Fast Track Re-Roof Permit Checklist

Similar documents
Fast Track Residential Re Roof Permit Checklist

RESIDENTIAL ATTACHED CARPORTS BUILDING PERMIT REQUIREMENTS

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

Residential Building Inspections

INDIANA COUNTY Office of Planning and Development 801 Water Street Indiana, PA (724) Fax (724)

SUBMITTAL REQUIREMENTS FOR SINGLE FAMILY DWELLINGS

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

Roofing City of Owatonna BUILDING DEPARTMENT

*Secondary suites must be provided with independent heating and ventilation system, separate from the main dwelling unit.

SUBMITTAL REQUIREMENTS FOR EXPEDITED ROOF TOP SOLAR PERMITTING

FORTIFIED Home High Wind. Bronze New Roof Requirements

One and Two Family Additions

I. Process. Table of Contents. I. Process. II. Additional Information

RESIDENTIAL/COMMERICIAL ROOFING APPLICATION Date / / BUILDING PERMIT APPLICATION

A.ENVELOPE AIR SEALING

WILL COUNTY LAND USE DEPARTMENT 2018 CONTRACTOR REGISTRATION

BUILDING EXTERIOR SHELL TRAINING

*FOR RESIDENTIAL PROJECTS, CALL JACK CARNS AT *FOR COMMERCIAL PROJECTS, CALL BRIAN WRUBLE AT

APPLICATION FOR FINISHED BASEMENT PERMIT

Minimum Residential Plan Submittal Requirements

Applying for Permits to build a new house in Linn County

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

CITY OF CITRUS HEIGHTS BUILDING & SAFETY DIVISION

ATHENS TOWNSHIP ROOF PERMIT APPLICATION

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide

CITY OF OAK CREEK SINGLE FAMILY & TWO-FAMILY CONSTRUCTION/PERMIT REQUIREMENTS

PATIO COVERS BUILDING PERMIT REQUIREMENTS

APPLICANT IS THE: OWNER CONTRACTOR SITE ADDRESS: CITY STATE/ZIP

Proud of its Heritage, Preparing for its Future

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

RESIDENTIAL REMODELING AND BASEMENT FINISH

Residential Building Plans

* RESIDENTIAL PLAN REVIEW *

Natrona County Development Department 200 North Center Street, Room 205 Casper, WY Phone: Fax:

BUILDING PERMIT APPLICATION

Residential Building Permit Application Note: Storm Water Permit may be required.

Application for Commercial Plan Review and Building Permit. Address:

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

$ Plan Review Fee when Permit Application is submitted BASEMENT REMODEL BUILDING PERMIT APPLICATION. Status Sticker OFFICIAL USE ONLY

ONE AND TWO FAMILY DWELLING PERMIT APPLICATION REQUIREMENTS

COMMERCIAL RE-ROOF BUILDING PERMIT GUIDE

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations

Township Of Blandford-Blenheim Permit Guide

ROOF MITIGATION STRUCTURE EVALUATION FORM. For Single Family Residential Re-Roof Effective October 1, 2007 (Revised February 2, 2018)

9) Home Inspection: As defined in Section 1-10 of the Act.

TITLE 68: PROFESSIONS AND OCCUPATIONS CHAPTER VIII: DEPARTMENT OF FINANCIAL AND PROFESSIONAL REGULATION

Town of Pawling Residential Building Permit Application

Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue Oroville, CA Office (530)

Garage/Accessory Structures

Alabama Home Inspections

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017

Permit Procedures For New Construction, Additions, and Alterations

Section Standards of Practice. a) The following are terms commonly used in the writing of home inspection reports.

CLEAR CREEK COUNTY BUILDING DEPARTMENT REQUIREMENTS FOR A SINGLE FAMILY RESIDENCE

Streamline Solar Photovoltaic Structural Criteria for Residential Rooftop Solar Energy Installations (Streamline Solar Form 5)

The Inspection Process. Waxhaw N.C.

