Field test at Gehrkescher Hof in Wilmshagen/Germany

Similar documents
Field-test at Betonstal Sp. z.o.o. Szczecin/ Poland

ODOR PREVENTION AND CONTROL IN SANITATION. Tuula Tuhkanen Department of Chemistry and Environmental Engineering Tampere University of technology

Field-tests at Kiviõli Keemiatööstus OÜ oil-shale processing plant in Kiviõli, Estonia

Plasma-based cleaning of exhaust gases of combustion Plasma based cleaning of exhaust gases of combustion(wp4)

Real-time analysis of VOCs in human breath, using SIFT-MS

Analysis of hexadecane decomposition by atmospheric microplasma

Attracting investments in plasma-based air and water cleaning technologies, PlasTEP+

Laboratory-Scale Investigation of UV Treatment of Ammonia for. Livestock and Poultry Barn Exhaust Applications

CONTINUOUS EMISSION MONITORING SYSTEM. Copyright Adage Automation Pvt Limited

A Single Analyzer Solution for Refinery Flare Emissions Monitoring (40 CFR 60 Subpart Ja) Using Mass Spectrometry

Dissemination and fostering of plasma based environmental technological innovation

Issues around field measurements with electronic noses : low concentration and specificity of odorous compounds Jacques NICOLAS Julien DELVA -

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic

PROCESS ANALYZERS FOR PURIFIED BULK GAS QC/QA: ENTERING THE PPT RANGE

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

What Does the Future Hold for Ambient Air Monitoring Regulations?

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

This document is a preview generated by EVS

Plasma based VOC reduction PlasTEP (+) results

Plasma based VOC reduction PlasTEP (+) results

ENVIRONMENTAL MONITORING OF EMISSIONS FROM PAINT MANUFACTURING PROCESS

Solvent degradation Grégoire Léonard

Techniques for Measuring Oil in Water

Trace Moisture Contamination in Ultra-High Purity Phosphine: Techniques for Measurement and Control

D DAVID PUBLISHING. Hydrogen Gas Purifiers for Fuel Cells. 1. Introduction. 2. Scientific Approach

TDLAS. Application Note. Tunable Diode Laser Absorption Spectroscopy (TDLAS) for Carbon Dioxide Measurements In Natural Gas Processing

Chevron Richmond Refinery Fence Line and Community Air Monitoring Systems

De-ionized water. Nickel target. Supplementary Figure S1. A schematic illustration of the experimental setup.

Dr. Jens Herbig - CTO

INDUSTRIAL EMISSION MONITORING: METHODS AND EMERGING TECHNIQUES

33101 TAMPERE.

Utility of Variable Bandwidth Monochromators for Quantification of Fluorescent Probes in Produced Effluent Water

Technical TFTEI meeting of 24 June Agenda

Hydrogen Production by Non Thermal Plasma Steam Reforming of alkanes and ethanol

What is molecular filtration?

9F, No. 7, Lane155, Sec3, Peishen Road, Shen Keng Hsiang, Taipei Hsien, Taiwan Tel: Fax:

Greenhouse Gas Measurement Technology

EFFECT OF GAS-PHASE ALKALI ON TAR REFORMING CATALYST

Application Note. Hydrogen Purity Analysis by FTIR PROBLEM BACKGROUND

Hydrogen fuel Product specification. Part 2:

QUALITY ASSURANCE OF EMISSION MEASUREMENT

SIFT-MS: A Significant New Tool for Real-Time Air Quality Monitoring

MEGA evaluations for the preparation of REACH exposure scenarios for octamethylcyclotetrasiloxane

Report no Measurement of emissions from aluminium foundry. Lennart Holmberg and Martin Wänerholm

EDX 600. Atomic Absorption Spectrometry

Trace PRODUCT NOTE

Fully Extractive Vs. Dilution Extractive CEMS

Final Exam. Physical Constants and Conversion Factors. Equations

INDUSTRIAL MEASUREMENTS USING FTIR GAS ANALYZER

Project Summary Report

Dissemination and fostering of plasma based environmental technological innovation

AXPC Manual Tank Gauging. Presented by Chad Hyman

Carbonyl compounds and VOCs analysis from vehicle exhaust: Conventional and alternative methods of detection, analysis and quantification

Co-Combustion of Wood and Straw in a Circulating Fluidized Bed Boiler reduction of NO x emission

Measurement of composite surface contamination using the Agilent 4100 ExoScan FTIR with diffuse reflectance sampling interface

Monitoring and impacting gaseous emissions in post combustion carbon capture

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

LABORATORY á SCALE APPARATUS TO ASSESS FEASIBILITY OF SOIL VENTING PROJECTS Application at the Jet-Fuel Polluted Air Base

