal performance in limited insulation zone 3 Structural and thermal solution 3 Robust and can tolerate traffic from following trades without damage prior to floor finish being laid. 3 Can support machinery required for pumped screeding applications 3 Ideal for underfloor heating solutions Es03 Polyfoam Floorboard 25mm Polyfoam Floorboard Vapour control layer Concrete precast floor Levelling screed (where required) Polyfoam Floorboard 75mm sand/cement screed Products Polyfoam Floorboard is a range of 100% ozone friendly extruded polystyrene rigid board insulation it is lightweight yet has excellent structural strength and long term effectiveness. It is available in two grades suitable for this application: Standard domestic and light commercial loading Extra commercial, industrial flooring and cold storage Typical construction A suspended precast concrete floor overlaid with Polyfoam Floorboard and finished with either flooring grade chipboard or a floating screed of either sand:cement or a proprietary liquid screed. Where a screed is used, a strip of Polyfoam Floorboard insulation, minimum 25mm thick, should be placed vertically at the perimeter of the screed to minimise thermal bridging. A vapour control layer should be placed between the insulation and the screed. This method of insulating an upper floor is suitable for all types of concrete floor, including, beam and block, cast in-situ and concrete cast on metal profile shuttering. Installation The surface of any floor should be smooth and flat to within 5mm when measured with a 2 metre straight-edge. Provided the surface is smooth and flat, the insulation may be laid directly onto the flooring system. Otherwise, lay a thin levelling screed prior to laying the insulation. Irregularities greater than those detailed above must be removed. Where a precast floor has a camber or uneven upper surface a levelling screed is recommended. Screeded finish Place a minimum 25mm thick vertical piece of Polyfoam Floorboard to the full depth of the screed around the perimeter of each room to minimise thermal bridging. Ensure these perimeter insulation boards are securely held in place to prevent dislodgement by following trades. Lay the vapour control layer over the insulation and turn up at the junction with the walls. Lay a sand/cement or proprietary screed as specified. If a sand/cement screed is used, it is important to ensure it is well compacted in order to produce a durable floor surface. Chipboard finish The insulation should be laid with staggered, tightly butted joints over the whole of the concrete floor. Lay the chipboard in a staggered pattern with all joints glued using a waterproof PVA adhesive. Leave an expansion gap of at least 10mm or 2mm per metre run of floor at the room perimeter. At doorways or access traps to pipework runs, support the cut edges of chipboard on preservative treated battens. No battens are required in the main area of the floor. This solution is also suitable for use with Polyfoam Underfloor Heating Board and the Osma Underfloor Heating System see pages 624 and 625. 638

Design details: Exposed soffit 6.3.2 Typical wall/floor junction Flexible seal between skirting board and screed Minimum 150mm overlap between wall and floor insulation to minimise thermal bridging Vapour control layer Polyfoam Floorboard Typical specification Insulation below screed Polyfoam Floorboard Standard*/Extra...mm thick, to be closely butted and placed over the whole area of the concrete floor. Polyfoam Floorboard, minimum 25mm thick, to be cut and placed to full depth of screed at the floor perimeter. The insulation to be overlaid with 1000 gauge polythene, taken up and over the perimeter insulation. A 75mm thick sand/cement screed with wire mesh*/ polypropylene reinforcing fibres* to be laid on top. Floor finish as specified by the designer. Alternatively install a proprietary liquid screed (minimum thickness 35mm) laid in accordance with manufacturers instructions. (* delete as appropriate) Alternatively, refer to NBS clause: M10/40 or M10/290 Cavity tray Levelling screed (where required) Insulation below chipboard Polyfoam Floorboard