Fenton's catalytic oxidation process to treat landfill leachate

Similar documents
DECOLOURISATION OF REACTIVE BLUE 28 FROM DYE WASTE WATER BY PHOTO FENTON PROCESS AND SONO FENTON PROCESSES

Investigation of Color Removal of Sunflower Oil Industrial Wastewater with Fenton Process

Overcoming UV Interference in Leachate Discharges

HKICEAS-671 Optimization of Reactive Dyes Degradation by Fenton oxidation Using Response Surface Method

Long Term Treatment and Disposal of Landfill Leachate. Debra R. Reinhart Nicole Berge Eyad Batarseh University of Central Florida

Fenton Oxidation Process Control Using Oxidation-reduction Potential Measurement for Pigment Wastewater Treatment

SWANA 2017 Leachate Basics and Quality Changes with Organics Removal. Steve Johnson M.Eng., P.Eng.

INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCES Volume 6, No 6, Copyright by the authors - Licensee IPA- Under Creative Commons license 3.

BIOTECTOR TOC Analysers

Original Research The Modified Fenton Process for Decolorization of Dye Wastewater. K. Barbusiński*

TREATMENT OF TEXTILE EFFLUENT USING PHOTO-FENTON PROCESS IN PRESENCE OF BANANA PEEL AS AN ADSORBENT

Treatability studies on bleach effluent of pulp and paper industry by ultraviolet/hydrogen peroxide process with titanium dioxide as catalyst

APPLICATION OF HUMATE SUSTAINABLE ALTERNATIVE FOR REMEDIATION OF WASTEWATER AND GROUNDWATER

W12A Landfill Groundwater, Leachate, Water Well, Landfill Gas and Surface Water Quality Monitoring Program

Distillery Wastewater Decontamination by the Fenton Advanced Oxidation Method

Available online at Scholars Research Library. Archives of Applied Science Research, 2011, 3 (2):

Treatment of landfill leachate from Fez city (Morocco) using Fenton and photo-fenton processes

Using an anodic Fenton process for degradation of nitrobenzene in waste water

Study On Treatment Of Municipal Solid Waste Landfill Leachate By Fenton Process

Removing Heavy Metals from Wastewater

Wastewater treatment by ozonation

REDUCTION OF COD IN WASTEWATER FROM A TEXTILE INDUSTRY BY ELECTRO-FENTON PROCESS

A Research on treatability of leather industry wastewater by using electro-fenton process

SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS

Pilot Study on Advanced Treatment of Wastewater Produced by Pressurized Coarse Coal Gasification

Treatment of Municipal Landfill Leachate by Oxidants

Disposal of Sludge with Solid Wastes in Aerobic and Anaerobic Landfill Areas

Complete oxidation of organic substances in wastewater using an Advanced Oxidation Process with synthetic diamond electrodes

Application of a hybrid Electrocoagulation-Fenton process in yarn dye wastewater: Kinetic study

Reduction of Biochemical Oxygen Demand and Chemical Oxygen Demand of Metalworking Fluid Wastewater by Electrochemical Oxidation

Remediation of 1, 4-Dioxane

Pelagia Research Library

International Journal of Science, Environment and Technology, Vol. 4, No 5, 2015,

OXIDATIVE TREATMENT BY HYDROGEN PEROXIDE FOR THE REMOVAL OF COD AND SULPHIDE FROM TANNERY LIMING WASTEWATER

Liquid Phase Collection System Odor Control 101

Chapter 4: Advanced Wastewater Treatment for Phosphorous Removal

Evolution of Leachate Composition In a Calgary Landfill. Sean Buckles, M.Sc., P.Eng.

Photolysis, Sonolysis and Ozonolysis for Degradation of 2,4-dichlorophenoxyacetic acid (2,4-D)

Q1. From the following list of substances, choose the substances which meet the description given in parts (i) to (v) below :

DECOLORIZATION AND BIODEGRADABILITY OF DYEING WASTEWATER TREATED BY A TIO 2 -SENSITIZED PHOTOOXIDATION PROCESS

OBG WASTE MANAGEMENT PRESENTS: 18 th Annual New England Pretreatment Coordinators Workshop (October 27, 2016) Landfill Leachate Overview Mark Greene,

Fate of Organic Matter from Leachate Discharged to Wastewater Treatment Plants

Study on Effect of Soy sauce wastewater by SBR process Jinlong Zuo1, Xiaoyue Wang1, Xinguo Yang1,Daxiang Chen1,Xuming Wang2*

CE 370. Wastewater Characteristics. Quality. Wastewater Quality. The degree of treatment depends on: Impurities come from:

operation of continuous and batch reactors. Contrary to what happens in the batch reactor, the substrate (BOD) of the wastewater in the continuous rea

Wastewater chemically enhanced primary treatment combined with adsorption of activated sludge: AS-CEPT in wastewater treatment

ICSE-Science 2 (Chemistry) 1996

Advanced Reduction Processes for Water and Wastewater Treatment

What is: (a) aqua fortis, (b) aqua regia (c) Fixation of Nitrogen?

