SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS

Similar documents
Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Seismic analysis of a RC frame building with FRP-retrofitted infill walls

GFRP retrofitted RC frames with columns subjected to high axial stresses

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

SEISMIC RETROFIT OF BEAM-COLUMN JOINTS WITH FRP SHEETS

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

Confining Concrete Columns with FRP Materials

Invention: Seismic Retrofitting by Exterior Steel Brace Structural Building Jacketing System

Seismic Design Principles for RC Structures

Fragility Curves for Seismically Retrofitted Concrete Bridges

Fragility Curves for Seismically Retrofitted Concrete Bridges

SEISMIC REHABILITATION OF REINFORCED CONCRETE BRIDGE COLUMNS IN MODERATE EARTHQUAKE REGIONS USING FRP COMPOSITES

SeismoBuild Verification Report (TBDY) For version 2018

Finite Element Simulation of Low Concrete Strength Beam-Column Joint Strengthened with CFRP

Seismic Performance of Residential Buildings with Staggered Walls

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

SEISMIC VULNERABILITY OF EXISTING RC BUILDINGS IN INDIA

NONLINEAR TIME HISTORY ANALYSIS OF RC FRAME RETROFITTED WITH BUCKLING RESTRAINED BRACES 1

EFFECT OF INFILL WALLS ON SOFT STORY BEHAVIOR IN MID-RISE RC BUILDINGS

Comparisons to Tests on Reinforced Concrete Members

Basic quantities of earthquake engineering. Strength Stiffness - Ductility

Modeling aspects concerning the axial behavior of RC columns

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

406 A.R. Khaloo and A. Esmaili This method does not enhance column moment capacity and stiness signicantly. Therefore, additional earthquake forces in

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

Seismic Behavior of Low Strength RC Columns with Corroded Plain Reinforcing Bars

ALTERNATIVE SEISMIC RETROFIT SOLUTIONS FOR A NON-DUCTILE R/C STRUCTURE

Effect of Axial load on deformation capacity of RC column

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

Seismic Evaluation and Strengthening of RC Frames with FRP Composites

Evaluation of Seismic Behaviour of Old Reinforced Concrete Structures Based on Ductility Limit

EFFECT OF USER DEFINED PLASTIC HINGES ON NONLINEAR MODELLING OF REINFORCED CONCRETE FRAME FOR SEISMIC ANALYSIS

A Comparison of Basic Pushover Methods

AN ALTERNATIVE PROCEDURE FOR THE PERFORMANCE ASSESSMENT OF FRP-RETROFITTED RC BUILDINGS USING LUMPED PLASTICITY

SeismoBuild Verification Report (ASCE 41-17) For version 2018

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 1, 2011

SEISMIC RETROFIT OF NON-DUCTILE RECTANGULAR REINFORCED CONCRETE COLUMNS BY CFRP JACKETING

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

FRP-Confinement of Hollow Concrete Cylinders and Prisms

AXIAL TESTING OF CONCRETE COLUMNS CONFINED WITH CARBON FRP: EFFECT OF FIBER ORIENTATION. Abstract

EXPERIMENTAL INVESTIGATION OF DAMAGED EXTERIOR RC BEAM COLUMN JOINTS RETROFITTRD BY FRP JACKETING

EVALUATION OF RESPONSE REDUCTION FACTOR OF RC FRAMED BUILDINGS BY PUSHOVER ANALYSIS

Seismic upgrade of a reinforced concrete building

Effect of Material Strength and Reinforcement Detailing on Displacement Capacity of Existing RC Buildings

optimal design of frp retrofitting for seismic resistant rc frames C. Chisari 1, C. Bedon 2 1

Influence of Longitudinal FRP Straps on the Behaviour of Circularised and FRP Wrapped Square Hollow RC Concrete Specimens

Enhancing the Compressive Strength of Square Cross Sectional Column Using FRP Material

VERIFICATION OF A REINFORCED CONCRETE COLUMN COMPUTER MODEL UNDER UNIAXIAL AND BIAXIAL BENDING LOADING CONDITIONS

Exploring the Implication of Multi-plastic Hinge Design Concept of Structural Walls in Dual Systems

