City of Ottawa Street Lighting. Streetlight Brackets and Adapters

Similar documents
MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE

City of Ottawa Street Lighting. HID Coach Style Luminaire

City of Ottawa Street Lighting. Photoelectric Controllers

05510: TAPERED STEEL TROLLEY POLES AND ACCESSORIES

City of Ottawa Street Lighting. Pole Nomenclature Tagging

MATERIAL SPECIFICATION FOR HIGH PRESSURE SODIUM LUMINAIRES FOR HIGHWAY LIGHTING

POLE: ANCHOR BASE, ALUMINUM, TAPERED TUBULAR SHAFT

DETAIL SPECIFICATION PIPE, ALUMINUM ALLOY, DRAWN OR EXTRUDED

066 : 1998 CEB STANDARD GALVANIZED IRON PIPES FOR SERVICE CONNECTIONS CEYLON ELECTRICITY BOARD SRI LANKA

MATERIAL SPECIFICATION FOR LUMINAIRE RAISING AND LOWERING EQUIPMENT

Aluminum Component Pipe Railings

STANDARD SPECIFICATION FOR ALUMINUM FRAMING FOR RAILROAD PASSENGER SHELTERS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

SECTION LATCHWAYS CONSTANT FORCE POSTS

SECTION 1043 FENCE MATERIAL

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

ASTM B363-06a Standard Specification for Seamless and Welded Unalloyed

CITY OF CHARLOTTETOWN REQUEST FOR QUOTATIONS TRAFFIC SIGNALS - POLES AND ARMS

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

MATERIAL SPECIFICATION FOR STEEL POLES, BASE MOUNTED

SECTION FLAGPOLES

SECTION ORNAMENTAL ALUMINUM RAILING

TOWN OF GRAND FALLS-WINDSOR

DMS HIGH MAST LIGHT FIXTURES

A. Atlantic Railing Series with Mushroom Top and Square Pickets

SECTION 716 SIGN MATERIALS SCOPE

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION SUSPENDED MAINTENANCE ANCHORAGE SYSTEM

SECTION PREFABRICATED PIPE BRIDGE(s)

MATERIAL SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS

SECTION MISCELLANEOUS METALS

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ROADWAY LUMINAIRES

SECTION ORNAMENTAL ALUMINUM RAILINGS PART 1 - GENERAL 1.01 SUMMARY

SECTION TIMBER FLOATS

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

SECTION METAL DOORS & FRAMES

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ROADWAY LUMINAIRES

MATERIAL SPECIFICATION FOR SIGNAL HEADS

Division MEDICAL EQUIPMENT SUPPORT SYSTEMS PART 1 GENERAL

Model # 940S-P6-BB. 6/7/2017 Page 1 of 10

SECTION DECORATIVE METAL AND GLASS RAILING

SECTION STRUCTURAL METAL FRAMING

DBI-SALA Uni 8 Horizontal Lifeline Cable System

Model # 338S-PR. 5/1/2014 Page 1 of 12

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

DETAIL SPECIFICATION PIPE, ALUMINUM ALLOY, DRAWN OR EXTRUDED

Model # 338S-P. 7/31/2012 Page 1 of 13

DRAFT UGANDA STANDARD

MATERIAL SPECIFICATION FOR STEEL TRUSS BRACKETS

Model # 95-S8. Page 1 of 8

MATERIAL SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS

30-SDMS-01 SPECIFICATIONS FOR LOAD BREAK SWITCH

SECTION Athletic Field Equipment (Formerly 11480) DETAILED SECTION SOCCER AND FIELD HOCKEY EQUIPMENT

AMBICO Limited Section BLAST RESISTANT STEEL DOOR & FRAME ASSEMBLY Page 1

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

METAL FABRICATION..1 General Conditions and Division 1 shall govern Work of this section.