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

Kirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent

Advanced Oxidation Process Basics and Emerging Applications in Water Treatment

Photo-Oxidation Process Application for Removal of Color from Textile Industry Effluent

Removal of COD and Colour from Sanitary Landfill Leachate by using Coagulation Fenton s Process

Advanced Oxidation Processes: Treatment of 1,4-Dioxane and VOCs for Potable Water Applications

DR 1900 PORTABLE SPECTROPHOTOMETER

International Journal of Advance Research in Engineering, Science & Technology

Cyanide Concentration Changes in Environmental Water Samples as a Function of Sample Preservation, and Holding Time

Abu Dhabi Trade Effluent Standards & Regulations Summary

Azmi Aris, Ooi Boon Siew, Kon Suh Kee, Zaini Ujang

International Conference on Applications of Radiation Science and Technology (ICARST-2017) April 2017, Vienna

COD. Environmental Chemistry Chemical Oxygen Demand A Conventional Perspective Lecture 8

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement

Environmental and technical evaluation of the dual use of microalgae for municipal wastewater bioremediation and sustainable biofuel production

Reactivity Series. Question Paper. Cambridge International Examinations. Score: /39. Percentage: /100

2019 Microbac Laboratories Inc. Ohio Valley Division

Lecture 7 Water Quality Monitoring: Estimation of fecal indicator bacteria

Superintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal

SUBSEQUENT FENTON PROCESS AND NEUTRALIZATION FOR WASTEWATER TREATMENT OF TEXTILE HOME INDUSTRY

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT

U. S. Army Corps of Engineers Metals Precipitation Checklist

Know What You re Monitoring! Since not all of us are water chemists, here is a brief understanding of what your different tools measure

Discoloration of Azo Dye Acid Red 18 by Fenton Reagent in the Presence of Iron Powder

Department of Civil Engineering, IIT Delhi (India) CVL722 (Sem1, ) (Dr. Arun Kumar;

TEXTILE INDUSTRY AND ENVIRONMENT. W.J.K.Dushyanthi Ranpatige Research Officer Industrial Technology Institute

Advanced Treatment of Pistachio Processing Industry Wastewater by Fenton Process

Removal of Dye from Textile Wastewater by Electrolytic Treatment

Advanced Oxidation Processes for Wastewater Treatment in the Pulp and Paper Industry: A Review

ICSE-Science 2 (Chemistry) 2000

WEDECO MiPRO ThE RighT ADvAnCED OxiDATiOn SOluTiOn for Any kind Of MiCROPOlluTAnTS

NAPHTHA REMOVAL FROM PETROLEUM INDUSTRIAL EFFLUENT

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline

L o g o. Chemical and biological treatment of produced water for sustainable operation of oil shales and similar operations

Department of Civil Engineering-I.I.T. Delhi CVL723 Problem Set_2_Feb6_15

Chemical Test Kits. Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits

WASTEWATER FROM CARBON CAPTURE SPECIAL CONSIDERATIONS FOR WASTEWATER TREATMENT

Lecture 1: Introduction

Wastewater Treatment Processes

Water Quality. CE 370 Lecture 1. Global Distribution of Earth s s Water

In-Situ Chemical Oxidation DOUG HAMILTON, PRINCIPAL HYDROGEOLOGIST ACV ENVIRO

E-beam Treatment of Toxic Wastes; The Experiences in Pilot and Industrial Scale Plant

Appendix C1: Batch Kinetics Tests

Characterization of Ammonia Removal from Municipal Wastewater Using Microwave Energy: Batch Experiment

Analysis of dissolved nitrite (NO 2- )

Aerobic Sludge Digestion in the Presence of Chemical Oxidizing Agents Part II. Fenton's Reagent

Journal of Chemical and Pharmaceutical Research, 2014, 6(7): Research Article

Composting Plant Leachate Treatment by Coagulation-Flocculation Process

Decolorization of simulated spent reactive dye bath using solar / TiO 2

AUTOMATED WATER ANALYSIS

Disinfection of Total Coli-forms in the Effluent from Municipal Wastewater Plant with e- Beam. June 07, EB TECH Co.

Transcription:

