New Research Laboratory & Given Building Renovations

Similar documents
Community Liaison Committee and Neighborhood Collaborative. American University Hall of Science. August 7, 2017

TEXAS A&M ENGINEERING

Draft Feasibility Study for the Expansion of Southeast Library

New Research Laboratory & Given Building Renovation for the Larner College of Medicine and the Department of Psychology

Science Technology Engineering and Mathematics (STEM) Initiative

date: 10 july 2012 the pennsylvania state university: burrowes building

UVM Central Utility Plant: A Half Century of Growth, Innovation, & Efficiency

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Element Z General Design Requirements Existing Facilities Information

CONCURRENT ADVERTISEMENT FOR SUBCONTRACTOR PREQUALIFICATION AND BIDS

EASTERN SE & 750 CHERRY SE - REQUEST FOR NEW BUILDINGS

Completed. Project. Melbourne High School. Comprehensive Additions and Renovations

Collaborative Life Sciences Building & Skourtes Tower

College of the Desert Athletics Facilities

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 02/06/2013 BUILDING SURVEY DATE

FACILITY DESIGN PLAN FOR HARDING HALL RENOVATION AND ADDITION SOUTH DAKOTA STATE UNIVERSITY DATE: March 29, 2017

Cone University Center HVAC Modernization Design and Construction Administration Services Code Item 320

Deferred Maintenance Plan

APPA Institute for Facilities Management

Civil District Court Parish of New Orleans. Image Courtesy of EDR MA. Renovation & Utilization Feasibility

Green Building and Operating Practices and Guidelines

Chilled Beams. The new system of choice?

SOUTH DAKOTA BOARD OF REGENTS. Budget and Finance ******************************************************************************

2017 STRATEGIC ENERGY AND WATER ANNUAL REPORT

New York State Contract Reporter

SOUTH DAKOTA BOARD OF REGENTS. Budget and Finance ******************************************************************************

Request for Qualifications Architects CENTRAL UTILITY PLANT SHOP AND POWER CENTER

CITY OF NOVI. Police Department

Executive Order RP 49 Quarterly Energy Report for Texas A&M University September 2012

Applying Geothermal Technology for Large Scale Projects

City High Middle School pre-design recommendations. March 29, 2017

Grunenwald Science and Technology Building

Energy Reduction Strategy Through 2020

Kingsborough Community College

BOARD OF TRUSTEES OCTOBER 13, 2014

CONSTRUCTION REQUIREMENTS

Campus Energy Plant Tufts University

101 B. COMMITTEE ON GROUNDS AND BUILDINGS January 18, 2001

TEXAS A&M ENGINEERING

Lance Nichols Isaiah Patterson Nick Peterson Kyle Sala

Strip District Zoning PROPOSED UPDATES

Fifteen Year Plan for Energy Efficiency and Conservation Projects

INDOOR HEALTH ISSUES

EL CAMINO COLLEGE. Facilities Master Plan Report November 2008 PROJECTS IN DESIGN

MINUTES OF THE MEETING SDSU CENTRAL HEATING PLANT BOILER REPLACEMENT AND PLANT UPGRADES June 17, 2011

Planning for Biomed Facility Puts Energy Efficiency Under Microscope

Clemson University's Central Energy Facility and Energy Systems Laboratory An Integration of Operations and Academics

SANTA ANA COLLEGE FACILITIES COMMITTEE MEETING OCTOBER 18, 2016

Combined research & teaching labs: Engineering criteria and building system integration

Implementing Low-Cost Energy Savings Projects & Conducting Energy Audits

Existing Site Aerial Frederick High School Feasibility Study September 5, 2012

IFMA Central Pennsylvania Chapter August 20, 2014

Green Building and Operating Practices and Guidelines

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

REQUEST FOR PROPOSAL SQ # ENGINEERING / ARCHITECTURAL CONSULTING SERVICES HVAC UPGRADES CENTER BUILDINGS I, II, III & IV, L HOMMEDIEU HALL,

