Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES

Similar documents
A4/8 PS AW2002 Issue 6 Sept Permishield

A4/8 PS AW2324D Issue 10 May Permishield

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

Double Brick Cavity Walls

Permifloor. Insulation WATER-PERMEABLE UNDERFLOOR INSULATION

Insulbreak. Insulation. thermal break solution

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

Permifloor. Insulation WATER-PERMEABLE UNDERFLOOR INSULATION

Permifloor. Insulation WATER-PERMEABLE UNDERFLOOR INSULATION

A4/6 PS AW1551 Issue 4 Nov Permishield

Insuliner. Insulation REFLECTIVE INSULATION FOR USE WHERE

Insulbreak. Insulation. thermal break solution

Brick Veneer Walls. Insulation

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

K8 Cavity Board. Insulation CAVITY WALL INSULATION

K12 Framing Board. Insulation

K17 Insulated Plasterboard

K17 Insulated Plasterboard

Soffit Board. Insulation

K18 Insulated Plasterboard

K3 Floorboard. Insulation INSULATION FOR FLOORS

K5 External Wall Board

K3 Floorboard. Insulation INSULATION FOR FLOORS

K17 Insulated Plasterboard

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS

Fire Safety Compliance Guide: Wall and Ceiling Linings

K5 External Wall Board

Timber-framed Walls. Insulation

Sarking & Insulation Products A Blue Chip Company

Product Catalogue

K10 FM Soffit Board. Insulation

Fire Safety Compliance Guide: Wall and Ceiling Linings

Concrete Soffit Direct Fix

The great Aussie shed deserves great Australian insulation

TR26 LPC/FM / TR27 LPC/FM

Don t leave money on the floor.

TR26 LPC/FM / TR27 LPC/FM

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for

Insulation. A4/6 AW2242 Issue 1 Oct Kingspan Insulation

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls


CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.

Multi-layer Insulation Blanket for Walls


Light steel frame walls

Bituminous Building Paper

TRISO-SUPER 10 DATA SHEET

KoolthermTM. Installation Guide. HVAC & Building Services Pipe Insulation

Bituminous Roofing Underlay & Valley Guard

SOLITEX EXTASANA WALL PROTECTION MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 822 [2013] Appraisal No. 822 (2013) Amended 06 May 2014

National Construction Code Series (NCC) Building Code of Australia (BCA)

CERTIFICATE No VTT-C Date of issue

NEW Not just a vapour control layer, it also acts as supplementary insulation! HCONTROL REFLEX+

REFLECTIVE TECHNOLOGY CONSTRUCTION MEMBRANES

ThermaAdvantage. Conserve Energy and Save Costs with

TR26 LPC/FM. Insulation INSULATION FOR FLAT ROOFS WATERPROOFED WITH MECHANICALLY FIXED SINGLE PLY WATERPROOFING

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

K12 Framing Board INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS. P E R F O R M A N C E Manufactured to BS EN ISO 9002: 1994 Certificate No.

Multi-layer Insulation Blanket for use in Walls

wall TW50 zero ODP PARTIAL FILL CAVITY WALL INSULATION For more information on Kingspan Insulation visit

wall underlay Product BRANZ APPRAISAL No. 695 (2010) Scope Thermakraft Industries (NZ) Ltd PO Box Botany Manukau 2163 Auckland

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

PRODUCT CERTIFICATE THIS IS TO CERTIFY THERMAKRAFT STEELWRAP 290 WALL UNDERLAY

Eco-Versal. insulation. Polyisocyanurate (PIR) foam core with aluminium foil composite to both sides BASELINE TOPLINE SLIMLINE

Thermablok Aerogel Insulation Blanket Thermablok Aerogel Blanket

FlameSpec SS Roof Underlay

K8 Cavity Board. Insulation PARTIAL FILL CAVITY WALL INSULATION P E R F O R M A N C E BBA BRITISH

