An effective platform for purification of IgM monoclonal antibodies using Hydroxyapatite

Similar documents
The practical task of monoclonal IgG purification with CHT TM ceramic hydroxyapatite

Nonionic Polymer Enhancement of Aggregate Removal in Ion Exchange

Recent improvements in the use of CHT TM ceramic hydroxyapatite for removal of aggregates from monoclonal Antibodies

Phosphate-Free Buffer Systems A New Frontier for Apatite Chromatography

A Case Study of Early Phase Purification Process Development for an Anti-Cancer Minibody

Practical Issues in the Industrial use of Hydroxyapatite for Purification of Monoclonal Antibodies

IgM Purification! (the fine print)!

The Promise of Monolith-based Industrial Purification of Biomolecules

Simultaneous removal of aggregates, leached protein A, endotoxin, and DNA from protein A purified IgG with CHT TM ceramic hydroxyapatite and CFT TM

Dissociation of Naturally Occurring Antibody-Contaminant Complexes with Hydroxyapatite!

Application Note. Rapid optimisation and development of an automated two-step purification procedure for monoclonal IgG antibodies.

3. Close the bottom end of the column and apply the packing device on top. Pump water through the upper adaptor to remove air.

Capture of mouse monoclonal antibodies

1. Bloomsbury BBSRC Centre for Structural Biology, Birkbeck College and University College London.

AFFINITY HIS-TAG PURIFICATION

GORE. Protein Capture Devices. Operating Instructions Contents. Product Description Device Characteristics... 2 General Handling...

BACTERIAL PRODUCTION EXPRESSION METHOD OVERVIEW: PEF # GENE NAME EXPRESSION VECTOR MOLECULAR WEIGHT kda (full-length) 34.

Phenyl Membrane Adsorber for Bioprocessing

PROCEDURE FOR USE NICKEL NTA Magnetic Agarose Beads (5%)

WorkBeads Protein A INSTRUCTIONS IN

TECHNICAL BULLETIN. HIS-Select HF Nickel Affinity Gel. Catalog Number H0537 Storage Temperature 2 8 C

Separation of Monoclonal Antibodies Using TSKgel HPLC Columns

Q and S HyperCel Sorbents

ProteIndex Chemical-Tolerant Ni-Penta Agarose. Prepacked Cartridge. 6 FF Prepacked Cartridge, 5 x 1 ml settled resin

AFFINITY HIS-TAG PURIFICATION

Nuvia S and Q High-Capacity Ion Exchange Media Instruction Manual

Purification of oligonucleotides by anion exchange chromatography

AFFINITY HIS-TAG PURIFICATION

Phenyl Membrane Adsorber for Bioprocessing

SERVA Ni-NTA Magnetic Beads

Affi-Gel Protein A MAPS II Kit Instruction Manual

AFFINITY HIS-TAG PURIFICATION

Tools and solutions for separation of charged mab variants

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

Purification Polishing of His-tagged proteins

Nuvia HR-S Strong Cation Exchange Media Instruction Manual

INSECT CELL/BACULOVIRUS PRODUCTION

Nickel Chelating Resin Spin Columns

Capacity and performance of MabSelect PrismA protein A chromatography resin

TOYOPEARL GigaCap Series

Column for High Performance,High-Binding Capacity Ion Exchange Chromatography:TSKgel SuperQ-5PW and Its Applications

Cobalt Chelating Resin

Polishing of monoclonal antibodies using Capto S ImpAct

Chromatography column for therapeutic protein analysis

Productivity improvements in the capture and initial purification of monoclonal antibodies

1. Connect the column to the chromatography system, syringe or pump.

Nickel-NTA Agarose Suspension

His Mag Sepharose excel

TECHNICAL BULLETIN. Ni-CAM HC Resin High Capacity Nickel Chelate Affinity Matrix. Product No. N 3158 Storage Temperature 2 8 C

Ni-NTA Agarose. User Manual. 320 Harbor Way South San Francisco, CA Phone: 1 (888) MCLAB-88 Fax: 1 (650)

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Econo-Pac Serum IgG Purification Kit and Econo-Pac Serum IgG Purification Columns Instruction Manual Catalog Numbers and

INSTRUCTIONS The resins are adapted to work mainly in native conditions like denaturing.

... Macro-Prep 25 Ion Exchange Supports. Instruction Manual

Introduction to Protein Purification

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , ,

MBP Excellose handbook - Purification of MBP fusion proteins -

Adsorptive and Mechanical Mechanisms of Fluid Purification Using Charge Modified Depth Filtration Media. Dr. Robert Conway, Ph.D.