RESEARCH ON SEISMIC RETROFIT OF EARTHQUAKE-DAMAGED AND SEISMIC-DEFICIENT STRUCTURES USING FIBRE-REINFORCED POLYMER (FRP) TECHNOLOGY

Modelling of RC moment resisting frames with precast-prestressed flooring system

STEEL JACKETING FOR IMPROVEMENT OF COLUMN STRENGTH AND DUCTILITY

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October ISSN Pushover Analysis of RC Building

SEISMIC PERFORMANCE OF BRIDGE COLUMNS WITH DOUBLE INTERLOCKING SPIRALS

Innovative Retrofit of Concrete and Masonry Buildings

Experimental tests on RC hollow columns strengthened with FRPs

Evaluation of the main parameters affecting seismic performance of the RC buildings

EXPERIMENTAL STUDY OF THE EFFECT OF REINFORCEMENT STABILITY ON THE CAPACITY OF REINFORCED CONCRETE COLUMNS

Test of Rectangular Confined Concrete Columns for Strength and Ductility

Inelastic Versus Elastic Displacement-Based Intensity Measures for Seismic Analysis

EXPERIMENTAL STUDY ON THE SEISMIC PERFORMANCE OF EXTERNALLY CONFINED REINFORCED CONCRETE COLUMNS

Seismic Behavior of Concrete Columns Confined with Steel and Fiber-Reinforced Polymers

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

UPGRADING SHEAR-STRENGTHENED RC BEAMS IN FATIGUE USING EXTERNALLY-BONDED CFRP

Upgrading ductility of RC beam-column connection with high performance FRP laminates

Investigation on Behaviour of Reinforced Concrete Beam Column Joints Retrofitted with FRP Wrapping

XTRACT: A Tool for Axial Force - Ultimate Curvature Interactions. C.B. Chadwell 1 and R.A. Imbsen 2

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

Seismic Behavior of Shear-Critical Reinforced Concrete Frame: Experimental Investigation

AFRP retrofitting of RC structures in Japan

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

Strengthening Concrete Sections by FRP Materials

Improving the Seismic Response of a Reinforced Concrete Building Using Buckling Restrained Braces

Nonlinear Static Pushover Analysis of a Shear Wall Building in Madinah

beni-suef university journal of basic and applied sciences 5 (2016) Available online at ScienceDirect

Seismic Behaviour of RC Shear Walls

International Journal of Intellectual Advancements and Research in Engineering Computations

Performance Based Seismic Design of Reinforced Concrete Building

Seismic Assessment of Non-Seismically Designed Reinforced Concrete Frames with Core Walls

PUSHOVER ANALYSIS FOR PERFORMANCE BASED-SEISMIC DESIGN OF RC FRAMES WITH SHEAR WALLS

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

EFFECT OF CAP BEAM TO COLUMN INERTIA RATIO ON TRANSVERSE SEISMIC RESPONSE OF MULTI COLUMN BRIDGE BENTS

SEISMIC RETROFITTING OF RECTANGULAR BRIDGE PIERS WITH FRC JACKETS

EFFECTS OF SOFT FIRST STORY ON SEISMIC PERFORMANCE OF RC BUILDINGS AND SUSTAINABLE APPROACH TO RETROFIT

TESTS ON AN INTERIOR REINFORCED CONCRETE BEAM-COLUMN JOINT. R. Park*, L. Gaerty**, and E.C. Stevenson***

DISPLACEMENT-BASED SEISMIC ASSESSMENT AND REHABILITATION OF EXISTING NON-DUCTILE REINFORCED CONCRETE STRUCTURES

Performance-Based Seismic Evaluation of Wind-Impacted Tall Buildings

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET

Seismic Detailing of RC Structures (IS: )

Analysis of the confinement of RC hollow columns wrapped with FRP

Design of FRP confinement for square concrete columns

Analysis, Design, and Construction of SMA-Reinforced FRP- Confined Concrete Columns