Odours and their effects on residents - How to measure and regulate odour impact

EXPERIMENTAL INVESTIGATION OF NITROGEN DIOXIDES ADSORPTION FROM CABIN AIR BY ACTIVATED CHARCOAL AIR FILTERS

Principles of plasma based VOC reduction

Control Solutions During Manual Tank Gauging. Chad Hyman SRP Environmental

Solutions. Integrated Analyzer Systems & Services. Your Global Partner For Customized Analytical Solutions

03. EXTERNAL AND INTERNAL PLASMA-ASSISTED COMBUSTION

Using energy substances as a way to enhance oil recovery

Air Quality (VOC) Transmitters for Duct Mounting. Features. Ordering QDT QDT S QDT D

Gas Filtration Catalogue

AIR QUALITY ASSESSMENT FOR TAYLOR STANLEY MARKETING PTE LTD 71, TANNERY LANE #-7-07, CITY INDUSTRIAL BUILDING SINGAPORE

Historical Review: Fast & micro Gas Chromatography

Process Analytics Using Quantum Cascade Laser

Chlorinated DNAPL Identification using the Membrane Interface Probe (MIP)

Carbon Black At-line Characterization. Using a Portable Raman Spectrometer

Fact Sheet SP3: Odour measurement and assessment, evaluation of odour treatment technologies

DRAINING OF SLURRY PITS - A SIMPLE WAY TO REDUCE EMISSIONS FROM PIG HOUSING UNITS

ABE 482 Environmental Engineering in Biosystems. November 14 Lecture 30

Hydrogen Production from Hydrogenated Liquids Compounds by a Nonthermal

Olefin Analyzer Solutions for Polymer Grade Ethylene and Propylene

Indoor Air Quality Solutions

Mach-RGA. The Fast Refinery Gas Analyzer. Analyzer

Chambers and Instrumentation CHAMBERS. STORA: 22 m 3 chamber

SPECTROSCOPIC METHODS FOR VOCs DETERMINATION

Recent developments on quality assurance of fuel cell hydrogen

VERA Test Protocol for Covers and other Mitigation Technologies for Reduction of Gaseous Emissions from Stored Manure

Ozone and by-products generation characteristics by novel air-fed ozone generator which combines homogeneous discharge and filamentary discharge

High temperature in-situ IR laser absorption CO-sensor for combustion control

Meet Ja, H2S, and BTU flare regulations while reducing your total cost of ownership

Practical Odour assessment. Nigel Gibson

Chemical Analysis of Molten Salts Before and During Use in a Test Loop by Flame Atomic Absorption Spectroscopy

Turnkey configurations for gas chromatographic analysis, including instrumentation, methods, supplies and service. Analysis of Natural Gas

Odour modelling using ADMS software

EuroFID Total Hydrocarbon Analyzer

Odor Basics & Reducing Technologies

APPLIED. Measuring Odorants in Natural Gas Pipelines. Application Summary. Analytes: Odorants (i.e. mercaptans, thiophenes)

Re: Casey Middle School at 1301 High Street in Boulder, Colorado Follow-Up Indoor Air Quality Monitoring (Hydrogen Sulfide)

Hydrogen Generators for Fuel Gas

Continuous Emissions Monitoring in Support of the Cement MACT

Supplemental Information. A Visible and Near-Infrared, Dual-Channel. Fluorescence-On Probe for Selectively. Tracking Mitochondrial Glutathione

Lab 6 Measurement of Ozone

R. L. Aggarwal, L. W. Farrar, S. Di Cecca, and T. H. Jeys. MIT Lincoln Laboratory, Lexington, MA

Speaker Biography. Matthew DeVay Quality Assurance Director Trace Analytics

Transcription:

Field test at Gehrkescher Hof in Wilmshagen/Germany M. Schmidt, R. Brandenburg Executive Summary A field test was performed in order to investigate the feasibility of the treatment of agricultural exhaust air by means of plasma technology. The plasma source, the power supply and the sensitive analytical devices were successful applied and operated but the concentrations of the impurities were too small to get reliable statements about the conversion of pollutants Introduction The agricultural holding Gehrkescher Hof locates between Stralsund and Greifswald in the North-Eastern part of Germany and runs, besides others, pig breeding. This is connected to the production of exhaust air contaminated with bad smelling compounds. Important components of the exhaust air of pig breeding sites air smells and ammonia [1]. The removal of these components by means of plasma-based technology was the aim of the herewith reported field test. Experimental procedure In Figure 1 the exhaust duct of the ventilation system is shown together with the flexible tube leading the sample gas to the experimental setup. The experimental setup used is schematically depicted in Figure 2. The exhaust air was sucked from the ventilation system of the hog house through the plasma source by means of a ventilator. Sample probes were extracted from the exhaust air stream and directed to an FTIR-spectrometer (Fourier-Transform Infra-Red-spectrometer) as well as an FID (Flame-Ionization-Detector). To protect the sensitive diagnostic equipment from damage appropriate filters were installed. The data of the gas analysis were stored on a computer in realtime. The plasma source was operated with a programmable high-voltage (HV) power source. The electrical operation parameters were investigated by a digital oscilloscope and voltage and current probes. 1 of 5