Dynamic High Capacity Mustang Q Membrane Units for Scaleable Anion Exchange Chromatography Purification of Adenoviral Vectors

Table 1, Performance characteristics of Cellufine SPA-HC

Case Studies of POROS Chromatography for Use in Vaccine and Large Biomolecule Purification

(Refer Slide Time: 00:16)

Next Generation Zirconia-Based Antibody Purification Media

Retention behavior of endotoxin, DNA, and protein A on CHT TM ceramic hydroxyapatite and CFT TM ceramic fluorapatite

HyperCel STAR AX Ion Exchange Sorbent

Purification of (recombinant) proteins. Pekka Lappalainen, Institute of Biotechnology, University of Helsinki

UNOsphere Q & S Ion Exchange Media. Instruction Manual ...

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

Convenient Purification of Monoclonal Antibodies using HiTrap rprotein A FF

SERVA IMAC Ni-IDA Test Kit Agarose for Affinity Purification of His-Tag Fusion Proteins

Operating Instructions Heparin Mimetic Affinity

Analysis of biomolecules by SEC and Ion-Exchange UPLC

AminTRAP HIS Prepacked Column

Capture of human single-chain Fv (scfv) fusion protein on Capto L affinity medium

Ab SpinTrap Ab Buffer Kit

Mimetic Blue Affinity Adsorbents Mimetic Blue 1 P6XL, Mimetic Blue SA P6XL Mimetic Blue SA HL P6XL, Mimetic Blue ELISA Kit

Adsorptive Chromatography: the Influence of Stationary Phase Architecture!

Application Note USD Purification of Mouse IgM from Cell Culture Supernatant by Cation Exchange Chromatography on CM Ceramic HyperD F Sorbent

The use of Chromatography Membranes for the development and production of biopharmaceuticals.

HyperCel STAR AX Ion Exchange Sorbent

Sartobind TM Membrane Adsorbers Discs and Cassettes

AFFINITY HIS-TAG PURIFICATION

The above media is designed to purify antibodies from aggregates and other impurities.

Automating mab Purification Workflows: Combining Tandem and Multidimensional (Multi-D) Purification Using the NGC Chromatography System

ProteIndex TM Co-NTA Agarose 6 Fast Flow

Capto Blue and Capto Blue (high sub)

BioPro SmartSep. Benefits of using BioPro SmartSep. Product information

BabyBio S BabyBio Q BabyBio DEAE

Jan 25, 05 His Bind Kit (Novagen)

His-Spin Protein Miniprep

Size Exclusion BioHPLC columns Ion Exchange BioHPLC columns

MagExtactor -His-tag-

Introduction to Affinity Chromatography (AC) By: Sunsanee Yoojun Bang Trading 1992 Co., Ltd.

Ion Exchange Chromatography. Teaching Kit Manual. GeNei TM. Cat No. New Cat No. KT Revision No.:

Strep-Tactin XT Spin Column

CX-1 ph Gradient Buffer

DexS-HbP. Technical Note Heparin Mimetic Affinity. Model Protein adsorption to Cellufine MAX DexS-HbP resin

YMC-BioPro NEW. porous and nonporous IEX columns. For the analysis and separation of peptides, proteins and biomolecules

Fast protein separations with ion exchange columns

DEAE Affi-Gel Blue Gel Instruction Manual

Transcription:

An effective platform for purification of IgM monoclonal antibodies using Hydroxyapatite Frank Hensel, Patrys, GmbH Pete Gagnon, Validated Biosystems 5th International Conference on Hydroxyapatite and Related Products Rottach-Egern, Germany, October 11-14, 2009

Why work with IgMs? Natural immunity of humans against cancer cells consists almost exclusively of IgM. These antibodies can be isolated from healthy people and cancer patients by fusion technology. Natural IgMs are highly tumor-specific. Patrys Ltd. has a broad pipeline of tumor-specific and cytotoxic IgMs. Lead candidate to be scheduled to enter clinical trials by Q4, 2009. 2

Structure and properties of IgM Pentameric, 0.96 MDa Hexameric, 1.15 MDa 7.5-12 % carbohydrate, extinction coefficient 1.18 Randall et al, 1990, The biological effects of IgM hexamer formation, Eur. J. Immunol., 20 1971-1979 Johnstone and Thorpe, 1987, Immunochemistry in Practice, 2nd Ed., Blackwell Scientific Publishers, Oxford

Are IgMs really difficult to purify? IgMs have some characteristics that can limit the application of standard purification tools. They are susceptible to denaturation at extremes of ph. This can limit application of affinity chromatography. They are poorly soluble at low conductivity. This can limit application of ion exchange chromatography. They are susceptible to denaturation from exposure to strongly hydrophobic surfaces. This can limit application of hydrophobic interaction chromatography. Size exclusion chromatography is mild and effective but productivity is prohibitively low.