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Town of Pawling Residential Building Permit Application

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Elko County Building & Safety Division

Structural Criteria for Residential Rooftop Solar Energy Installations

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

Building Department Informational Handout. Residential Window Replacement Requirements

The CornerStone Cottage Series

Township of Georgian Bluffs. Building Permit Information

UCC Permit Application Procedures

MAGNUM. I N S P E C T I O N S Inc. ROOF Walked on roof, crawled attic where accessible.

Solar Photovoltaic System Permit

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

Town of Atkinson, New Hampshire INVITATION TO BID. Town Garage Roof Replacement Issued: June 30, 2015

CITY OF TROY, MISSOURI Building Permit Application. Type of Permit: Residential Commercial. Company: Contact person: Address # Street Name:

This permit is issued under OAR Permits expire if work is not started within 180 days of issuance or if work is suspended for 180 days.

HOUSE ADDITIONS A guide to the plans required when applying for a Building Permit

Municipal Services Agency Building Inspection General Information: (916)

*FOR RESIDENTIAL PROJECTS, CALL JACK CARNS AT *FOR COMMERCIAL PROJECTS, CALL BRIAN WRUBLE AT

REPORT CHECKLIST SUPPLEMENT

3D Home Improvement and Inspection Services, Inc

Roofing Policy for Commercial Buildings

2003 International Residential Building Code

1. Complete Building Permit Application forms on page 2. Include septic system design approval from the Washington County Health Department.

Repair or replace section of driveway, approach, or sidewalk that are a trip hazard.

Home Remodeling Code Violations

Building Guide. Colorado Chapter of the International Code Council

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Residential Building Permit Application

DATE:6/18/2013 INSPECTOR: ELEVATION

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

Commercial Remodel Permit

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

Requirements for Additions/Enclosed Deck/Finished Bonus Room/Dormer

BUILDING PERMIT APPLICATION PACKAGE

RESIDENTIAL BUILDING REQUIREMENTS

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

Transcription:

Fast Track Re-Roof Permit Checklist ADDRESS I will abide by attached City Re-Roofing Building Permit Required Guidelines, including applicable Siding and Roofing Match and Smoke Detector requirements. Attached is insurance company scope of work and/or contractor s contract. I will schedule exposed decking inspection with City upon removal of shingles and underlayment (felt) Ice and water shield and drip edge are required. I, (Name) (Company) (Address) (Phone) I certify information provided is true and re-roof work will meet CITY of HAZELWOOD Re-Roofing Building Permit Required GUIDELINES Date Signature Revised November 16, 2016

City of Hazelwood Building Permit Please COMPLETE ALL INFORMATION or APPLICATION will not be ACCEPTED DATE VACANT RESIDENTIAL Yes or No (circle one) TYPE OF CONSTRUCTION: NEW COMMERCIAL (NC) COMMERCIAL ADDITION (CA) COMMERCIAL RENOVATION (CR) NEW RESIDENTIAL (NR) RESIDENTIAL ADDITION (RA) RESIDENTIAL RENOVATION (RR) FIRE REPAIR (FD) FIRE PROTECTION (FP) MECHANICAL (M) RE-ROOF (R-R) DECK ADDITION (DA) GARAGE (G) UTILITY (U) PATIO COVER / ENCLOSURE (P) STORAGE BUILDING (ST) 415 Elm Grove Lane Hazelwood, Missouri 63042 Phone: 314-513-5033 Fax: 314-839-0249 REQUIRED DOCUMENTS SITE PLAN CONTRACT/TOTAL COST CONSTRUCTION PLANS All Commercial/Industrial 4 SETS ORIGINAL CITY 3 SETS ANNEXED AREAS All Residential - 2 SETS DESCRIPTION OF CONSTRUCTION ADDRESS OF CONSTRUCTION Total Cost of Construction $ (COPY of CONTRACT REQUIRED) GENERAL INFORMATION Owner of Property Address/City/Zip Phone Architect/Engineer Address/City/Zip Phone Contractor Address/City/Zip Phone *Signature Owner/Agent (Printed Name) Address/City/Zip Phone *My signature certifies all of the above information is Accurate DO NOT WRITE BELOW THIS LINE # OTHER REQUIRED PERMITS Inspections: Fire Jurisdiction St Louis County Pier/Footing Hazelwood FD Electrical Foundation Florissant FD Plumbing FEE INCLUDES INSPECTIONS Frame Robertson FD HAZELWOOD FIRE PERMIT Drywall AND PLAN REVIEW: Special Inspections Licensed Mechanical Contractor Construction Final Occupancy Inspection TOTAL FEE REVISED November 16, 2016