COOLIDGE SENIOR HIGH SCHOOL

Proposal: Mechanical System Redesign

Energy Management Report

RFQ for Consultant Services- for City of Iowa City Capitol Street Parking Ramp Façade Improvements Project 2016

SOUTH DAKOTA BOARD OF REGENTS. Budget and Finance ******************************************************************************

FACILITIES MANAGEMENT

0B MAGNOLIA HALL. Scale: 1:110. Date: Feb Time: 7:40 pm. User: brady. 10 ft

MADISON HIGH SCHOOL // Executive Summary

Northwestern University Should We Move Our Central Plant? February 22, 2017

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

Energy at Tufts Health Sciences Campus, Boston January 15, 2014

Introduction & Project Background

RENEWAL/MODERNIZATION FACILITIES REYNOLDS BUILDING #1 COLLEGE OF DESIGN

Georgetown University New Science Center

NEW MIDDLE SCHOOL PROJECT

CITY OF ROHNERT PARK CITY COUNCIL AGENDA REPORT

Sustainable Development at the University of Regina

Overlay Design Guidelines. Prairie Village Overlay Design Guidelines

Facilities Services Newsletter Summer 2012

DIRECTIVE 15H-9 Issue date: October 2018 COMMISSIONING

Exclusively For Sale. Burlington Free Press Complex College Street, Burlington, Vermont

Case Study: Golisano Institute for Sustainability

CONTENTS. 71 Section 01352, #7 (Life Cycle Cost and Life Cycle Assessment) 2/1/12 Modified entire section 72 Section 01352, #8 (Sustainability

Army Exceeds Energy Goal Ahead of Mandate (Actual Energy Reduction of 38% vs 30% and Achieved in 2010 vs 2015)

REQUEST FOR PROPOSAL. Commissioning Services College of Pharmacy Building Construct New Facility University of Iowa #

Coach House: Hunziker Hall:

GAPPA News. GAPPA 2011 Leading in Lean Time LEADING IN LEAN TIMES

CONSERVATION DISTRICT DESIGN GUIDELINES

The Waldinger Corporation Office & Production Building

Minuteman Regional Vocational Technical School

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 02/07/2013 BUILDING SURVEY DATE

SYRACUSE UNIVERSITY ENERGY CONSERVATION

Administration Building Needs Assessment

Tech Assignment 1 University Medical Center of Princeton. Plainsboro Road, Township of Plainsboro, New Jersey

Accessory Dwelling Unit Permit Submittal Requirement Checklist (Corte Madera Municipal Code Section 18.31)

Full-Scope Commissioning for High-Quality Buildings

Borough President and City Council Capital Funding Requests FY 2008

43% reduction in water use below code maximum 100% 100% 14% reduction in lighting power density. 56% of offices have thermal comfort controls 100%

DIVISION OF ADMINISTRATION UTILITIES & ENERGY SERVICES. David Payne, P.E Interim Associate Director October 16, 2012

What s My Baseline? ASHRAE

Project Delivery Evaluation

Mechanical Systems Project Proposal

Campus-Wide Cooling Plant Load Analysis & Thermal Energy Storage (TES) System Concept Engineering Study

2014 ENERGY REPORT. Mark J. Ferguson, P.E. Campus Operations & Plant Manager

Laurel School Upper Campus Building Features

Transcription:

New Research Laboratory & Given Building Renovations for The Larner College of Medicine and the Department of Psychology RFP Site Visit and Informational Meeting November 15, 2017

New Research Laboratory & Given Building Renovations AGENDA Introductions Facilities Design & Construction Website Defining the Project, Background and Goals Existing Utility Infrastructure Campus Master Plan Guidelines Regulatory Land Use Process Contract Fee Proposal Matrix Architect-Engineer Checklist of Services RFP Highlights Questions Tour of Facilities

Research: Larner College of Medicine and Psychology Department 1. The Importance of Research 2. The Problem 3. The Solution 3

The Importance of Research 1. Research is a core mission of the University of Vermont. 2. It improves the health and healthcare of citizens of VT and the World. 3. Return on investment to VT: $74-94 million annual research funding. a) Over 7 to 9 times the ROI of the other public Medical Colleges; b) Top 10 state in NIH funding per capita; c) The majority of UVM start-ups are associated with Larner College.