Are IgMs really difficult to purify? The size of IgMs is also a challenge. Large size corresponds with slow diffusion constants. Porous particle based chromatography media depend on diffusion for mass transport. Slow diffusion constants translate into lower capacity and lower resolution, and/or lower flow rates on porous particle based chromatography media. Monolithic ion exchangers can overcome the mass transport limitations of diffusion, but solubility issues remain.

Are IgMs really difficult to purify? On the positive side, IgMs are typically more charged than IgGs. They bind much more strongly than IgG to anion exchangers, or cation exchangers, or both. They also bind more strongly than IgG to hydroxyapatite, and much more strongly than most contaminants. These characteristics allow hydroxyapatite and ion exchangers to purify most IgMs without exposing them to extreme conditions.

Method scouting Initial screening, hydroxyapatite Media: 1 ml CHT type II 40 µm Column: MediaScout 5 x 50 mm Flow rate: 0.67 ml/min Buffer A: 10 mm NaPO4, ph 7.0 Buffer B: 500 mm NaPO4, ph 7.0 Equilibrate: buffer A Sample: IgM CCS Load: 2 ml Wash: 5 CV buffer A Elute: 20 CV LG to buffer B Highlighted peak is IgM. This profile is typical of IgMs, most of which elute from hydroxyapatite in a well defined peak between 200 and 300 mm phosphate. The green trace illustrates the same profile at lower sensitivity.

Method scouting Gradient optimization, hydroxyapatite Media: 1 ml CHT type II 40 µm Column: MediaScout 5 x 50 mm Flow rate: 0.67 ml/min Buffer A: 10 mm NaPO4, ph 7.0 Buffer B: 500 mm NaPO4, ph 7.0 Equilibrate: buffer A Sample: IgM CCS Load: 2 ml Wash: 5 CV buffer A Elution gradients indicated in red Highlighted peak is IgM. Blue trace reproduces screening results from previous slide. Lower trace illustrates improved purity from optimized gradient set points.

Method scouting Initial screening, cation exchange, ph 7.0 Media: CIM SO3, 0.34 ml Flow rate: 4 ml/min Buffer A: 10 mm NaPO4, ph 7.0 Buffer B: 500 mm NaPO4, ph 7.0 Equilibrate: buffer A Load: 100 µl IgM CCS Wash: buffer A Elute: 34 CV LG to 50% buffer B Clean with 100% buffer B

Method scouting Initial screening, cation exchange, ph 6.0, 7.0, 8.0 Media: CIM SO3, 0.34 ml Flow rate: 4 ml/min Buffer system A: ph 6.0 Buffer system B: ph 7.0 Buffer system C: ph 8.0 Same sample and run configuration as previous slide Highlighted peak is IgM. Uppermost trace shows results at ph 6.0. Center trace, ph 7.0. Lowermost trace, ph 8. Note stronger binding at ph 6, better purification at 8.0. Further improvement is achievable with gradient optimization.

Method scouting Initial screening, anion exchange, ph 7.0 Media: CIM QA, 0.34 ml Flow rate: 4 ml/min Buffer A: 10 mm NaPO4, ph 7.0 Buffer B: 500 mm NaPO4, ph 7.0 Equilibrate: buffer A Load: 100 µl Wash: buffer A Elute: 34 CV LG to 50% buffer B Clean with 100% buffer B Highlighted peak is IgM. Blue trace, IgM CCS. Green trace, CHT-purified IgM. Strong anion exchange retention is typical of IgMs.

Sample loading and capacity Hydroxyapatite - Directly compatible with cell culture supernatant - Filter to 0.2 µm - Titrate ph to 7.0 - Add phosphate to 5 mm - Capacity up to 25 mg/ml

Sample loading and capacity Ion exchange - In order to avoid product precipitation at low conductivity, load sample by in-line dilution. Titrate sample ph to target, load through inlet A Dilute with buffer, through inlet B Dilution factor depends on the charge characteristics of the antibody, the starting conductivity, and the desired capacity. Typical dilution factors range from 1:2 to 1:9 Capacity: 20-40 mg/ml at 12 CV/min on monoliths, depending on sample conductivity.

Sample loading and capacity Lower in-line dilution factors reduce sample loading time. Higher in-line dilution factors increase capacity, which reduces column size and buffer volumes. This also increases eluted product concentration, which reduces sample volume going into the next step. In-line dilution suspends the need to employ diafiltration for intermediate sample preparation. This eliminates costly equipment, materials, preparation/operating/maintenance time, validation, and the inevitable losses that occur at each processing step.

Process sequencing Hydroxyapatite is generally well suited for IgM capture. Mild operating conditions. Minimal sample conditioning (no significant dilution). Most contaminants flow through, leaving capacity available for product. Most IgMs elute at 200-300 mm phosphate HA may discolor from iron in CCS. Chelating agents may reduce column life.

