CLASSIFICATION OF REACTION TO FIRE FIRES-CR AUPE

Similar documents
CLASSIFICATION OF REACTION TO FIRE FIRES-CR AUPE

CLASSIFICATION OF FIRE RESISTANCE FIRES-CR AUPE

TEST REPORT FIRES-FR AUNE. Single side-hung lift landing semiautomatic door, thermally insulated with polyurethane

FIRE RESISTANCE EXPERT JUDGEMENT REPORT WITH CLASSIFICATION FIRES-JR NURE. Fire resistance shutter with retractable stairs, type LMF

CLASSIFICATION OF FIRE RESISTANCE FIRES-CR AUPE

BRE Global Classification Report

Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1: Notified Body No: Product Name:

Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1: Notified Body No: 0833 Product Name:

Additional reaction to fire classification report No K

EN Test Report

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

1 st August Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1: 2009.

Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1: Notified Body No: 0833 Product Name:

Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1: Notified Body No: 0833 Product Name:

Title: EXTENDED APPLICATION REPORT IN ACCORDANCE WITH EN/TS Notified Body No: 0833 Product Name:

Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 Notified Body No: 0833 Product Name: Type II

european fire standards and national legislation

Production Technology

Code Compliance Research Report CCRR-0228

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. WF Report Number: Test Sponsor:

Title: CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2002 Notified Body No: 0833 Product Name: Mix Report No:

CERTIFICATE. No

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

PRODUCT DATA SHEET. Sika Pyroplast Wood T with Topcoat Sika Pyroplast Wood Top T PRODUCT DESCRIPTION

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

BS 476: Part 6: Method Of Test For Fire Propagation For Products. WF Additional Report Number: Date: 18 th February 2008.

Classification of Reaction to Fire in accordance with DIN EN :

MetecnoPanel Information Guide

This classification report consists of five pages and may only be used or reproduced in its entirety.

Evidence of Performance

Kingspan KS1150 FR Product Data Sheet

WALLSPAN. Insulated Panels for a Clean World

ENV 1187: 2002 Test 4

ABOUT US METECNOPANEL

BRE Global Test Report

Revision 1 of EN Changes and News

Review of Fire Test Report

combustibility behaviour of insulation products

Review of Fire Test Report

THIS TO CERTIFY THAT. Firetek Panel. Structure - Structural Reliability

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Ronald Mark Associates Inc

CLASSIFICATION OF FIRE RESISTANCE IN ACCORDANCE WITH BS EN : A1:2009

CORE: XFLAM INTERNAL WALLS AND CEILINGS

NFP Epiradiateur Test. WF Report Number: (Issue 2) Test Sponsor: Fiba Tech Industries Limited. Date of original report:

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

PRODUCT DATA SHEET. Sika Pyroplast HW-300 PRODUCT DESCRIPTION. Transparent, water based fire protective coating system for wood, interior use

A Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation

SANDWICH PANEL BONDING BUILDING FOR THE FUTURE

AS Certified ALCADEX

ALPOLIC /fr for External Cladding

Co-ordination of the Group of Notified Bodies for the Construction Products Directive 89/106/EEC

Burtin Polymer Laboratories 2 SwRI Project No e[1]

ESR-1061 Reissued May 1, 2011 This report is subject to renewal in two years.

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Hoesch isodach integral Technical information

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Thermaflex International Holding B.V.