SECTION ORNAMENTAL ALUMINUM RAILING

Technical Specification for Aluminium Castings, Pole Caps and Pressed Symbols

Specification for Pipe Fittings

DBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE

A. ANSI A10.32, "Personal Fall Protection Used in Construction and Demolition Operations."

Model # 504S-P. 9/14/2011 Page 1 of 9

Model # 158-P4. 12/12/2013 Page 1 of 11

SECTION ORCHESTRA PIT FILLER

Foundation Specifications

Trex Commercial Products page Metal Railing

Model # 238HS-P8. 4/27/2011 Page 1 of 11

Model # 338SM-OP. 9/30/2011 Page 1 of 12

MATERIAL SPECIFICATION FOR SECTIONAL STEEL HIGH MAST LIGHTING POLES

Model # 338S-OP. 9/30/2011 Page 1 of 13

ELECTRICAL INSPECTION BULLETIN B Installation and Inspection Requirements for Street and Roadway Lighting Systems. (Effective 2015/11/15 )

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

Model # BT238-U6. 9/30/2014 Page 1 of 12

MATERIAL SPECIFICATION FOR SECTIONAL STEEL HIGH MAST LIGHTING POLES

Model # 338S-RDP. 7/31/2012 Page 1 of 13

MATERIAL SPECIFICATION FOR SMOOTH WALLED STEEL PIPE

REINFORCED CONCRETE CULVERT STORM DRAIN AND SEWER PIPE FIELD SECTION 1026

SECTION DECORATIVE METAL RAILINGS

PIP STF05520 Details for Pipe Railing for Walking and Working Surfaces

Model #369S-PR. 8/23/2016 Page 1 of 11

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

All definitions are defined according to ANSI/AWWA C

Model # 5803SM. 6/15/2018 Page 1 of 5

CONSTRUCTION SPECIFICATION FOR ERECTION OF POLES

CONSTRUCTION SPECIFICATION FOR ERECTION OF POLES

TECHNICAL SPECIFICATION FOR 11mtr. LONG STEEL TUBULAR POLE

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

TABLE OF CONTENTS INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

This specification covers the fabrication and delivery of Medium Series Traffic Signal/Pedestrian Corridor/Luminaire Davit Standards.

SECTION Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.

SECTION STRUCTURE MOUNT RAILING SYSTEM

SST-II HYDRAULIC BI-FOLD SPECIFICATIONS

Model #369S-RDP. 8/23/2016 Page 1 of 11

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

Model # 358PS-OP. 12/13/2013 Page 1 of 12

Model # 362S-RDP. 9/17/2012 Page 1 of 12

Transcription:

TITLE: Engineering Specification RECOMMENDED: S. Edey, NO: 1 REV: APPROVED: D. O Keefe LBS0001 OF REV. DATE: 2010-01-07 6 5 City of Ottawa Street Lighting Streetlight Brackets and Adapters For City of Ottawa Use Only

REVISION SHEET REVISION DESCRIPTION DATE INITIAL 1 Add 4.7m bracket 2005-02-24 csm/jb Renamed LPS0011 to LBS0011, LBS0001, and LBS0002 Text and Drawings 2 Supersedes LBS0004 General Conditions referenced in separate specification Revised scope 3 Associated Standard Drawings identified (10.0) 2006-01-15 csm jb 2007-01-15 jb 4 51mm IPS tenon (4.0) 2007-12-05 jb 5 Approval and Recommended authorization changed 2010-01-07 se do For City of Ottawa Use Only LBS0001 Rev.5 Page 2 of 6

TABLE OF CONTENTS 1.0 GENERAL... 4 1.1 SCOPE... 4 2.0 REFERENCE STANDARDS... 4 3.0 APPROVAL OF SOURCE... 4 4.0 MECHANICAL REQUIREMENTS... 4 5.0 INFORMATION SUPPLIED TO THE BIDDERS... 5 6.0 INSTRUCTIONS TO BIDDERS... 5 6.1 GENERAL... 5 6.2 INFORMATION TO BE PROVIDED IN QUOTATIONS... 5 6.3 SAMPLES... 5 7.0 INSPECTION... 5 8.0 SHIPMENT... 5 9.0 WARRANTY... 6 10.0 DRAWINGS... 6 For City of Ottawa Use Only LBS0001 Rev.5 Page 3 of 6