Re-Roofing Guidelines Building Permit Required November 16, 2016 City of Hazelwood adopted the 2009 International Residential Code A Building Permit is required for all Residential re-roofing projects No Repairs, No Partial or No Half Re-Roofs Allowed City Permit Inspections Sheathing inspection after shingles and underlayment (felt) has been removed. Proper installation of ice and water shield and H clips (if necessary) underlayment (felt), flashing and drip edge Final upon completed re-roof Code Considerations and Requirements for Residential Re-Roofing: The plywood sheathing is part of the structural lateral restraint system and is a essential element. If plywood has the incorrect span rating or is not attached properly, it can affect structural stability of the structure. (Recommended Minimum thickness 7/16 OSB) Sheathing shall be inspected for thickness, structural integrity and APA rated span. If replacement is required, the building inspector will advise the APA rated panel required based on spacing of trusses or rafters. Replaced plywood should be fastened with a minimum of 8d common nails or 16ga staples (1-3/4 long with a 7/16 crown). Fastener spacing shall be 6 oc. at panel edges and 8 oc. in the field. H clips are required on spans of 24 and additional fasteners may be required for lateral loads. Ice and Water Shield is required. Ice and water shield shall extend from the lowest roofs eaves edge to a point a minimum of 4 measured horizontally to a point being the interior of the exterior wall, (usually a minimum of two (2) rows) Metal Drip Edge is required. Metal drip edge shall be applied to the perimeter of the roofs exposed edges. Metal drip edge shall be placed over the roof felt on the gable/rake edges and under the Ice and Water shield on the eave edges. The roof slope will determine the roof covering material requirements. The normal installation of composition shingles are for roof with a slope of 4:12 or greater. For roof slopes less then 4:12 check the manufacturer s installation guidelines found on each bundle of roofing A maximum number of two (2) layers are allowed. The maximum number of layers for a composition shingle roof is two (2) A maximum number of one (1) layer of decking is allowed. The maximum number of layers for roof sheathing is one (1) Flashing shall be properly installed. Flashing helps prevent water from entering the building and varies depending on the roofing material. Valleys, sidewalls and other intersection of the roof and vertical or different plane surfaces all require flashing. Check the manufacturer s installation guidelines found on each bundler of roofing. Metal, 30# underlayment and/or Ice and Water shield are several of the products that can be used. All chimneys impeding water shed will require a cricket.

Underlayment (tar paper/ felt) shall be properly lapped. Minimum of one (1) layer of 15# underlayment is required. The underlayment should be lapped 4 at the vertical seams and 2 at the horizontal seams. Special installation requirements are required on roofs that slope less than 4:12. Check the manufacturer s installation guidelines found on each bundle of roofing material. Roof ventilation shall provide minimum ventilation requirements. Ventilation of the roof is required to help prevent damage from water vapor and condensation within the attic space. Roof ventilation should be calculated at rate of 1 sq. ft. of net vent area for every 150 sq. ft. of roof area. Each roof vent will have the total amount of area the vent will provide. Proper ventilation should be verified when new roofing materials are installed, All clothes dryer, bathroom and kitchen exhaust fans ducted through the attic shall extend to the exterior or to a dedicated roof vent. Exhaust vented through the attic must be vented to the exterior or connected to a dedicated roof vent to assure exhausted air is vented to the exterior. During the removal of the existing roofing material dedicated roof vents are sometimes disconnected from the venting duct and are required to be reconnected. Roofing material shall be installed per the manufacturer s specifications and per the 2009 International Residential Code. Each bundle of roofing material comes from the manufacturer with the installation requirements. These installation guidelines are typically code compliant. If shingles are not installed per the specifications, the warranty of the roofing maybe voided. Recovering versus replacement of roofing. Wood shakes, slate, clay, cement or asbestos-cement tiles are required to be removed. Recovering of composition single materials is permitted provided there are not more than two (2) existing layers. Shingles shall be removed prior to installation of any unlike roofing material. If the any roofing material is deteriorated or water-soaked as to not provide an adequate base for the new material the existing roof material is required to be removed and replaced. These guidelines may not cover all re-roof permit requirements, please contact at 314-513-5033 with any questions you may have. City of Hazelwood Code Enforcement 415 Elm Grove Lane Hazelwood, Missouri 63042

