UV Fluorescence Polarization as a Means to Investigate Protein Conformational and Mass Change

Similar documents
The Synergy 2, A Novel Approach to Microplate Multi- Detection for HTS and Drug Discovery

Multi-Volume Based Protein Quantification

Ratio and Spectral Scanning

PolarScreen Tyrosine Kinase Assay Kit, Far Red Protocol

Quantitation of ssdna using OliGreen Fluorescent Stain

+ M III. IMAP Screening Express Kit Product #8073 Quantity: 8000, 20 µl reactions (80 µl final volumes) Low FP. M III High FP.

Synergy NEO HTS Multi-Mode Microplate Reader and Life Technologies Reagents

Origin of Tryptophan Fluorescence Lifetimes in Solution and in Proteins. Jihad René Albani Université de Lille 1. Laboratoire Biophysique Moléculaire

Optimizing Dual-Glo Luciferase Assays with the Synergy HT Multi-Detection Microplate Reader

Validation and Comparison of Single-Step Flash and Dual-Spectral Luciferase Reporter Gene Assays using the Synergy Line of Microplate Readers

Protease Activity Assay Kit

Limit of Detection. Theoretical Lowest Concentration

Protein Structure. Protein Structure Tertiary & Quaternary

Imaging of BacMam Transfected U-2 OS Cells

Data Sheet PDE5A Assay Kit Catalog # GWB-PS22C9

LED Light Sources for Stopped- Flow Spectroscopy

Determination of Endogenous Cellular Kinase Activity Through the Use of an Automated, High Throughput AlphaScreen - Based Assay

LavaDigest Protease Monitoring Kit

Transcreener PDE Assay

Live Cell Imaging of RNA Expression

Data Sheet PDE Assay Kit Catalog # 60300

Use of Phase Contrast Imaging to Track Morphological Cellular Changes due to Apoptotic Activity

Tyrosine Kinase Assay Kit, Red*

nanodsf 2bind: Your service provider for biophysical characterization of proteins Precisely revealing protein folding and stability

Fluorescense. Aromatic molecules often fluoresce (but DNA bases don't) Excitation ~ absorbance (Differences due to: ν h ' Fluorescence

Data Sheet PDE5A Assay Kit Catalog # 60350

Contact Details. Dr Alexander Galkin. Office: MBC Room 186. Tel: (028) Frequency and wavelength.

Rapid and Simple Quantification of DNA and Protein Using the VICTOR Nivo Multimode Plate Reader

Utility of Variable Bandwidth Monochromators for Quantification of Fluorescent Probes in Produced Effluent Water

QS S Assist STK_FP Kit

IMAP TR-FRET Phosphodiesterase Evaluation Assay Kit With Progressive Binding System Quantity: 800 test points (20 L reactions)

Assessment of HDAC1 Inhibition Using an Automated, Bioluminescent Histone Deacetylase I/II Assay

Test Your Plate Reader Set-up Before Using LanthaScreen Eu Assays

Comparison of Oridonin Cytotoxicity in U-2 OS and HepG2 Cells

Technical Manual. Transcreener KINASE Assay Transcreener KINASE Plus Assay

DENATURATION OF HEMOGLOBIN IN THE PRESENCE OF TANNIC ACID

SensoLyte 440 West Nile Virus Protease Assay Kit *Fluorimetric*

Evaluating Microplate Detection Instruments

Brightfield and Fluorescence Imaging using 3D PrimeSurface Ultra-Low Attachment Microplates

FAR RED FP. GDP FP Assay. Technical Manual. v071814

ALP (alkaline phosphatase) calibrators were analyzed manually in microtiter plates to find the linearity range by following this protocol:

An Automated, Cell-based Platform for the Rapid Detection of Novel Androgen Receptor Modulators

MST Starting Guide Monolith NT.115

Z -LYTE KINASE ASSAY KIT TYR 3 PEPTIDE PROTOCOL

FAR RED FP. UDP FP Assay. Technical Manual. v042809

The mechanism(s) of protein folding. What is meant by mechanism. Experimental approaches

Introduction. Figure 1. Oris Cell Migration Assay Principle

Synergy, Cytation and FLx800 Multi-Mode Microplate Readers

Quant-iT Protein Assay Kit (Q33210)

Concept review: Fluorescence

Automated, Kinetic Imaging of Cell Migration and Invasion Assays using Corning FluoroBlok Permeable Supports

Masayoshi Honda, Jeehae Park, Robert A. Pugh, Taekjip Ha, and Maria Spies

Peter Brescia, Applications Scientist and Peter Banks, Scientific Director, BioTek Instruments, Inc.

