External Thermal Insulation Composite Systems

Similar documents
Distemper-Based Paints

Insulating Plaster/Render

Mineral-Bonded Wood-Wool Boards

Paper and Wood Glues from Renewable Raw Materials

MDF Boards Dry Process Boards

Laminated Wood-Based Boards for Furniture and Interior Fitments

Annex II. Declarations

of the indoor paint or varnish

Requirements for Chemicals Management for Private Label Suppliers Textiles

RESOPAL -Decorative High Pressure Laminates HPL according to EN 438

EU Health and Safety Data Sheet

Summary Of Criteria For A Community Eco-Label On Bed Mattresses

EU ECOLABEL USER MANUAL GROWING MEDIA, SOIL IMPROVERS AND MULCH

Benetton Group srl 2018 Detox Programme Guideline

Product Data Sheet RESOPAL EXCELLENT

Xmultiple Technologies, Inc. Ozone Depleting Substances (ODX) - Products & Hazardous Materials Statement

Appendix 1 to SPCR 141. Industrially compostable polymeric waste Requirements and test methods

Appendix 2 to SPCR 141 Polymeric waste compostable in small scale (home) composts Requirements and test methods

Technical Leaflet. Product Data Sheet for High Pressure Laminates (HPL)

TRAINING ON INTRODUCTION TO SUSTAINABLE PUBLIC PROCUREMENT (SPP) AND ECO-LABELS DAY III USE OF GREEN LABELS IN SPP

Technical Leaflet. Product Data Sheet for HPL Composite Panels

Appendix 4 to SPCR 141. Polymeric waste degradable by abiotic and subsequent biological degradation (A+B degradable) Requirements and test methods

T E S T R E P O R T N o

Green Label Product Products made from rubberwood

SUSTAINABILITY DECLARATION 9000

BLUE ANGEL. The German Ecolabel. Low-Emission Thermal Insulation Material and Suspended Ceilings for Use in Buildings DE-UZ 132. Basic Award Criteria

Kingdom of Cambodia Nation Religion King

Zotefoams plc. Technical Information Sheet TIS 20 (previously BTI5) Toxicity testing of Zotefoams materials INTRODUCTION

Korea Eco-label Standards EL241 Revised 28. Mar Ministry of Environment Paints EL241:2014

Recycled Content Materials Assessment Methodology

HONG KONG GREEN BUILDING COUNCIL

Green Label Product Steel Furniture (TGL-21-R2-14)

Technical Data Sheet Sto-Primer

EU Directives and National Regulations for the Recycling and Disposal of Waste Wood

REQUIREMENTS FOR DISCHARGING OF WASTE WATER FROM THE CHEMICAL INDUSTRY

EUROPEAN QUALITY ASSURANCE FOR COMPOST

Technical Data Sheet Sto-RFP

EU-flower criteria. Printed Paper Products

Certificate of non-use of The Controlled Substances

REWE Group Detox Program

HONG KONG GREEN BUILDING COUNCIL

SYSTEMDATENBLATT Sika Cable-System

ENVIRONMENTAL PRODUCT DECLARATION

BIU Büro für integrierten Umweltschutz

Basic Criteria for Award of the Environmental Label. Low-Emission Thermal Insulation Material and Suspended Ceilings for Use in Buildings RAL-UZ 132

Development of Green Public Procurement Criteria for Indoor and Outdoor Paints and Varnishes

No: UK-WER _english. 1. Unique identification code of the product-type UK-WER _english

DECISIONS. (Text with EEA relevance)

Foam Fire Extinguishing Agents

ANAB National Sustainable Architecture Association

SUSTAINABILITY DECLARATION SPACE

Metal Wall Cladding Lindner Free 910 Environmental Product Declaration acc. to ISO Holder of the declaration

Ready-to-use structural plaster for interior use

Technical data sheet. Diesco Silicon plus. Silicon resin façade paint. High-grade, matte silicon resin facade paint with SIO-TEC formula

Colanyl 500 Hostatint 500 FOR DECORATIVE PAINTS AND COATINGS

Colourants and pigments

Green Label Product Fluorescent lamps (TGL 2- R4 15)

HONG KONG GREEN BUILDING COUNCIL

The Ericsson lists of banned and restricted substances

GEV Classification Criteria

Duraflex PF is a premium flexo solventbased multi substrate laminating system.