1.0 General 1.1 Scope This specification covers the safety strength requirements, mounting/grounding arrangements and size classification for tapered elliptical aluminium brackets for supporting "cobra head" luminaries in addition to specialty brackets. This specification section shall be read in conjunction with engineering specification LGC0001. 2.0 Reference Standards Brackets shall comply with all applicable requirements in the latest issues of the following standards: ANSI Standard C136.13 ASTM Standard B221 ASTM Standard B241 CSA Standard S157 CSA Standard W59.2 Metal Brackets for Wood Poles Used in Roadway Lighting Aluminium Alloy Extruded Bars, Rods, Wire, Shapes and Tubes Aluminium Tubing - Aluminium Alloy Seamless Pipe and Seamless Extruded Tube Strength Design in Aluminium Welded Aluminium Construction The supplier shall be certified in accordance with the CSA Standard W47.2, certification of companies for fusion welding of Aluminium. The detail drawings attached to this specification complement and form part of the requirements of this specification. 3.0 Approval of Source Only manufacturers approved by the City of Ottawa or its agent shall supply brackets. Only brackets evaluated and approved before submission of a quotation will be accepted. Each bracket supplied shall be of the same construction currently approved by the City of Ottawa or its agent and once approved, the supplier shall not supply brackets with substantive changes in design without prior approval. 4.0 Mechanical Requirements The bracket arm shall be fabricated from aluminium alloy No. 6063-T4 tubing (heat treated after fabrication to -T6) or equivalent. The bracket shall not be torn apart or otherwise fail in such a manner as to shed an applied load of 115 kg vertical and 25 kg horizontal applied separately for ten minutes within 150mm of the luminaire end of the bracket. The bracket while supporting a luminaire under Class C loading, shall withstand without permanent deformation, a wind load of 3.6 kg (approx. 88km/h and an ice load of 1.27 cm or alternatively, a wind load of 18.0 kg (approx. 130 km/h) without ice. The bracket shall be fabricated with a 51mm IPS tenon to permit safe mounting and support of a luminaire 0.21 m 2 projected area maximum and 25 kg maximum. All sharp edges and holes shall be chamfered to remove burrs. For City of Ottawa Use Only LBS0001 Rev.5 Page 4 of 6

Bracket arm shall be rotary polished overall with No. 80 grit or otherwise finished to a smooth and uniform appearance. Any finish other than rotary polished shall be stated at the time of quotation. Each bracket shall have identification stamped on the pole plate showing the manufacture's name or trademark and the date of manufacture. 5.0 Information Supplied To The Bidders The following information will be supplied to the bidder: a) Quantity b) Length c) Pole Mounting d) Mounting Hardware (if required) e) Grounding Provisions (if required) f) Protection for Shipment (if required) 6.0 Instructions To Bidders 6.1 General Suppliers shall submit with their quotations the information requested herein. Suppliers who fail to provide the information requested might have their quotations rejected as incomplete. 6.2 Information to be provided in Quotations Each bidder shall submit with his quotation two copies of the Outline Drawing. 6.3 Samples If requested, the supplier shall provide a sample identical in every way to the units being tendered. Samples will be returned to the supplier after evaluation. 7.0 Inspection The purchaser reserves the right to act as its own inspection agency or appoint an inspection agency to observe all steps of manufacturing testing and verification of the requirements of this specification. 8.0 Shipment When requested, each bracket shall be individually wrapped with paper or jute to provide reasonable shipping protection against permanent marking of the polished surfaces. The supplier shall obtain approval from the purchaser prior to delivery. For City of Ottawa Use Only LBS0001 Rev.5 Page 5 of 6

9.0 Warranty The manufacturer shall warrant that the brackets furnished by them conform to all the requirements and conditions of this specification. The manufacturer shall repair or replace, at no expense to the purchaser, defects due to fault workmanship, material or design for a period of five years after installation of the brackets, but in no case for more than six years after receipt of the unit by the purchaser. All shipping charges shall be the responsibility of the supplier. 10.0 Drawings LBD0001, LBD0002, LBD0003, LBD0004, LBD0005, LBD0006, LBD0007, LBD0008. For City of Ottawa Use Only LBS0001 Rev.5 Page 6 of 6