Exposure Test of Fasteners in Preservative-Treated Wood

Similar documents
and corrosion in wood

Corrosion Science 52 (2010) Contents lists available at ScienceDirect. Corrosion Science. journal homepage:

treated wood Review of test methods used to determine the corrosion rate of metals in contact with Editor s Note Introduction

Electrochemical corrosion testing of fasteners in extracts of treated wood

S.L. Zelinka and D.R. Rammer USDA Forest Products Laboratory One Gifford Pinchot Dr. Madison, WI 53726

Review of test methods used to determine the corrosion rate of metals in contact with. Editor s Note. Introduction

OVERVIEW OF CORROSION PROTECTION ALLOY MP-ACQ FASTENER COATING SYSTEM FOR USE IN ACQ-PRESSURE TREATED LUMBER

Metal Roof and Wall Panel Components in Contact with Preservative Treated Lumber A position paper

Manufactured decking (composite) may be used when approved by the building department

From Laboratory Corrosion Tests to a Corrosion Lifetime for Wood Fasteners: Progress and Challenges

Technical Note SALES. Page

Unique Operational Characteristics of Creosote, Pentachlorophenol, and Chromated Copper Arsenate as Wood Pole and Cross-Arm Preservatives

EFFECT OF COLD TEMPERATURES ON STRESS-LAMINATED TIMBER BRIDGE DECKS

CONFERENCE PAPER. No. 114 (2005) Corrosion of Mild Steel, HDG Steel, and 316 Stainless Steel in CCA, CuAz and ACQ-Treated Pinus Radiata

John Ruddick Alkaline Copper Treated Wood for Residential Use. Preservative mobility in decking. Approach. Shell treated wood.

Electrochemical impedance spectroscopy (EIS) as a tool for measuring corrosion of polymer-coated fasteners used in treated wood

EVALUATION OF METAL FASTENERS CORRODED FROM CONTACT WITH PRESERVATIVE TREATED WOOD. Cary Black, Stan Choiniere, André Desjarlais, Mike Ennis

Treatability of Underutilized Northeastern Species with CCA and Alternative Wood Preservatives

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

NatureWood Construction Product Specification Guide

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems

Truss Design with Treated Lumber or Corrosive Environments

STUDY REPORT SR 244 (2011) Timber Corrosion Test Methodology. Z.W. Li, N.J. Marston and M.S. Jones

Strong-Drive SDWS TIMBER Screw

Long-Term Soil Accumulation of Chromium, Copper, and Arsenic Adjacent to Preservative-Treated Wood

MAT104: Protection Against Decay & Termites

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

Role of Construction Debris in Release of Copper, Chromium, and Arsenic From Treated Wood Structures

Building permits are not required for patios made of concrete or pavers on grade.

SECTION METAL PLATE CONNECTED WOOD TRUSSES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

USE OF PRESERVATIVE-TREATED WOOD REQUIRES CERTAIN PRECAUTIONS

Guide for Materials Selection and Design for Metals Used in Contact with Copper-Treated Wood

Design for Uplift Using TimberLOK Screws to Connect Gable Trusses to Wall Top Plates. TER No

Deck Construction Guide

Design for Uplift & Lateral Strength Using TimberLOK Screws to Connect Walls to Rim Joists. TER No

Typical Deck Details Package For One and Two Family Dwellings

MATERIAL SPECIFICATION FOR WOOD - MATERIAL, PRESERVATIVE TREATMENT, AND SHOP FABRICATION

U. S. D. A. FOREST SERVICE GEN. TECH. REP. FPL U. S. DEPARTMENT OF AGRICULTURE FOREST SERVICE FOREST PRODUCTS LABORATORY, MADISON, WISCONSIN

Study of the Effectiveness of the TIG Brush Process at Cleaning and Passivating an Autogeneous TIG Weld on 316L TWI Report 23027/1/13-2 Introduction