A monolithic finish, faster and easier

August 2008: Issue 1. Non - Residential New Build 4.5 Basements

June Residential Refurbishment Basements

K12 Framing Board INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS P E R F O R M A N C E

THE HIGH PERFORMANCE INSULATION FOR AIR CONDITIONING, HEATING, REFRIGERATION AND PLUMBING

HP Partial Fill. Robust, long-lasting protection

CI/Sfb 2- Rj7 - Eighth Issue May 2011

Thermablok Aerogel Isolation Strips

BDA Agrément BAW /01/C

June Non - Residential Refurbishment 5.5 Basements

Anticon roofing blanket

TR27 LPC/FM. Insulation

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

February savolitplus. natural building boards for sustainable construction

TECHNICAL. Cavity Wall Partial - Fill Insulation. Stylite.

PlyLok. Product Guide PIR and Plywood Laminate Insulation for Warm Flat Roofs.

PRODUCT CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE

June Residential New Build Timber Frame Walls

WATERGATE-PLUS 295 FIRE RETARDANT WALL UNDERLAY. Product. Scope. Appraisal No. 695 [2017]

The Ufoil Range of Insulation

TYVEK ROOF LINING SYSTEMS DUPONT AIRGUARD REFLECTIVE

NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. Date of update May 30, 2018 Valid until May 29, 2023 HYBRIS

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals

APPROVALS. Jabwall has been approved for this application since 1979, and was the first partial-fill insulation product to gain BBA approval.

Platinum. I n s u l a t i o n INSULATION FOR FLOORS. Low Energy Low Carbon Buildings

TRADE-COURSE DPC AND FLASHING. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 849 [2014] Appraisal No.

Kooltherm FM. Quick Guide HVAC & Building Services Pipe Insulation. UK & Ireland

Transcription:

Insulation A4/8 PS055XV AW2244 Issue 5 Oct 2017 Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES 5x higher vapour transmission than previous generation Reduces the risk of condensation Helps achieve a 6-star house energy rating 3-in-1 insulation, vapour-permeable membrane and radiant barrier Wall cavities remain unfilled and accessible for services Fibre-free, non-allergenic, non-irritant Quick and easy to install Water-resistant and unaffected by moisture Strong, tough, durable Rodent and insect resistant Flammability Index 5 BCA and AS/NZS 4859.1 compliant Made in Australia SAIG-CM20029

Double Brick Cavity Walls Typical Design Detail Face brickwork Permicav XV TM Spacer Biscuit TM (over wall tie) Cavity wall tie Permicav XV TM Face brickwork Internal brickwork Spacer Biscuit T M (over wall tie) Internal brickwork Cavity wall tie Hardwall plaster-finish Figure 2 Side elevation of Permicav XV TM in double brick cavity wall Installation Instructions 1. Lay outer leaf or brickwork with wall ties in place. Figure 1 Double brick cavity wall installation Thermal Performance Application Heat flow in Heat flow out Double brick cavity wall R T 1.8 R T 2.0 The R-values shown are Total R-values for the building element as required by the Energy Provisions of the Building Code of Australia. products are manufactured, tested and packaged in conformance with AS/NZS 4859.1. The contribution of the product Total R-values depends on installation and environmental conditions. Specification Guide The wall insulation fixed to the brickwork over the wall ties shall be Permicav XV TM fibre-free, thermo reflective insulation, comprising a cross-linked, closed-cell foam core sandwiched with an anti-glare foil facing on one side and a plain foil facing on the other side manufactured by Kingspan Insulation Pty Ltd, and shall be installed in accordance with the instructions issued by them. 2. Clip Spacer Biscuits TM onto every second wall tie, or as required to maintain a nominal 20 mm air space between the brick face and Permicav XV TM and push against the brickwork. 3. Roll out Permicav XV TM horizontally (antiglare facing installer) and offer up to the wall. 4. Cut a slit for each wall tie to penetrate the Kingspan AIR-CELL Permicav XV TM. 5. Push Permicav XV TM over the wall ties until it is against the Spacer Biscuits TM. 6. Allow a 50 mm overlap at joins with the upper layer overlapping on the outside of the lower, and tape with a 48 mm wide reinforced foil tape (please refer to brochure Kingspan Insulation Tape for further information). For detailed Installation Instructions please refer to the brochure Double Brick Cavity Walls. Scan to see the installation video 2