City Policy and Adopted Codes requiring all Siding and Entire Roof Match 2009 International Property Maintenance (PM) and 2009 Residential Code (R) PM102.5 Workmanship. Repairs, maintenance work, alterations or installations which are caused directly or indirectly by the enforcement of this code shall be executed and installed in a workmanlike manner and installed in accordance with the manufacturer s installation instructions. R201.3 Terms defined in other codes. Where terms are not defined in this code such terms shall have meanings ascribed to them as in other code publications of the International Code Council. SECTION R104 DUTIES AND POWERS OF THE BUILDING OFFICIAL R104.1 General. The building official is hereby authorized and directed to enforce the provisions of this code. The building official shall have the authority to render interpretations of this code and to adopt policies and procedures in order to clarify the application of its provisions. Such interpretations, policies and procedures shall be in conformance with the intent and purpose of this code. Such policies and procedures shall not have the effect of waiving requirements specifically provided for in this code. R104.3 Notices and orders. The building official shall issue all necessary notices or orders to ensure compliance with this code. R104.9 Approved materials and equipment. Materials, equipment and devices approved by the building official shall be constructed and installed in accordance with such approval. City of Hazelwood Municipal Code ARTICLE IV. ARCHITECTURAL CONTROL SECTION 500.120: PURPOSES OF ARTICLE A. The general purposes of this Article are to promote and protect the public health, safety and the general welfare of the community. B. The City Council finds there is a need to exercise architectural control so as to prevent the erection or construction of inappropriate and harmful structures which have the following characteristics: 1. Floor areas less than the standards of surrounding buildings in the same residential neighborhood; 2. Stereotype exterior design with buildings in the same residential neighborhood; 3. Appears unsightly, grotesque and unsuitable, when compared with residential and other buildings erected in the same residential neighborhood, for occupancy as single-family residence purposes; 4. Impair the benefits of occupancy of existing residential property in such areas; 5. Impair the stability and value of both improved and unimproved real property in such areas; 6. Prevent the most appropriate use of such real property, and the most appropriate development of such areas; 7. Produce degeneration of residential property in such areas with attendant deterioration of conditions; and 8. Deprive the City of tax revenue which it otherwise could receive and destroys a proper balance in relationship between the taxable value of real property in such areas and the cost of the municipal services provided therefor. It is the purpose of this Article to prevent these and other harmful effects to promote and protect the health, safety, morals and general welfare of the community. (CC 1997 7.16; Ord. No. 2776-96, 7-17-96)

2009 International Residential Code Smoke Detectors R314.3.1 Alterations, repairs and additions. When alterations, repairs or additions requiring a permit occur, or when one or more sleeping rooms are added or created in existing dwellings, the individual dwelling unit shall be equipped with smoke alarms located as required for new dwellings. Exceptions: 1. Work involving the exterior surfaces of dwellings, such as the replacement of roofing or siding, or the addition or replacement of windows or doors, or the addition of a porch or deck, are exempt from the requirements of this section. 2. Installation, alteration or repairs of plumbing or mechanical systems are exempt from the requirements of this section. Location and Type of Required Smoke Detectors Interconnected Hard Wired (AC) with Battery Back-up 1. One per bedroom 2. One per level 3. One Combo Smoke/Carbon Monoxide detector in hallway 4. One within 10 feet, outside of all bedrooms doors