National laws. National Competent Authority / Authorities. Orders, ordinances (supervision)

Similar documents
Conformity Assessment of Own Brand Labelling

WELMEC Application of module D Quality assurance Under directive 2014/32/EU (MID) or directive 2014/31/EU (NAWID)

Medical Device Directive

COMMISSION RECOMMENDATION. of XXX. on the audits and assessments performed by notified bodies in the field of medical devices

Manual for ITC's Clients 2016 Conformity assessment of in vitro diagnostic medical devices pursuant to Council Directive 98/79/EC

Guide to the in-vitro diagnostic medical devices legislation

ISCC 204 AUDIT REQUIREMENTS AND RISK MANAGEMENT. Version 3.0

MEDICAL DEVICE. Technical file.

ISO 13485:2016 Medical Devices-Quality Management Systems- Requirements for Regulatory Purposes. Theresa McCarthy

WELMEC European cooperation in legal metrology

Manufacturers of in vitro Diagnostic

Checklist for the assessment based on the standards

EU Update Proposed Regulations, Own Brand Labelling, Unannounced Audits

Manufacturers of In-Vitro Diagnostic

Effects of the European MDR on the Quality Management System. Karl-Heinz Spohn

BSI Audits for MDR Certification

TECHNICAL STANDARD. Inputs. Suitable for use in Organic Agriculture

Manufacturers. Factsheet for. of Medical Devices. Medical Devices Regulation (MDR) background. Act now to be ready on time!

Surveillance and CoP clearance

QMS Aspects of the MDR (& IVDR)

Manufacturers. Factsheet for. of Medical Devices. Medical Devices Regulation (MDR) background. Act now to be ready on time!

Bridging gaps: medical device directive vs regulation. Geert Corstens 1 November 2018

WELMEC European cooperation in legal metrology

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Impact of the MD/IVD Regulations on Quality Management Systems

Bundesanstalt für Materialforschung und -prüfung (BAM) Pyrotechnics Division 2.3 Explosives D Berlin Berlin,

MMedical Devices. Article 12 MDD. nagement. Combining Medical Devices (Guideline on article 12 of the MDD) POSITION. Council Directive 93/42/EEC

The New EU Medical Device Regulation (MDR) An Active Device Lifecycle Approach Implementation and Remediation Activities

Unannounced Visits. Welcome! We will start the webinar presentation at 9am. Copyright 2014 BSI. All rights reserved.

Korean Medical Devices Regulations

Experience with Directive 93/42/EEC (MDD)

Notified Bodies Recommendation Group

BS2482 TIMBER BOARDS ASSESSMENT REPORT. Assessment Summary

Chain of Custody Standard

MINISTRY OF HEALTH ORDINANCE

EN39 TUBE ASSESSMENT REPORT. Assessment Summary

Vendor Qualification Survey

INSPECTION PROCESS INPUTS TECHNICAL STANDARD INSPECTION PROCESS. Inputs suitable for use in Organic Agriculture

ASQ Tappan Zee Section Medical Devices, New Regulations and Standards. 26 th September / V. Fischer / Rev. 01

CE marking is regarded as a passport for products to enter and circulate freely within the 30 counties forming part of the EEA.

Medical Device Regulation Overview

Inspection of the conduct of clinical evaluations on medical devices in the premises of healthcare providers

UNICEF TECHNICAL REQUIREMENTS FOR MEDICAL DEVICES (MD)

Alaska Responsible Fisheries Management (RFM) Chain of Custody Standard Issue 2.4 November 2015

Certification Programme No. PCW-12. for construction products System 1, 1+ (certification of constancy of performance) CPR-1,1+

MEDICAL DEVICES: Guidance document

Primary Distribution Activities

Supplier. Quality Manual

OPAC EN Operating Procedure for the Attestation of Conformity of Structural Bearings in compliance with Annex ZA of EN 1337/3/4/5/6/7

Annex GSPP-definitions and explanation scopes. Version 1.5 Valid from 11 th December 2017 I

