Human Angiotensin 2 (Ang2) ELISA

Similar documents
Mouse Peptide YY (PYY) ELISA

Human Selenoprotein P1, Plasma (SEPP1) ELISA

Mouse Gonadotropin Releasing Hormone (GnRH) ELISA

Human Myostatin, ELISA Kit (MSTN)

Mouse Coagulation Factor X (F10) ELISA

Human Collagen Type III (COL3) ELISA

Guinea pig Carboxy Terminal. Propeptide of Type 1 Procollagen. (PICP) ELISA kit

1 MICROTITER PLATE 96 wells 2 ENZYME CONJUGATE 10.0 ml 1 vial 3 STANDARD.1 0 pg/ml 1 vial 4 STANDARD pg/ml 1 vial 5 STANDARD.

Human Cardiac Troponin T (ctnt) ELISA

Rat Cardiac Troponin T (ctnt) ELISA

****** Competition ELISA Kit Instruction

Rat TAR DNA Binding Protein 43 (TDP-43) ELISA

Rat Cardiac Troponin I (ctni) ELISA

Human Glutamate Cysteine Ligase Catalytic subunit (GCLC) ELISA

Human free Fatty Acid (FFA) ELISA kit

Goat Hyaluronic Acid ELISA kit

Human Remnant lipoprotein cholesterol (RLP-C) ELISA

Human Basic Fibroblast growth factor (bfgf) ELISA

Human Procollagen Type I C-Terminal Propeptide ELISA kit

Human Collagen Type III Alpha 1 ELISA kit

MyBioSource.com. Human Total Bilirubin (TBB) Elisa kit. (Competitive ELISA)

Mouse Luteinizing Hormone (LH) ELISA

Rat Calcitonin Gene Related Peptide (CGRP) Elisa kit

Mouse anti-tnf-alpha autoantibody ELISA Kit. (TNFa-Ab) ELISA kit. 96 Tests. Catalog Number: MBS Store all reagents at 2-8 C

Human 25 Hydroxy Vitamin D3 ELISA kit

Mouse Neurofilament light polypeptide ELISA kit

Human Anti-platelet antibody ELISA kit

Monkey Peptide YY (PYY) Elisa kit

MyBioSource.com. Rat 25 Hydroxy Vitamin D3 (25-OHVD3) Elisa kit (Sandwich ELISA)

Human connective tissue growth factor (CTGF) ELISA Kit. MyBioSource.com. This package insert must be read in its entirety before using this product.

MyBioSource.com. Rat 1,25 Hydroxy Vitamin D3 (1,25OHVD3) Elisa kit(sandwich ELISA)

MyBioSource.com. Human α Melanocyte Stimulating. Hormone (αmsh) Elisa kit (Sandwich ELISA)

IL-6 Ultrasensitive ELISA

Monkey hs-tnt ELISA Kit

Guinea pig PGI2 ELISA Kit

Human LENK ELISA Kit

Rat α-melanocyte stimulating hormone (α-msh) ELISA Kit

Chicken VEGF ELISA Kit

Table of Contents 1. INTENDED USE PRINCIPLE OF THE ASSAY MATERIALS SPECIMEN COLLECTION AND STORAGE MATERIALS AND EQUIP

Deer insulin-like growth factors 1 (IGF-1) ELISA Kit. This package insert must be read in its entirety before using this product.

Rat GLO ELISA Kit. For the quantitative in vitro determination of Rat Glyoxalase concentrations in

Bovine IgG-Ab ELISA Kit

Human CTRP5 ELISA Kit

Fish Estradiol(E2) ELISA Kit

Procine CRP ELISA Kit

Canine PHA ELISA Kit

Mouse RF IgM ELISA Kit

Guinea pig TIMP-1 ELISA Kit

Human CoxV-A16 ELISA Kit

Mouse Noradrenaline (NA) ELISA Kit

Mouse Oxytocin(OT) ELISA Kit

Guinea pig Hyp ELISA Kit

Human nuclear matrix protein 22 (NMP-22) ELISA Kit. MyBioSource.com

Sheep oxytocin (OT) ELISA Kit

Guinea pig 25-OH-VD ELISA Kit

Bovine Prostaglandin E2 (PG-E2) ELISA Kit

Rat follicle-stimulating hormone (FSH) ELISA Kit

Bovine anti-mullerian hormone (AMH) ELISA Kit

Rabbit C-reactive protein(crp) ELISA Kit

Human papillomavirus type 16 (HPV16) antibody (IgM) ELISA

Bovine prolactin/luteotropic hormone (PRL/LTH) ELISA Kit

Mouse thyroxine(t4) ELISA Kit

Goat immunoglobulin G (IgG) ELISA Kit

Human ferritin(fe) ELISA Kit

Hamster follicle stimulating hormone (FSH) ELISA Kit

Human Hyperglycosylated Chorionic Gonadotropin (hcg) ELISA Kit

Human Hyperglycosylated Chorionic Gonadotropin (hcg) ELISA Kit

Human placenta lactogen (HPL) ELISA Kit

Mouse Blood Urea Nitrogen (BUN) Elisa kit

Rat Testosterone (T) ELISA Kit (OKCA00179)

