Effects of TiO2 Contents on HA/TiO2 Composite Coating by Electrophoretic Deposition Lei Zhao, Huiping Shaoa, Hang Zheng

Similar documents
Fabrication and characterization of HAp /Al 2 O 3 composite cating on titanium substrate

Hydroxyapatite/Titania coating on titanium strip by brush coating

Development of a Co-Cr-Mo to Tantalum Transition using LENS for Orthopedic Applications

Characterization of Oxide Film Formed on Ck45 Steel by Plasma Electrolytic Oxidation Method

Surface Construction Of Zn Doped Hydroxyapatite/mgf2 Multilayer Coatings For The Biomedical Mg Materials By A Novel Conversion/sol-gel Method

The Influence of Oxidized Interlayer on the Adhesion of Bioactive Cao-P2o5-Tio2-Na2o Glass Ceramic Coating to the Titanium Substrate

PREPARATION AND CHARACTERIZATION OF HYDROXYAPATITE FROM FISHBONE

STUDY ON HYDROXYAPATITE COATING ON BIOMATERIALS BY PLASMA SPRAY METHOD

BIOACTIVE SILICIUM-CONTAINING COATINGS ON TITANIUM SUBSTRATE

CoatingImplants. ResearchEngineer OrchidOrthopedicSolutions

FABRICATION OF 316L STAINLESS STEEL FOAMS VIA POWDER METALLURGY TECHNIQUE

CHAPTER 8 CONCLUSIONS AND SUGGESTIONS FOR FUTURE WORK

The advantages and use of ceramics in medicine

A STUDY ON NANOCOMPOSITE HYDROXYAPATITE COATINGS ON TI6AL4V FABRICATED BY ELECTROPHORETIC DEPOSITION AND LASER SURFACE TREATMENT.

POWDER METALLURGY PREPARATION OF POROUS TITANIUM FOR MEDICAL IMPLANTS. Pavel NOVÁK, Ladislav SITA, Anna KNAISLOVÁ, Dalibor VOJTĚCH

Direct nano-crystalline Ni plating on titanium surfaces

Additive Manufacturing of Hard Biomaterials

Laser assisted Cold Spray

CHAPTER I INTRODUCTION

1. Introduction Over the past decades, one of the most investigated bioceramics for bone substitution is hydroxyapatite (Ca 10

Electrophoretic deposition and reaction-bond sintering of Al 2 O 3 /Ti composite coating: evaluation of microstructure, phase and wear resistance

Fabrication of 316L Stainless Steel Foams via Powder Metallurgy Technique

Past, Present and Future of the Republic Center for Structure Researches of Georgian Technical University

SILICA AND TITANIUM OXIDE THIN FILMS FOR MEDICAL IMPLANTS

Fabrication of CaO Insulator Coatings by MOCVD for Application in Fusion Reactor Blankets*

Microstructure and Mechanical Properties of HA/ZrO2 Coatings by Gas Tunnel Plasma Spraying.

Ceramics, Glasses, and Glass-Ceramics

Department of Chemical Engineering, Riau University, Pekanbaru, Indonesia.

Preparation of PZT(53/47) thick films deposited by a dip-coating process

Fabrication and thermal properties of Al 2 TiO 5 /Al 2 O 3 composites

Development and Study on Various Properties of Titanium Oxide -Tri Calcium Phosphate Composites through Powder Metallurgy Technique

TRIBOLOGICAL PROPERTIES OF SOLID LUBRICANT NANOCOMPOSITE COATINGS OBTAINED BY MAGNETRON SPUTTERED OF MOS 2 /METAL (TI, MO) NANOPARTICLES

Preparation and Properties of High Chromium Cast Iron Matrix Composites Reinforced by Zirconium Corundum Particles

Thermal Conductivity and Sintering Behavior of Hafnia-based Thermal Barrier Coating Using EB-PVD

Surface Coating of Tungsten Carbide by Electric Exploding of Contact

Influence of TiC on the Viscosity of CaO MgO Al 2 O 3 SiO 2 TiC Suspension System

Preparation and properties of PTFE anti-friction coating

Selection criteria for Biomaterials

By *T.Khalil, **J. Bossert,***A.H.Ashor and *F. Abou EL-Nour

Keywords: hydroxyapatite, fluorapatite, composite materials, microhardness

Study of the microstructural and mechanical properties of plasma sprayed HAp and HAp + 15 wt-% Al 2 O 3 coatings on pure titanium

SURFACE TREATMENT OF SONOTRODE MATERIAL AW 7075

This is a repository copy of Niobium coated Ti-Al alloy: improvement of tribological behaviour, oxidation resistance and flame retardancy.