SensoLyte 620 HCV Protease Assay Kit *Fluorimetric*

Part. no. PV4319.pps Rev. date 29 June 2006

Chapter 4 Fluorescence Resonance Energy Transfer (FRET) by Minor Groove-Associated Cyanine-Polyamide Conjugates

SensoLyte 520 Enterokinase Activity Assay Kit *Fluorimetric*

Biochemical Binding ADCC Assays Utilizing LANCE Toolbox Reagents for the Characterization of higgs and FcγR1A

A Cost-effective Workflow for High-Throughput Screening of G- Protein Coupled Receptors (GPCRs)

Adapta Assay Setup Guide on the BioTek Instruments Synergy 2 Multi-Mode Microplate Reader

Protocol part no. PV5116.pps Rev. date: 14 April 2008

Sample Quantitation. Spectrophotometry 18. Protein Assays 20. Ordering Information 23

Fluorescence Quenching of Human Serum Albumin by Caffeine

Quantify protein stability with ΔG

NHS-Activated Agarose (Dry Form)

LanthaScreen Europium Assay Setup Guide on the BMG LABTECH CLARIOstar Microplate Readers

STUDY OF THE DENATURATION OF HUMAN SERUM ALBUMIN BY SODIUM DODECYL SULFATE USING THE INTRINSIC FLUORESCENCE OF ALBUMIN

Developing a Time-Resolved Fluorescence Resonance Energy Transfer (TR-FRET) Assay

SensoLyte 490 MMP-1 Assay Kit *Fluorimetric*

Biochemical Binding ADCC Assays Utilizing AlphaLISA Toolbox Reagents for the Characterization of higgs and FcγR1A

Reversible Molecular Switching of Molecular Beacon: Controlling DNA Hybridization Kinetics and Thermodynamics Using Mercury(II) Ions

ProSEC 300S. Protein Characterization columns

SensoLyte Rh110 Factor Xa Assay Kit *Fluorimetric*

Elecrtonic Supplementary Information. Application of quantum dot barcodes prepared using biological self-assembly to multiplexed immunoassays

Investigation of dendrimers functionalized with eosin as macrophotoinitiators for polymerization-based signal amplification reactions

Characterization of Antibody-Antigen Interactions by Fluorescence Spectroscopy

SensoLyte 520 Factor Xa Assay Kit *Fluorimetric*

Tag-lite Tachykinin NK1 labeled Cells, ready-to-use (transformed & labeled), 200 tests* (Part# C1TT1NK1)

Universal Methyltransferase Activity Assay Kit

SensoLyte 520 MMP-1 Assay Kit *Fluorimetric*

Case 7 A Storage Protein From Seeds of Brassica nigra is a Serine Protease Inhibitor

Effect of Liquid Handling Quality Control on Biological Assay Performance. Webinar sponsored by Artel Nathaniel Hentz, Ph.D.