The Importance of Research - continued 4. Psychology most research productive of CAS; $1.6 million annual grants. 5. World-class research attracts students. a) Larner and Psychology provide student research experiences for M.D., Ph.D., undergraduate and honors college. b) Undergraduate teaching: --Psychology is the largest major at UVM. Its faculty teach nearly 12,000 credit hours per year. --Larner faculty teaching over 14,000 credit hours in AY 2018. 6. Research success disproportionally affects the rankings of Universities.

Project Goals Provide modern facilities to support the research and education missions Provide the same amount of space currently available for the College of Medicine and the Psychology Department Minimally disrupt ongoing activities during the project Provide the highest quality project at the lowest cost Deliver the project on-time and on-budget

Psychology Program Dewey Hall is 46,000 GSF and will not be part of the project Approximately 30,000 NASF of program o Approximately 6,000 NASF of wet laboratory space including several small animal holding rooms o Approximately 24,000 NASF of office, teaching laboratory, dry laboratory space and clinical space

Proposed Site Plan

Given Building Background Given Building is approximately 246,000 GSF Current uses include laboratories, a vivarium, offices, anatomy laboratory, cafeteria and a large auditorium Project will include: o A reskinning of the entire exterior o Modernization of HVAC and electrical systems of the entire building o Architectural renovations of selected areas of the building to meet the program

Given Building Final Occupancy Accommodate all College of Medicine programs currently in Given Building that are not moved to new research building, in addition to 5,000 NASF of office space from the Hill s Building o Includes approximately 28,000 NASF of wet laboratory space Accommodate the Psychology Department program of approximately 30,000 NASF

Given Building Basement

Given Building First Floor

Given Building Second Floor

Given Building Third Floor

Given Building Fourth Floor

Critical Project Experience Design of new state-of-the-art Research Buildings Design of a rejuvenation of an aged research building to meet modern standards, while occupied

Overview of Utilities Infrastructure and Existing Conditions November 15, 2017 By Salvatore Chiarelli, Director Physical Plant Department

Existing Central Heating and Cooling Plant Four (4) 40,000 pound per hour steam boilers One (1) 64,000 pound per hour steam boiler Steam feeds about 90% of campus square footage Three (3) Chillers in Central Plant - Two 1350-ton steam turbines and One 1500-ton electric - Chilled water feeds only 30% of campus Annual plant shut down occurs after graduation (May) Interruptible natural gas service, Vermont Gas System #2 as back up fuel, 150k gallons stored underground on site Very efficient system, 90% condensate return

N Proposed Site

N Existing Utilities

N

Existing College of Medicine (COM) Plant and Utilities (2) 20,000 pound per hour steam boilers at Given Can only run 1 absorption machine because of pipe size limitation Given steam boilers supply in island mode if needed (2) 1000 ton absorption chillers in HSRF (1999) Serve Given, Rowell and HSRF when needed One small electric chiller serves Animal Quarters only Need additional chilled water supply to meet growing needs Given electric load about 1MW Electric: Burlington Electric Water/sewer: Burlington Public Works

Opportunities Desirable to run a larger pipe to run both absorption machines from Given to HSRF Heating and Cooling recovery Will need additional chilled water supply to meet growing needs Central plant was designed with space for another chiller Potential to send chilled water out to campus from HSRF Potential to run a chilled water line to west side HSRF from Central Plant

Given Building Existing Conditions & Challenges

Building Envelope Pre-Cast Siding Clips are failing, rusting Siding not insulated Windows Single-pane, not energy efficient Evidence of leaks Asbestos caulking

Roofing Roof membrane replaced in 2000 Hundreds of penetrations and anchors in existing roof Seals failing and leaks result Courtyard Glass Roof Panels are cracking Safety risks of performing work

Mechanical HVAC A 2-pipe system is used for heating (hot water) and cooling (chilled water) Severe aging and deterioration of original steel piping throughout system Pipe locations are difficult to access behind cinderblock, sheetrock, above ceiling ductwork and electrical conduit. Valves Hundreds of original valves throughout system for heating, cooling, potable water, steam, RO water, vacuum and compressed air. Many valves not fully operational.