SEISMIC EVALUATION AND RETROFIT OF A HOSPITAL BUILDING USING NONLINEAR STATIC PROCEDURE IN ACCORDANCE WITH ASCE/SEI 41-06

Strengthening of RCC Column Using Glass Fibre Reinforced Polymer (GFRP)

CYCLIC BEHAVIOR OF SLENDER R/C COLUMNS WITH INSUFFICIENT LAP SPLICE LENGTH

Evaluation of Response Reduction Factor and Ductility Factor of RC Braced Frame

SHAKING TABLE TEST OF LARGE SCALE NONDUCTILE RC FRAMES RETROFITTED WITH FRP COMPOSITES

Investigation of FRP Strengthening Design Rules for Insufficient RC Columns 1

A Study on Hybrid FRP Wrapped Axially Loaded RC Capsule Column

DETERMINING A METHOD OF DYNAMIC ANALYSIS FOR THE VIADUCTS WITH GEOMETRIC IRREGULARITY AND INVESTIGATION OF THE SEISMIC PERFORMANCE OF NURTEPE VIADUCT

Transcription:

6 th International Conference on Advanced Composite Materials in Bridges and Structures 6 ième Conférence Internationale sur les matériaux composites d avant-garde pour ponts et charpentes Kingston, Ontario, Canada, 5 May 1 / -5 mai 1 SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUS M. Comert and A. Ilki Civil Engineering Faculty, Istanbul Technical University Ayazaga Campus 34469 Istanbul, Turkey mcomert@itu.edu.tr ailki@itu.edu.tr ABSTRACT: A typical three-storey reinforced concrete building representing a school building is analysed in terms of seismic safety. The structural system of this typical building includes extended rectangular columns with cross-sectional aspect ratio of 3 (5 x 75 mm x mm) and demonstrates typical deficiencies of the time of its construction in Turkey, particularly in terms of low quality workmanship, resulting with low quality concrete and improper reinforcement detailing. A vital deficiency about the reinforcement detailing is the large spacing of transverse reinforcement. The nonlinear analyses of this typical building showed that seismic retrofitting is necessary for the structural system to achieve the required seismic performance level for a school building, which is densely occupied by students. For seismic retrofitting, among several other techniques, jacketing of columns with FRP (fiber reinforced polymer) sheets is considered as one of the feasible approaches, for enhancing the seismic performance of the structure to the required level through ductility improvement. After retrofitting, the nonlinear pushover analysis is performed once more for the assessment of seismic safety. In addition, the comparison of the results for original and retrofitted structure is presented. This comparison clearly demonstrated that the efficiency of the FRP jacketing of extended rectangular columns reduce the structural damage level. 1. INTRODUCTION Earthquakes are major threats for countries, such as Turkey, located in earthquake prone areas. To mitigate the potential losses of earthquakes, a large number of existing buildings in these areas need to be strengthened. The typical deficiency encountered in these buildings is the low quality workmanship, resulting with low quality concrete and improper reinforcement detailing. In this study, a typical existing three-storey reinforced concrete building representing a school building is analysed in terms of seismic safety. The building has the characteristics of typical buildings designed and constructed in 197s. While the building is regular in plan and elevation, its structural system demonstrates typical deficiencies of the time of its construction in Turkey, particularly in terms of low quality concrete and improper reinforcement detailing. A vital deficiency about the reinforcement detailing is the large spacing of transverse reinforcement and inadequate hook details of stirrups. The nonlinear structural analyses of this typical building showed that seismic retrofitting is necessary for the structural system to achieve the required seismic performance level for a school building. Jacketing of columns with FRP (fiber reinforced polymer) sheets is considered as one of the feasible approaches, for enhancing the seismic performance of the structure to the required level through ductility improvement. The structural system of the building includes extended rectangular columns with dimensions of 5x75 (mm x mm). The study compares the deformability performance of the extended rectangular columns and overall structural seismic performance of the building before and after FRP jacketing of columns. During the nonlinear analysis of the retrofitted structure, the results of tests carried out at Istanbul Technical University on the columns with 1