BoTest A/E Botulinum Neurotoxin Detection Kit- Detailed Description

Sample Quantitation. Protein Assay Kits 20. Spectrophotometry 23 Cuvettes 25

Rapid Measurement of IgG Using Fluorescence Polarization

White Paper. Ion Exchange with PureSpeed Tips A Powerful Chromatography Tool

Z -LYTE KINASE ASSAY KIT SER/THR 9 PEPTIDE PROTOCOL

SpectraMax Paradigm Fluorescence Polarization (FP) Detection Cartridge User Guide

Appendix IV Version

TAG-LITE RECEPTOR LIGAND BINDING ASSAY

Impact of Liquid Handling Variability on In Vitro Biochemical Assay Performance: A Look at Protein Binding and Enzyme Assay Classes

DNA Hybridization and Detection

AnaTag 5-FAM Protein Labeling Kit

SAH Methyltransferase TR-FRET Assay

SensoLyte Plus 520 MMP-1 Assay Kit *Fluorimetric and Enhanced Selectivity*

SensoLyte FDP Alkaline Phosphatase ELISA Assay Kit *Fluorimetric*

SensoLyte Rh110 Factor Xa Assay Kit *Fluorimetric*

SensoLyte 490 MMP-1 Assay Kit *Fluorimetric*

TECHNICAL BULLETIN. In Vitro Bacterial Split Fluorescent Protein Fold n Glow Solubility Assay Kits

CBI Toolbox Tour 2015

Transcription:

A p p l i c a t i o n N o t e UV Fluorescence Polarization as a Means to Investigate Protein Conformational and Mass Change Using Intrinsic Tryptophan Fluorescence in Conjunction with UV-capable Polarizers Paul Held Ph. D. and Kyle Davis, Applications Department, BioTek Instruments, Inc., Winooski, VT The essential amino acid tryptophan is intrinsically fluorescent with excitation in the UV range of the spectrum. This physical characteristic can be used to investigate peptides and proteins that contain this amino acid. Here we describe the use of the Synergy H1 reader in conjunction with UV-capable fluorescence polarizers to investigate conformational and mass changes of proteins in solution. Introduction Key Words: Tryptophan Intrinsic Fluorescence Fluorescence Polarization Protein Structure BioTek Instruments, Inc. P.O. Box 998, Highland Park, Winooski, Vermont 05404-0998 USA Phone: 888-451-5171 Outside the USA: 802-655-4740 Email: customercare@biotek.com www.biotek.com Copyright 2014 Fluorescence polarization (FP) is a fluorescence detection technique that is based on the observation that fluorescent molecules, when excited by plane polarized light, will emit plane polarized light. In solution, proteins are free to rotate, thus the plane of polarized light emitted can change based on the fluorescence lifetime of the fluorophore in question and the extent of rotation the molecule undergoes during that time frame. The molecule s rotational speed is influenced by solution viscosity, absolute temperature, molecular volume and the gas constant. If one keeps viscosity and temperature constant, then the key variable for rotational speed differences is molecular volume or to a first approximation, molecular weight. Fluorescence polarization (FP) measurements are made with two different polarizing filters that are parallel and perpendicular to the plane of the polarized excitation source. As stated previously, polarization values for any fluorophore complex are inversely related to the speed of molecular rotation of that complex. Because the speed of rotation is related to the size of the molecule, polarization values will be high with large molecule complexes, and low with small molecules. Typically the measured fluorescence is produced by an exogenous fluorescent compound such as fluorescein or Rhodamine. These compounds are covalently linked to peptides or nucleic acids and used as tracers to assess changes in mass resulting from binding events or proteolysis. Intrinsic polarization measurements are made without an exogenous fluorescent tracer, using on the inherent fluorescence of the polypeptide. The intrinsic fluorescence of a folded protein is a mixture of the fluorescence from individual aromatic residues, with the tryptophan providing the most significant portion. Tryptophan has an indole ring structure with wavelength of maximum absorption at 280 nm and an emission peak that ranges from 300 to 350 nm depending in the polarity of the local environment (Figure 1). Tryptophan is a relatively rare amino acid; with many proteins contain only one or a few tryptophan residues. Therefore, tryptophan fluorescence polarization can be a very sensitive measurement of the conformational state of individual tryptophan residues. The advantage compared to extrinsic probes is that the protein itself is not changed. The use of intrinsic fluorescence polarization for the study of protein conformation is in practice limited to cases with few (or perhaps only one) tryptophan residues, since each experiences a different local environment, which would give rise to an averaged response. Figure 1. Tryptophan structure.

