ANSALDO ENERGIA STEAM TURBINE OPERATION IN FLEXIBLE COMBINED CYCLE. Authors:

Similar documents
Operational flexibility enhancements of combined cycle power plants

Application of Advanced Process Control systems in Enel Thermal Generation (Eleonora Porro, Giorgio Mazzola, Giordano Proietti Marini)

Steam Turbines. A Finmeccanica Company

Design and Operation of Large Fossil-Fueled Steam Turbines in Cyclic Duty

NUCLEAR TRAINING CENTRE COURSE 134 FOR ONTARIO HYDRO USE ONLY

Improving Flexibility of the Combined Cycle Power Plant Hamm Uentrop to Cover the Operational Profiles of the Future

2014 GCC Conference - Orlando, FL Sept. 30 Oct. 2, Simulation of a Combined Cycle using Dynsim. Eric Liese Office of Research and Development

Abstract. Operational Aspects of Cycling. Introduction

STARTUP TIME REDUCTION FOR COMBINED CYCLE POWER PLANTS

Flexible Operation. Integrating thermal power with Renewable Energy & Challenges. Y M Babu Technical Services, Noida

DYNAMIC MODELING OF THE ISAB ENERGY IGCC COMPLEX

Low Emission Water/Steam Cycle A Contribution to Environment and Economics. Peter Mürau Dr. Michael Schöttler Siemens Power Generation, (PG) Germany

Indo-German Energy Forum: Flexibility Case Study at Dadri and Simhadri An overview. Dr. Claudia Weise, December 1, 2017, Delhi

STEAG Energy Services Approach to Higher Flexibilization Tools and Results

Trends on Coal Fired Power Plants in Europe. Dr. Thomas Eck, 30 November 2018, New Delhi

Full electrical LNG-plant: Highest availability and energy efficiency trough overall system design

Heat Recovery Steam Generators for Flexibility

Combined Cycle Power

Economic Evaluation of Plant Upgrades Using Plant Optimization Software

REVIEW OF HRSG CAPABILITIES FOR FLEXIBLE OPERATION

NTPC O&M Conference Performance and Optimization of Water Utilisation Increase of Existing Power Plants. Speaker Name; Tufani Ram 13-14/02/2013

TECHNICAL PUBLICATION

Combined Cycle Power Plants. Combined Cycle Power Plant Overview (Single- and Multi-Shaft) Training Module. ALSTOM (Switzerland) Ltd )*+,

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017

GAS-FIRED COMBINED-CYCLE POWER PLANTS HOW DO THEY WORK? A company of

Flexible steam turbine solutions for combined heat and power in combined cycle power plants

Adding operational flexibility to a coal fired plant Integration of renewable Power in the Grid Path ahead, IPS 2017, New Delhi Dr.

Experiences with Direct Steam Generation at the Kanchanaburi Solar Thermal Power Plant

Development of Hot Standby Mode for flexible Steam Turbine Operation

Savings effected in cost of generation through control of

Steam Turbine Start-up Optimization Tool based on ABAQUS and Python Scripting

Updated Operating Parameter Definitions

Fuel Savings for Gas Power Plants. Using Digital Efficiency and Flexibility Optimization

PRODUCT DESCRIPTION PARAMETERS

MARAMA Webinar August 7, Angelos Kokkinos Chief Technology Officer Babcock Power, Inc.

From base to cycling operation - innovative concepts for thermal power plants

Mid-Load Operation of Large Coal-Fired Power Plants

Dynamic Modeling of a Combined-Cycle Plant

VFDs driving the boiler feed water pump of #11-13 Combined Cycled Generation Unit in Yangpu Thermal Power Plant by Bin Li

Pre-owned 240 MW Combined Cycle Gas Turbine Power Plant

AP1000 European 15. Accident Analysis Design Control Document

DESIGN AND ANALYSIS OF HIGH-PRESSURE CASING OF A STEAM TURBINE

12th International Conference on Fluidized Bed Technology

Unit No.4-1 Higashi Niigata Thermal Power Station Operating Status O C Class Gas Turbine Operation -

Simulation of the dynamic behaviour of steam turbines with Modelica

rd and 4 th stages, see Fig. 2). If unchecked, fouling steam turbine steam rate and requires a maximum can cost over /day.