Novel Mn 1.5 Co 1.5 O 4 spinel cathodes for intermediate temperature solid oxide fuel cells

Effect of SiC Whiskers on Properties of SiC Coating for. Carbon/carbon Composites

Additive manufacturing of metallic alloys and its medical applications

Designing the surface of medical devices

Mechanical behaviour of additively manufactured materials

Effect of Alkali and Heat Treatment on Biomimetic HA Coating on Ti6Al4V

EFFECTS OF CURRENT DENSITY ON SIZE AND SURFACE MORPHOLOGY OF HIGH SPEED DIRECT NANO-CRYSTALLINE NICKEL PLATING ON TITANIUM SURFACE

Investigation on the effect of Electro-co-deposition process parameter bath temperature on Nano Structured Ni-WC Composite coating properties

Electron Beam Melted (EBM) Co-Cr-Mo Alloy for Orthopaedic Implant Applications Abstract Introduction The Electron Beam Melting Process

An Investigation of the Synthesis of Ti-50 At. Pct Ni Alloys through Combustion Synthesis and Conventional Powder Sintering

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.3, pp ,

Pressure-Assisted Low-Temperature Sintering of Silver Paste as an Alternative Die-Attach Solution to Solder Reflow

Technical University of Cluj-Napoca, Muncii Ave., Cluj-Napoca, Romania

FeCoNiAlTiCrSi high entropy alloy coating prepared by laser cladding Yanping Guo, *Suiyuan Chen, Zhaoqing Yuan, Tiantian Guo

Preparation and Tribological Investigations of PVA-H/HA Composites

SOL - GEL CHEMICAL ROUTES FOR PREPARING BIOACTIVE FLUORHYDROXYAPATITE THIN FILMS AND POWDERS

In vitro biomimetic deposition of apatite on alkaline and heat treated Ti6Al4V alloy surface

Effect of Sintering Temperature Rate on Physical Properties of Porous Tricalcium Phosphate (TCP) Ceramics

MULTILAYER SiC-MoSi 2 COMPOSITES PRODUCED BY TAPE CASTING

Titanium Surface Modification by Oxidation for Biomedical Application

PRODUCING MULTILAYER COATINGS BY MECHANICAL ALLOYING METHOD

Australian Journal of Basic and Applied Sciences. Processing and Characterization of Porous Mg Alloy for Biomedical Applications

Biomaterials in Medical device design

SIZE EFFECTS OF SIC PARTICLES ON MECHNICAL PROPERTIES OF CAST CARBON NANOFIBERS REINFORCED AZ91 MAGNESIUM COMPOSITES

Effects of Substrate Morphology on Osteoblastic Response to Thin Film Calcium Phosphate Coatings F. Horgan 1, B.J. Meenan 1 1

IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS

Y. Zhou, X. Zhou, Q. Teng, Q.S. Wei, Y.S. Shi

Chapter 3: Powders Production and Characterization

PHYSICO-MECHANICAL AND PHYSICO-CHEMICAL PROPERTIES OF BIO-INERT COMPOSITE CERAMICS

Synthesis and Characterization of α-alumina Membrane Support and Effects of Binders

Mechanical Properties of Hydroxyapatite Composites Reinforced with Hydroxyapatite Whiskers

WATER/OIL REPELLENT PROPERTY OF POLYESTER FABRICS AFTER SUPERCRITICAL CARBON DIOXIDE FINISHING

Densification and dielectric properties of barium neodymium titanium oxide ceramics

applications J.C. Huang 1, J.S.C. Jang 2, C.H. Lin 1, C.H. Chen 3, C.H. Huang 1, R.F. Chuang 1 National Sun Yat-Sen University

Accumulation (%) Amount (%) Particle Size 0.1

Porous Structure Characterization in Titanium Coating for Surgical Implants

Biocompatible coatings for corrosion control of magnesium alloys used as bio resorsable implants

Analysis of Surface Properties of Al 2 O 3 Coating over Mild Steel Using Plasma Spray Process

Analytically Modeling of In Vitro Calcium Dissolution of Plasma- Sprayed Hydroxyapatite Coatings

SOFC Powders and Unit Cell Research at NIMTE. Jian Xin Wang, Jing Shao, You Kun Tao, Wei Guo Wang