Materials and Methods Protease (cat # P5147), NATA (cat # A6501), RNase T1 (cat # R1003), glucagon (cat # G2044), melittin (cat # M2272), human serum albumin (cat # A9511), bovine serum albumin (cat # A3294), basic myelin (cat # M1891), lysozyme (cat # L6876), tryptophan HCl (cat # T8941) and Trp Met Asp Phe NH2 HCl peptide (cat # T6515) were purchased from Sigma Aldrich (St. Louis, MO). Solid black 96-well microplates (Cat # 3915) were from Corning, (Corning, NY). All other chemicals were reagent grade. Ratiometric Experiments Mixtures of different molar ratios of human serum albumin (HSA) and tryptophan were made from 100 µm stock solutions. Eight replicate aliquots (100 µl) of each mixture were pipetted into wells of a black sided 96-well plate and the fluorescence polarization determined. Reactions were carried out under denaturing (8 M guanidine or 10 M urea) and native conditions. Protein Digestion Results The fluorescence polarization values for mixtures of large and small molecules are determined by their relative ratio. An excess of large molecules relative to small will result in a large polarization value, while an excess of small molecules will result in low polarization. This was demonstrated by mixing tryptophan amino acid with human serum albumin (HSA). HSA is a 67kD protein that only contains one tryptophan amino acid. However due to its size fluorescence polarization values obtained using intrinsic fluorescence will be high. Conversely, the amino acid tryptophan is quite small and would be expected to have a low polarization value in solution. Figure 2 demonstrates the ability of the Synergy H1 with UV-capable polarizers to distinguish different molar ratios of tryptophan and HSA. Mixtures that are predominately HSA have polarization values of approximately 175 mp, while those that are predominately tryptophan have values approximately 40 mp. In addition, these data are a compilation of multiple experiments, indicating the repeatability of the polarization measurements. HSA protein (100 µm final concentration) was digested with various concentrations of Protease enzyme in the presence of 10 mm phosphate (ph 7.5) buffer at 37 C for 4 hours. The fluorescence polarization was the measured. For kinetic experiments, reactions were initiated by the addition of HSA and fluorescence polarization monitored every 10 minutes. Protein Denaturation HSA protein (100 µm final concentration) was incubated with various concentrations of guanidine HCl in the presence of 10 mm phosphate (ph 7.5) in a total volume of 100 µl per well buffer at room temperature for 2 hours. After incubation the fluorescence polarization was determined. Melittin Polymerization 2,000 Cells Melittin protein (100 µm final) was incubated with various concentrations of sodium chloride in the presence of 10 mm phosphate (ph 7.5) buffer at room temperature for 30 minutes. After incubation, the fluorescence polarization was the measured. Polirization Measurements Fluorescence polarization was measured in a Synergy H1 Multimode microplate reader configured with UV-compatible polarizers. For all measurements, a 284/10 excitation and a 340/30 emission filters were use in conjunction with a 320 nm cut off dichroic mirror. PMT gain setting was set to 50 with 10 reads per data point. Figure 2. Polarization values of mixtures of human serum albumin and tryptophan in non denaturing conditions. Data represents the mean and standard deviation of at least eight separate determinations from multiple experiments. Polarization measurements using the intrinsic fluorescence of proteins are based on the ability of tryptophan to rotate in solution. Tryptophan in proteins is normally located within the hydrophobic center of most proteins as part of a tertiary structure, drastically reducing its ability to rotate independently of the entire peptide. If the tertiary structure is completely denatured tryptophan moieties within polypeptide have some rotational freedom within the polymer that the rigid native peptide would not necessarily have. This is observed in Figure 3 where the fluorescence polarization of tryptophan-hsa mixtures was determined in their native and denatured state. 2