AGE RANGE: Soluble Lead Content Test on Metal Toy Accessories Pass. 2. Heavy Elements Analysis Pass Toxic Element Migration Test Pass

Lutron KS 1. Technical Information

Products: 23 Ormbsby Place, Wetherhill Park, NSW 2164 MARMOLEUM PHONE:

Office Soft Furnishing

Valmet guidance on restricted materials in products 1/8

1. Description 2-component varnish for gravure and flexography with high gloss and very good resistance to solvents.

Guideline Regarding Non-Containment Management on Fujitsu Group Specified Chemical Substances

Test Report No

Returnable Containers and Packaging Materials. Certification Criteria

SUSTAINABILITY DECLARATION CAPELLA

DRAFT UGANDA STANDARD

Industry Consortium CB4REACH. Information Letter 3

millimetri4 wall system

1. Soluble Lead Content Test on Metal Toy Accessories Pass. 2. Heavy Elements Analysis Pass Toxic Element Migration Test Pass

Product Data Sheet for VIVIX by Formica Group. High Pressure Laminates (HPL)

Preface. Contents. 1. Description. 2. Storage and Transportation. 3. Handling and Machining of VIVIX architectural panels

Panasonic Group Chemical Substances Management Rank Guidelines Analysis Method of Level 1 Prohibited Substances

TEXTILE INDUSTRY AND ENVIRONMENT. W.J.K.Dushyanthi Ranpatige Research Officer Industrial Technology Institute

SUMMARY OF FEDERAL PRETREATMENT STANDARDS CENTRALIZED WASTE TREATMENT CATEGORY. Within U.S.: 165

FIVE STEPS TO DETOX. Ecological Services for Sustainable Chemical and Supply Chain Management

REDUCTION OF DISCHARGES AND EMISSIONS FROM THE METAL SURFACE TREATMENT 1)

Background document for sodium dichromate

TESTS / PROPERTIES. A.1.1 Carbon Steel 1. Density T-WI-CME Si & P ASTM E A.1.2 Stainless Steel 1. Density T-WI-CME

HONG KONG GREEN BUILDING COUNCIL

WA Waste Classification. Analytical Guide 2018 Update

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)

Rev. No.: 7 Page 1 of 14. Issue Date Rev. No. Summary Of Amendments 06/11/ /11/ /12/ /06/ /09/2015

Guide to green public procurement of

Waterproofing Systems

Product Data Sheet Rockpanel Brilliant

Sample Description: One (1) bottom of submitted sample said to be mixture ink for offset/pad printing. Standard : -- Ref. No. : -- P.O. No.

COOPERATIVE PATENT CLASSIFICATION

Product Data Sheet Rockpanel Chameleon

COVERINGS:WOOD AND PLANT BASED COVERINGS FINAL DRAFT CRITERIA PROPOSAL

WORKSHOP. Madrid November 21 th

Ecomark Criteria for Packaging Material/ Package

Lindner Metal Ceiling System LMD-E Environmental Product Declaration acc. to ISO Holder of the declaration

Technical Data Sheet StoSilco QS R

Technical Data Sheet StoMiral FL Vario

Transcription:

natureplus e.v. Award Guideline 0300 Issued: May 2015 for the awardance of the eco-label

Page 2 of 6 1. Application Areas The following criteria contain the requirements for the awardance of the natureplus eco-label for the following external thermal insulation composite systems. These systems are comprised of an insulation material, adhesive, fixings and a render system (base render coat with an inlaid fibreglass webbing/mesh (strengthening), primer or key coat and a finishing coat of plaster). External thermal insulation composite systems employing cork insulating boards External thermal insulation composite systems employing wood fibre insulating boards External thermal insulation composite systems employing hemp insulating boards External thermal insulation composite systems employing reed insulating boards External thermal insulation composite systems employing mineral foam insulating boards The award guideline is to be applied exclusively to those products mentioned in this guideline. 2. Award Criteria A pre-requirement for the awardance of the natureplus eco-label is the fulfilment of the Basic Criteria RL 0000. This applies to all system components except for the fixings, the fibre-glass webbing and any system accessories. 2.1 Pre-Requirements for the System Components Wood fibre insulation boards must fulfil the requirements of the award guideline RL0100 Insulation from Renewable Raw Materials and the award guideline RL0201 Porous Wood Fibre Board. The award guideline RL0201 is also to be used in the case of products with a raw density below 230 kg/m3. Hemp insulation boards must fulfil the requirements of the award guideline RL0100 Insulation from Renewable Raw Materials and the award guideline RL0101 Hemp Insulation. Insulation boards made from reeds must fulfil the requirements of the award guideline RL0100 Insulation from Renewable Raw Materials and the award guideline RL0111 Straw and Reed Based Insulation. Cork insulation boards must fulfil the requirements of the award guideline RL0100 Insulation from Renewable Raw Materials and the award guideline RL0113 Cork Insulation Boards.