JIChEC6 12-14 March 212, Amman, Jordan Fenton's catalytic oxidation process to treat landfill leachate Ahmad Mashal a*, Jehad Abu-Daherieh a, Mohammad Ahmad a, Farid Aiouache a and David Rooney a. a School of Chemistry and Chemical Engineering, QUEEN'S UNIVERSITY BELFAST Belfast, BT9 5AG, Northern Ireland, UK. *E-mail: amashal1@qub.ac.uk Abstract Many types of advanced oxidation processes (AOPs), namely Fenton (Fe 2+ /H 2 O 2 ) with different doses, Fenton-like (UV/Fe 2+ /H 2 O 2 ), photo-fenton (Fe 2+ /H 2 O 2 /TiO 2 ), and plasma technology have been investigated for the removal of organic matters (COD content) from landfill leachate. Fenton's oxidation was the most effective as the most effective ratio 1/1 (Fe 2+ /H 2 O 2 ) which allow the COD removal reached 5-8% and the biodegradability increased by 4 to 6 %. The leachate was characterised by high COD, the synthetic feed to simulate the composition of domestic landfill leachate which the main source of COD is the Glucose. The oxidation by batch treatment was performed on different synthetic leachate concentrations and two types of doses: (single, triple and high) Fenton s reagents. The first single Fenton s reagent removal efficiency of COD was less than those of a triple Fenton s reagents for all tested leachates under similar operating conditions. But the removal efficiency of COD by using the high dose of Fenton regent was the highest percent which remove up to 9% of original COD. The COD removal of domestic landfill leachate and a glucose based-synthetic one as a function of the operating variables (H 2 O 2, Fe 2+, TiO 2, UV (4watt) and Plasma technology) led to results that ranged between 3% and 9% while the removal efficiencies decreased in the order: Fenton of high dose > Plasma > Fenton of triple dose > Fenton of single dose > photo-fenton > Fentonlike > UV/Fe 2+ /H 2 O 2. Fenton process however generated an important quantity of iron sludge which will require further disposal, when performed under optimal COD removal conditions. Keywords: Batch Reactor, Landfill Leachate, Fenton Reagent, Solid waste, Oxidation Process. 1. Introduction: Municipal landfill leachates are considered one of the types of wastewater with the greatest environmental impact. The most critical aspects of leachates are linked to the high concentrations of several pollutants. Municipal landfill leachates contain pollutants that can be divided into four main groups: 1) Dissolved organic matter; 2) Inorganic compounds, such as ammonium, calcium, magnesium, sodium, potassium, iron, sulphates, chlorides; heavy metals, such as cadmium, chromium, copper, lead, nickel, zinc; and xenobiotic organic substances. 3) Organic materials found in landfill leachates are typically volatile fatty acids such as humic and fulvic compounds. 4) Xenobiotic organic compounds coming from household or industrial chemicals are present in very low concentrations (usually lower than 1 mg/l). These compounds include among others a variety of aromatic hydrocarbons, phenols, chlorinated aliphatics, pesticides, and plastizers. The composition of landfill leachates varies depending on the nature of the deposited wastes, on soil characteristics, rainfall patterns and on the age of the landfill. Usually, in young landfill leachates the dissolved organic matter is mostly made up of volatile fatty acids (i.e. a high BOD/COD ratio) that decrease with increasing landfill age as a result of the anaerobic decomposition that takes place in the landfill site. As the volatile fatty acid leachate content decreases, the BOD/COD ratio, i.e. the concentration of more refractory compounds such as high molecular weight humic and fulviclike material, decreases. The implementation of the most appropriate technique for the treatment of leachates depends upon the specific characteristics of the particular waste stream; biological processes are quite effective, when applied to relatively young or freshly produced leachates, but they are less efficient for the treatment of older leachates, while physical chemical methods are not favored for the treatment of young leachates. [Enviros Consulting (27)]. In groundwaters the risk arises from the migration of leachate contamination into water supplies where the presence of ammoniacal nitrogen is and even its breakdown product nitrate will render the groundwater unsuitable for drinking. 2. Advanced Oxidation Processes: A lot of types of advanced oxidation processes (AOPs), namely photo-fenton, Fenton-like,