cross-sectional aspect ratios of and 3 (Ilki et al. 4) are utilized for determination of the behavior of extended rectangular columns jacketed with FRP sheets.. OUTLINE OF THE STRUCTURE The building, which demonstrates the typical deficiencies in terms of reinforcement detailing and low quality concrete, has three stories and it is regular in plan (Figure 1a) and elevation. The column dimensions are 5 x 75 (mm x mm) and 6 x 6 (mm x mm), the shear wall dimensions are 5 x (mm x mm), and the beam dimensions are 5 x 6 (mm x mm). The reinforcement details of columns, shear walls and beams are presented in Figure 1b. The transverse reinforcement (stirrups) of the columns and beams are 8 mm diameter bars with mm spacing with no intermediate cross-ties. The strength of concrete is assumed to be 15 MPa and the yield strength of the steel (plain round bars) is considered to be MPa. In the analysis, the concrete is modelled through the stress-strain relationship proposed by Mander et al. (1988) and the behaviour of steel is defined through on elasto-plastic steel model with strain hardening. The stress strain curves of concrete and steel are presented in Figure. 16ɸ16 3ɸ18 C4 C8 C1 C16 ɸ18 75 mm 6 mm C3 C7 C11 C15 5 mm 3ɸ18 4ɸ16 5 mm C1, C, C3, C4, C13, C14, C15, C16 Stirrups ɸ8/ ɸ1/3 6 mm C6, C7, C1, C11 4ɸ16 C C6 C1 C14 ɸ8/ mm C5, C8, C9, C1 Lateral Reinf. ɸ1/3 y Interior support sections Exterior support sections C1 C5 C9 x C13 15 mm 3ɸ16 5ɸ16 Beam stirrups ɸ8/ 6 mm 4ɸ16 3ɸ16 5 mm 5 mm (a) (b) Fig 1 - (a) Plan of the building (for all stories) (b) column, shear wall and beam section details Fig - (a) Concrete (b) steel material stress-strain curves

3. ANALYSIS OF STRUCTURE 3.1 Nonlinear Modelling and Analysis The single mode pushover analyses are performed in weak (x) and strong (y) directions of the building. During the analyses, Perform 3D (Computers and Structures Inc, 6) nonlinear analysis software is used. The material nonlinearity is considered through the plastic hinge concept. Zero length plastic hinges representing the nonlinear behaviour are assigned to the two ends of the structural members. It should be noted that while converting nonlinear curvatures to rotations the plastic hinge length is assumed to be 5% of the section depth as suggested by Turkish Seismic Design Code (Ministry of Public Works and Settlement Government of Republic of Turkey, TSDC, 7). For determination of characteristics of these plastic hinges, flexural section analyses are carried out for column, shear wall and beam sections given in Figure 1 considering material models presented in Figure. The building is located on ground type of Z3 with characteristic periods of.15 and.6 in the highest seismic risk zone. In Figure 3, the elastic design acceleration spectrum for school buildings defined for Z3 type ground in highest seismic risk zone according to TSDC is presented. The design earthquake has % exceedance probability in 5 years. 1.5 S ae (g) 1.5..6 1. 1.8.4 3. Period (sec) Fig 3 The design acceleration spectrum for school buildings. While determining structural seismic performance levels, TSDC describes three different damage limits for reinforced concrete sections in terms of plastic strains of concrete and steel. The details of these limits are presented in Table 1. In accordance with these strain limits, four different damage ranges are defined for reinforced concrete members (Figure 4). As it can be seen in Figure 4, damage level between zero and minimum damage limit is slight damage, between minimum damage limit and safety limit is moderate damage, between safety limit and failure limit is heavy damage and after failure limit is collapse. Table 1 Section damage limits according to TSDC (Ministry of Public Works and Settlement Government of Republic of Turkey, 7). Damage levels Concrete strain limit* Steel strain limit Minimum damage limit () c.1 s.35 Safety limit ().35.1( s ).85.135.4 cg sm Failure limit ().4.14( s ).11.18.6 cg sm *In equations, s is volumetric ratio of transverse reinforcement and sm is the required volumetric ratio of transverse reinforcement according to TSDC. In addition, c is the maximum compression strain of unconfined concrete, cg is the maximum compression strain of confined concrete and s is the maximum steel strain. s s 3