Brick Veneer Walls Typical Design Detail Timber stud Plasterboard lining Permicav XV TM Internal stud frame Permicav TM XV TM Face brickwork Plasterboard lining Timber framework Brick facing Figure 3 Brick veneer wall installation Thermal Performance Application Heat flow in Heat flow out Brick veneer wall R T 1.7 R T 1.9 The R-values shown are Total R-values for the building element as required by the Energy Provisions of the Building Code of Australia. products are manufactured, tested and packaged in conformance with AS/NZS 4859.1. The contribution of the product Total R-values depends on installation and environmental conditions. Specification Guide The wall insulation fixed to the outside of the stud frame shall be Permicav XV TM fibre-free, thermo reflective insulation, comprising a cross-linked, closed-cell foam core sandwiched with an anti-glare foil facing on one side and a plain foil facing on the other side manufactured by Kingspan Insulation Pty Ltd, and shall be installed in accordance with the instructions issued by them. Figure 4 Side elevation of Permicav XV TM in brick veneer wall Installation Instructions 1. Roll out Permicav XV TM horizontally and fix to outside of internal wall frame, working from the bottom up. 2. Allow 50 mm overlap between top and bottom layers and tape with 48 mm reinforced foil tape (please refer to brochure Kingspan Insulation Tape for further information). 3. Cut Permicav XV TM carefully around doors, windows and other openings, so that it neatly abuts to frames. 4. Penetrations for wall ties or services should be neatly cut to minimize gaps. For detailed Installation Instructions please refer to the brochure Brick Veneer Walls. Scan to see the installation video 3

Product Details Product Description Australian-made Permicav XV TM (Patent Pending 2014901279) is the next generation of vapour-permeable insulation. This evolution, specifically designed to reduce the risk of condensation in walls with cavities, has improved vapour transmission by five times compared to old technology. The micro perforations allow water vapour to permeate through while keeping moisture out and maintaining thermal resistance. Management Standards Standard BS / I.S. EN ISO 9001:2008 AS/NZS ISO 14001:2004 Product Specifications Management System Quality Management Evironmental Management Permicav XV TM is manufactured with a patented perforated closed-cell core sandwiched by highly reflective foil facings. Product Data Product Code PS055XV Product Thickness 5.5 mm Product R-Value R0.15 Roll Diameter 420 mm Roll Weight 7.7 kg Roll Size 1350 mm x 22.25 m (30 m 2 ) Reflectance Reflective Face 97% Anti-Glare Face 88% Emittance Reflective Face E0.03 Anti-Glare Face E0.12 Max. Span 2.4 m Characteristic Test Method / Standard Specification Flammability Index AS 1530.2 5 Material Thermal Resistance ASTM C518 0.15 m² K/W Emittance ASTM E408 Reflective Face: E0.03 Anti-Glare Face: E0.12 Duty Rating (Burst Force) AS 3706.4 1.0 kn - equivalent to Extra Heavy Duty Vapour Barrier ASTM E96 Low Resistance Shrinkage AS/NZS 4201.3 < 0.5% Dry Delamination AS/NZS 4201.1 Pass Wet Delamination AS/NZS 4201.2 Pass Water Barrier AS/NZS 4201.4 High Resistance Water Absorbency AS/NZS 4201.6 High Corrosion Resistance AS/NZS 4859.1 Appendix I Pass Environmental Data Figure 5 Vapour-permeable perforations in Kingspan AIR-CELL Permicav XV TM - 5x more efficient than its predecessor Aspect Recyclability Re-usability Water Use Ozone Depleting Substances Packaging Embodied Energy Characteristic Waste not recyclable Roll width to suit most applications to minimise on site waste Re-usable if removed with care (long term of service expected) No water used in Kingspan Insulation s manufacturing process None present in the finished product or in Kingspan Insulation s manufacturing process Contains approx 10% recycled product Packaging 100% recyclable 43 MJ/m 2 approximately 4