Selections from ANSI/TPI National Design Standard for Metal Plate Connected Wood Truss Construction

(800) fax (708) Available From: Allied Tube & Conduit Printed in U.S.A. 7/98 ATC-L

Metal Framing Channels Overview

Duration of Load on Bolted Joints

Use of a Resistance-type Moisture Meter above the Fiber Saturation Point

Moisture Meter Calibration for Untreated and ACQ-Treated Southern Yellow Pine Plywood

MATERIAL SPECIFICATION FOR WOOD, PRESERVATIVE TREATMENT, AND SHOP FABRICATION

Detailed Deck Building

Stake Tests of Northeastern Species Treated with Copperbased Preservatives: Five-Year Results

Performance of Steel Products Coated with Zinc and Zinc Alloys in Pressure Treated Wood

Prescriptive Residential Wood Deck Construction Guide

Typical Deck Details Based on the 2009 International Residential Code (Designed and Printed August 2010)

DECK PERMIT APPLICATION

Section 5 Specification 5.25 Supply of W-Beam Guardrail and Posts TABLE OF CONTENTS

Metal Finishing Products and Service META-MATE ZINCATE 40 "A CONCENTRATED LIQUID ZINCATE FORMULATION FOR THE PRETREATMENT OF ALUMINUM AND ITS ALLOYS"

Factors Affecting the Use of Increment Cores to Assess Fixation

Rotational Creep of Pallet Joint Specimens

Determination and use of moisture diffusion coefficient to characterize drying of northern red oak (Quercus rubra) *

Residential Deck Guide

Corrosion of Metals in Wood Products

SECTION SHOP-FABRICATED WOOD TRUSSES

Corrosion Resistance of Heat Exchanger Fin Materials to Potassium Hydroxide Sodium Hypochlorite-Based Cleaning Chemicals and Ammonia

BOWING IN ROOF JOISTS INDUCED BY MOISTURE GRADIENTS AND SLOPE OF GRAIN

Activated Black Magic Plus Product Code: Revised Date: 10/26/2016. Activated Black Magic Plus Black Oxide Finish for Steel

Perma-Column Deck Post Design Manual

Finishing Workshop. Acid Etch Alloy Response. Introduction 5/1/2017. Acid Etch Overview. Alloy Study Weight Loss Gloss Wall Thickness.

Sunshine Coast Regional District Section Port Facility Reparation Page 1

Preservatives and Pressure Treatment Processes for Timber

USING WOOD STRUCTURAL PANELS FOR SHEAR AND WIND UPLIFT APPLICATIONS

******************************************************************************

Observed Relationships between Wood Density and Solution Uptake during Pressure Treatment

Perma-Column Deck Post Design Manual DP4430, DP4440, DP4640, DP6630, DP6640, DP6430, and DP6440 models

Effect of drilled holes on the bending strength of large dimension Douglas-fir lumber

RAPID MACROCELL TESTS OF ENDURAMET 2304 STAINLESS STEEL BARS

TECHNICAL BULLETIN. Dissimilar Metal Corrosion in Roofing Installations

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS

STAPLE- AND NAIL- ASSEMBLED PALLETS UNDER IMPACT LOADING

Prescriptive Residential Wood Deck Construction Guide Based on the 2012 International Residential Code

POST FRAME BUILDING STANDARDS

OPTIMIZING HOT DIP GALVANIZING OPERATIONS OF STEEL SHEETS FOR BETTER QUALITY

Contents TABLE OF CONTENTS: 2008 AWPA BOOK OF STANDARDS. AMERICAN WOOD PROTECTION ASSOCIATION 2008 All Rights Reserved. Introduction Page 1

A. Meet at Project site <insert number> days before starting installation.

FastenMaster FlatLOK Fasteners TER No

FACT SHEET #2 DECK INFORMATION

PART 1 GENERAL SHOP FABRICATED WOOD TRUSSES

STAINLESS STEEL. Useful Information

Stainless Steel & Stainless Steel Fasteners Chemical, Physical and Mechanical Properties

The Modern Timber Bridge Program in the State of Maine: A Five-Year Report

ESR-2604* Reissued January 1, 2011 This report is subject to renewal in two years.

REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: September 14, 2012 REVISED DATE: N/A

Study of the Effectiveness of the TIG Brush Passivating an Autogeneous TIG Weld on 316L TWI Report 23027/1/13-2. Process at Cleaning and

Black Magic Infusion Powder Product Code: Revised Date: 07/18/2016. Black Magic Infusion Powder

CITY OF FRUITLAND DIVISION OF PLAN REVIEW & PERMITTING DECK GUIDE. This design guide assumes all lumber to be pressure-treated Southern Pine.

An Overview of the U.S. Wood Preserving Industry

of the new, broadly permissible ACQtype

Moisture Content Specific Gravity Relationships for Clear Southern Pine

THE INTERNATIONAL RESEARCH GROUP ON WOOD PRESERVATION CURRENT AND FUTURE OPTIONS FOR MANAGING USED PRESERVATIVE-TREATED WOOD

DIMENSIONAL CHANGES IN KILN-DRIED SOFTWOOD LUMBER AFTER SURFACING AND DURING STORAGE

SURFACE TEMPERATURE AS AN INDICATOR OF WOOD MOISTURE CONTENT DURING DRYING

AMERICAN INSTITUTE OF TIMBER CONSTRUCTION AITC

Finishing Wood Decks

Transcription:

Summary Exposure Test of Fasteners in Preservative-Treated Wood Samuel L. Zelinka Materials Engineer USDA Forest Products Laboratory Madison, WI USA Douglas R. Rammer Research General Engineer USDA Forest Products Laboratory Madison, WI USA This study examined nails and screws exposed to ACQ-treated wood for up to 12 months in a controlled environment. The environment (27ºC, 100% relative humidity) was chosen so that comparisons could be made with previous exposure tests run using CCA-treated wood in the same environment. Five types of fasteners (common 8d nail, hot-dipped galvanized 8d nail, 4d aluminum alloy nail, 64-mm electroplated galvanized screw, 64-mm stainless steel screw) were inserted into wood treated with ACQ to a retention of 4 kg m 3 and exposed to a 100% relative humidity environment for periods from 1 to 12 months. The fasteners were cleaned and weighed to quantify corrosion rate. 1. Introduction and Motivation Because of the voluntary withdrawal of chromated copper arsenate (CCA) for residential use, many designers are now choosing wood treated with alternatives to CCA, such as alkaline copper quaternary (ACQ) and alkaline copper azole (CuAz). Published research on the effect of alkalinebased preservatives on corrosion rate is limited, although ACQ and other new preservatives are generally believed to be more corrosive that CCA (Zelinka and Rammer, 2005). Although electrochemical test methods show great promise for rapidly evaluating corrosion of metals in contact with wood, they need to be validated by real-world exposure data. The 27ºC, 100% relative humidity condition has been used by several researchers to evaluate the corrosion of metals in CCA- and zinc-chloride-treated wood (Baker, 1992; Simm and Button, 1985). Furthermore, Baker (1992) showed that corrosion rate of fasteners in CCA-treated wood is constant for exposure times of 1 to 17 years in this environment. For these reasons, this environment was chosen to evaluate the corrosion of fasteners in ACQ-treated wood. 2. Experimental 2.1 Lumber Select structural grade Southern Pine boards, 100% heartwood, nominally 50 by 100 mm, and treated with ACQ, were purchased from a commercial supplier. The wood was selected so that grain angle was approximately tangential to the 50-mm face. The ACQ-treated lumber was intended for use aboveground according to American Wood Preservers Association use category UC3 B (AWPA, 2005) and had a specified nominal retention of 4 kg m 3. The exact ACQ type and formulation were not specified on the commercially purchased lumber. Before the test began, the wood was equilibrated in a room at 27ºC, 90% relative humidity