RESOLUTION MSC.90(71) (adopted on 21 May 1999) ADOPTION OF AMENDMENTS TO THE STANDARD FOR QUALIFYING MARINE MATERIALS FOR HIGH-SPEED CRAFT AS

TECHNICAL SCHEDULE TS46 CERTIFICATION OF WOOD BASED PANELS WITH CLASSIFICATION B/C REACTION TO FIRE PERFORMANCE

Type II Environmental Declaration according ISO 14021:2001/A1:2011

inspirational architectural façades

CLASSIFICATION OF FIRE RESISTANCE PERFORMANCE IN ACCORDANCE WITH EN : 2007

CERTIFICATE No VTT-C Date of issue

Revision 1 of EN Changes and news Klaus Berner 25. Oct. 2013

Cleanroom Systems UltraTech

Originally Issued: 08/03/2017 Revised: 02/01/2019 Valid Through: 08/31/2019

Originally Issued: 11/06/2017 Valid Through: 11/30/2018

Use of Coatings to Improve Fire Resistance of Wood

CERTIFICATE OF APPROVAL No. ME 5064 ALSTRONG ENTERPRISES INDIA (PVT) LTD

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation

ETAG 016 SELF-SUPPORTING COMPOSITE LIGHTWEIGHT PANELS PART 4:

Kingspan KS1150 FR Product Data Sheet

Kingspan KS1150 FR Product Data Sheet

Master Specification ENERTITE by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

Interam TM Endothermic Mat E-5A-4

THIS TO CERTIFY THAT. Ritek Roof Panels. Structure - Structural Reliability

Fire protection, soundproofing and thermal insulation

BRE Global Classification Report

Page No 1 Introduction... 3

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Geaves Surface Solutions Ltd

P.O. Box ZN Bleiswijk Brandpuntlaan Zuid NZ Bleiswijk The Netherlands

Cold Rooms Kide

Hoesch isowand integral Technical information

Engineered Honeycomb Solutions and Services. Rail. Honeycomb Core and Panels for Rail Vehicle Interiors

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Phenolic foam thermal insulation products for buildings and building services end use applications

Highlights of DANA Insulated Sandwich Panels

Determination and assessment of the continuous glowing combustion behaviour of building products in the SBI test method

WFRC TEST REPORT NO BS 476: Part 7: 1997 Method For Classification Of The Surface Spread Of Flame Of Products.

KS1000 FH Product Data Sheet

REQUIREMENTS FOR AMMONIA REFRIGERATION SYSTEMS AND COOLROOM CONSTRUCTION. Building Code of Australia (BCA) 2010 Compliance

EUROPEAN ORGANISATION FOR TECHNICAL APPROVALS

CERTIFICATE OF APPROVAL No. CF 5102 ETERNIT AKTIENGESELLSCHAFT

PLASTIC CHAPTER 26. SECTION 2602 DEFINITIONS Definitions. The following terms are defined in Chapter

SPECIFICATION For the Supply and Installation of BRITAL UN Four Sided Unitized Structurally Glazed Curtain Walling

Trimform for panels, purlins & gutters. No obligation consultation

BS :2005 test on a Kingspan Benchmark External Wall Insulation System

Title: WF Report No: Prepared for: International Petroleum Products Ltd Bradwell Hall Bradwell-On-Sea Essex CMO 7HX. Date: 24 th August 2015

Transcription:

CLASSIFICATION OF REACTION TO FIRE FIRES-CR-138-13-AUPE Self-supporting double skin metal faced insulating panels with PIR core, type THERMOWALL KOMBI This is an electronic version of a classification report which was made as a copy of classification report officially issued in a paper form. The electronic version of a classification report shall be used only for informative purpose. Any information listed in this classification report is the property of the sponsor and shall not be used or published without written permission. Contents of this file may only be modified by the editor i.e. FIRES, s.r.o. Batizovce. Sponsor is allowed to publish this classification report in parts only with written permission of the editor. FIRES 129/S4-10/02/2010-E-el