Rabbit immunoglobulin M(IgM) ELISA Kit

Table of Contents 1. INTENDED USE PRINCIPLE OF THE ASSAY MATERIALS SPECIMEN COLLECTION AND STORAGE MATERIALS AND EQUIP

Human 8-Hydroxydeoxyguanosine (8-OHdG) ELISA Kit

Human Bordetella Pertussis IgG ELISA kit

Human procollagen type III (HPCⅢ) ELISA Kit

Human papillomavirus antibody (IgM) ELISA

Table of Contents 1. INTENDED USE PRINCIPLE OF THE ASSAY MATERIALS SPECIMEN COLLECTION AND STORAGE MATERIALS AND EQUIP

Mouse immunoglobulin M(IgM) ELISA Kit

Anti- Tissue Transglutaminase TTG IgG ELISA Kit

Rat thyroxine(t4) ELISA Kit

Chicken tumor necrosis factor α (TNF-α) ELISA Kit

Monkey apolipoprotein A1 (Apo-A1) ELISA Kit. For the quantitative determination of monkey apolipoprotein A1 (Apo-A1) concentrations in serum, plasma.

Rat gamma-aminobutyric acid (GABA) ELISA Kit

Human vitamin B12 (VB12) ELISA Kit

Sheep 5-hydroxytryptamine/serotonin(5HT/ST) ELISA kit

Human GTPase KRas (KRAS) ELISA Kit

Human immunoglobulin G(IgG) ELISA Kit

Cat Toxoplasma IgG ELISA Kit

Human vascular endothelial cell growth factor A (VEGF-A) ELISA Kit

Human Lipoprotein Lipase (LPL) ELISA Kit

Human Growth Differentiation Factor 11 (GDF11) Elisa kit

Pig vasoactive intestinal peptide (VIP) ELISA Kit

Bovine folic acid (FA) ELISA Kit

Rat folic acid (FA) ELISA Kit

Human Amyloid Beta Peptide 1-42 (Aβ1-42) ELISA Kit

ANCA Screen IgG ELISA Kit

Mouse high density lipoprotein (HDL) ELISA Kit

Human vitamin B12 (VB12) ELISA Kit

Human apolipoprotein C3 (apo-c3) ELISA Kit

Transcription:

Human Angiotensin 2 (Ang2) ELISA For the quantitative determination of human Ang2 in serum, plasma, cell culture fluid and other biological fluids Cat. No. KT-52748 For Research Use Only. Not for use in diagnostic procedures. Page 1 of 5 Rev. 2010-02-17

Product Information Human Angiotensin 2 (Ang2) ELISA Cat. No. KT-52748 INTENDED USE This Ang2 ELISA kit is intended for laboratory research use only and is not for use in diagnostic or therapeutic procedures. The stop solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of Ang2 in the sample, this Ang2 ELISA kit includes a set of calibrators. The calibrators are assayed at the same time as the samples and allow the operator to produce a calibration curve of optical density versus Ang2 concentration. The concentration of Ang2 in the samples is then determined by comparing the O.D. of the samples to the calibration curve. PRINCIPLE The coated well immunoenzymatic assay for the quantitative measurement of serum Ang2 utilizes a monoclonal anti-ang2 and a Ang2-HRP conjugate. The assay sample and buffer are incubated together with anti-ang2 antibody coated plate for sixty and washed. The diluted Ang2-HRP conjugate is then added to each well and incubated. After the incubation period, the wells are decanted and washed three times. The wells are then incubated with a substrate for the enzyme. The product of the enzymesubstrate reaction forms a blue colored complex. Finally, a stopping solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450 nm in a microplate reader. The intensity of the color is inversely proportional to the Ang2 concentration since Ang2 from samples and Ang2-HRP conjugate compete for the anti-ang2 antibody binding site. Since the number of sites is limited, as more sites are occupied by Ang2 from the sample, fewer sites are left to bind Ang2-HRP conjugate. Calibrators of known Ang2 concentrations are run concurrently with the samples being assayed and a calibration curve is plotted relating the intensity of the color (Optical Density) to the concentration of Ang2. The unknown Ang2 concentration in each sample is interpolated from this curve. COMPONENTS Reagents Microtiter Plate Calibrator 1 (0 pg/ml) 1 Calibrator 2 (50 pg/ml) 1 Calibrator 3 (100 pg/ml) 1 Calibrator 4 (250 pg/ml) 1 Calibrator 5 (500 pg/ml) 1 Calibrator 6 (1,000 pg/ml) 1 Enzyme Conjugate Substrate A Substrate B Stop Solution Wash Buffer (100X concentrate) Lysis Buffer Solution Quantity 96 wells 1 x 10 ml Page 2 of 5 Rev. 2010-02-17