Page 3 of 6 Mineral based foam insulation boards must fulfil the requirements of the award guideline RL0400 Insulation from Expanded, Inflated or Foamed Mineral Based Raw Materials and the award guideline RL0406 Mineral Based Foam Insulation. The levels of organic components within the finishing render may not exceed 7 % (inclusive silicon resins) and may not exceed a maximum of 5% in the base render and the adhesive render. The following additives/components are not permitted: Glycol ethers and -esters APEO's (Alkyl phenol ethoxylate) Formaldehyde separators/dispersers For wall paints, the following requirements apply: Preservatives may only be used for pot-preservation for retail ready-to-use liquid products. They are not permitted for film-preservation. Biocides may not be used in products which, due to their properties (e.g. highly alkaline), do not require pot-preservation. Siccatives (driers) containing cobalt are prohibited. The product must not be classified in WGK 2 or WGK 3 (Water Hazard Classes 2 and 3) according to VwVwS (Administrative Regulation on the Classification of Substances Hazardous to Waters into Water Hazard Classes) of the German Environmental Agency (Umweltbundesamt). With regard to the recommended application, the amount of anorganic white pigments of artifical origin is restricted to 38 g/m². The following substances must not be added to the product: softening agents (according to VdL-GL 01) glycol compounds APEOs (alkylphenol ethoxylates) halogenic organic compounds organic tin compounds azo dyes resulting in carcinogenic amines biocides not used for in-can conservation (film preservatives) halogenated isothiazolinones formaldehyde releasing substances Only pigments from titanium oxide, iron oxide or non-organic substances with comparable or lower toxicity levels are permitted. Pigments which are ecologically or toxicologically questionable, such as metal compounds which are forbidden as per GL-5001 are not permitted under any circumstances. The proportion of organic solvents must not exceed 0.05 M-%. The render/mortar may only contain low levels of chromates and must not display high levels of radioactivity.

The product applying for certification must comply with the emissions thresholds specified in section 3 (laboratory tests). The use of biocides for surface protection (eg. against algae growth) is not permitted. If potconservation is used, it must not be employed in amounts which imply the misuse for surface protection. Page 4 of 6 Plastic fixing plugs and accessories must be halogen-free and if available from recycled materials. 2.2 Suitability of Application An official technical approval for the whole system must be available. The European Organisation for Technical Approvals (EOTA) Guideline ETAG 004 and the Guideline for with rendering for the use on timber frame building kits CUAP 04.04./26 (Common Understanding of Assessment Procedure (CUAP)) are to be used in the technical approval and evaluation of the products. Compliance with the relevant, valid national application documents must be confirmed. The fixing plugs/anchors must comply with the relevant national requirements of the guideline ETAG 014 "PLASTIC ANCHORS FOR FIXING OF EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS WITH RENDERING. Broad-head fixings must comply with the requirements of CUAP 04.04/26. The vapour diffusion resistance number μ (according to EN 12086) of the insulating material must not exceed a value of 10. 2.3 Disposal A disposal concept must be provided for the complete system. The components must be suitable for disposal in an inert materials disposal site/facility according to the Decision of the EU council of the 19 th December 2002 on the definition of criteria and procedures for the receipt and acceptance of waste products at waste disposal sites according to article 16 and appendix 2 of the guideline 1999/31/EG. Alternatively the components must be suitable for disposal in a waste incineration plant. 2.4 Declaration The product packaging should display a full declaration of the input materials listed, analogue to the EU-Cosmetic Regulations, according to the declining mass percentage. If it is not possible to display this information directly on the product packing, it should be provided with the product in a technical datasheet or sales leaflet (in English or in the national language).

If intermediate/preliminary products or formulations are used as input substances and the proportion present in the final product is >0.1 M-%, then all the substances used within these must also be taken into account for the declaration. For naming the input materials as part of the declaration the following applies: More than 1 M-% - designation of the substance in question Less than 1 M-% - at least a functional designation (e.g. moth proofing agent ) Furthermore, it is obligatory to provide the following information in a suitable form to the consumer or user (eg. online): Instructions for use and safety precautions Indications for storage and disposal Batch numbers City/town and country of production Indication of geographical origin of the key input material Page 5 of 6 When employing components with a potential for environmental hazard, the manufacturer has to suitably indicate measures to be taken to ensure environmental protection during removal and demolition (i.e. controlled deconstruction). 3. Laboratory Tests Finishing plaster (white goods), rendering and adhesive mortars are subject to the following laboratory tests. 3.1 Element Analyses The product is subject to an element analysis to determine the content of harmful elements and to check for undesirable contaminations. The measurements have to be in compliance with the limit values. The analysis is performed according to the current version of the test method TM-02 metals. Element Limit value Unit Arsenic (As) 5 mg/kg Cadmium (Cd) 1 mg/kg Cobalt (Co) 20 mg/kg Mercury (Hg) 1 mg/kg Nickel (Ni) 20 mg/kg

Page 6 of 6 Lead (Pb) 15 mg/kg Antimon (Sb) 5 mg/kg Tin (Sn) 5 mg/kg Zinc (Zn) 150 mg/kg 3.2 Other Analyses Parameter Limit values Unit Method Chrome VI (Cr VI) 2 mg/kg TRGS 613 Halogenic organic compounds: AOX/EOX 1 mg/kg TM-03 Halo Free formaldehyde 20 mg/kg UV Vis (VdL-RL 03) TVOC 1000 mg/kg Headspace GC/MS as per E DIN 55649