Internal Force Slight Damage Moderate Damage Heavy Damage Collapse Deformability Fig 4 Damage levels of the reinforced concrete members according to TSDC (Ministry of Public Works and Settlement Government of Republic of Turkey, 7). The overall structural performance of the building is decided by the percentage of structural members in different damage levels. In this stage, TSDC defines four different structural performance ranges including immediate occupancy (IO), life safety (LS), collapse prevention (CP) and collapse or partial collapse (C). The expected seismic performance level for a school building under defined earthquake spectrum given in Figure 3 is life safety (LS). For LS performance level, the structure should satisfy the following requirements; i) all member should have sufficient shear strength, ii) the contribution of heavily damaged vertical structural members to shear load carrying should be less than % in each floor, iii) the damage of non of the damage structural members should fall in the range of collapse and iv) the contribution of the structural members whose both ends (critical sections) exceed slight damage level to the shear load carrying capacity should be lower than 3% in each floor. 3. Results The base shear-top displacement curves of the structure in weak (x) and strong (y) directions are given in Figure 5. To evaluate reinforced concrete member performances, the axial load-total curvature interaction curves are used. These curves are obtained for each level of section strain limits. The axial load-total curvature interaction curves for the first storey columns and shear wall in weak and strong directions are presented in Figures 6 and 7, respectively. The damages of other structural members are not shown since the results obtained for the first storey members are sufficient to determine the structural performance. In this building, there is no shear failure in structural members. As can be seen from Figures 6 and 7, almost all extended rectangular columns (C1, C, C3, C4, C13, C14, C15 and C16) exceeded the failure strain limits. According to TSDC, if strains of a vertical structural member of the building exceed the failure strain limits, the overall structural earthquake performance is determined as collapse performance level. Therefore, the performance of this school building falls in the category of collapse and measures are necessary to upgrade the seismic performance level to life safety. Shear (V, kn) 15 1 5 Shear (V, kn) 15 1 5..5.1.15. Top Displacement, u N1 (m)..5.1.15. Top Displacement, u N1 (m) (a) (b) Fig 5 The base shear-top displacement curves in (a) weak (b) strong direction of the structure. 4

375 3 5 15 75 -.15 -.1 -.5.5.1.15-75 1 8 6 4 -.4 -...4-75 6 45 3 15 -.15 -.1 -.5.5.1.15-15 (a) (b) (c) Fig 6 The damages of the first storey (a) 5 x 75 columns (b) x 5 shear walls (c) 6 x6 columns in weak direction (dimensions in mm). 375 3 5 15 75 -.4 -...4-75 1 8 6 4 -.4 -...4-75 6 45 3 15 -.15 -.1 -.5.5.1.15-15 (a) (b) (c) Fig 7 The damages of the first storey (a) 5 x 75 columns (b) x 5 shear walls (c) 6 x6 columns in strong direction (dimensions in mm). 4. RETROFITTING PROCEDURE 4.1 Model for FRP Confined Extended Rectangular Since the compressive strains of the extended rectangular columns (5 x 75 mm x mm) exceeded the failure strain limits, the overall structural performance is assessed as collapse. TSDC does not permit FRP jacketing of columns with cross-sectional aspect ratio greater than. In contrast to the limitation of TSDC, for research purpose, to enhance the seismic performance of the structure, the extended rectangular columns are jacketed with FRP sheets in transverse direction considering the experimental and theoretical studies conducted at Istanbul Technical University before (Ilki et al, 4). In the referenced study, totally 46 specimens with unconfined concrete strengths between 6 1 MPa were axially tested after wrapping different amount of carbon fiber reinforced polymer (CFRP) sheets around the columns in transverse direction. The cross-sectional dimensions of the tested specimens with cross-sectional aspect ratio of 1:3 were 15 x 45 (mm x mm). The obtained test results for the specimens with cross-sectional aspect ratios of 1:3 are presented in Table. In this table, f co and co are the unconfined concrete strength and corresponding axial strain, f cc and cc are the confined concrete strength and ultimate axial strain and r is the corner radius. The specimen names are assigned considering the shape and depth/width ratio of the cross-section, number of transverse CFRP plies and the corner radius. As an example, R-3-3-4a represents the first specimen with rectangular cross-section of aspect ratio 1:3, which is wrapped by 3 plies of transverse CFRP sheets. The corner radius of this specimen is 4 mm. It should be noted that in this test CFRP sheets with elasticity modulus of 3 MPa, effective thickness of.165 mm, tensile strength of 343 MPa and ultimate elongation capacity of.15 were used. As a result of the experimental studiy, an analytical confinement model for concrete members jacketed with CFRP sheets was proposed by Ilki et al. (4). The analytical model is summarised by Equations 1-7. In these equations, f lmax is the maximum effective transverse confinement stress, a is the efficiency factor that is to be determined based on the section geometry as the ratio of effectively confined cross-sectional area to the gross crosssectional area, f is the ratio of wrapping material to the concrete cross-section, h,rup is the rupture strain of the frp ( h,rup =.7 frp ), is the ratio of cross-sectional area of the longitudinal reinforcement to the crosssectional area of wrapped member, is the arching angle(which is assumed as 45 ), t f and n f are the 5