Air Handling Units All are original equipment showing severe aging 100% outside air Excessive wear of components causes vibrations throughout facility. To compensate, systems are run at slower, less optimum speeds. Condensate pans deteriorating

Vacuum System One central vacuum system only serves parts of the building. Water-cooled unit, not energy efficient. When the central vacuum system fails, PPD has no plans to replace it. New laboratories are required to install individual vacuum pump systems.

Electrical Major switchgear upgrade completed in 2010. Building distribution is aged. Old wiring throughout building Building Automation Controls Building is served by both Honeywell and Johnson Controls systems which report to central command system. Actuators and valves are operated by both modern DDC electronics and some obsolete air lines.

Elevators Some upgrades, but all are original 3 elevators serve Given Cold Rooms All original equipment Asbestos containing materials used during construction Some compressor units have been replaced with newer type of Freon

Strobe Fans Two major fans serve all the laboratory fume hoods. Fans are not interconnected; neither one has capacity to service entire facility No redundancy or backup fan is in place, other than a spare motor stored in penthouse.

New Research Laboratory & Given Building Renovation Campus Master Plan Guidelines & Regulatory Land Use Process Linda Seavey Director Campus Planning Services Campus Master Plan: www.uvm.edu/~plan Site Planning & Design Review Process: www.uvm.edu/~plan/cmpc_design _review_process.pdf

2006 Campus Master Plan Board of Trustees Approved Divides campus into 9 Architectural Districts (project is in Gateway District) Land Banks provide approved development sites, with priority for already developed areas (parking lots) Given Building New Research Lab Site Guiding Principles Sense of Place Inclusive & Accessible Environmental Sustainability Circulation Compatibility Flexibility Campus Master Plan Committee internal review process Land Banks map excerpted from the 2006 Campus Master Plan

Gateway District Modern expression of the campus First part of campus that most visitors will encounter International Style buildings Jeffords Building Site is on land bank within Gateway District Infill development strengthens the campus image and fabric of the district Health Science Research Facility

Gateway District Foreground Buildings New Research Laboratory will be seen as a foreground building New building massing should physically relate to both old and new structures The Campus Master Plan goal for the Gateway District: o Express the importance of scientific research to the University, with an emphasis on high-tech building design University of Michigan Biomedical Science Research Building o o Include large areas of glass for public spaces Appropriate building materials: stone, metal, wood, and precast, in addition to red brick Recognize University ethic of sustainability Harvard University Science Building

Gateway District Landscape Guidelines Landscape improvements in the northern end of the District are conceived as being urban in character Proposed quadrangles in the vicinity of the Given Building are more structured and geometric than on much of the rest of the campus

Campus & Community Context New Research Lab Site UVM Medical Center Given HSRF Stafford Jeffords

City of Burlington Zoning Central Campus Institutional Core Campus Overlay Zoning District: Institutional (I) & Institutional Core Campus Overlay (ICC): Lot Coverage: Allows up to 70% lot coverage Height: Allows up to 10 stories/140 feet in height overlay Capacity (stormwater, transportation, & utilities) Circulation Traffic Analysis Parking requirements met by UVM Institutional Adjacencies & Compatibility Compliance with UVM Campus Master Plan, local municipal & regional plans 1 st option for siting a project is on pre-developed land such as parking lots, or existing building footprints

Stormwater Planning

Given Building Historic Preservation Opened in 1963 Largest deferred maintenance cost at UVM and is the least energy efficient building on campus Single biggest rehab project at UVM Exterior changes require VT Division for Historic Preservation review 2011 UVM negotiated changes to one façade, with efforts to be made to preserve other three façades to the extent possible Conformance with this agreement will expedite permit process