A Comparison of Corrosion Behavior of a Super Duplex Stainless Steel and an Austenitic Stainless Steel in a Molten Sn 3.0Ag 0.5Cu Lead-Free Solder

THE EFFECT OF SOL-GEL TECHNIQUE ON THE ALUMINIUM SiCp COMPOSITE

Plasma sprayed hydroxy apafite coatings t

Joint Technology Initiatives Collaborative Project (FCH) FCH-JU WP4 - Development of lab-scale cell components

EFFECTS OF CALCINATION ON ELECTROPHORETIC DEPOSITION OF NATURALLY DERIVED AND CHEMICALLY SYNTHESIZED HYDROXYAPATITE

Global Journal of Engineering Science and Research Management

Research on the High Strength Glass Ceramics/Mullite Ceramics Composites

INFLUENCE OF PHOSPHOROUS AND UREA ON THE MAGNETIC AND MECHANICAL PROPERTIES OF NANOSTRUCTURED FEPTP FILMS

The Effect of Fracture Toughness on the Deposition Efficiency of Ceramic Particles in Cold Spray

Sustainable Engineering Research Cluster, Universiti Malaysia Perlis, Blok B, Taman Pertiwi Indah, Seriab, Kangar, Perlis, Malaysia

MECHANICAL AND WEAR BEHAVIOUR OF TITANIA PLASMA-SPRAYED COATINGS

Application of liquid aluminium and FeO TiO 2 powder to the synthesis of composites

Electrochemical and electrophoretic deposition of hydroxyapatite for orthopaedic applications

Formation of Fe-base Metal Glass Coating by Gas Tunnel Type Plasma Spraying

Chapter 7. Evaluation of Electrode Performance by. Electrochemical Impedance

MANGAL ROY. Assistant Professor Department of Metallurgical and Materials Engineering

Joining of C f /SiC composites with Niobium alloy

Transcription:

International Conference on Manufacturing Science and Engineering (ICMSE 2015) Effects of TiO2 Contents on HA/TiO2 Composite Coating by Electrophoretic Deposition Lei Zhao, Huiping Shaoa, Hang Zheng Institute for Advanced Material & Technology, University of Science and Technology Beijing, Beijing 100083, China a email: shaohp@ustb.edu.cn Keywords: Hydroxyapatite; Electrophoretic Deposition; Composite Coating; TiO2; Adhesion Strength Abstract. The HA composite coating with different TiO2 contents was prepared by electrophoretic deposition in this study. The composite coatings were characterized by scanning electron microscopy (SEM), Ca/P atomic ratio in composite coatings was analyzed by Energy Dispersive Spectrometer (EDS), and the adhesion strength was analyzed by Universal Material Testing Machine. The results show that the density of HA-TiO2 composite coatings was elevated with increasing TiO2 contents after sintering at 850 C. The atomic ratio of Ca/P (calcium and phosphorus) of the HA/TiO2 composite coatings showed a rising trend with the increasing contents of TiO2 in suspensions. The atomic ratio of Ca/P was 1.69 and 1.75 which was close to the human bone (1.67), when the TiO2 content was 10g/L and 15g/L in the suspension, respectively. The thickness of the coatings increased with the TiO2 contents increasing, which was 30μm that deposited in the suspension content with 10g/L TiO2, and great combination was shown with the good uniformity of the coating. The adhesion strength was 9.10MPa as the TiO2 content was 10g/L. Introduction The hydroxyapatite (Ca10(PO4)6(OH)2, HA), is an inorganic constituent of the human bones, which can induce the growth of new bone[1-2]. It is a biomedical ceramic material that was widely used in material substitute to human hard tissues to improve the cell responses and osteo-conductivity, which can easily form a bond with the neighboring bone after planted in the human body; meanwhile, it is non-toxic, high bioactivity and high biocompatibility [3-4]. Electrophoretic deposition (EPD) is an economical technique for the preparation of uniform HA coatings on titanium alloy substrate. The EPD technique has several advantages compared to other common methods of surface coating, including short formation time, simple apparatus and the shape of substrate is unconstrained etc.[5]. However, some shortage of the EPD method limited its application, such as the HA coatings is easy to thermal decompose into tricalcium and tetracalcium phosphates when the sintering after deposition at a high temperature, the sintering temperature should be set below 1000 C to retard the decomposition of HA coating[6]. What s more, the adhesion strength between HA and substrate is not high enough because of the mismatch of thermal expansion coefficient (CPE) between titanium (αti=8.7 10-6K-1) substrate and HA coatings (αha= (14~16) 10-6K-1) [7]. The results showed that the transition of the HA coating that prepared between the substrate and the HA coating was with a proper thermal coefficient of expansion and can significantly improve the adhesion strength [8]. In this paper, the TiO2 was selected as transition layer because of the thermal expansion coefficient of TiO2 (9.0 l0-6 K-1) between titanium alloy and HA, and it can ease the residual stress. It will improve the performance of the combination between coating and the base. The functional HA-TiO2 composite coating was fabricated by electrophoretic deposition and heat-treatment in the titanium substrate surface in order to study the effects of TiO2 content on HA-TiO2 composite coating performance. 2015. The authors - Published by Atlantis Press 1566