Under denaturing conditions the maximal FP values are significantly reduced (40%) as compared to that observed under native non-denaturing conditions. Whereas samples that are substantially tryptophan are not affected to any extent. The essence of fluorescence polarization is the ability to distinguish differences in mass. Digestion of human serum albumin with general protease enzymes results in the protein being reduced into smaller and smaller peptides. Because of the single tryptophan moiety in the HSA protein, only peptide fragments containing the amino acid are fluorescent. Therefore, with the continual digestion of HSA with protease the fluorescent fragments would be expected to become smaller over time. As demonstrated in Figure 5, samples containing either 100 µg/ml or 500 µg/ml protease enzyme have decreasing polarization values over time, while samples that lack protease have a constant polarization. Figure 3. Comparison of native and denatured polarization. Mixtures of HSA and tryptophan were made under native or denaturing (8 M guanidine or 10 M urea) conditions and the fluorescence polarization determined. Data represents the mean and standard deviation of at least eight replicates from multiple experiments. The ability of tertiary structure to influence fluorescence polarization is demonstrated in Figure 4. When human serum albumin (HSA), which only contains a single tryptophan moiety, is subjected to increasing concentrations of the denaturing compound guanidine the fluorescence polarization first increases approximately 10% before significantly decreasing. This increase is due to the preliminary unfolding of the protein which increases its molecular volume; while the decrease is attributable to a great extent of unfolding which releases the tryptophan residue from the hydrophobic core of the protein allowing the indole ring to rotate independently of the protein. Because the tryptophan is still part of the protein backbone, the polarization value is still significantly greater than tryptophan in solution when the protein is completely denatured. Figure 5. Change in polarization over time of HSA with digestion with protease. Samples in replicates of eight were treated with 0, 100 or 500 µg/ml of protease enzyme at 37 C and the fluorescence polarization determined kinetically. Data represents the mean and standard deviation of eight determinations. By using a series of protease concentrations in conjunction with a fixed digestion time one can plot changes in polarization as a function of enzyme concentration. As demonstrated in Figure 6, with increasing protease concentrations the resultant polarization value decreases after a four hour digestion. HSA, which consists of 350 amino acids with only one tryptophan moiety, is cleaved into smaller fragments over time. Because only fragments containing tryptophan are excited with UV light, fluorescence polarization measurements reflect the relative length of only the fragments with that amino acid. Figure 4. Polarization of HSA with increasing guanidine concentrations. Human serum albumin (HSA) was itreated with different amounts of guanidine-hcl. After a 30 -minute incubation the, fluoresce polarization with UV excitation was determined. Data represent the mean of at least eight separate determinations from multiple experiments. Figure 6. Fluorescence polarization of HSA with Protease Enzyme Titration. HSA was treated with various concentrations of protease enzyme for 4 hours at 37 C. Data points represent the means and standard deviation of at least eight replicates from multiple separate experiments. 3