Contents. Regulatory Bodies... 13

The Pressure Equipment Directive 2014/68/EU. Photo: nostal6ie/ Shutterstock

TUV SUD BABT PRODUCTION QUALITY CERTIFICATION SCHEME

Medical Device Regulatory Framework

Technical documentation. Capita Selecta proposed MDR

New EU Medical Device Regulations.are you ready? Angela Stokes Senior Director Regulatory Affairs March 2017

Quality Management System MANUAL. SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702

Panel Discussion: European Medical Device Regulations Preparing for the Storm Moderator: Lenita Y. Sims Spears, Senior Quality Consultant/Senior

Chain of Custody Standard

The upcoming EU MDR. Gert Bos. - key changes overview. Executive director & Partner. ..the practical approach

PEFC Certification System Netherlands - Scheme Description

ISO 13485:2016 The Final Countdown

Legal Obligations of Distributors under the Construction Products Regulation and other Associated European Legislation as from 1 st July 2013

Guide for Class I Manufacturers on Compliance with European Communities (Medical Devices) Regulations, 1994

Medical Device Regulatory Framework 9 SEPTEMBER 2015 FUNDISA CONFERENCE JANE ROGERS

Med-Info. Introduction to Korean medical device regulations. TÜV SÜD Product Service GmbH

QUESTIONNAIRE FOR COMPETENT AUTHORITIES TO BE USED FOR ASSESSMENT, REASSESSMENT AND SELF- EVALUATION

Review of HPRA Draft Guide to Distribution of Medical Devices, including in vitro diagnostic Medical Devices

UNANNOUNCED EU MEDICAL DEVICE AUDITS BY NOTIFIED BODIES: IMPACT ON SUPPLIERS

Post market Surveillance ISO EU Medical Device Regulation

INSTRUCTIONS FOR CERTIFICATION OF FACTORY PRODUCTION CONTROL

Section No.: PM 22 Issue No. 01 Issue Date Page 1 of 9 Rev. No. 03 Rev. Date: Procedure for Audit of a Multi-site Organization

What to expect from MDR Authorised representatives? Sandra Ferretti Chief Compliance Officer & Public Affairs Director

SUPPLIERS AND SUBCONTRACTORS

Medical Device Regulation

Self-Care Medical Devices Framework. Dr. Simone Breitkopf Head HEOR, Governmental and Public Affairs

Guidance Document. Meeting Requirements as a Registered Food Importer. A guidance document issued by the Ministry for Primary Industries

Medical Devices. LATVIA LAWIN Klavins & Slaidins

AGENCE NATIONALE DE VERIFICATION DE CONFORMITE AUX NORMES (AVCN) EXPORTER AND IMPORTER GUIDELINES NCAP EXPORTER AND IMPORTER GUIDELINES

Medical Device Regulatory Roadmap SAMED Conference 2-3 December 2015

Supplier Quality Agreement

TÜV SÜD BABT Production Quality Certification Scheme

IAF Mandatory Document. for the Audit and Certification of a Management System Operated by a Multi-Site Organization (IAF MD 1:2018)

ISO 14001:2004 Summary of significant changes

Guide to Registration of Persons Responsible for Placing In-vitro Diagnostic Medical Devices on the Market

Course Title ID Duration Basic Premium. Biological Evaluation of Medical Devices: A Risk-Based Approach N mins

Medical Device Regulatory Roadmap SAMED Conference 2-3 December 2015

GUIDANCE NOTES FOR MANUFACTURERS OF CLASS I MEDICAL DEVICES

MDSAP AUDIT PROCESS. A Manufacturer s Perspective. Connie Hoy EVP Regulatory Affairs Cynosure, Inc.

Industry Outreach Quality

QSS 0 Products and Services without Bespoke Contracts.

Medical Devices. The technical requirements also apply when the submitter is not the legal manufacturer 1 (i.e: a distribution company).