Experiment Experimental materials Hydroxyapatite powder (30nm, Sinopharm Chemical Reagent, China) and TiO 2 powder (30nm, Sinopharm Chemical Reagent, China) were used as the raw materials. Ti-7.5Mo alloys (φ10 15mm) that prepared by gel-casting were used as metallic substrates in this study. Preparation of the Suspension and Deposition N-butyl alcohol (Sinopharm Chemical Reagent, China) was used as a solvent and the ph of the suspension was adjusted to 5.5~6.5 by adding triethanolamine. In this study, four suspensions were prepared with different TiO 2 contents, shown as Table1. The content of HA was kept at 10g/L (1g HA was added in 100ml N-butyl alcohol) in each suspension. Table1. Preparation of the suspension for HA-TiO 2 graded composite coatings Contents of The amount of TiO 2 in the suspensions[g] (added in 100ml N-butyl alcohol) TiO 2 [g/l] Suspension a Suspension b Suspension c Suspension d 5 0.5 0.3 0.1 0 10 1 0.6 0.2 0 15 1.5 0.9 0.3 0 20 2 1.2 0.4 0 Characterization Testing The microstructure of the coating was characterized by SEM, and the thickness of the coating was measured by observing the cross section morphology of coating. Elemental analysis of coating was evaluated by EDS, and the coating s atomic ratio of Ca and P can also be calculated. Schematics of adhesion strength of the coating were showed as Fig. 1. The coating and the titanium substrate was bonded with the stainless steels respectively. Tension was applied on stainless steels till the coating was peeled from the substrate. The adhesion strength was figured by the following formula. Stainless steel F Stainless Fig.1. Schematic diagram steel of the adhesion strength test for the coating F- Maximum tension while coating peeled A- Contact area of the stainless steel with the coating Results and Discussion HA/TiO 2 coating Titanium substrate σ=f/a (1) Surface morphology and the Ca/P ratio of the HA/TiO 2 composite coatings Fig.2 showed the surface morphology of the composite HA/TiO 2 coatings with different TiO 2 contents after sintering at 850 C. As can be seen, the coatings became non-uniform when the TiO 2 content increased to 15g/L and 20g/L. In fact, with increasing of the TiO 2 contents, the pore size and the number of the pore on the coatings reduced, the coatings became more compact, because a closely packed accumulation of HA and TiO 2 particles could be formed during a short time and the bonding between the HA and TiO 2 particles were strengthen by increasing the TiO 2 contents. The coatings could be porous and loose when the TiO 2 content was kept at a low level. However, the coating surface became non-uniform, which may be caused by the high potential of TiO 2, the TiO 2 particles could be deposited more easy than the HA particles. 1567 F

As can be seen in Fig. 3, there were little impurity elements on the surfaces of coatings. The atomic rate of calcium and phosphorus was 1.46 when the TiO2 content was 5g/L in the suspension, which was less than the human bone (~1.67)[9] and illustrated that the crystalline of HA was not enough. When the TiO2 content was 10g/L and 15g/L, the Ca/P atomic rate was 1.69 and 1.75 respectively, which was close to the human bone and what can be seen that the appropriate TiO2 content in the suspension could promote the ossification of HA. However, when the TiO2 content was 20g/L, the Ca/P atomic rate was up to 1.92. Fig.2. SEM images of the coatings deposited from the suspensions with 10 g/l HA and different TiO2 content (500 ): (a 5g/L, b10g/l, c 15g/L, d 20g/L) after sintering at 850 C, respectively Fig.3. EDS of HA/TiO2 coatings with different TiO2 contents (a 5g/L, b10g/l, c 15g/L, d 20g/L) after sintering at 850 C 1568