JIChEC6 12-14 March 212, Amman, Jordan Fenton and UV/H 2 O 2, have been investigated in many studies in the removal of organic matter and colour from landfill leachates. The leachate was characterised by high COD, low biodegradability and intense dark colour. Fenton's oxidation is one of the most effective among all used treatment procedures. Major factors that affect the performance of the Fenton process were as follows: (1) hydraulic retention time, (2) reaction time, (3) reaction ph, (4) hydrogen peroxide to ferrous iron mole ratio,(5) initial COD, (6) ferrous iron dosage, (7) temperature, (8) final ph and (9) age of leachate. Several alternatives combination of Fenton, Fenton-like and photo-fenton have been for the treatment of model Landfill leachate. Typical Fenton Processes can be divided into: Normal Fenton with different Dosing system (Fe 2+ /H 2 O 2 with a single feed, multi feed and High feed processes), (TiO 2 /O 2 /Fe 2+ /H 2 O 2 heterogeneous systems), (H 2 O 2 / Fe 2+ /UV photo-fenton), and (O 3 /Fe 2+ /H 2 O 2 homogenous system). Fenton process has been widely used to treat landfill leachate. It depends on the type of leachate which will be the fresh leachate for young one and the mature leachate for non volatile one. The methodology will be used to study the main variables affecting the Fenton process as well as their most relevant interactions. Fenton process generated an important quantity of iron sludge, which will require further disposal, when performed under optimal COD removal conditions. Furthermore conventional Fenton process was able to achieve slightly over an 8% COD removal from a young leachate, while for old and mixed leachates was close to a 7%. The main advantage showed by the photo-assisted Fenton treatment of landfill leachate was that it consumed 32 times less iron and produced 25 times less sludge volume yielding the same COD removal results than a conventional Fenton treatment. The treatment of synthetic leachate solutions was studied in a bench-scale continuous stirred tank reactor, under Fe 2+ catalyst and hydrogen peroxide oxidation conditions and optimized mole ratio of reagents Fe 2+ / H 2 O 2. The initial concentrations of COD varied from 5 to 2, and, an optimal ratio of COD/N/P of 1/4.2/2.5 was used. The removal efficiency of COD was ranging between 2 and 9% for most of the tested leachates and a maximum value of 91% was reached when using a high Fenton reagent dose. That would conclude that at high COD concentrations, the time of treatment would not be affected by the removal Process of COD when using large amount of catalyst. The effect of different treatment types and operating conditions were studied and examined in order to establish the most efficient configuration of leachate treatment. The main Fenton Process as which have been used as Normal Fenton with different dosing system are (Fe 2+ /H 2 O 2 with a single feed; multi feed and High feed processes; TiO 2 /O 2 /Fe 2+ /H 2 O 2 heterogeneous systems; H 2 O 2 / Fe 2+ /UV photo- Fenton; and O 3 /Fe 2+ /H 2 O 2 homogenous system. 3. Fenton s Chemistry The Fenton and related reactions are potentially convenient ways to generate oxidizing species for pollutants degradation (Pignatello et al., 26). Fenton process extends multiple benefits such as both iron and hydrogen peroxide are relatively cheap and safe, there is no mass transfer limitation except during coagulation where a high dosage of activator-ferrous salts is used and the process is technologically simple. The classical Fenton process involves the sequence of following reactions. Fe 2+ + H 2 O 2 Fe 3+ + OH + OH (3.1) Fe 3+ + H 2 O 2 Fe 2+ + HO 2 + H + (3.2) k 2 =.1.1 M 1 s 1 (Walling & Goosen, 1973) H 2 O 2 + OH HO 2 + H 2 O (3.3) k 3 = 3.3 1 7 M 1 s 1 (Buxton & Greenstock, 1988) Fe 2+ + OH Fe 3+ + OH (3.4) k 4 = 3.2 1 8 M 1 s 1 (Buxton & Greenstock, 1988) Fe 3+ + HO 2 Fe 2+ + O 2 H + (3.5) k 5 2. 1 3 M 1 s 1 (De Laat and Gallard, 1999) Fe 2+ + HO 2 + H + Fe 3+ + H 2 O 2 (3.6) k 6 = 1.2 1 6 M 1 s 1 (Bielski et al., 1985) HO 2 + HO 2 H 2 O 2 + O 2 k 7 = 8.3 1 5 M 1 s 1 (3.7) The generation of hydroxyl radicals Equation (3.1) is very rapid. The net reaction Equations

JIChEC6 12-14 March 212, Amman, Jordan (3.1 3.7) can be defined as the dissociation of H 2 O 2 in the presence of iron as catalyst: 2 Fe 2+ + H 2 O 2 +2 H + 2 Fe 3+ + 2 H 2 O (3.8) Equation (3.8) implies that the reaction is completed under acidic conditions i.e. the presence of H + ions is necessary for the decomposition of H 2 O 2. Iron plays the role of catalyst in the above reactions by changing form between Fe 2+ and Fe 3+. 4. Material and methods: In this work, prepared Synthetic wastewater samples were used to simulate the real case and conditions of Landfill Leachate. Simple Fenton oxidation was used with Fe 2+ catalyst and hydrogen peroxide H 2 O 2 (3% w/v, p.a.). The completely-batch reactor (BR) experiments were carried out using a one-liter reactor. Mixing was provided by a variable speed motor connected One-blade propeller. It was vertically mounted above one propeller diameter from the tank bottom. Mixing speed was about 1-2 rpm. The acidic condition on the reactor was controlled by ph controller using buffer solution. The reactor temperature was maintained 2 ± 1 C. The aqueous solution of Fenton reagent and diluted broth was stirred (1-2 rpm) during the reaction period up to 3 min. Also, the volume of the reaction prepared is about 1L to 2L in the all cases. 1 ml of the sample has been redrawn every 5 or 1 min for 3 min and COD, ph and concentration of ammonium nitrogen were determined immediately. Synthetic feeds: Synthetic wastewater was prepared to simulate the composition of domestic waste water system or sanitary landfill effluent. Hach meter DR/21 or DR/28 is manufactured by the Hach Company, Germany. The DR/21 is a microprocessor-controlled, single beam spectrophotometer designed for colorimetric testing in the field or the laboratory. With a measurement range of 4 to 9 nm, the DR/21 provides results in concentration units, percent transmittance (%T), and absorbance (ABS) units. There are factory-installed preprogrammed calibrations for more than 12 common water quality tests (Hach Company, 2). The following analytical methods are carried out using Hach spectrophometer DR/21: 1) Chemical Oxygen Demand Analysis 2) Ammonia Analysis 3) Nitrate Analysis 5. Results and Discussion In this section, the study of the performance and removal efficiency for different COD concentration by using different catalysis processes was preceded as follow: 1) Normal Fenton with three different dosing ratios (Fe 2+ /H 2 O 2 Fenton Reagent): in this case the performance of the Fenton process for different dosing ratios was studied as part of pure Fenton process without additional catalysts. A) Single feed of the catalyst as one time per reaction; B) Multi feed of the catalyst by adding Fenton Reagent Fe 2+ /H 2 O 2 at three stages at t=, t=12min and t=22min. This is in order to enhance the performance and decrease the effect of limiting reaction step if is it from the catalyst initial dose. C) High feed of catalyst system with three times the amount of catalyst used in (A) at the starting time of the reaction t=. 2) TiO 2 /O 2 /Fe 2+ /H 2 O 2 heterogeneous system: In this system the effect of adding titanium dioxide as third catalysis on the performance of the whole process was studied under the same condition as those used in the Fenton reaction. 3) H 2 O 2 / Fe 2+ /UV photo-fenton: In this case the photo catalysis as additional force was added to the Fenton system to enhance the performance of COD reduction. 4) O 3 /Fe 2+ /H 2 O 2 homogenous system: In this case, ozone was added as additional catalyst to the Fenton reagent reaction as strong oxidant catalyst. 5.1 COD removal by Basic Fenton s Reagent treatment (Single Dose) For a single Fenton dose process treatment, the mole ratio of H 2 O 2 and Fe 2+ was very important for overall reactions and overall removal efficiency. Figure (5.1) shows the effect of initial COD concentration on COD removal by using basic Fenton's catalytic process as function of time. From this figure, it is clear that the reduction of COD concentration follows a first order decay at the beginning in which the