Standard*/Extra... mm thick, to be closely butted and placed over the whole area of the concrete floor. The insulation to be (overlaid with a vapour control layer of 1000g polythene and)* covered with 18mm t&g flooring grade chipboard. (*delete as required) Alternatively, refer to NBS clause: K11/25 or K11/225 Performance Thermal performance The thermal conductivities of Polyfoam Standard 0.029W/mK Extra 0.029-0.034 W/mK Unlike most other insulants, the effect of moisture on performance is negligible. Table 80 details U-values for a range of concrete floors with exposed soffits. Fire performance When Polyfoam Floorboard is installed in a floor construction it will not contribute to the development stages of a fire. Compression resistance Polyfoam Floorboard is highly resistant to compression see Table 79. Table 79: Compressive creep results for Polyfoam Floorboards Product Load applied (kpa) Initial compression (%) Further compression after 50 years (%) Polyfoam Standard 60 2 1.5 Polyfoam Extra 120 2 1.5 Table 80: Typical U-values of concrete suspended above ground floors U-Value (W/m 2 K) Insulation thickness Beam and block Precast plank Cast slabs (mm) Dense Medium Lightweight Aircrete 150mm 200mm Polyfoam Floorboard under screed (75mm) 130 (65+65) 0.20 0.20 0.19 0.19 0.20 0.20 125 (75+50) 0.21 0.21 0.20 0.19 0.20 0.21 110 (75+35) 0.24 0.23 0.22 0.21 0.23 0.23 100 (50+50) 0.26 0.25 0.24 0.23 0.25 0.25 Polyfoam Floorboard under chipboard 130 (65+65) 0.20 0.20 0.19 0.18 0.20 0.20 125 (75+50) 0.21 0.21 0.19 0.19 0.20 0.21 110 (75+35) 0.24 0.23 0.22 0.21 0.23 0.23 100 (50+50) 0.26 0.25 0.23 0.23 0.24 0.25 Notes: The U-values have been calculated to BS EN ISO 6946:1997. There are specific additional requirements that need to be taken into to consideration when calculating the U-values for elements that are adjacent to unheated spaces. The U-value of an exposed floor (soffit) which separates a heated area from an unheated area can be calculated by including an additional amount of thermal resistance (R u ) due to the sheltering effect of the unheated area. Standard default values of R u can be taken from BR443 (Conventions for U-value Calculations) or SAP 2005. For situations not covered by default values, or where additional guidance is required contact our Technical Advisory Centre on 01744 766666. 639

6.3.2 Design details: Exposed soffit Exposed soffit Insulation between timber joists Advantages 3 Insulation friction fits to the sides of the joists 3 Low cost solution 3 Fast and simple solution 3 Utilises non-combustible, firesafe insulation throughout Es04 Es05 3 Earthwool Loft Roll 44 and Earthwool Flexible Slab are both Zero ODP and GWP insulation products 3 The manufacture of Earthwool Loft Roll 44 and Earthwool Flexible Slab have a very low impact on the environment Flexible seal below skirting board and floor 35mm Earthwool Loft Roll 44 or 35mm Earthwool Flexible Slab Earthwool Loft Roll 44 or Earthwool Flexible Slab Products Earthwool Loft Roll 44 is made from glass mineral wool and formed into rolls which are lightweight, flexible, resilient and noncombustible, Its manufacture has a very low impact on the environment and is classified as Zero ODP and Zero GWP* Earthwool Flexible Slab is a multi purpose, rock mineral wool flexible slab designed for friction fitting in a range of acoustic, thermal and fire resisting applications. Its manufacture has a very low impact on the environment and is classified as Zero ODP and Zero GWP* * EcoHomes and Code for Sustainable Homes classification Typical construction A timber joisted floor finished with 22mm tongue and groove flooring grade chipboard or similar decking, the underside finished with either 12.5mm plasterboard, 6mm calcium silicate board or similar. Earthwool Loft Roll 44 or Earthwool Flexible Slab is laid between the joists to fully fill the void. Installation Install the floor joists so that any joists running parallel with masonry walls have a minimum gap of 35mm between themselves and the wall to allow the insertion of insulation. Install the ceiling. Seal the joint between the ceiling and the surrounding walls with a flexible