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

Low Emissions gas turbine solutions

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

Consequences of the German Energy Transition on the operation regime and the availability of coal fired power plants

THERMAL POWER PLANT SIMULATOR TPP 200 LABORATORY EXERCISE TUTORIAL N4: INTRODUCTION TO THE HEAT PRODUCTION SYSTEM

NOx CONTROL FOR IGCC FACILITIES STEAM vs. NITROGEN

Course 0101 Combined Cycle Power Plant Fundamentals

POWER-GEN MIDDLE EAST DOHA, QATAR FEBRUARY 4th -6th 2013

VVER-440/213 - The reactor core

Guidance page for practical work 15: modeling of the secondary circuit of a PWR

Due Diligence: Efficiency Increase in Existing Power Stations - a Practice Report-

Potential of Process Integration in four Industrial Companies in Germany

m or printed in its publications. Discussion is printed only if the paper is published

Utilization of THERMOPTIM Optimization Method

COMPUTER SKILLS : Windows, MS Office, Internet : EMPAC (Enterprise Maintenance Planning and Control) System

Design and Construction of Molten Salt Parabolic Trough HPS Project in Évora, Portugal

Flexibility of the conventional Power Plants as necessary response to the electricity market conditions

Increased efficiency and flexibility in coal-fired power plants International O&M Conference NTPC siemens.com/steamturbines

Modelling of Combined Cycle Powerplants with EBSILON Professional. Dr. Hans-Peter Wolf AGH Letniej Szkoły Energetyki 2018

Flexibilisation Issues of Thermal Stations. Anjan Kumar Sinha NTPC Ltd

Hitachi H-25 & H-80 Gas Turbine. Bucharest, Apr.23, 2013

The H-25/H-15 Gas Turbine A Product of Hitachi Quality

6.1 Introduction. Control 6-1

Improving energy efficiency in an ammonia plant

Flexibility of coal and gas fired power plants Paris, Advanced Power Plant Flexibility Campaign Dr. Andreas Feldmüller

View from the Penthouse

DANIELI S GREEN STEEL VISION: FIRST STEP TOWARDS ZERO ENERGY FTP AT ABS STEELMAKING PLANT (ITALY)*

Study on Valve Management of DEH for Steam Turbine *

Innovative Boiler Design to Reduce Capitel Cost and Construction Time

District Heatingwithor. C For Additional And Cleaner POWER. ISCC and Solar Boost. Conference Paper CONFERENCE PAPER

3 Steps to Better Steam Temperature Control Proven Strategies to Minimize Thermal Stress and Tube Leaks

MEC-MOS-E-2004 Gas Turbine Maintenance Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

Fatigue Monitoring for Demonstrating

Recent Technologies for Steam Turbines

Power plant Asset. Thermal power Hydro power Geothermal power. QuestIntegrity.com CHALLENGE CONVENTION

Borregaard Case Study. Sarpsborg I & II

Predictive Intelligence Optimizing Performance & Reliability. Neeraj Agarwal Manish Khetrapal

OPTIMAX Advanced Control and Optimization of Power Plants

9HA.01 SETS EFFICIENCY WORLD RECORD

Solar Process Cold & Solar Driven Cold Rooms. Results from the SOLERA EU project Current Activities in the AgroKühl project

Design Considerations for Advanced Combined Cycle Plant Using Fast Start Drum Type HRSGs

5. Steam Turbine Performance

Fuji Electric s Medium-capacity Steam Turbines FET Series

New Requirements for Steam Turbines due to Renewable Energy Innovative Concepts for Thermal Power Plants