EU MDR 10 Things Packaging Engineers Should Know

Manufacturera Dental Continental; Declaration of Conformity DC- 1 issue 2 (April 2007) Page No 1 of 5

QUALITY AGREEMENT. This Quality Agreement is made between. (Customer Legal Entity Name Hereinafter called CUSTOMER ) And

FDA 21 CFR Part 820 vs. ISO 13485:2016 Comparison Table created by greenlight.guru

Post Market Surveillance (including PMCF): common non compliances

ISO and UAV Audits Preparation and Client Rights

Regulatory Requirements & Recent Changes, including expectations for APIs & IMPs

Laboratory Quality Assurance Manager & Laboratory Assessor RULES & HANDBOOK

Transcription:

1

The Regulatory World Only for products classified higher than class I: Notification of the body, Supervision National laws National Competent Authority / Authorities Orders, ordinances (supervision) Directives European Commission Registration of: the company the products clinical studies planned adverse incidents reports (Vigilance) Notified Body Information of new products and product changes Manufacturer Certification of the manufacturer, permission of CE marking the products, surveillance Sub-contractor 2

Who is the Manufacturer? Who (the natural or legal person) places the product on the market under his own name or trademark is the manufacturer. Although he may not be the person who designed, manufactured, packaged or labelled the product (e.g. on an contractually basis) but nevertheless the regulatory responsibility rests with him alone. He must ensure that all requirements of the directive are fulfilled, also at the site of his sub-contractors. 3

OEM vs OBL ORIGINAL EQUIPMENT MANUFACTURER OEM designs and manufactures medical devices which are already placed on the market under his name OWN BRAND LABELLING manufacturerm Own Brand Labeller is the company/person who places on the market under his own name or trademark a device already CE marked by an OEM and is therefore the manufacturer (as defined) for the purpose of the regulations 4

Who is NOT Considered as OBL a legal manufacturer may not actually carry out any design or manufacturing activities themselves but have them performed by third parties on their behalf and they are placing MD(s) on the market for the first time virtual manufacturer. a legal manufacturer is purchasing finished devices to label with their own name but which have NOT already been CE marked by the original manufacturer. The Notified Body would need to assess the full technical documentation for the device to verify compliance of the device. a distributor whose name appears on the packaging, labels or instructions for use is NOT considered to be an Own Brand Labeller if it is clear that the product is sold under the actual manufacturer s own name. 5

CE Marking of OBL it is responsibility of the OBL to meet all regulatory requirements. The device must be covered by the OBL s conformity assessment certificate and be approved by the OBL s notified body the conformity assessment relating to the device itself will consist of verifying that the existing CE marking conformity approval held by the OEM (the third party providing the device to the OBL) is valid and current, and that the device in question is the same device. The assessment therefore needs to cover sufficient documentation to demonstrate this 6

Requirements to OBL Documentation Declaration of Conformity Description of devices (identity of OEM/OBL MDs; classification; index of OEM TF) Copies of the OEM s certificates (CE, QMS, etc.) OBL QAS documentation (vigilance & post-market surveillance) Labeling procedure; OEM labels vs OBL draft labels OEM/OBL devices IFUs Solutions adopted to meet the essential requirements Results of the risk analysis Regulatory contract between OEM and OBL 7

OEM - OBL Regulatory Contract OEM must transfer enough information to OBL so that he can become a manufacturer and vice versa OBL must take sure that he become possessed of sufficient information/documentation in order to take the responsibility as manufacturer. A contract must meet the requirements in the directives and protect the OEM for loss of valuable know-how about his products: scope: companies involved, products (traceability), period of contract validity agreements upon changes in production/certification of OEM (regulations governing relevant procedures: testing) vigilance & recalls (+complaint handling & information of the partners) OBL access to technical documentation (rules for maintaining the documents and records/valid documents - responsibility for these, also after the business relation has finished) NB & CA access to OEM s premises & technical/production/registration documentation inspections/audits 8

Post-Production Obligations The conformity assessment needs to cover the mandatory QS requirements to ensure that the OBL can meet the Directive(s) obligations as the legal manufacturer, including documents for: Procedures for labelling of the device and display of the CE marking Procedure to prepare and review a Declaration of Conformity Process to identify what is a significant change and what should be notified to the NB Procedures for registration with Competent Authorities Process for selection and control of the OEM, demonstrating responsibility for design, manufacture and labelling of the product In case the classification requires conformity assessment by a full quality assurance route the OBL will need to demonstrate design control procedures, 9 even though in effect he has sub-contracted the design activities to the OEM.