CLASSIFICATION OF REACTION TO FIRE IN ACCORDANCE WITH EN 13501-1 + A1: 2009 with direct field of application FIRES-CR-138-13-AUPE Name of the product: Self-supporting double skin metal faced insulating panels with PIR core, type THERMOWALL KOMBI Sponsor: Prepared by: Metecno Bausysteme GmbH Am Amselberg 1 D-99444 Blankenhain Germany FIRES, s.r.o. Approved Body No. SK01 Osloboditeľov 282 059 35 Batizovce Slovak republic Notified Body No.: 1396 Project No.: PR-13-0233 Date of issue: 11. 10. 2013 Reports: 3 Copy No.: 2 Distribution list: Copy No. 1 Copy No. 2 Copy No. 3 FIRES, s. r. o., Osloboditeľov 282, 059 35 Batizovce, Slovak republic (electronic version) Metecno Bausysteme GmbH, Am Amselberg 1, D-99444 Blankenhain, Germany (electronic version) Metecno Bausysteme GmbH, Am Amselberg 1, D-99444 Blankenhain, Germany This classification report consists of 4 pages and may only be used or reproduced in its entirety. This report includes accreditation mark SNAS with additional mark ILAC-MRA. SNAS is signatory of ILAC-MRA, Mutual recognition agreement (of accreditation), which is focused on promoting of international acceptance of accredited laboratory data and reducing technical barriers to trade, such as the retesting of products on markets of signatories. More information about ILAC-MRA is on www.ilac.org. Signatories of ILAC-MRA are e.g. SNAS (Slovakia), CAI (Czech Republic), PCA (Poland), DakkS (Germany) or BMWA (Austria). Up to date list of ILAC-MRA signatories is on www.ilac.org/documents/mra_signatories.pdf. FIRES, s.r.o. Batizovce is full member of EGOLF also, more information www.egolf.org.uk. FIRES 049/S2-27/10/2009-E FIRES, s.r.o., Osloboditeľov 282, 059 35 Batizovce, Slovak republic tel. 00421 52 775 22 98, fax. 00421 52 788 14 12, www.fires.sk Notified Body No. 1396, Approved Body No. SK01, Member of EGOLF

1. INTRODUCTION This classification report defines the reaction to fire classification assigned to element: Self-supporting double skin metal faced insulating panels with PIR core, type THERMOWALL KOMBI in accordance with the procedures given in EN 13501-1 + A1: 2009. 2. DETAILS OF CLASSIFIED PRODUCT 2.1 GENERAL The element Self-supporting double skin metal faced insulating panels with PIR core, type THERMOWALL KOMBI is defined as an insulating panel according to EN 14509: 2006/ AC: 2008. 2.2 PRODUCT DESCRIPTION Product is insulating panels with PIR foam core and both side faced with steel sheets. Core: rigid polyisocyanurate foam type Metecno System 11 (BASF Elastopir 1132/501), density 38 ± 4 kg.m -3 (manufacturer: BASF Polyurethanes GmbH, Germany). Steel sheets: - exterior steel sheet 0,5 mm thick, grade of metal S280GD (manufacturer: ArcelorMittal, Belgium) coated on the back-side with epoxy resin-based back-coats 7 μm thick and on the top-side with polyester based top coat 25 μm thick (primer 5 μm thick and finishing coats 20 μm thick), profile geometry: flat; - interior steel sheet 0,4 mm thick, grade of metal S280GD (manufacturer: ArcelorMittal, Belgium) coated on the back-side with epoxy resin-based back-coats 7 μm thick and on the top-side with polyester based top coat 25 μm thick (primer 5 μm thick and finishing coats 20 μm thick), profile geometry: flat. Minimum thickness of panels is 85 mm. 3. TEST REPORTS IN SUPPORT OF CLASSIFICATION 3.1 TEST REPORTS No. Name of laboratory Name of sponsor Test report No. Date of the test Test method [1] FIRES, s.r.o., Batizovce, SK Metecno Bausysteme GmbH, Germany FIRES-RF-068-13- AUNE 12. 06. 2013 EN ISO 11925-2: 2010 / AC: 2011 [2] FIRES, s.r.o., Batizovce, SK Metecno Bausysteme GmbH, Germany FIRES-RF-074-13- AUNE 13. 02. 2013 04. 06. 2013 EN 13823: 2010 [1] - [2] test specimens were conditioned according to EN 13238 before the reaction to fire tests [1] specimens were cut in longitudinal and crosswise direction and tested to the main surface, bottom edge and to the bottom edge in the middle of insulation thickness (specimens turned 90 ), edges unprotected [2] tested thickness of tested panels 100 mm FIRES 049/S2-27/10/2009-E Page: 2