Piotr Lampart. New IMP PAN research - renewable energy technologies

CHAPTER 2 STUDY OF 210 MW BOILER SYSTEM 2.1 DESCRIPTION OF 210 MW BOILER

The H-25/H-15 Gas Turbine A Product of Hitachi Quality

A RATIONAL APPROACH TO EVALUATE A STEAM TURBINE ROTOR GRABBING AND LOCKING EVENT

SPPA-P3000 Process Optimization Solution Compendium. Instrumentation & Controls

Recent Rehabilitation Technology for Aging Thermal Power Generation Equipment

SMR/1848-T21b. Course on Natural Circulation Phenomena and Modelling in Water-Cooled Nuclear Reactors June 2007

Drives in Power Generation

DESIGN AND THERMAL ANALYSIS OF HIGH PRESSURE CASING OF A STEAM TURBINE

Kawasaki Gas Turbines-Americas Gas Turbines Power Generation Technology & Applications

Transcription:

ANSALDO ENERGIA STEAM TURBINE OPERATION IN FLEXIBLE COMBINED CYCLE Authors: Carlo Bima Sandro Zanier (Ansaldo Energia) (Ansaldo Energia) 1

INDEX SCENARIO PLANT FLEXIBILITY FLEXIBLE STEAM TURBINE MECHANICAL FEATURES FLEXIBLE STEAM TURBINE FUNCTIONAL FEATURES CONCLUSION 2

SCENARIO The liberalization of the energy market in the EU has led to local energy exchange market, where power production and consumption quantities are exchanged following the energy demand in a competitive environment, bringing to a floating production demand as a consequence. Combined cycle power plants have to be modified to take into account the up-to-date requests of the power market tending to: FLEXIBILITY 3

SCENARIO MARKET FLEXIBILITY REQUIREMENTS Base load operation with high efficiency and low environmental emissions (NO x, CO) Partial load operation with high efficiency and low environmental emissions (NO x, CO) Primary and secondary grid frequency control (istantaneous load step) Two shift operation 4

FLEXIBILITY FLEXIBILITY means: Plant load profile in cycling mode (Daily/Weekly Plant Start up / Shut down) Repeatable start-up Reduced start-up times Typical start-up distribution: 245/year daily start up (hot conditions) 45/year weekly start up (warm conditions) 10/year cold start up 4 full load trips 5

volume [MW] SCENARIO energy demand provision (May 2009, 15th) data from RWE Transportnetz Strom GmbH 25000 20000 15000 10000 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 hours Germany: RWE GmbH Italy: Terna S.p.A. Spain:Red Eléctrica de Espana France: RTE 6

INDEX SCENARIO PLANT FLEXIBILITY FLEXIBLE STEAM TURBINE MECHANICAL FEATURES FLEXIBLE STEAM TURBINE FUNCTIONAL FEATURES CONCLUSION 7

PLANT FLEXIBILITY There are two possible combined cycle plant operating modes: 1) two shift operation : where the plant is at full load, or partial load depending on the market requests, during the daytime and shutdowns every night and weekend. 2) minimum load operation : where the plant runs during the weekdays and shutdowns only during weekend. 8

PLANT FLEXIBILITY Two shift operation mode is the best solution because the fuel consumption costs overlook the power production gains because of the low power price per MWh in the night period In the two shift operation the only negative net is in the start-up and shut-down intervals Two shift operation mode involves: a major plant main components life consumption, as they suffer higher thermal stresses for the frequent starts; cycling capability, reduced start-up times, reliable and iterative start-up/shut-down procedures. 9

PLANT FLEXIBILITY Cycling mode operation The main items to be considered are: GT and ST improvements Thermal cycle components / systems requirements Start up and shutdown optimized procedures Evaluation of the main components life and subsequent measures to be taken to fulfill the plant expected life and the cycling operation Components / Systems requirements The main results and evaluations of Ansaldo Energia studies are: Need to maintain condenser vacuum Need to maintain HRSG drum pressure as high as possible HRSG admissible HP drum temperature gradient optimisation Attemperators at SH and HRH outlet to control Steam temperature gradients 10