2.2 Environment and time of exposure The 100% relative humidity environment was created in sealed glass desiccators that were partially filled with water, allowing water and water vapor to be at equilibrium. The temperature was kept constant by placing the desiccators in a conditioned room at a constant 27ºC. Assuming uniform corrosion, the measured corrosion rate should be constant, regardless of the exposure time. To determine if shorter exposure times could accurately predict corrosion rate, tests were run for periods of 1, 2, 3, 6, 9, and 12 months. 2.3 Fasteners Five types of fasteners were tested: a common 8d nail, a hot-dipped galvanized 8d nail, a 4d aluminum alloy (UNS AA5056) nail, a 64-mm electroplated galvanized screw, and a 64-mm stainless steel screw. 2.4 Pre-Exposure Procedure Prior to insertion into the wood, the fasteners were cleaned, degreased, and weighed. The fasteners were cleaned in a three-step process: soaked in ultrasonically agitated soap solution for 5 min; rinsed under flowing distilled water; soaked in ultrasonically agitated distilled water bath for 5 min. The fasteners were degreased by rinsing with a 50/50 mixture of toluene and ethanol and again rinsed with distilled water. The fasteners were then allowed to dry, weighed to the nearest 0.1 mg, and driven on the 50-mm face of the wood into predrilled 2.26-mm-diameter holes to prevent wood splitting and ensure uniform contact between the nail surface and the wood. The predrilled hole corresponds to approximately 90% of the diameter of the smallest fastener. The fasteners were each driven into a separate piece of wood to prevent cross contamination between fasteners. 2.5 Post-Exposure Procedure The fasteners were removed in such a way to minimize damage to the fastener. Initially, two grooves were cut in the wood surrounding the fastener with a band-saw. The wood was then placed in a vise. As pressure was applied, the wood split along the sawn grooves, and the fastener was removed without damaging the corrosion products. Several high-resolution digital images of each fastener were recorded to visually document the amount of corrosion products. Black and white photographs taken under special lighting recorded a silhouette of each fastener. The fasteners were then cleaned using methods similar to those presented in ASTM G1-03 (ASTM, 2003). After cleaning, each fastener was weighed and the mass (m f ) was measured. Weight loss due to cleaning (m c ) was calculated by using the same cleaning and weighing process on uncorroded fasteners (Table 1). TABLE 1 Cleaning methods used to remove corrosion products Cleaning Weight change Standard time a due to cleaning deviation Material Solution (min) (mg) (mg) Steel and 50/50 mixture of distilled water 60 1.2 0.9 stainless steel and Evapo-Rust b Galvanized Saturated ammonium acetate 60 1.6 1.2 Aluminum Concentrated nitric acid 5 +0.1 0.2 a Cleaning was performed with ultrasonic agitation. b Evapo-Rust is a proprietary chelating agent manufactured by Harris International Laboratories, Inc, Springdale, Arkansas. m c σ mc