Percent, % COD, JIChEC6 12-14 March 212, Amman, Jordan concentration decreased in the first 15 min by 3% and thereafter kept constant with an overall removal of about 3-4%. It can be seen also that for initial COD of 1229 and 1293 the data is reproducible and the system used for leachates treatment is stable for different runs under the same conditions. 14 88 12 1 111 8 318 6 384 4 63 2 1122 mg 1229 mg 1 2 3 4 5 6 7 time (min) Fig. (5.1): Effect of initial COD conc. by using basic Fenton's process. 4 63 3 1122 2 1229 1 1293 1 2 3 4 5 6 7 Fig. (5.2): Percentage reduction in COD conc. using basic Fenton's catalytic process at different initial COD concentration. maximum value of 55% and then kept constant after almost 2 minutes. 5.2 COD removal by Fenton s reagent treatment with three dosages The process for the removal efficiencies of COD of oxidation reaction (Fenton s catalytic process) treatment using three doses stages and at different initial concentrations is illustrated in Figure (5.2). The addition of the catalysis reagents into the batch reactor through three different doses at starting time (t=) first dose, at (t=12min) the second dose and at (t=22min) the final dose. The catalyst pair was set as one catalyst conjugates of (H 2 O 2 and Fe 2+ ). Also the oxidation reaction was extended to longer times to enhance the performance for overall COD reduction and to minimize the catalysis concentration limiting step if is it from initial catalyst feed. For the triple feeding system is equivalent to three batch reactor s in series as because the reaction goes forward with the time as a new feed of catalyst was added to the reaction vessel. In Figure (5.2), the COD initial concentration varied from 3, to 15,. For that the initial concentration COD was started with high COD contents in the reaction feed (modelled leachate) to allow enough leachate to react with the catalyst and prevent shortage in feed concentration. The initial COD concentration reduction was about 2-5 in each reaction run for example at the COD concentration 16,, the final COD concentration was about 11,. After 35-4 minutes the COD content reached a plateau value with an overall reduction of ranging from 3 to 8% of COD content. It is noticed also that for all experiments that the reaction time increased to 3 minutes which is three times the reaction time used in the single dose reaction run. Fig. (5.2) shows the percentage reduction in COD concentration using basic Fenton's catalytic process at different initial COD concentration as function of time. In general, the removal efficiency of COD using basic catalysis of Fenton reagent as a single dose system varies from 15% to about 55% of initial COD concentration. The overall percentage removal by the single dose Fenton s oxidation process increased rapidly reaching average values of 25-3% with

COD, Percent, % COD, JIChEC6 12-14 March 212, Amman, Jordan 2 18 16 14 12 1 8 6 4 2 388m 1117 1636 1 2 3 4 185 Figure (5.3): Effect of initial COD conc. on COD removal using with three dosages. 9 388 8 423 7 COD 6 =641 5 COD =673 4 COD 3 =981 2 146 1 1117-5 5 15 25 35 1636 Fig. (5.4): Percentage reduction in COD concentration using Fenton's catalytic process with three dosages at different initial COD concentration. The removal efficiency of COD using Fenton reagent with three dosages system varied from 2% to about 78%. The removal efficiency of COD increased by 3% using three dosages Fenton s reagent. On the other side, the overall Percentage removal for the three doses Fenton s oxidation process increased gradually until reached average values of 5-75% with maximum value of 8% and then get steady after 4 minutes. The highest removal efficiency by three dosages system Fenton s reagent was done for the lowest COD content. The removal efficiency increased with decreasing initial COD concentration or the removal percentage increased. The removal percentage of the oxidation reaction (Fenton s catalytic process) using three dosages reactions are illustrated in Figure (5.4). 5.3 COD removal by Fenton s Reagent treatment (with High Feed Dose): In this case, the amount of Iron sulphate and hydrogen peroxide which are the catalyst pair of one catalyst conjugates of (H 2 O 2 and Fe 2+ ) was used. The amount of catalyst used was three times the catalyst used in single dose in the section (5.1). In Figure (5.3), the COD initial concentration varies from 1, to 13, as initial feed concentration. It is clear that for all experiments the reaction time increased to 3 minutes which is three times the reaction time used in the single dose reaction run. The high COD content was used in the starting feed to allow enough leachate to react with the catalysis and prevent shortage in the feed concentration. 14 12 1 8 6 4 2 1 2 3 4 5 Figure (5.5): Effect of initial COD conc. on COD removal with large dose. 125 387 15 1262