PLANT FLEXIBILITY 11

INDEX SCENARIO PLANT FLEXIBILITY FLEXIBLE STEAM TURBINE MECHANICAL FEATURES FLEXIBLE STEAM TURBINE FUNCTIONAL FEATURES CONCLUSION 12

FLEXIBLE STEAM TURBINE MECHANICAL FEATURES The steam turbine is subjected to many hot and warm start-up; each startup produces a fatigue stress damaging the rotor after some years. The target is to design the turbine in order to limit the low cycle fatigue and to reduce the start-up time. Improvement may be obtained acting on: - Suitable materials to reduce the creep and fatigue. - Inner casing without big flanges but jointed with shrinking rings to reduce strains/forces due to asymmetrical thermal expansion. - The inner connection for the steam is symmetrical and distributes flow at the complete radial section of the turbine. 13

FLEXIBLE STEAM TURBINE MECHANICAL FEATURES Inner casing without big flanges but jointed with shrinking rings to reduce strains/forces due to asymmetrical thermal expansion. SHRINKING RINGS FLANGES 14

FLEXIBLE STEAM TURBINE MECHANICAL FEATURES The inner connection for the steam is symmetrical and distributes flow at the complete radial section of the turbine. STEAM ADMISSION STEAM ADMISSION 15

FLEXIBLE STEAM TURBINE MECHANICAL FEATURES Start-up Analysis The steam turbine rotor hot parts are under low cycle fatigue stress and creep. The fatigue is generated by the steam temperature variations with relevant steam flow, as during start-up phase or very high load variations (more than 50%). The creep occurs in components subjected to high temperature stresses (typically more than 500 C). Low cycle fatigue is the most important for steam turbine in combined cycle, as the request start-ups during the operation is very high. The inlet steam temperatures in HP and IP turbine sections have to follow the expected curves within tolerance of ±10 C. The steam temperature control is obtained by steam final desuperheaters, located between the HRSG and the steam turbine. 16

FLEXIBLE STEAM TURBINE MECHANICAL FEATURES Start-up Curves Turbine start-ups can be classified into various categories according to the thermal condition of the turbine at the start-up time. The true ruling criteria are the thermal temperatures to which the various components have cooled. The typical start-up categories are: cold, warm and hot. To optimize the turbine start-up time Ansaldo has introduced four steam turbine thermal state: cold, warm-cold, warm and hot. 17

FLEXIBLE STEAM TURBINE MECHANICAL FEATURES Start-up Curves START-UP SHUTDOWN TIME METAL TEMPERATURE COLD HOURS >72 TEMP<150 C WARM-COLD 48<HOURS<72 150 C<TEMP<190 C WARM 8<HOURS<48 190 C<TEMP<320 C HOT HOURS<8 TEMP>320 C 18

FLEXIBLE STEAM TURBINE MECHANICAL FEATURES Start-up Curves Cold Metal Temp.< 150 C [%] Time [min] 19

FLEXIBLE STEAM TURBINE MECHANICAL FEATURES Start-up Curves Cold-Warm 150 C <Metal Temp.< 190 C [%] Time [min] 20

FLEXIBLE STEAM TURBINE MECHANICAL FEATURES Start-up Curves Warm 190 C < Metal Temp. < 320 C [%] Time [min] 21

FLEXIBLE STEAM TURBINE MECHANICAL FEATURES Start-up Curves Hot 320 C < Metal Temp. [%] Time [min] 22

Shut-down Analysis FLEXIBLE STEAM TURBINE MECHANICAL FEATURES It is important to maintain the heat during the shut-down phase in order to perform the start-ups after night standstill or weekend standstill limiting the start-up time and the related fatigue stress. The recommended solution is to reduce the steam flow (maximum 10%/minute) by closing the turbine valves while the gas turbine still produces hot burnt gases, maintaining the vacuum in the condenser and in the gland steam after turbine trip; hence it is possible to reduce the heat lost by the IP rotor to the condenser 23