90 80 70 Galvanized Nail Aluminum Nail Stainless Steel Screw Carbon Steel Nail Galvanized Screw Corrosion Rate (µm/year) 60 50 40 30 20 10 0 Figure1 Results of corrosion tests conducted in a 27ºC, 100% relative humidity environment. Values represent the average of 9 replicates, which were exposed for times between 6 and 12 months. Error bars represent one standard deviation. The silhouette photographs were analyzed using a computer program written by the authors to compute surface area of the fastener, which was used for corrosion rate calculations. This program contained an algorithm, also written by the authors, to compute the surface area of a threaded fastener with given thread characteristics. Ideally, the pre-test surface area should be used in corrosion rate calculations; however, no silhouette photographs were taken prior to insertion, so post-test surface area was used in corrosion rate calculations. 3. Results Previous researchers reported their data as percentage mass loss, which can be misleading if comparing fasteners with different densities. A more informative figure is corrosion rate, which was calculated from the familiar equation R = K m f m i + m c [1] Aρ(t f t i ) where m i and m f are initial and final masses (g), t i and t f are initial and final times (h), A is surface 3 area (cm 2 ), ρ is density(g/cm ) tabulated in ASTM G1-03 (ASTM, 2003), and K is a constant (87,600 mm cm -1 h year -1 ). The term m c (g) was added by the authors to represent the additional loss of base metal that results from removing the corrosion products. Assuming uniform corrosion and a constant corrosion rate (as reported by Baker (1992)), the corrosion rate should be the same regardless of exposure time. However, Zelinka (in press) showed that uncertainties in corrosion rate measurements decrease with time and that uncertainty is less than 5% for these alloys after 6 months in this environment. Therefore, the data (Fig. 1) represent the average of the corrosion rates collected at 6, 9, and 12 months. Error bars represent one standard deviation above and below the mean. The uncertainty in the measurements is small, but standard deviation is large. (Uncertainty inversely reflects accuracy

of the measurements; standard deviation reflects range and variability of the measurements.) Standard deviation may be so high because there were so few (9) replicates. 4. Discussion The most surprising result is that the electroplated galvanized screw outperformed the hot-dipped galvanized nail. Several researchers have shown the corrosion performance of hot-dipped galvanized fasteners to be superior to that of electroplated galvanized fasteners in the CCA-treated wood environment (Wallin, 1971; Baker, 1992). The most likely explanation for this dramatic difference is that the alloying elements in the galvanizing process were different. It should be noted that as of this time, no metallurgical analysis has been completed on the fasteners or their coatings. The electroplated galvanized screw may have had a chrome conversion coating, whereas the hotdipped galvanized fastener did not. In short, more research needs to be done to determine the affect of the metallurgy of the fastener on its corrosion performance in treated wood. 5. Conclusions This report contains data on the corrosion rate of fasteners exposed to ACQ-treated wood in a 27ºC, 100% relative humidity environment. Corrosion rate was hypothesized to be sensitive to the alloying elements in the galvanizing coating. Before these data can be compared with previous research conducted using CCA-treated wood, the data in those reports need to be converted from percentage weight loss to corrosion rate. The authors are currently working with photographs in those reports in conjunction with their algorithm to make this comparison. 6. References [1] Zelinka, S., Rammer, D. 2005. Review of test methods used to determine the corrosion rate of metals in contact with treated wood. Gen. Tech. Rep. FPL-GTR-156. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory. 23 p. [2] Baker, A. J. 1992. Corrosion of nails in CCA and ACA treated wood in two environments. Forest Products Journal, Vol. 42, No. 9, pp. 39-41. [3] Simm, D., Button, H. 1985. Corrosion behaviour of certain materials in CCA-treated timber. Environmental tests at 100% relative humidity, Corrosion Prevention and Control. Vol. 32, No. 2, pp. 25-35. [4] AWPA 2005. Use category system: User specifications for treated wood. American Wood Preservers Association, Selma, Alabama. [5] ASTM. 2003 Standard practice for preparing, cleaning, and evaluating corrosion test specimens. ASTM G-1-03. West Conshohocken, PA: American Society for Testing and Materials. [6] Zelinka, S.L. 200X. Uncertainties in Corrosion Rate Measurements of Fasteners Exposed to Treated Wood at 100% Relative Humidity. ASTM Journal of Testing and Evaluation (Submitted for Publication). [7] Wallin, T. 1971. Corrosion of fasteners in treated wood. Sixth Scandinavian Corrosion Congress; Gothenburg, Sweden. 13 p.

In: WCTE 2006-9 th world conference on timber engineering; 2006 August 6-10; Portland, OR, Corvallis, OR: Oregon State University: 4 p. On CD

In: WCTE 2006-9 th World conference on timber engineering; 2006 August 6-10; Portland OR., Corvallis, OR.; Oregon State University: 4 p. Available on CD