Percent, % JIChEC6 12-14 March 212, Amman, Jordan 1 9 8 7 6 5 4 3 2 1 125 387 15-5 5 15 25 35 1262 Fig. (5.6): Percentage reduction in COD concentration using Fenton's catalytic process with large dose at different initial COD concentration. It is noticed also from the figure that the COD concentration decreased sharply at the first 5 minutes and then decreased gradually. For instance, a reduction of 5 was observed an initial COD concentration 11,. After 4-5 minutes the COD content keep constant with an overall reduction ranging from 4 to 9% removal. The removal efficiency of COD using large amount of Fenton reagent as a high dose system varies from 2% to about 78%. The final removal efficiency of COD varied according to the initial concentration used and increased by 3% using three dosages Fenton s reagent. On the other side, the overall Percentage removal for the three doses Fenton s oxidation process increased gradually until reached average values of 4-9% with maximum value of 91% and then get steady after 45 minutes. The highest removal efficiency by high dose system Fenton s reagent was done for the lowest COD content. The removal efficiency increased with decreasing of the initial COD concentration or the removal percentage increased with the low landfill leachate load. The removal percentage of the oxidation reaction (Fenton s catalytic process) at a high dose reaction is illustrated in Figure (5.6) On the other side, the overall percentage removal for the large doses Fenton s oxidation process increased rapidly in 5 minutes a maximum value of 9% which is the best removal of landfill leachate as a single unit and without advanced combination processes. For an economical and feasible solution to treat the landfill leachate by one unit and in a short time, the 4 minutes the large dose system was found the most convenient as a whole unit. It is noticed also from the figure that the COD concentration decreased sharply at the first 5 minutes and then decreased gradually. For instance, a reduction of 5 was observed an initial COD concentration 11,. After 4-5 minutes the COD content keep constant with an overall reduction ranging from 4 to 9% removal. The removal efficiency of COD using large amount of Fenton reagent as a high dose system varies from 2% to about 78%. The final removal efficiency of COD varied according to the initial concentration used and increased by 3% using three dosages Fenton s reagent. On the other side, the overall Percentage removal for the three doses Fenton s oxidation process increased gradually until reached average values of 4-9% with maximum value of 91% and then get steady after 45 minutes. The highest removal efficiency by high dose system Fenton s reagent was done for the lowest COD content. The removal efficiency increased with decreasing of the initial COD concentration or the removal percentage increased with the low landfill leachate load. On the other side, the overall percentage removal for the large doses Fenton s oxidation process increased rapidly in 5 minutes a maximum value of 9% which is the best removal of landfill leachate as a single unit and without advanced combination processes. For an economical and feasible solution to treat the landfill leachate by one unit and in a short time, the 4 minutes the large dose system was found the most convenient as a whole unit. 5.4 COD removal by Fenton s Reagent treatment with Titanium Dioxide and Air flow In this section, titanium dioxide TiO 2 as one of Fenton s supporting catalysis is used to treat the modelled landfill leachate in presence of air flow. The process parameters studied are f the same as those of the standard Fenton catalytic reaction. In Figure (5.7), the COD initial concentration was varied from 83 to 12, as initial feed concentration. The period of reaction time increased over the first 25-3 minutes. The COD concentration reduction did not exceed 2 in some of reaction runs as illustrated by the initial COD concentration 8,