Regulatory Process/Timeline New Research Laboratory Building Regulatory Process Estimated # Meetings # Hours/ Time of Day Estimated Cumulative Hours Given Building Renovation Regulatory Process Estimated # Meetings # Hours/ Time of Day Estimated Cumulative Hours UVM Permit Strategy Meetings 5-7 2 Day 10-14 UVM Permit Strategy Meetings 5-7 2 Day 10-14 Campus Master Plan Review 1 2 Day 2 Campus Master Plan Review 1 2 Day 2 Burlington Neighborhood Planning Assemblies 2 2 Evening 4 Vermont Division for Historic Preservation Review 2-4 2 Day 4-8 Vermont Division for Historic Preservation Review (Limited) 2-3 2 Day 4-6 Burlington Development Review Board 1-2 2 3 evening 3-6 *Burlington Technical Review 1 2 Day 2 Act 250 Pre-Hearing or Site Visit 1 2-3 Day 3 *Burlington Design Advisory Board 1 2 Afternoon 2 Act 250 Hearing 1 2-3 Evening 3 *Burlington Conservation Board 1 2 Afternoon 2 Estimated Total 11-16 25-36 Burlington Development Review Board 1 2 Act 250 Pre-Hearing or Site Visit 2 Act 250 Hearing 1 2-3 Evening 2-3 Day 2-3 Evening 3-6 4-6 3 NOTE: According to 24 V.S.A. 4413, the City of Burlington may only regulate with respect to location, size, height, building bulk, yards, courts, setbacks, density of buildings, off-street parking, loading facilities, traffic, noise, lighting, landscaping, and screening requirements. Estimated Total 17-21 36 47 * These meetings are more likely to happen if the project is deemed by the Burlington Planning and Zoning Department as Major Impact. While this project meets the size criteria for Major Impact, there is an exemption for projects that have no change of use or increased parking demand. City staff will make that determination.

Campus Master Plan: www.uvm.edu/~plan

Contract Architect-Engineer Checklist of Services Fee Proposal Matrix New Research Laboratory & Given Building Renovation for The Larner College of Medicine and The Department of Psychology New Research Facility Given Renovation Project Phase Schematic Design: Architectural Landscape Civil Structural MEP Fire Protection LEED Cost Estimating A/E Checklist of Services Fee Reimbursable Expenses Fee Reimbursable Expenses Schematic Design Total $0.00 $0.00 $0.00 $0.00

RFP Highlights Full design team requirement, with Vermont partnership of 20% effort minimum Full design and construction schedule RFP schedule Method of Construction, Pre-construction services, Estimates Proposal Requirements, Selection Criteria, Proposal Terms, and Deadlines

New Research Laboratory and Given Building Renovation Design & Construction Schedule January 15, 2018 May 1, 2018 May 18, 2018 February 1, 2019 February 1, 2019 April 1, 2019 June 1, 2019 December 1, 2020 January 1, 2021 December 1, 2023 Begin Schematic Design Phase Complete Schematic Design and estimate reconciliation Present Schematic Design to Board of Trustees Complete Design Development, Construction Drawings and estimate reconciliations Present Construction Drawings to Board of Trustees Completion of Bid Phase Begin Construction on New Research Laboratory Complete Construction on New Research Laboratory Begin Renovation of Given Building Complete Renovation of Given Building

RFP Schedule Tuesday, October 31, 2017 Wednesday, November 15, 2017 (1:30 PM) Tuesday, November 28, 2017 (2:00 PM) Tuesday, December 5, 2017 Thursday, December 14, 2017 (2:00 PM) Week of January 2-4, 2018 Monday, January 15, 2018 Request For Proposal Available Mandatory Campus Site Visit Deadline For Questions Addendum to be Issued Request for Proposals Due On-Campus Interviews with Short Listed Firms Schematic Design Start Date