Condensation As thermal performance requirements for the building fabric continue to rise, condensation is becoming an increasingly important design consideration for healthy buildings. Ineffective management of moisture and vapours can potentially lead to indoor health issues and structural defects which require expensive remedial works. New improved Permicav XV TM reduces the risk of interstitial condensation by allowing vapour to permeate through tiny perforations even better. Figure 6 illustrates the high vapour permeability of Kingspan AIR-CELL Permicav XV TM compared to its predecessor and other common building materials. Water Vapour Transmission (g/hr.m 2 ) 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 0.00 Non-vapourpermeable reflective insulation Brick AIR-CELL Permicav AIR-CELL Permicav XV TM Figure 6 Water vapour transmission comparison. Our Technical Services team can also offer customised condensation risk advice for your projects, so you always get the right advice for the right application. N.B. Appropriate products should always be used for the appropriate climates, constructions and conditions. Depending on some variables, a vapour barrier may be preferable. Please contact us or consult your architect for more detailed advice. 5

General Requirements 1. Fit neatly around doors, windows, and any penetrations, and tape if necessary to prevent air leakage. 2. When taping a plastic squeegee or blade must be used to apply appropriate pressure to the tape. Surfaces must be dry and free from dust, oil or grease prior to taping (please refer to brochure Kingspan Insulation Tape for further information). 3. Leave minimum 50 mm clearance around heat producing flues or light fittings (refer to light fitting manufacturer). The instructions in this document are guidelines only and should be interpreted with consideration for the specific building design. The installation of should be in conformance with the applicable clauses from AS 3999 and AS/NZS 4200.2 unless otherwise specified. can be damaged by intense heat above 105 C and contact with sparks and flame from blow torches, welders, cutting tools, etc. must be avoided. The installer must make due provision for safety when installing in any application. Safety Information Non-hazardous/non-toxic. No personal protective equipment required. UV protective sunglasses and screen should be used when installing in direct sunlight. Ensure at least 50 mm clearance from hot flues and light fittings (check for safe distance with lighting supplier). Foil facings are conductive to electricity - avoid contact with un-insulated electrical cables and fittings. Handling and Storage insulation products must be transported and stored in its protective packaging and kept clean and dry. Standing rolls on end reduces risk of damage should moisture be present in the packaging. Surfaces must be kept free of contaminants such as dust and grease, and must not be stored with foil surfaces in contact with alkaline materials i.e. wet cement, lime, etc. 6

7

Contact Details General Enquiries Tel: 1300 247 235 Email: info@kingspaninsulation.com.au Kingspan Insulation Pty. Ltd. reserves the right to amend product specifications without prior notice. The information, technical details and fixing instructions etc. included in this literature are given in good faith and apply to uses described. Recommendations for use should be verified as to the suitability and compliance with actual requirements, specifications and any applicable laws and regulations. For other applications or conditions of use, Kingspan Insulation offers a Technical Advisory Service the advice of which should be sought for uses of Kingspan Insulation products that are not specifically described herein. Please check that your copy of the literature is current by contacting us or visiting www.kingspaninsulation.com.au Kingspan Insulation Pty Ltd Tel: 1300 247 235 Email: info@kingspaninsulation.com.au www.kingspaninsulation.com.au Kingspan, Kooltherm, Air-Cell, the zo Device and the Lion Device are Registered Trademarks of the Kingspan Group plc in Australia and other countries. All rights reserved. Kingspan Insulation Pty Ltd