Note: The lysis buffer solution is used only when the sample is cell culture fluid & body fluid & tissue homogenate; If the sample is serum or blood plasma, then the lysis buffer solution is a superfluous reagent. STORAGE All reagents provided are stored at 4 C. Refer to the expiration date on the label. SAMPLE COLLECTION AND STORAGE Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at approximately 1,000 x g. Remove serum and assay immediately or aliquot and store samples at -20 C or -80 C. Plasma Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1,000 x g at 4 C within 30 minutes of collection. Store samples at -20 C or -80 C. Avoid repeated freeze-thaw cycles. Cell culture fluid and other biological fluids Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20 C or -80 C. Avoid repeated freeze-thaw cycles. NOTE: Serum, plasma and cell culture fluid samples to be used within 7 days may be stored at 4 C, otherwise samples must be stored at -20 C ( 2 months) or -80 C ( 6 months) to avoid loss of bioactivity and contamination. Avoid freeze-thaw cycles. When performing the assay slowly bring samples to room temperature. DO NOT USE HEAT-TREATED SPECIMENS. MATERIALS REQUIRED BUT NOT SUPPLIED 1. Microplate reader capable of measuring absorbance at 450 nm. 2. Precision pipettes to deliver 2 ml to 1 ml volumes. 3. Adjustable 10-100 ml pipettes for reagent preparation. 4. 100 ml and 1 liter graduated cylinders. 5. Calibrated adjustable precision pipettes, preferably with disposable plastic tips. (A manifold multichannel pipette is desirable for large assays.) 6. 37 C incubator. 7. Absorbent paper. 8. Distilled or de-ionized water 9. Data analysis and graphing software. Graph paper: linear (Cartesian), log-log or semi-log, or log-logit as desired. 10. Tubes to prepare calibrator or sample dilutions. Precautions 1. Kamiya Biomedical Company is only responsible for the kit itself, but not for the samples consumed during the assay. The user should calculate the possible amount of the samples used in the whole test. Please reserve sufficient samples in advance. 2. Please predict the concentration before assaying. If values for these samples are not within the range of the calibration curve, users must determine the optimal sample dilutions for their particular experiments. 3. If the samples are not indicated in the manual, a preliminary experiment to determine the validity of the kit is necessary. 4. Owing to the possibility of mismatching between antigen from other resource and antibody used in our kits (e.g. antibody targets conformational isotope rather than linear isotope), some native or recombinant proteins from other manufacturers may not be recognized by our products. Page 3 of 5 Rev. 2010-02-17