Cross Section SEM micrograph of HA/TiO2 coating Fig. 4 was the cross section SEM micrograph of HA/TiO2 coatings. It can be seen that the thickness of in the coatings increased as the TiO2 contents increased. What can be known that the coatings were very uneven when the TiO2 contents were 15g/L and 20g/L. What s more, the cracks were obvious, which could cause reducing adhesion strength greatly (Fig.4c and d). However, as can be seen thickness of coating was 25μm that deposited in the suspension content with 10g/L TiO2, and great combination was shown with the good uniformity of the coating.(fig.4b). The adhesion strength of the coatings with different TiO2 contents sintering at 850 C were shown in Fig. 5. The adhesion strength of coating was merely 4.34MPa without any TiO2, and the adhesion strength was increased from 6.85MPa to 9.10MPa while the TiO2 content was increased from 5g/L to 10g/L. However, the adhesion strength was decreased when the TiO2 content was 15g/L and 20g/L, which was 6.18MPa and 4.08MPa respectively, which may be caused by the obvious cracks on the coatings. Fig.4. Cross section SEM micrograph of HA/TiO2 coatings with different TiO2 contents (a 5g/L, b 10g/L, c 15g/L, d 20g/L) after sintering at 850 C Fig.5. Adhesion strength tests of HA/TiO2 coatings 1569

Conclusion The different TiO 2 contents composite coating was successfully prepared by electrophoretic deposition in this paper. The Ca/P atomic ratio of the HA/TiO 2 composite coatings showed a rising trend with the TiO 2 contents in suspensions increased. When the TiO 2 content in the suspension was 10g/L and 15g/L, the Ca/P atomic rate was 1.69 and 1.75 respectively, which was close to the human bone. The thickness of the coatings increased as the TiO 2 contents increasing. The thickness of coating was about 20μm that deposited in the suspension with the TiO 2 content of 10g/L, and great combination was shown with the good uniformity of the coating. The adhesion strength was 9.10MPa while the TiO 2 content was 10g/L. Acknowledgement This work was financially supported by the National Natural Science Foundation of China (No. 51274039). References [1] C.Caparrós, J.Guillem-Martí, M.Molmeneu, M.Punset, J.A.Calero, F.J.Gil. Mechanical properties and in vitro biological response to porous titanium alloys prepared for use in intervertebral implants. Journal of the mechanical of the biomedical materials, 39(2014)79-86. [2] K.Miura, N.Yamada, S.Hanada, T.K.Jung, E.Itoi, The bone tissue compatibility of anew Ti-Nb-Sn alloy with a low Young's modulus, Acta Biomater. 7(2011)2320-2326. [3] Hongjian Zhou, Jaebeom Lee. Nanoscale hydroxyapatite particles for bone tissue engineering, Acta Biomaterialia, 7 (2011) 2769-2781. [4] M.Long, H.J.Rack, Titanium alloys in total joint replacement a materials science perspective, Biomaterials. 19(1998)1621-1639. [5] Alicja Kazek-Kęsik, Małgorzata Krok-Borkowicz, Elżbieta Pamuła, Wojciech Simka. Electrochemical and biological characterization of coatings formed on Ti-15Mo alloy by plasma electrolytic oxidation. Materials Science and Engineering, C43 (2014) 172-181. [6] V.Ozhukil Kollath, Q.Chen, R. Closset, J.Luyten, K.Traina, S.Mullens, A.R.Boccaccini, R.Cloots. AC vs. DC electrophoretic deposition of hydroxyapatite on titanium.. Journal of the European Ceramic Society, 33 (2013) 2715-2721. [7] M.Mahmoudi, H.Maleki-Ghaleh, M.Kavanlouei. Electrophoretic deposition and reaction-bond sintering of Al2O3/Ti composite coating: evaluation of microstructure, phase and wear resistance. Bull. Material Science, 38 (2015) 351-356. [8] Hamidreza Farnoush, Gürol Aldıç, Hüseyin Çimenoğlu. Functionally graded HA-TiO2 nanostructured composite coating on Ti-6Al-4V substrate via electrophoretic deposition. Surface & Coatings Technology, 265 (2015) 7-15. [9] Wei R. The preparation and property research of bioactive coating on the surface of porous implant material [M]. Beijing: University of Science and Technology Beijing, 2012. 1570