COD, Percent, % JIChEC6 12-14 March 212, Amman, Jordan, which reached a final value of 6,. After 2 minutes the COD content kept constant with an overall COD removal ranging from 4 to 5% of the initial content. 14 12 1 8 6 4 2 83m /l with 1gm TD 13 with.5td 15 with 1gm 2 with.5td 278 with.5 gm TD 778 with.5gm TD 5 45 4 35 3 25 2 15 1 5 1 2 3 4 13 15 778 1161 1218 Figure (5.8): Percentage reduction in COD concentration using Fenton's catalytic process with titanium dioxide and air flow at different initial COD. 1 2 3 5.5 COD removal by Fenton s reagent treatment with UV Lamp (Photo-Fenton) Figure (5.7): Effect of initial COD concentration on COD removal using Fenton s reagent with titanium dioxide & air. The removal efficiency of COD using the supporting catalysts, titanium dioxide TiO 2 a companied with the Fenton reagent Fe 2+ /H 2 O 2, varied from 8% to about 55%. The overall percentage removal for the three doses Fenton s oxidation process increased rapidly until it reached average values of 5-5% with maximum value of 55% and then kept constant after 3 minutes. The highest removal efficiency by high dose system Fenton s reagent was achieved for the lowest COD content. The removal efficiency increased with decreasing of the initial COD concentration or the removal percentage increased with the low landfill leachate load. The removal percentage of the TiO 2 /Fe 2+ /H 2 O 2 Fenton s catalytic process reactions are illustrated in Figure (5.8). The photo-assisted Fenton reaction (photo- Fenton) is a strongly enhanced version of the Fenton catalytic process. The positive effect of irradiation on the degradation rate is due to the photochemical regeneration of ferrous ions (Fe 2+ ) by the photo-reduction of ferric ions (Fe 3+ ), with the production of additional OH radicals: Fe 3+ + H 2 O H + +Fe (OH) 2+ + hν H + + OH + Fe 2+ (5.2) The photochemical reactor after batch reactor stage consisted one serial Pyrex glass vessel with an illuminated volume of 1 ml. The Pyrex vessels were irradiated from the outside with a UV lamp system (lamp has a wavelength 4 Watt) with an irradiation intensity of 4 W m 2. The photochemical reactor was used for 1.5 hour after the Fenton catalytic reaction done. When the oxidation was carried out using only UV radiation, the reduction of organic compounds concentration expressed as COD was less than 3% after 1 h of treatment. UV photolysis without addition of any catalyst or oxidant reagent showed very low degradation efficiency so it is not a suitable treatment.

COD, JIChEC6 12-14 March 212, Amman, Jordan 21 18 15 12 9 6 3 3 5 7 9 1 1 1 1 5 1 Figure (5.1): Percentage reduction in COD concentration using photo-fenton s reagent with UV lamp and air flow at different initial COD. Figure (5.9): Effect of initial COD concentration on COD removal using photo- Fenton s reagent with UV lamp. Figure (5.9) shows the percentage reduction in COD concentration using photo-fenton s reagent with UV lamp at different initial COD concentration as function of time. In the photo-fenton process (UV/Fe 2+ /H 2 O 2 ), ferrous salt and hydrogen peroxide were two major chemicals determining operation costs and efficiency through the first 3 minutes. Then after exposure to the UV lamp for more than 6 min, the reduction of COD contents mostly steady which means the effect of UV oxidation effect on colour change from yellow to clear solution. The removal efficiency of COD using the supporting catalyst, that is, the UV photo Fenton catalyst after Fenton Reagent Fe 2+ /H 2 O 2 varied from 1% to about 55%. In the other hand, the overall Percentage removal increased sharply until reached average values of 1-55% with maximum value of 55% and then get steady state after 4 minutes. The highest removal efficiency by photo-fenton s reagent was done for the highest COD content. 5.6 COD removal by Fenton s Reagent with Ozone generated from Plasma reaction Ozone is a strong oxidiser having high reactivity and selectivity towards organic pollutants such as aromatic compounds. Furthermore, as the standard oxidation potential of the hydroxyl radical (E = 2.8 V) is much higher than that of ozone (E = 2.7 V), the use of ozone at high ph (O 3 /OH ) or in a combination with H 2 O 2 (O 3 /H 2 O 2 ) favours the production of hydroxyl radicals and accelerates the removal of recalcitrant organic matter from complex wastewater matrices. Ozonation under alkaline conditions and the combination of ozone with hydrogen peroxide have proved to be effective advanced oxidation processes for landfill leachate.

COD, Percent, % JIChEC6 12-14 March 212, Amman, Jordan 14 12 1293 3 25 13 1 8 6 4 2 11 1 2 3 4 time (min) Figure (5.11): Effect of initial COD concentration on COD removal using Fenton s reagent with ozone generated from plasma. Figure (5.11) is shown the effect of initial COD concentration on COD removal using Fenton s reagent with ozone generated from plasma. In this figure, the COD initial concentration varied from 1, to 13,. The period of operating time was increased about 2-3 dose run of O 3 /Fe 2+ /H 2 O 2 catalysis. The COD concentration reduction exceeded 2 in some of reaction runs; for example at COD concentration 13,, the final COD values was about 3,. After 2 3 minutes the COD content keep constant which it is means the reaction done over of 2 3% removal. The removal efficiency of COD using supporting catalyst, that s ozone as a strong oxidizer for the Fenton Reagent Fe 2+ /H 2 O 2 varied from 18% to about 27% of initial COD concentration. On the other hand, the overall percentage of removal for the ozone Fenton s oxidation process increased very fast until reached average values of 18 27% with maximum value of 27% and kept constant after 2-3 minutes. The highest removal efficiency by high dose system Fenton s reagent was done for the lowest COD content. In the other word, the removal efficiency increased with decreasing of the initial COD concentration or the removal percentage increased with the low landfill leachate load. The removal percentage of the Ozone Fenton s catalytic process reactions is illustrated in Figure (5.12). 2 15 1 671 5 Figure (5.12): Percentage reduction in COD concentration using Fenton's reagent with ozone generated from plasma reaction at different initial COD. 7. Conclusions: 11m g/l 671 1 2 3 4 The main objective of this study was to investigate the Fenton oxidation treatment of synthetic leachate. Such treatment was examined by a bench-scale CSTR. Fenton's oxidation was the most effective among all used treatment procedures. At the most effective ratio 1/1 (Fe 2+ /H 2 O 2 ) COD removal reached 5-8%, biodegradability has been increased. The oxidation batch treatment was performed on different synthetic leachates concentration at two different doses of (single and triple Fenton s reagent). The first single Fenton s reagent removal efficiencies of COD at 2-3 minutes reaction time were less than those of a triple Fenton s reagent at 35-4 minutes reaction time for all tested leachates and with similar condition performances for both periods of treatment. Ammonia removal efficiency did not improve with the use of oxidation process. High ammonia concentration would have an inhibition effect on the Fenton s reagent and would not be overcome with the application of advanced oxidation conditions. The removal efficiency of phosphate did not improve with the use of oxidation