effective thickness and the number of plies of wrapping material, and b and h are the width and depth of the rectangular member to be wrapped. 4. Design of FRP Retrofit for Extended Rectangular As seen in Fig. 6, if the curvatures corresponding to damage limits can be increased for extended rectangular columns, the damages of these columns can be reduced and consequently the overall structural performance level can be enhanced. Consequently, the extended rectangular columns are decided to be wrapped with three plies of carbon FRP sheets. The characteristics of the carbon fibers used in the retrofit design are given in Table 3. During design of FRP retrofit, it is assumed that the corners are to be rounded to a radius of 4 mm and the non-structural partition walls were partly demolished from two sides of the columns during the retrofitting works, The confined concrete compressive strength and ultimate axial strain are determined by the use of equations proposed by Ilki et al. (4). During flexural sectional analysis, which is carried out using fiber analysis approach, a bilinear confined concrete stress-strain model and an elasto-plastic steel stress-strain model with strain strain hardening are used. It should be noted that no additional safety coefficients are taken into account while using Equations 1-7 other than those, which are inherently considered by these equations (such as h,rup =.7 frp ). Since the Equations 1-7, are behavior oriented equations, in case of actual retrofit design, additional safety factors should be considered. Consequently, the efficiency of FRP retrofit will be slightly reduced due to additional safety coefficients, which should be used for converting behaviour oriented equations to design equations. Table Experimental results for specimens with 1:3 aspect ratio (Ilki et al., 4). Specimen f co r f cc (MPa) Plies (mm) (MPa) co cc f cc / fco cc / co R-3--4 9.8 4 -.4 - - - R-3-1- 9.8 1 4 1..4.4 1.4 1. R-3-1- 4a 9.8 1 4 1..4.31 1. 1.9 R-3-3- 4b 9.8 3 4 15.1.4.7 1.54 3. R-3-3- 4a 9.8 3 4 16.6.4.61 1.69 5.4 R-3-5- 4b 9.8 5 4.1.4.98.5 4.83 R-3-5- 4a 4b 9.8 5 4 17.1.4.99 1.74 41.5 1. f lmax f cc fco 1.4 (1) fco f lmax a ρf ε h,rupe frp () A A ρ (3) a 1 1 A 1 (b r) (h r) tanθ (4) 3bh A 4r πr (5) bh nf t f b h ρf (6) bh 6