Import & Sale " P " Design and production, outside the EC contract Sales under name P within the EC " I " Certificate Annex II or other Labeling Manufacturer P, address Product: 55553434341 Charge cc CE 1023 Importer or representative in the EC e.g. " I" or R, address Contract: legal requirements, documents of the QA-System of the products/technical and production. " R " or representative of P" Keeps the documentation (actual) Informs of the authorities 10

Import & Sale Design and production, outside the EC Sales under name I within the EC! " P " Labeling contract Contract: legal requirements, documents of the QA-System of the products / technical and production. Certificate Annex II or other " I " Manufacturer I", address Product: 55553434341 Charge cc CE 1023 Maintains a QA-System Informs of the authorities Keeps the documentation (actual) I is the (virtual) manufacturer 11

The Economic World is More Complex Design / construction production labelling " P " " G " Sterilisation contract " S " Distribution, sales under own label S. The responsibility for all activities (also at the sites P and G ) rest at company S alone! S has to present to the auditor all documents, proofs and records necessary to verify that the legal and normative requirements are fulfilled. If necessary the auditor has to perform audits at all sites! 12

Own Label, Import or Domestic Design Production Labelling " P " " S " Sales under its own name Auditor Auditor Case 1: All documents necessary are at the site of S. These are maintained on an contractual basis. Not realistic. Especially for the activities: design, production, testing. The knowhow of the company P would be transferred to S. Case 2: Company S refers in its QA-documentation to the documents and procedures at the site of company P. Company P holds its product and system specific documents alone. The responsibilities for the documents and for the common procedures (QA-system) are laid down in a contract. By supervisions (audits) S proves if P maintains the contractual requirements. No complete evidence can be achieved that P holds all legal demands / requirements. 13

Own Label, Import or Domestic Design Production Labelling " P " " S " Sales under its own name Case 3: S holds the technical documents (Product Master File, Risk Analysis). The responsibilities for the documents and the procedures at site P are ruled in a contract. Company P is certified acc. to EN ISO 13485 by a notified body. Approval acc. MDD - annexes for S can be possible without an audit at the site P. This depends from the completeness and contents of the documents. Certificate acc. to ISO 9001 is not sufficient. Case 4: S holds parts the technical documents (Product Master File, Risk Analysis is for its own activities). The relationship and the main common procedures with P are contractual. P holds an approval by a notified body for the identical products under its own name acc. to a suitable annex of the MDD. Approval acc. MDD - annexes for S will be possible without an audit at the site P. This depends from the completeness and contents of the documents. The identity 14 of the products under consideration must be demonstrated.

Deficiencies From Our Experience list of applicable documents, e.g. standards, directives, IfUs, labels usually not updated & incomplete external approvements for the product itself are missing or they are not applicable to it (EN ISO 60601, EN 550, 552, 554...) risk analysis is not complete, the fulfillment of the essential requirements is not completely demonstrated. The residual risks are not evaluated (elaborated just in formal manner) there are evidences missing, that the products hold the stated capacities, specifications (if necessary: clinical studies) 15

Thank you for your attention Jan Petrik, PhD. Institute for Testing and Certification, Inc. Zlín Branch Office ITC Slovakia, Mlynske Nivy 54 SK-821 05 Bratislava SLOVAK REPUBLIC jpetrik@itczlin.cz www.itczlin.cz phone +421 2 5342 1046 fax +421 2 5342 1032 16