JIChEC6 12-14 March 212, Amman, Jordan process. That would be as a result of the uptake of the ammonia or total nitrogen content and phosphate by Biological treatment were supported with the nitrifying/denitrifying bacteria. That would indicate that the increase of phosphate concentration caused an inhibition effect on the oxidation process. Overall, it had been shown in this study that the oxidation treatment of leachates was capable generally to reduce the influent concentrations of COD. However, the final effluent concentrations were higher than those of accepted values and consequently a post treatment should be performed before discharging to environment. Finally, it would be recommended that different types of oxidation leachate treatment and operation cycles to be used as second stage treatment method and need to examine in order to establish the most efficient configuration of leachate treatment in Batch reactor. 1) Optimised Fenton reagent mole ratios are [Fe2]/[H2O2]=1.7. 2) Among the advanced oxidation processes selected and tested under similar experimental conditions, the high Fenton reagent dose system is the most effective method to degrade aqueous solutions of modelled COD where the values exceed 9% removal. 3) Using modelling the overall reaction of Fenton catalytic processes was found to follow pseudofirst-order kinetics of decay model. 6. References: 1. Hui Zhang, Heung Jin Choi, Pat Canazo and Chin-Pao Huang, (25), Multivariate approach to the Fenton process for the treatment of landfill leachate, Journal of Hazardous Materials, B125, 166-174. 2. EPA. (211). Terminology Reference System: Leachate. U.S. Environmental Protection Agency, Washington, USA. 3. http://www.leachate.co.uk/html/all_about_leac hate.html also: www.leachate.co.uk 4. Primo, Oscar, Rivero, María J. and Ortiz Inmaculada, (28). Photo-Fenton process as an efficient alternative to the treatment of landfill leachates. Journal of Hazardous Materials, 153, (1-2), 834-842. 5. Enviros Consulting (21), About Leachate, Enviros Environmental Consultants UK, Cambridge, UK. 6. Carville, M. And Robinson, H. (25). Leachate Treatment for domestic waste landfills worldwide. Waste Management world: Technologies and Treatment. 7. Žgajnar Gotvajn, T. Tišler and J. Zagorc- Končan, (28), Comparison of different treatment strategies for industrial landfill leachate, Journal of Hazardous Materials, B136, 258-265. 8. Yang Deng, James D. Englehardt, (26), Treatment of Landfill leachate by the Fenton Process, Water Research, 4, 3683-3694. 9. Antonio Lopez, Michele Pagano, Angela Volpe and Appio Claudio Di Pinto, (23), Fenton s Pre-treatment of mature landfill leachate, Chemosphere, 54, 15-11. 1. Mohamed Ksibi, (26) Chemical oxidation with hydrogen peroxide for domestic wastewater treatment, Chemical Engineering Journal, 119, 161-165 11. Muhammad Umar, Hamidi Abdul Aziz, Mohd. Suffian Yusoff (21), Trends in the use of Fenton, electro-fenton and photo-fenton for the treatment of Landfill Leachate, Waste Management, 3, 2113-2121. 12. Bekbolet, M., Suphandag, A. S. and Uyguner, C. S. (22). An investigation of the photocatalytic efficiencies of TiO2 powders on the decolourisation of humic acids. Journal of Photochemistry and Photobiology A: Chemistry 148, (1-3), 121-128. 13. Zhang, H., Zhang, D. and Zhou, J. (26). Removal of COD from landfill leachate by electro-fenton method. Journal of Hazardous Materials, 135, (1-3), 16-111 14. Zhang, H., Choi, H. J., Canazo, P. and Huang, C.-P. (25). Multivariate approach to the Fenton process for the treatment of landfill leachate. Journal of Hazardous Materials, B125, 166-174. 15. Dague, R. R., Habben, C. E. and Pidaparti, S. R. (1992). Initial Studies on the anaerobic sequencing batch reactor, Water Sci. Tech., 26, pp 2429-243