5. Influenced by the factors including cell viability, cell number and also sampling time, samples from cell culture supernatant may not be detected by the kit. 6. Fresh samples without long term storage is recommended for the test. Otherwise, protein degradation and denaturalization may occur in those samples and finally lead to wrong results. REAGENT PREPARATION Bring all kit components and samples to room temperature (18-25 C) before use. Dispense 5 µl of lysis buffer solution into 50 µl specimens, mix and stand for one hour (The proportion of lysis buffer and specimens shall be no less than 1:10). (NOTE: This step is required when the sample is cell culture fluid & body fluid & tissue homogenate; If the sample is serum or blood plasma, then this step should be skipped.) Wash Solution Dilute 10 ml of Wash Solution concentrate (10X) with 990 ml of de-ionized or distilled water to prepare 1,000 ml of Wash Solution (1X). ASSAY PROCEDURE It is recommended that all Calibrators and Samples be added in duplicate to the Microtiter Plate. 1. Secure the desired number of coated wells in the holder, then add 100 µl of Calibrators or Samples to the appropriate well of the antibody pre-coated Microtiter Plate. 2. Add 50 µl of Conjugate to each well. Mix well. Complete mixing in this step is important. Cover and incubate for 1 hour at 37 C. 3. Wash the microtiter plate using one of the specified methods indicated below: 4. Manual Washing: Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well completely with wash solution, then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure four more times for a total of five washes. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame. 5. Automated Washing: Aspirate all wells, then wash plate five times using wash solution. Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350 µl/well/wash (range: 350-400 µl). After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. It is recommended that the washer be set for a soaking time of 10 seconds or shaking time of 5 seconds between washes. 6. Add 50 µl substrate A and 50 µl substrate B to each well. Cover and incubate for 10 minutes at 20-25 C. (Avoid exposure to light.) 7. Add 50 µl stop solution to each well. Mix well. 8. Read the optical density (OD) at 450 nm using a microtiter plate reader immediately. CALCULATION OF RESULTS 1. This calibration curve is used to determine the amount in an unknown sample. The calibration curve is generated by plotting the average OD (450 nm) obtained for each of the six calibrator concentrations on the vertical (Y) axis versus the corresponding concentration on the horizontal (X) axis. 2. First, calculate the mean OD value for each calibrator and sample. All OD values are subtracted by the mean value of the zero calibrator before result interpretation. Construct the calibration curve using graph paper or statistical software. 3. To determine the amount in each sample, first locate the OD value on the Y-axis and extend a horizontal line to the calibration curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration. 4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in the result. Each user should obtain their own calibration curve. 5. The sensitivity by this assay is 1.0 pg/ml. Disposal Note Safety 1. This kit contains materials with small quantities of sodium azide. Sodium azide reacts with lead and copper plumbing to form explosive metal azides. Upon disposal, flush drains with a large volume of Page 4 of 5 Rev. 2010-02-17

water to prevent azide accumulation. Avoid ingestion and contact with eyes, skin, and mucous membranes. In case of contact, rinse affected area with plenty of water. Observe all federal, state, and local regulations for disposal. 2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents. IMPORTANT NOTES 1. When not in use, kit components should be refrigerated. All reagents should be warmed to room temperature before use. 2. Microtiter plates should be allowed to come to room temperature before opening the foil bags. Once the desired number of strips has been removed, immediately reseal the bag and store at 4 C to maintain plate integrity. 3. Samples should be collected in pyrogen/endotoxin-free tubes. 4. Samples should be frozen if not analyzed shortly after collection. Avoid multiple freeze-thaw cycles of frozen samples. Thaw completely and mix well prior to analysis. 5. When possible, avoid use of badly hemolyzed or lipemic sera. If large amounts of particulate matter are present, centrifuge or filter prior to analysis. 6. It is recommended that all calibrators, controls, and samples be run in duplicate. 7. When pipetting reagents, maintain a consistent order of addition from well-to-well. This ensures equal incubation time for all wells. 8. Cover or cap all reagents when not in use. 9. Do not mix or interchange different reagent lots from various kit lots. 10. Do not use reagents after the kit expiration date. 11. Read absorbances within 2 hours of assay completion. 12. All residual wash liquid must be drained from the wells by efficient aspiration or by decantation followed by tapping the plate forcefully on absorbent paper. Never insert absorbent paper directly into wells. 13. Because stabilized Chromogen is light sensitive, avoid prolonged exposure to light. Also avoid contact between stabilized Chromogen and metal, or color may develop. 14. Incomplete washing will adversely affect the test outcome. All washing must be performed with wash buffer provided. 15. Washing can be performed manually as follows: completely aspirate the liquid from all wells by gently lowering an aspiration tip (aspiration device) into the bottom of each well. Take care not to scratch the inside of the well. 16. After aspiration, fill the wells with at least 0.35 ml of diluted wash solution. Let soak for 10-15 seconds, then aspirate the liquid. Repeat as directed under Assay Procedure. After the washing procedure, the plate is inverted and tapped dry on absorbent tissue. 17. Alternatively, the wash solution may be put into a squirt bottle. If a squirt bottle is used, flood the plate with wash buffer, completely filling all wells. After the washing procedure, the plate is inverted and tapped dry on absorbent tissue. 18. If using an automated washer, the operating instructions for washing equipment should be carefully followed. 19. Assay Procedure Preliminary notes: Do not mix reagents from different lots. It is recommended that assays be performed in duplicate. Calibrators and samples must be assayed at the same time. Avoid exposing the substrate to direct sunlight. FOR RESEARCH USE ONLY. Not for use in diagnostic procedures. 12779 Gateway Drive, Seattle, WA 98168 Tel: (206) 575-8068 Fax: (206) 575-8094 Email: LifeScience@k-assay.com www.k-assay.com Page 5 of 5 Rev. 2010-02-17