Figure 1: Exhaust duct of the ventilation with flexible tube for sample gas Figure 2: Scheme of the experimental setup 2 of 5

Results Unspecific bad smells are often recognized due to the presence of volatile organic compounds (VOC`s). In this field test an FID was used to analyze the concentrations of the VOC s. The results of these measurements are shown in Figure 3. The black curve displays the value of the hydrocarbon-bonded carbon atoms in ppm (parts per million) measured with the FID. The red curve correlates with the specific energy density (SED), which is calculated by the division of the power dissipated into the plasma and the according gas flow. The values displayed fluctuate around a value of about 12 ppm. A reliable correlation with the applied energy density cannot be drawn. Only a clue for the VOC-removal by plasma can be found in the area light gray marked. Here, a significant decrease of the VOC-concentration is to be found shortly after the application of the highest energy density. However, reliable, qualified statement about the feasibility of plasma-based technology for VOC-removal in agricultural exhaust air cannot be concluded from this results. Figure 3: FID-display (black curve) and correlating specific energy density (SED, red curve) 3 of 5

Since the contaminationn of the exhaust air from pig breeding with bad smelling compounds besides VOC s also is due to the presence of ammonia, the analysis of the recorded infrared spectra was focused on this compound. A representative example is given in Figure 4. The black curve corresponds with the absorption of the components present in the investigated gas mixture. The red curve correlates with the absorption of the ammoniaa reference. Obviously, in the spectral region related to ammonia absorption there are no absorption bands detectable in the spectrum of the exhaust air, although the smell of ammonia was recognized by all participants of the experiments. The lack of these absorption bands is thought to be due to the small threshold for odour recognition of ammonia, which is given by Smeets et.al. with 2.6 ppm [2]. The infrared absorption of a component with this concentration is so small that it is not detectable in an infrared spectrum. In the spectrum of the analyzed gas mixture significant absorption bands are detectable in the spectral range between 1000 and 1075 cm -1. These absorption show the presence of ozone. Ozone is the main stable component produced by a plasma operated in air. The presence of ozone shows clearly that the plasma source operates as expected. Figure 4: Sample of the infrared spectrum of the analysed exhaust air (black) and reference spectrum of ammonia (red) 4 of 5

According to the owner of the pig breeding site also hydrogen sulfide emissions contribute significantly to the smell nuisance. Therefore, the recorded infrared spectra were investigated for absorption bands of hydrogen sulfide. In the relevant spectral ranges no absorption bands could be detected. This also is thought to be due to the small threshold for the odour recognition of hydrogen sulfide, which is with values below 1 ppm and thus even smaller than that of ammonia [3]. Summary During the performed field test the mobile plasma system and the diagnostic equipment were installed and operated successfully. Since the threshold values for the recognition of the bad smelling compounds are quite small, these components could be smelled by participants of the experiments but neither detected with the FTIR-spectrometer nor with the FID. Therefore, for the diagnostic of agricultural exhaust air the diagnostical apparatus used is not applicable. For the detection of trace gases in the sub-ppm-range the application of laser-based infrared spectroscopy (e.g. Q-MACS trace) or mass spectrometry based gas chromatography (GC-MS) should be taken into account. Because of the high amount of exhaust air to be treated a cyclic process should be taken into account to ensure the economic efficiency of the exhaust air treatment system. In this process the impurities are collected in an adsorber, which is cyclical regenerated by a plasma application. The regeneration of loaded adsorbing material should be tested in additional experiments. References [1] Thüringer Landesanstalt für Umwelt und Geologie, Emissionen von Ammoniak und Staub aus Tierhaltungsanlagen, online verfügbar unter: http://www.tlugjena.de/umweltdaten/umweltdaten2007/luft/pdf/emissionen_tierhaltungen.pdf [2] Smeets M.A.M., Bulsing P.J., van Rooden S., Steinmann R., de Ru J.A., Ogink N.W.M., van Thriel C. & Dalton P.H., Odor and Irritation Thresholds for Ammonia: A Comparison between Static and Dynamic Olfactometry, Chem. Senses, 2006 [3] H 2 S Safety Factsheet, online verfügbar unter: http://www.safetydirectory.com/hazardous_substances/hydrogen_sulfide/fact_sheet.htm 5 of 5