Process sequencing Substantial dilution will probably be required for capture on ion exchangers. This is undesirable, especially at the first step, where product concentration will be the lowest of the entire process. In this case, the IgM bound to the anion exchanger at higher conductivity than to the cation exchanger. Since the HA eluate had the highest conductivity in the process, it was followed with anion exchange. Cation exchange was positioned as a final polishing step.

Process modeling After establishing a preliminary process order, loading conditions, capacity, and separation conditions, it is useful to run the integrated process to provide a benchmark of overall process performance and economics. A good working process model highlights its own deficiencies, provides an order of priority for addressing them, and allows each one to be evaluated in a meaningful context. Defer optimization of individual steps until after the benchmark has been run.

Process modeling Our modeling run revealed that DNA co-eluted with the IgM. This was a serious concern because DNA and IgM form charge complexes that can be fully dissociated only at high salt concentrations* usually higher salt concentrations than are employed to elute IgM from ion exchangers. If no steps are taken to control this phenomenon, DNA tends to be transported through the entire process, and fails to be reduced to adequate levels in the final product. * IgM purification on immobilized DNA: M. Abdullah et al, 1985, J. Chromatogr., 347 129-136

Process modeling The point of highest conductivity in the process was the elution step from CHT. We evaluated insertion of a membrane anion exchanger at this point to reduce DNA levels going into the remainder of the process. DNA binds anion exchangers at NaCl concentrations up to 0.6 M, so no sample dilution was required. The IgM was not retained under these conditions. We were able to plumb the membrane in tandem with the CHT column but ultimately chose to run it as a separate unit operation to simplify validation and documentation.

Process modeling Capture on hydroxyapatite Load: 4.65 L of clarified harvest Column: 3.2 cm x 15 cm (120.6 ml) CHT Type II, 40 micron Run velocity: 150 cm/hr Load adjusted to 1% (v/v) 0.5 M sodium phosphate, ph 7.0 to achieve a final [phosphate] of 5 mm. Buffer A: 10 mm sodium phosphate, 10% PEG-600, ph 7.0 Buffer B: 500 mm sodium phosphate, 10% PEG-600, ph 7.0 Buffer C: 1% Triton-X 100, in 10 mm sodium phosphate, ph 7.0 Buffer D: 1 N NaOH Buffer E: 0.1 N NaOH --------- See Gagnon, 2009, J. Immunol. Met., 336 222-228 for explanation of aggregate removal in the presence of PEG. 20

Process modeling DNA removal by membrane anion exchange DNA elution Load: 210 ml pooled CHT eluate Membrane: Sartobind Q Mini Membrane Area: 0.025 m 2 Equilibrate filter with 10 mm sodium phosphate, 10% PEG-600, ph 7.0 Collect flow-through Strip filter with 2 M NaCl Note the difference in UV absorbance at 254 nm (red) and 280 nm (blue). IgM flow-through 21

Process modeling Intermediate purification by anion exchange chromatography Load: 53 ml Sartobind Q filtrate diluted 5X with Buffer A Column: 8 ml QA Monolith Flow rate: 30 ml/min; 3.75 CV/min Buffer A: 50 mm Tris, 2 M Urea, 2 mm EDTA, ph 8.0 Buffer B: 10 mm sodium phosphate, 2 M Urea, ph 7.0 Buffer C: 500 mm sodium phosphate, ph 7.0 Buffer D: 1 N NaOH Buffer E: 0.1 N NaOH 22

Process modeling Final purification by cation exchange chromatography Load: 43 ml QA eluate pool Column: 8 ml SO 3 monolith Flow rate: 30 ml/min; 3.75CV/min Buffer A: 10 mm sodium phosphate, 2 M Urea, ph 7.0 Buffer B: 500 mm sodium phosphate, ph 7.0 Buffer C: 1 N NaOH Buffer D: 0.1 N NaOH 23

Process modeling Reduced SDS-PAGE IgM Standard CHT Eluate Sartobind Q Filtrate 5X Diluted QA Load QA Eluate SO3 Eluate Final product Heavy chain Light chain 24

Process modeling Analytical SEC 99.35% non-aggregated IgM 0.65% aggregate 25

Conclusions IgM purification is different than IgG purification, but not inherently more difficult. Clinical grade material can be purified with non-affinity methods, with step recoveries comparable to those achieved with IgG. Patrys successfully transferred the present process to a CMO for production of antibody for clinical evaluation. This platform has also been applied successfully to other IgM monoclonal antibodies.

Conclusions Lower solubility and higher sensitivity to denaturation must be accommodated. Binding capacities are generally lower than for IgG but still support economical fractionation. Lack of an affinity step makes a positive contribution to process economy. Lack of intermediate diafiltration steps, made possible by loading ion exchangers by in-line dilution, also contributes to process economy.

Acknowledgements Thanks to the Process Applications group at Bio-Rad for performing early characterization of IgM behavior on hydroxyapatite.