.5 h h f ε ε 1 1 l max (7) cc co b b f co Table 3 Characteristics of the carbon FRP sheets. Tensile Strength (MPa) Elasticity Modulus (MPa) Ultimate elongation Effective thickness (mm) 49 3.1.166 5. ANALYSIS RESULTS OF RETROFITTTED STRUCTURE Nonlinear pushover analysis is carried out once more for the seismic safety assessment of retrofitted structure. The comparison of the moment-curvature relationships in strong and weak axes for C column (which have dimensions of 5 x 75 mm x mm) before and after retrofitting is presented in Figure 8, and the base shear-top displacement curves of the retrofitted structure with comparison of original structure in weak and strong directions are given in Figure 9. The damages of the first storey reinforced concrete members in weak and strong directions are also shown in Figures 1 and 11, respectively. According to the obtained results, no structural member fail in shear and strains of no member exceed the failure strain limits. The damage levels of extended rectangular columns are reduced from heavy damage or collapse level to moderate damage. On the other hand, the maximum contribution of the heavily damaged members to shear load carrying is approximately 3% in each direction and the maximum contribution of the members that both ends exceed slight damage level to the shear load carrying capacity is lower than 3% in each floor. The heavy damaged columns (which have dimensions of 6 x 6 mm x mm) are not retrofitted. It is clear that the damages of these columns could be reduced through CFRP jacketing as well. This study intends to investigate the seismic safety of the structure. Other risks, such as fire may also affect the retrofitting material components (especially epoxy resin). Although, in this study, it is assumed that the structure is safe under gravity loads and the retrofitting does not contribute to the structural system against gravity forces, it clear that taking precautions such as using of coating materials for other risks may be necessary for actual applications. Moment (knm) 45 3 15 After retrofitting Before retrofitting.5.1.15..5.3 Curvature (1/m) Moment (knm) 15 1 5 After retrofitting Before retrofitting.15.3.45.6.75.9 Curvature (1/m) (a) (b) Fig 8 Comparison of the moment curvature relationships around (a) strong and (b) weak axes for the extended rectangular columns. Retrofitted structure Retrofitted structure Shear (V, kn) 15 1 5 Original structure Shear (V, kn) 15 1 5 Original structure..15.3.45.6.75.9 Top Displacement, un1 (m)..15.3.45.6.75.9 Top Displacement, un1 (m) (a) (b) Fig 9 The first shear-peak displacement curves in (a) weak (b) strong direction of the original and retrofitted structure. 7

45 3 15 -.15 -.1 -.5.5.1.15-15 1 8 6 4 -.4 -...4-75 6 45 3 15 -.15 -.1 -.5.5.1.15-15 (a) (b) (c) Fig 1 The damages of the first storey (a) 5 x 75 columns (b) x 5 shear walls (c) 6 x 6 columns in weak direction (dimensions in mm). 375 3 5 15 75 -.6 -.4 -. -75..4.6-15 1 8 6 4 -.4 -...4-75 6 45 3 15 -.15 -.1 -.5.5.1.15-15 (a) (b) (c) Fig 11 The damages of the first storey (a) 5 x 75 columns (b) x 5 shear walls (c) 6 x6 columns in strong direction (dimensions in mm). 6. CONCLUSIONS The efficiency of the external confinement with FRP sheets for extended rectangular columns for enhanced deformability was shown by the authors in a previous study carried out in Istanbul Technical University. In this study, a typical three-storey building is analysed with and without retrofitting through nonlinear pushover analysis. The following findings are derived from the analyses; i) the original structure with improper reinforcement details and low quality of concrete did not satisfy the seismic performance requirements according to TSDC, ii) retrofitting of the extended rectangular columns (5 x 75 mm x mm) by CFRP sheets enhanced the deformability capacity of the columns significantly and leading a remarkably better overall seismic performance. 7. REFERENCES Computer and Structures Inc. (CSI)., 6. Perform 3D Nonlinear Analysis and Performance Assessment for 3D Structures User Guide. Berkeley, California, USA. Ilki A., Kumbasar N. and Koc V., 4. Low Strength Concrete Members Externally Confined with FRP Sheets. Structural Engineering and Mechanics, Vol.18, pp.1-8. Mander, J.B., Priestley, M.J.N., Park, R. 1988. Theoretical Stress-Strain Model For Confined Concrete. Journal of Structural Division (ASCE), Vol. 114, pp. 184-186. Ministry of Public Works and Settlement Government of Republic of Turkey, 7. Turkish Seismic Design Code. Ankara, Turkey. 8