3.2 TEST RESULTS Test report number and test method [1] EN ISO 11925-2 surface/edge attack 1) (exposure time 30 s) flaming 1) [2] EN 13823 Characteristic value F s 150 mm Number of tests 18 Results Continuous parameter - mean (m) Compliance with parameters (-) compliant ignition of the paper (-) non-compliant FIGRA 0,2MJ 22,2 (-) FIGRA 0,4MJ 19,3 (-) LFS<edge of specimen (-) compliant THR 600s 3 1,7 (-) SMOGRA (m 2 /s 2 ) 3,6 (-) TSP600s (m 2 ) 47,6 (-) flaming no flaming non-compliant Specimens main surface (from exterior and interior steel sheet face), bottom edge (bottom part of specimens from exterior and interior steel sheet face) and specimens middle of the insulation thickness with specimens turned 90 were exposed to flame. 4. CLASSIFICATION AND FIELD OF APPLICATION 4.1 REFERENCE OF CLASSIFICATION This classification has been carried out in accordance with Clause 11.6 of STN EN 13501-1 + A1: 2010. 4.2 Classification The product, Self-supporting double skin metal faced insulating panels with PIR core, type THERMOWALL KOMBI, in relation to its reaction to fire behaviour is classified: The additional classification in relation to smoke production is: The additional classification in relation to flaming is: B s1 d0 The format of the reaction to fire classification for construction products excluding floorings is: Fire behaviour Smoke production Flaming droplets B - s 1, d 0 Reaction to fire classification: B s1, d0 FIRES 049/S2-27/10/2009-E Page: 3

4.3 FIELD OF APPLICATION This classification is valid for the following end use applications: i) external walls (classification valid for both sides); ii) partitions (classification valid for both sides); iii) ceilings (classification valid for both sides); iv) characteristic product orientation: vertical or horizontal, with front face to free area; v) characteristic position in relation to other products: with no product directly after or before it; vi) edges unprotected with flashings, or all end use applications of edges and corners protections are permitted. This classification is also valid for the following product parameters: Parameter Factors Validity of test / tests Grade of metal Valid for all grades of tested metal type Thickness of metal facing excluding organic coatings Thickness of 0,4 mm and up to 0,8 mm Metal facings Joint design Seals and gaskets Insulating core Thickness of panel Orientation of panels Metal corner flashings Fixings for metal flashings Protection over cut edges Profile geometry of inside facing Surface coating tested face Colour of coating Seals and gaskets All types of flat or light profile All coatings in the range (0 4) MJ/m 2 or all coatings with PCS values lower than that tested within manufacturing tolerances All colours Valid within normal tolerances, not valid for changes of shape or configuration no gaskets and seals Chemical composition Same chemical system of PIR and same blowing agent Density Valid for tested density 38 kg.m -3 ± 15 % Vertical or horizontal application of sandwich panels Standard spacing is 400 mm No flashings in EN ISO 11925-2 Minimum thickness of panels 85 mm Horizontally or vertically installed all panels and ceiling applications Results are valid for any metal flashing of greater thickness or dimension used in practice as was tested Valid for fixing spacing of 400 mm or less All end use applications 5. LIMITATIONS This classification document does not represent type approval or certification of the product. The classification is valid provided that the product, field of application and standards and regulations are not changed. Approved: Signed: Ing. Štefan Rástocký leader of the testing laboratory Ing. Samuel Skokan technician of the testing laboratory FIRES 049/S2-27/10/2009-E Page: 4