Shut-down Curves FLEXIBLE STEAM TURBINE MECHANICAL FEATURES 24

INDEX SCENARIO PLANT FLEXIBILITY FLEXIBLE STEAM TURBINE MECHANICAL FEATURES FLEXIBLE STEAM TURBINE FUNCTIONAL FEATURES CONCLUSION 25

ST automatic start-up Scope: Repeatable start-up Reduced start-up times How: FLEXIBLE STEAM TURBINE FUNCTIONAL FEATURES To operate in automatic mode, the control functions related to the process systems of the steam turbine are divided in hierarchically way: Turbine Run up (TRU) is the general sequence that manages the start up and shut down of the machine. Functional group (FG) collects open and close loop of the same auxiliary process system. Drive control level. 26

ST RSE Improvement Scope: FLEXIBLE STEAM TURBINE FUNCTIONAL FEATURES Minimize the stresses on equipment brought by the frequent changes in operating conditions Optimize operating cycle conditions in order to reduce startup times How: Systematic correlation of material stress/strain with fatigue and crack initiation The «rotor stress evaluator» program include an on-line life cycle counter New approaches to turbine modeling Material of construction High temperature Geometry of components 27

FLEXIBLE STEAM TURBINE FUNCTIONAL FEATURES ST start-up Curves Development Reducing the time of start-up curves in cold mode. Supplying different modes in the selection of start-up curves: the first one named normal, to be used when it is possible to measure the time to be previsioned by the operator to guarantee the start-up is finished at a scheduled time; the second one named fast has to be used when operator needs to provide power in a very short time. Each start-up is associated with an Equivalent Operating Hours Calculator to know in real time which is the life consumption of the steam turbine. Providing a continuous modification of acceleration during run-up and gradient during load-up, instead of having a selection based on discrete values. Improving the reliability of the temperature measure used as input for the calculation of steam turbine thermal stress as steam temperature upstream stop valves. Realizing the loading-up in closed loop to follow strictly the start-up curve imposed. They are flexible solutions can be mixed together according to Customer requirements. 28

FLEXIBLE STEAM TURBINE FUNCTIONAL FEATURES ST Participation to Frequency Control Scope: Reduce the plant load gap to maintain the reserve for the primary frequency control when GT slow gradient near the rated load (plant load >98.5% during under-frequency errors) How: Operating ST in modified steam sliding pressure mode HRSG HP SH / IP RH sections pressurisation through ST inlet valves throttling 29

FLEXIBLE STEAM TURBINE FUNCTIONAL FEATURES ST Contribution to Minimum Load Operation Scope: Reduce the plant minimum load operation below 45% without increase of NOx and CO due to not requiring further GT power decrease How: Operating ST in load control loop. In this operating mode it can be selected the frequency control on the steam turbine leaving the gas turbine working at its minimum load without the disturbances generated by the grid The steam produced by HRSG and not used by the steam turbine is diverted to the condenser through the by-pass systems. 30

INDEX SCENARIO PLANT FLEXIBILITY FLEXIBLE STEAM TURBINE MECHANICAL FEATURES FLEXIBLE STEAM TURBINE FUNCTIONAL FEATURES CONCLUSION 31

CONCLUSION Ansaldo Energia has kept pace with the new demands for involving the generating units in the flexible behaviour requested by the market. A flexible steam turbine can help us to approach the most strict requirements of the combined cycle in terms of frequent and fast start up operation and for the grid frequency control. The best solution is to manage the combined cycle in two shift operation philosophy; the more start-up foreseen will not cause damages for thermal fatigue if the plant, if the steam turbine will follow the start-up curves. In case of minimum environmental load operation the steam turbine stress will be lower than in two shift operation, only when the steam temperature is maintained about at nominal value. 32

33