As shown in Figure 5, with increasing amounts of time the fragment length decreases or as shown in Figure 6 with increasing amounts of enzyme the same thing can be achieved. Because the digestion does not proceed to the point of individual amino acids, the polarization values at maximal enzyme concentrations are greater than that observed with tryptophan. UV-fluorescence polarization can be used to discern peptides with different molecular masses. As demonstrated in Figure 7, the differences in mass of native proteins can be discerned using fluorescence polarization. While short peptides with molecular weights less than 1000 behave in a linear fashion, larger peptides have less significant increases in polarization with increasing mass suggesting that secondary and tertiary structure certainly plays a role in the ability of tryptophan to freely rotate in solution. Many of these proteins (e.g. HSA, melittin, basic myelin, glucagon, RNaseT1 and Trp Met Asp Phe peptide) possess only one tryptophan per polypeptide chain and polarization values from these would reflect the rotation of this single amino acid. BSA and lysozyme contain 2 and 4 tryptophans respectively; as such the FP value returned would reflect an average. Figure 8. Melittin multimer formation. Melittin protein was incubated for 30 min with increasing concentrations of sodium chloride at ph 6.5 and the fluorescence polarization determined. Data represent the mean of eight determinations. Discussion While the measurement of intrinsic protein fluorescence in microplates has been used extensively [1], the determination of fluorescence polarization from the same signal has not received appreciable use. These data indicate that appropriately configured Synergy Multi-Mode Microplate Readers can be used to make fluorescence polarization determinations from intrinsic protein fluorescence. Figure 7. Comparison of polarization and peptide mass. The fluorescence polarization of several different peptides (Protease, NATA, RNase T 1, glucagon, melittin, human serum albumin, bovine serum albumin, basic myelin protein, lysozyme, Trp Met Asp Phe NH2 HCl peptide and tryptophan) with different molecular weights was determined at ph 7.5 under native non-reduced conditions. Data represents the mean of eight determinations. Fluorescence polarization is in essence an assay that measures changes in size. Binding events where a small labeled ligand attaches to something larger, the result being a larger rotational mass. The fluorescence polarization measurements of these reactions are effectively the average of a mixture of labeled ligand (small) and labeled bound ligand (large) molecules, with the unlabeled large molecule being invisible. Tryptophan and HSA, which only has one tryptophan, are functional equivalents of a labeled ligand and a ligand bound to a receptor respectively. Mixtures of the two molecules should present with different polarizations values based on their molar ratios. Melittin, a 26-amino acid peptide from Apis mellifera bee venom, has been used as a model to study protein folding [2]. Melittin converts from a monomeric random coil to an α-helical tetramer with increasing ionic strength [2]. With dimer and tetramer formation the rotational mass increases substantially. As demonstrated in figure 8, this change in mass can be monitored with fluorescence polarization. The digestion of a polypeptide will result in fragments of smaller size than the original molecule. Because intrinsic fluorescence is generated primarily from tryptophan emission, polarization measurements of those peptides effectively mimic the size of peptides that contain tryptophan, while the other fragments are invisible. Proteins with more than one tryptophan will result in a multitude of fluorescent fragments with the resultant polarization value being the average polarization of all the fragments. 4

Denaturation studies suggest that the tryptophan moiety in HSA is located in a region of tertiary structure [3]. Fluorescence polarization in completely denatured conditions is markedly less than that observed under native conditions (Figure 3). In experiments with various amounts of denaturing reagent the FP values increase slightly with low amounts of denaturant before decreasing (Figure 4). Fluorescence polarization with UV excitation of HSA is essentially a measurement of the ability of a single tryptophan to rotate freely. The native protein of course has a tertiary structure that allows the protein to rotate as a unit. With low concentrations of guanidine denaturation the protein begins to unravel, effectively increasing in rotational size while still keeping the tryptophan amino acid locked in its local tertiary structure, resulting in a higher polarization value. With further denaturation the protein is completely relaxed, allowing the tryptophan amino acid to rotate freely within the polypeptide amide linkage of the protein that is measured as a decrease in the polarization value. Fluorescence polarization measurements using visible light excitation wavelength in microplates have been performed as a matter of routine. These experiments employed a covalently linked fluorescent tracer attached to the ligand of interest. The assumption of these assays is that the tracer does not interfere with the measurement. Polarization measurements of individual peptides and proteins with small numbers of tryptophan moieties can be advantageous in that there is no requirement for modification of the protein. The intrinsic physical property of the polypeptide is used as the fluorescence source. The caveat being that the reader hardware is capable of making measurements in the UV portion of the light spectrum. These data are an example of the capability of the Synergy H1 Multi-Mode Microplate Reader when configured with UV-capable polarizing filters. References 1. Held, P. (2003) Peptide and Amino Acid Quantification Using UV fluorescence in Synergy HT Multi-Mode Microplate Reader, BioTek Instruments Application note, http://www.biotek.com/resources/articles/ peptides-amino-acids-fluorescence.html 2. Wilcox, W. and D. Eisenberg (1992) Thermodynamics of Melittin Tetramerization Determined by Circular Dichroism and Impluications for Protein Folding, Protein Science, 1:641-653. 3. Kumar, S. and R. Swaminathan (2007) Employing the Fluorescence Anisotropy and Quenching Kinetics of Tryptophan to Hunt for Residual Structures in Denatured Proteins, J. Chem. Sci 119:141-145. 5 AN101314_16, Rev. 10/13/14