sealant, to prevent air leakage. Simply friction fit the Earthwool Loft Roll 44 to fill the space between the joists. Alternatively, cut slabs of Earthwool Flexible Slab to fit between the joists. The insulation should rest on the ceiling. Between the last joist and the wall, cut insulation to size and install in the gap. Screw fix the chipboard deck to the timber joists as normal, using waterproof PVA glue at the joints, and allow a minimum gap of 10mm at the room perimeter. When fixing the skirting board, apply a selfadhesive foam strip to the underside of the skirting and two beads of sealant to the back surface. Apply pressure to ensure the foam strip is compressed immediately before fixing the skirting in place. 640

Design details: Exposed soffit 6.3.2 Typical wall/floor junction Flexible sealant between skirting board and floor Continuous ribbon of plasterboard adhesive Gaps below 25mm wide fill with expanding foam, otherwise pack with mineral wool Earthwool Loft Roll 44 or Earthwool Flexible Slab Typical specification Earthwool Loft Roll 44*/Earthwool Flexible Slab*...mm thick, supported on the ceiling to friction fit tightly between the joists. Earthwool Loft Roll 44*/ Earthwool Flexible Slab* to be cut to fully fill the gap between the last joist and the perimeter wall. (* delete as appropriate) T&g flooring grade chipboard to be screwed to the floor joists, all as specified by the designer. Alternatively, refer to NBS clause: P10/240 or P10/250 Minimum 150mm overlap between wall and soffit insulation to minimise thermal bridging Flexible and fire resistant sealant at board joints to minimise air leakage Performance Thermal performance Earthwool Loft Roll 44 has a thermal conductivity of 0.044 W/mK. Earthwool Flexible Slab has a thermal conductivity of 0.035 or 0.037 W/mK. Table 81 details U-values for this construction. Fire performance Earthwool Loft Roll 44 and Earthwool Flexible Slab are classified as Euroclass A1 to BS EN ISO 13501-1. Table 81: Typical U-values of suspended timber upper floor U-values (W/m 2 K) Es04 Thickness (mm) *0.33 1 0.25 2 0.26 3 4 No R u Earthwool Loft Roll 44 300 (2x150) 0.15 0.15 0.15 0.16 250 (100+150) 0.17 0.18 0.18 0.19 200 0.21 0.21 0.21 0.23 150 0.27 0.27 0.27 0.29 U-values (W/m 2 K) Es05 Thickness (mm) *0.33 1 0.25 2 0.26 3 4 No R u Earthwool Flexible Slab 300 (3x100) 0.13 0.13 0.13 0.13 250 (2x100+50) 0.15 0.15 0.15 0.16 200 (2x100) 0.18 0.18 0.18 0.19 150 (2x75) 0.23 0.23 0.23 0.25 8% timber bridge with 12.50mm plasterboard ceiling Notes: The U-values have been calculated to BS EN ISO 6946:1997 and assume joists are 48mm wide, spaced at 600mm centres and are the same depth as the insulation. * Additional thermal resistances for shelter effect of enclosed unheated spaces R u (m 2 K/W) 1 0.33, 2 0.25, 3 0.26, 4 no R u. There are specific additional requirements that need to be taken into to consideration when calculating the U-values for elements that are adjacent to unheated spaces. The U-value of elements between the dwelling and an integral garage should be adjusted using Ru from Table A1 or A2 of BR443. An additional amount of thermal resistance (Ru) can be included in U-value calculations, the amount of additional thermal resistance is dependent (in part) on whether or not the insulated walls wrap around the integral garage, or separate the dwelling from the garage space. Standard default values can be taken from BR443 (Conventions for U-value Calculations) or SAP 2005. For situations not covered by default values or where additional guidance is required contact our Technical Advisory Centre on 01744 766666. 641

Knauf Insulation Ltd PO Box 10 Stafford Road St Helens Merseyside WA10 3NS UK Tel: 01744 766 600 Fax: 01744 766 750 www.knaufinsulation.co.uk Ref: KB142510 June 2010 Knauf Insulation Ltd Customer Service (Sales) Technical Advisory Centre Literature PO Box 10 Tel: 0844 800 0135 Tel: 01744 766 666 Tel: 08700 668 660 Stafford Road Fax: 01744 612007 Fax: 01744 766 667 Fax: 0870 400 5797 St Helens Email: sales@knaufinsulation.com Email: tech@knaufinsulation.com Email: info@knaufinsulation.com Merseyside www.knaufinsulation.co.uk WA10 3NS